You are on page 1of 82

CA.

NO: CEJZ/JSLR/ OF 2017-18 SERIAL PAGE NO:


 

Tele: (0291) – 2515113/2511518 Military Engineer Services


(Email id: cezjp2-mes@nic.in) Headquarters
Chief Engineer Jodhpur Zone
ECHS Complex Jodhpur
Jodhpur - 342010

800419/ 18 /E8 02 Aug 2017

M/S _____________
_________________
_________________

CORRIGENDUM NO - 1
PROVISION OF 3 MW SOLAR POWER PLANT (JOB No SC/MW/1256) AT JAISALMER.

(TENDER ID 2017_MES_129652_1)
Dear Sir(s)

1. Reference tender documents for the above subject work published on the e-tendering
site under vide this HQ letter No. 800419/ 10 /E8 dated 13 July 2017.

2. The existing serial page No 1 and Existing complete Schedule ’A’ i.e. (Page no. 21 to
41) are hereby cancelled and replaced with revised serial pages bearing No 1(R) and
21 (R) to 41 (R) are enclosed herewith.

3. Existing complete BOQ has been Cancelled in to-to & replace It by new revised
complete BOQ containing Sr. Page no 44(R) to 69(R), 69R(A) , 69R(B) and 69R(C)
respectively attached herewith.

4. Please carryout amendments to the tender documents as per Appendix ‘A’ attached
herewith. This letter along with Appendix ‘A’ now uploaded shall form part of the tender
documents.

5. Structural and other Drgs (58Nos.) not uploaded along with tender are now uploaded
herewith.

6. All other details remain unchanged.

Yours faithfully,

(Vipin Kumar Meena)


Asst. Dir (Contracts)
For Accepting Officer
Signature of contractor
Dated :
Uploaded Docs :
(i) Revise pages
Schedule ’A’ – 21pages
BOQ - 29pages
(ii)Additional Drawings : 58 Drawings
CA.NO: CEJZ/JSLR/ OF 2017-18 SERIAL PAGE NO:
 

 
APPENDIX ‘A’ to this HQ’s    
 Letter No. 800419/ 18   /E8 
Date 02 August 2017 
CORRIGENDUM TO TENDER DOCUMENT

Sr Page Location Particulars


No No
1 2 3 4
1. 1 CONTENTS PAGE Cancel existing page in to-to & replace it by new
revised page containing Sr No 1(R) attached herewith.

2 14(b) NOTICE OF TENDER For : 8002419/09 /E8


(NOT) APPX ‘A’ Read : 800419/09 /E8
File no.
3 16 Schedule ’A’ Note no.6 For : Sr item no 55.00&55.01 to 55.05
Phase-II Read : Sr item no 57.00&57.01 to 57.05

3 21 to SCHEDULE ‘A’ PART-I TO Existing complete SCHEDULE ‘A’ has been


41 PART-XI Cancelled in to-to & replace It by new Revised
SCHEDULE ‘A’ 21 (R) to 41(R) attached herewith.

4. 44to BOQ Existing complete BOQ has been Cancelled in to-


69 to & replace It by new Revised BOQ attached
herewith.

SPECIAL CONDITIONS
5 Page Spl Condition Para 24.1 For : Charged @ Rs……
136 Line-2 Read : Charged @ Rs 23.00 per kiloliter
6 Page Spl Condition Para 30.1 For : (including Sales Tax/VAT on materials,
138 Line-1&2 Sales Tax/VAT on Works Contracts, Turnover Tax,
Labour Welfare Cess/tax etc.)

Read : (including GST i.e. CGST& SGST, Labour


Welfare Cess/tax etc.)

7 Page Spl Condition Para 30.2 For : such as sales Tax/VAT on Work Contracts,
138 Line-2&3 Turnover Tax, Labour Welfare Cess/tax and like but
excluding Income Tax. .

Read : such as GST i.e. CGST& SGST, Labour


Welfare Cess/tax and like but excluding Income Tax.
.

PARTICULAR SPECIFICATIONS
8 162 Clause no 6.16 FOR:- “RCC CJAJJA”
READ:- “RCC CHAJJA”
9 213 Clause no 31.8.2.4, FOR:- “180 kmph”
last line READ:- “150 kmph”
10 214 Clause no 31.8.3.3, FOR:- “180 kmph”
last line READ:- “150 kmph”
11 215 Clause no 31.8.4.3, FOR:- “169.2 kmph”
last line READ:- “150 kmph”
11 216 Clause no 31.9.1.14 FOR:- “180 kmph”
last line READ:- “150 kmph”
12 218 clause No.31.9.3.1 FOR “’string inverter type 8 Nos.”’
READ “’grid power inverter type 3 Nos. each 1000KVA
Capacity”’

13 Page PS Cl 13.70 For : 50mm


187 Line 1 Read : 60mm
CA.NO: CEJZ/JSLR/ OF 2017-18 SERIAL PAGE NO:
 

APPENDIX ‘’C’’ LIST OF MAKES


13. 237 Sr no 83, Col 3, Sr After Sr no (N), add as under:-
no (N) ‘’(O) BHEL’’
14. 238 Sr no 129, Col 1 to 3 After Sr no 130, add as under in respective columns:-
15. ‘’130. GRID INVERTER (a) ABB
(b) SCHNEIDER’’
LIST OF DRAWINGS
16. Drg. E/M PLAN & SCHEDULE Description of internal wall finishes is not shown
No. OF FINISHES in schedule of Finishes are as under:-
CEJZ/ (Sch of Finishes) For Inverter Room And Control Room- two coats
WD/89/ of OBD is to be provided
2017
For Store Room- two coats of white wash is to be
(3/3)
provided.

17. 228-C Add after Sr no 66, Add new drawings in respective columns as under:-
Col 1 to 7
18. 67. TYPICAL DETAILS OF VALVE CEBZ/TD/43/2011 1/1 01.01.11 - -
PIT & SECTION AT A-A
19. 68.RCC UNDER GROUND UG SUMP CEJZ/STR/STD/48/2015 13/16 12.05.15 -

20. 69.RCC UNDER GROUND UG SUMP CEJZ/STR/STD/48/2015 14/16 12.05.15 -

21. 70.RCC UNDER GROUND UG SUMP CEJZ/STR/STD/48/2015 15/16 12.05.15 -

Asst. Dir (Contracts)


For Accepting Officer
Signature of contractor
CA NO CEJZ/ JSLR/ OF 2017-18 SERIAL PAGE NO. 1(R)

MILITARY ENGINEER SERVICES


NAME OF WORK: PROVISION OF 3 MW SOLAR POWER PLANT (JOB No SC/MW/1256) AT
JAISALMER.
CONTENTS

S. Description Page
No From To

01. Contents 1(R) To 1(R)

02 Forwarding letter including instructions for filling and 2 To 7


submission of tender documents

03. Notice of tender including Appendix ‘A’ 8 To 14

04. 15 To 20
21(R) To 41(R)
Lump Sum Tender and contracts for works on tender form
42 To 43
IAFW-2159 (Revised 1947)
44(R) To 69(R)
69(R)A, 69(R)B
69(R)C and 70
05. General Conditions of Contract (IAFW – 2249) including Errata 71 To 129
& amendments thereto and Schedule of Minimum Wages

06. Special Conditions 130 To 146

07. Particular specifications including list of drawings and 147 To 238


Appendix ‘A’, ‘B’, ‘C’

08 Amendments to tender documents 239 To 241

09 Relevant correspondence

10 Acceptance letter

_______________
Total No of Pages _______________

Drgs _______________

Signature of Contractor Asst. Dir (Contracts)


For Accepting Officer
CA NO : CEJZ/JSLR/ OF 2017-18 SERIAL PAGE NO 21 (R)
SCHEDULE ‘A’ PART- I
(BUILDING WORKS)
NAME OF WORK : PROVISION OF 3 MW SOLAR POWER PLANT (JOB No SC/MW/1256) AT
JAISALMER.
Refer Note 13 on page No 17 for column 3, 7 and 8
S Description of item of works Rate per Unit No of Amount (Rs)
/No (Rs) units
require
d

1 2 4 5 6

1 Construction of block of one Control Room with Inverter 1423000.00 1 1423000.00


& Duty Room complete all as specified and shown on EACH
drawings. BLOCK

2 Construction of block of one Inverter Room complete all 679000.00 2 1358000.00


as specified and shown on drawings. EACH
BLOCK
3 Construction of semi under ground sump cum pump house 474000.00 1 474000.00
of capacity 20000 Gallon complete all as specified and EACH
shown on drawings. BLOCK
TOTAL AMOUNT OF SCHEDULE "A" PART-I C/O BOQ 3255000.00

Signature of contractor Asst Director (Contracts)


Date : For Accepting Officer
CA NO : CEJZ/JSLR/ OF 2017-18 SERIAL PAGE NO 22(R)
SCHEDULE ‘A’ PART -II
( SITE CLEARANCE & EXCAVATION & EARTH WORK )
Refer Note 13 on page No 17 for column 3, 7 and 8
Rate per
No of
Sr Unit (Rs)
Description of item of works units Amount (Rs)
/No
required
1 2 4 5 6

1 Excavation over area n.exc 1.5 m deep and getting out in any 106.20 24820 2635884.00
type of soil complete all as specified & directed. CUM

2 Excavation over area n.exc 1.5 m deep and getting out in soft / 307.80 3750 1154250.00
disintegrated rock complete all as specified & directed. CUM

3 Surface excavation n.exc 30 cm deep and averaging 15 cm 21.85 3420 74727.00


deep and getting out in any type of soil complete all as SQM
specified & directed.

4 Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in 462.70 48 22339.16
depth for foundation and getting out in soft / disintegrated CUM
rock complete all as specified and directed.
5 Excavation in trenches, n.exc 1.5 m wide and exc 1.5 m but n. 520.30 18 9365.40
exc 3m in depth for foundation and getting out in soft / CUM
disintegrated rock complete all as specified and directed.
6 Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in 158.85 165 26208.66
depth for foundation and getting out in any type of soil CUM
complete all as specified and directed.
7 Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in 115.20 1224 140990.98
depth for foundation and getting out in soft/loose soil CUM
complete all as specified and directed.

8 Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in 202.50 99 20017.13
depth for foundation and getting out in hard/dense soil CUM
complete all as specified and directed.

Total amount of Schedule ‘A’ Part-II c/o to Summary Rs 4083782.32


CA NO : CEJZ/JSLR/ OF 2017-18 SERIAL PAGE NO 23 (R)
SCHEDULE 'A' PART - II (CONTD….)
( SITE CLEARANCE & EXCAVATION & EARTH WORK )
Refer Note 13 on page No 17 for column 3, 7 and 8
1 2 4 5 6

9 Excavation in post holes (or similar holes) in any type of soil 96.20 395 37999.00
each not exc 0.50 cum, getting out, returning, filling in and EACH
ramming earth or broken rubble mixed with earth around in
layers not exc 25 cm watering and removing surplus soil/rock to
a distance not exc 50 m and making good surface complete all
as specified and directed.

10 Returning, filling in including spreading, leveling, watering and 41.70 340 14163.82
well ramming in layers n. exc 25 cm thick in soil complete all CUM
as specified and directed.

11 Removing excavated material (Soil) to a distance n.exc 50 mtr 96.10 115 11063.99
and depositing where directed at a level n.exc 1.5m above the CUM
starting point complete all as specified and directed.

12 Removing excavated material (Soil) to a distance exc 250mtr 149.40 22500 3361500.00
but n.exc 500 mtr and depositing where directed at a level CUM
n.exc 1.5m above the starting point complete all as specified
and directed.
13 Removing excavated material (Rock) to a distance exc 250mtr 200.60 3750 752250.00
but n.exc 500 mtr and depositing where directed at a level CUM
n.exc 1.5m above the starting point complete all as specified
and directed.
14 Removing excavated material (Soil) to a distance exc 150mtr 148.50 3737 555003.90
but n.exc 250 mtr and depositing where directed at a level CUM
n.exc 1.5m above the starting point complete all as specified
and directed.
15 Removing excavated material (soft /disintegrated Rock) to a 131.80 66 8735.70
distance exc n.exc 50 mtr and depositing where directed at a CUM
level n.exc 1.5m above the starting point complete all as
specified and directed.
Total amount of Schedule ‘A’ Part-II c/o to Summary 4176976.82

COLLECTION OF SCHEDULE 'A' PART -II

Total Amount brought forward from Sl Page No.22 = Rs. 4083782.32

Total Amount brought forward from Sl Page No.23 = Rs. 4176976.82

Rs. 8260759.13

Signature of contractor Asst Director (Contracts)


Date : for Accepting Officer
CA NO : CEJZ/JSLR/ OF 2017-18 SERIAL PAGE NO 24 (R)
SCHEDULE ‘A’ PART -III
( INTERNAL WATER SUPPLY )
Refer Note 13 on page No 16 for column 3, 7 and 8
S/N Description of item of works Rate per No of
o Unit (Rs) units Amount
requir (Rs)
ed
1 2 4 5 6

1 S&F mild steel tubes, medium grade (ISI Marked), galvanised with all
fitting (ISI Marked) and concealed or fixed complete to wall, ceiling or
laid in floors complete all as specified & directed of following sizes :-

(a) 25mm bore. 227.50 10 2275.00


RM
(b) 20mm bore. 153.80 20 3076.00
RM
(c) 15mm bore. 116.60 10 1166.00
RM
2 Supply and fixing for gun-metal, globe or gate valves (ISI Marked)
with iron wheel head, screwed both ends for iron pipe complete of
following sizes:-
(a) 20mm bore. 252.20 1 252.20
EACH
(b) 25mm bore. 413.80 1 413.80
EACH
3 S&F, bib taps, cast copper alloy fancy type, long shank, chromium 180.30 2 360.60
plated (ISI Marked), with crutch or butter fly handle, screwed down, EACH
screwed for iron pipe or for brass ferrule and fixed to 15mm bore pipe
complete all as specified & directed.
4 S & F angle stop valves, cast copper alloy (ISI Marked) chromium 169.00 3 507.00
plated, screwed down, high pressure with crutch handle screwed both EACH
ends for iron pipe or unions 15mm bore complete all as specified &
directed.

TOTAL AMOUNT OF SCHEDULE "A" PART-III C/O BOQ 8050.60

Signature of contractor Asst Director (Contracts)


Date : for Accepting Officer
CA NO : CEJZ/JSLR/ OF 2017-18 SERIAL PAGE NO 25 (R)
SCHEDULE ‘A’ PART-IV
(INTERNAL ELECTRIFICATION)
Refer Note 13 on page No 17 for column 3, 7 and 8
S/N Description of item of works Rate per No of Amount (Rs)
o Unit (Rs) units
requir
ed
1 2 4 5 6
NOTE:-
(i) The complete wiring installation shall be carried out in accordance and conformity with IS: 732
:1989 "Code of practise for electrical wiring(latest version)"
(ii) The unit rate against item of PVC concealed conduit point wiring includes for MS pressed steel
sunken boxes conforming to IS: 5139 (Part 1):1969, duly painted with two coats of anti corrosive paint
/ black bituminous paint externally and two coats of aluminium paint over a coat of red oxide primer
internally, for fixing switches, regulators, socket outlets etc with 3 mm thick plastic laminated sheet ISI
marked.
(iii) All screws, fasteners, bolts, nuts & washers etc shall be of cadmium plated, the cost of which is
deemed to be included in the unit rate.
(iv) The complete wiring installation shall be tested on completion as specified in particular
specifications.
(v) The cutting/leaving, forming chases shall be done with electric cutter and not by chiselling.

1 Point wiring using approved colour coding as per IS (Red, Black and
Green for single phase circuits), with multi-stranded copper
conductor 1.5 Sq. mm nominal cross-sectional area, single core,
PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-
694 marked with valid CML No. in and including medium grade,
PVC concealed conduit of dia not less than 20mm and conduit
accessories, ISI marked with valid CML No.(IS-9537-1983 for
conduits and IS:3419:1976 for conduit accessories) concealed in
wall/roof/floor etc with mild steel/pressed steel sunken boxes (with
earth dolly) duly painted with two coats of anti corrosive
paint/aluminium paint over a coat of red oxide primer internally and
two coats of black bituminous paint over a coat of red oxide primer
externally, covered with 3mm thick plastic laminated sheet cover for
fixing of switches, sockets etc including PVC insulated multi-
stranded copper conductor 1.5 Sqmm nominal cross sectional area
single core FRLS cable as earth continuity conductor to common
earth and connecting to earth dolly complete all as specified and
directed for the following :-
NOTE: - Switch and socket to be measured and paid for separately.

(a) One light /fan point controlled by one, one way SP switch 509.10 29 14763.90
POINT
(c) One socket out let, 5 pin, 5/6 Amp on same board 84.00 6 504.00
POINT
(d) One switch socket out let 5 pin, 5/6 Amp on independent board 509.10 2 1018.20
POINT

Total amount of Schedule ‘A’ Part-IV c/o to Summary Rs 16286.10


CA NO : CEJZ/JSLR/ OF 2017-18 SERIAL PAGE NO 26 (R)
SCHEDULE 'A' PART - IV (CONTD….)
(INTERNAL ELECTRIFICATION)
Refer Note 13 on page No 17 for column 3, 7 and 8
1 2 4 5 6

2 All as per item No 1 here in before but point wiring with 4.00 sqmm 990.00 1 990.00
single core multi stranded copper conductor PVC insulated and POINT
unsheathed (FRLS) cable 1100 volts grade and 4.00 Sqmm PVC
insulated and unsheathed (FRLS) cable 1100 volts grade with multi-
stranded copper conductor as earth wire for 15/16 Amps multi
purpose socket combination point on independent board.

3 Supply and fixing switch piano; flush type, single pole, one way and 34.30 37 1269.10
5/6 Amp, ISI marked with IS: 3854 with valid CML No. complete all EACH
as specified and directed.

4 Supply and fixing switch piano; flush type, single pole, one way, and 86.50 1 86.50
15/16 Amps IS: 3854 marked with valid CML No. complete all as EACH
specified and directed.

5 Supply and fixing socket outlet multipurpose having provision for 3 51.50 8 412.00
pin, 5 Amp and 2 pin, 5 Amp, piano flush type IS: 1293-2005 marked EACH
with valid CML No complete all as specified and directed.

6 Supply and fixing socket outlet multipurpose having provision for 3 95.20 1 95.20
pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type IS: 1293-2005 EACH
marked with valid CML No complete all as specified and directed.

7 Supply and fixing, ceiling fan regulator electronic stepped flush type 219.80 4 879.20
230 Volts, ISI marked with valid CML No and connecting up EACH
complete all as specified and directed.

8 Supply and fixing ceiling rose, three brass terminal, ISI marked, 22.80 29 661.20
PVC/polycarbonate, isolated body complete all as specified and EACH
directed.

Total amount of Schedule ‘A’ Part-IV c/o to Summary Rs 4393.20


CA NO : CEJZ/JSLR/ OF 2017-18 SERIAL PAGE NO 27 (R)
SCHEDULE 'A' PART - IV (CONTD….)
(INTERNAL ELECTRIFICATION)
Refer Note 13 on page No 17 for column 3, 7 and 8
1 2 4 5 6

9 Supply and fixing, MCB Distribution board, SPN, 6 way, double door 1053.60 1 1053.60
(concealed flush to wall), , for mounting MCBs, factory made, EACH
confirming to IS : 13032 fabricated out of CRCA sheet not less than
1.20 mm thick fitted with DIN channel, neutral link and 200 Amps
rated bus bar DBs shall be semi glossy finished with epoxy polyester
based powder paint sprayed and backed at high temperature,
between powder paint process to ensure smooth finish and
protection against corrosion atmosphere. The DBs shall be double
door type with hinged door with locking arrangerment. The DBs shall
be of same make as MCBs. DB shall also be provided with lable
marking indicating the incoming and outgoing circuits on all ways as
specified.The DBs shall be of IP 42 procteciton class complete all as
specified & directed

10 Material and labour for sub-main wiring with two run of PVC 116.00 80 9280.00
insulated stranded copper conductor of size 2.5 sqmm copper RM
conductor as continuity earth wire drawn through and incl PCX
conduit concealed type (medium duty) of adequate size with fittings
& fixtures incl making good in CM (1:3) all as specified and directed
Note: Two run of 2.5 sqmm one run of PVC conduit shall be
measured as one run.

Total amount of Schedule ‘A’ Part-IV c/o to Summary Rs 10333.60

SUMMARY OF SCHEDULE "A" PART-IV

Total amount brought forward from Sl page No 25 Rs 16286.10

Total amount brought forward from Sl page No 26 Rs 4393.20

Total amount brought forward from Sl page No 27 Rs 10333.60

TOTAL AMOUNT OF SCHEDULE "A" PART-IV C/O BOQ Rs 31012.90

Signature of contractor Asst Director (Contracts)


Date : For Accepting Officer
CA NO : CEJZ/JSLR/ OF 2017-2018 SERIAL PAGE NO 28 (R)
SCHEDULE ‘A’ PART-V
( ROAD, CULVERT, FOOTPATH & HARD STANDING)
Refer Note 13 on page No 17 for column 3, 7 and 8
S/N Description of item of works Rate per No of Amount (Rs)
o Unit (Rs) units
required

1 2 4 5 6

1 Rolling and consolidating to required gradient and camber of 8.00 560 4480.00
formation surface (cutting or filling) of roads with 8 to 12 tonne power X SQM
roller including filling in depressions which occur during rolling
complete all as specified & directed.

2 M & L for 200 mm thick (spread thickness ) soiling (or sub base) 1675.70 560 938392.00
with crushed or broken stone of grading 2 (63 to 90mm size), X SQM
interstices filled, surface formed and rolled and consolidated to
required gradient and camber with 8 to 12 ton power roller complete
all as specified & directed.

3 M&L for 150mm thick (compacted thickness) water bound macadam 1519.00 560 850640.00
in two layers each of 75mm thick (each layer to be rolled and X SQM
consolidated separately) with coarse aggregate of sand stone, flint or
quartize of grading 2 (63mm to 40mm), hollows made up to form
true surface, spread, surface binding with and including screening
and moorum, watered, consolidated and rolled with 8 to 12 tonne
power roller to gradient and camber required complete all as
specified and as directed.
4 M&L for preparing un-surfaced WBM surfaces by brushing with wire 2900.10 560 1624056.00
brushes for removing caked mud etc, sweeping with brooms and X SQM
finally fanning the cleaned surfaces with gunny bags to remove all
loose dirt etc and applying evenly a tack coat of VG-10 grade paving
bitumen @ 10 Kg per 10 Sqm and and applying bituminous
premixed semi dense asphalitic concrete 40 mm consolidated
thickness with 5.5% binder content by weight of total mix rolled and
compacted with 8 to 12 tonne power roller to required camber and
gradient to achieve a uniform smooth surface complete all as
specified and as directed.
5 M & L for spreading 25mm thick layer of sand cushioning complete 542.60 41 21975.30
all as specified and as directed. CUM
6 M&L for Stone kerb of roughly squared stones (Lime or Sand stone) 173.60 4600 798560.00
of size15cm x 30cm, all surfaces hammer dressed so that the RM
maximum depression from a straight edge held against the dressed
surface shall not exceed 20mm jointed in cement mortar 1:6 and
struck flush complete all as specified and directed

7 M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone 2579.00 6 15474.00
aggregate as in bed & haunching concrete for hume pipe complete CUM
all as specified and directed.

Total amount C/O to summary of Schedule `A` Part V Total 4253577.30


CA NO : CEJZ/JSLR/ OF 2017-18 SERIAL PAGE NO 29 (R)
SCHEDULE ‘A’ PART-V
( ROAD, CULVERT, FOOTPATH & HARD STANDING)
Refer Note 13 on page No 17 for column 3, 7 and 8
1 2 4 5 6

8 M&L 450 mm dia RCC Hume pipe with collar, class NP-3, laid & 1402.20 36 50479.20
jointed in CM (1:1) complete all as specified and directed. RM

9 M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone 2303.30 3 7785.15
aggregate as in foundations of wall complete all as specified and CUM
directed.

10 M&L for stone walling of squared rubble ,regular coursed, well 2278.80 16 36005.04
bonded, bedded and solidly hearted, built in CM (1:4) complete all as CUM
specified and directed.

11 Extra over stone masonry for hammer dressing to face stones with 119.00 22 2641.80
maximum depression on face from a straight edge held against the SQM
dressed surfaces not exc 20 mm and dressing face beds and joints
as specified to squared rubble walling, Jodhpur type, regular coursed
complete all as specified and directed.

12 M&L for keyed pointing in CM (1:3) over squared rubble stone 454.40 2.22 1008.77
walling Jodhpur type, regular coursed complete all as specified and X SQM
directed.

13 M&L for preparation of newly plastered/unplastered surfaces of 11.10 22 246.42


wall/concrete & applying three coats of white wash complete all as SQM
specified and directed.

14 M&L for PCC 1:3:6 type C-1 using 20mm graded aggregate copings, 3656.70 0.68 2486.56
kneelers, apex stones, bed plates, water throughs and like including CUM
weathering, slightly rounded or chamfered angles and throating
including necessary form work complete all as specified and
directed.

15 M & L for berms 75 mm thick (spread thickness) with approved 399.90 342.00 136765.80
moorum or red bajri leveled, spread, rolled and consolidated to X SQM
required gradient and camber with 0.2 to 0.5 ton hand operated roller
complete all as specified and as directed.
16 M&L for 100mm thick PCC (1:3:6) type C-2 using 40 mm graded 256.90 1620 416178.00
stone aggregate in sub base to path complete all as specified and SQM
as directed.

17 M&L for machine pressed precast conctete interlocking paver block 516.60 1620 836892.00
any shape and size confirming to IS 15658-2006 of 60 mm thickness SQM
M-35 Grade using grey cement & pigments complete all as specified
and as directed.
18 M&L for PCC 1:2:4 type B-1 using 20mm graded aggregate copings, 4144.40 15.30 63409.32
kneelers, apex stones, bed plates, water throughs and like including CUM
weathering, slightly rounded or chamfered angles and throating
including necessary form work complete all as specified and
directed.
Total amount C/O to summary of Schedule `A` Part V 1553898.06
CA NO : CEJZ/JSLR/ OF 2017-18 SERIAL PAGE NO 30 (R)

SUMMARY OF SCHEDULE ‘A’ PART- V


Total brought forward from Ser Page No 28
4253577.30

Total brought forward from Ser Page No 29


1553898.06

Total amount of Schedule ‘A’ Part- V carried over to BOQ 5807475.36

Signature of contractor Asst Director (Contracts)


Date : For Accepting Officer
CA NO : CEJZ/JSLR/ OF 2017-2018 SERIAL PAGE NO 31(R)
SCHEDULE ‘A’ PART-VI
( SEWAGE DISPOSAL )
Refer Note 13 on page No 17 for column 3, 7 and 8
S/No Description of item of works Rate per No of
Unit (Rs) units
Amount (Rs)
require
d
1 2 4 5 6

1 M&L for PCC (1:3:6) type C-2 using 40 mm graded crushed stone 2579.00 0.73 1882.67
aggregate in foundation, filling and mass concrete complete all as CUM
specified and directed.

2 M&L for PCC (1:3:6) type C-2 using 40 mm graded crushed stone 194.40 19 3693.60
aggregate in concrete bedding to drain pipes including packing RM
under hauching against the sides of pipes after they are laid and
tested for 150 mm bore pipe complete all as specified and directed.

3 M&L 150 mm dia RCC Hume pipe with collar, class NP2, laid & 283.30 20 5666.00
jointed in CM (1:1) complete all as specified and directed. RM

4 M&L, Pre-cast cement concrete block masonry with solid block of 3536.50 1.58 5587.67
PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate), CUM
exceeding 10 cm in width and set in CM (1:4) complete all as
specified and directed.

5 M&L for PCC 1:3:6 type C-1 using 20mm graded aggregate copings, 3656.70 0.11 402.24
kneelers, apex stones, bed plates, water throughs and like including CUM
weathering, slightly rounded or chamfered angles and throating
including necessary form work complete all as specified and
directed.

6 M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate 3136.50 0.10 313.65
as in surface channels / drains, and benching including finishing top CUM
of benching even and smooth using extra cement complete all as
specified and directed.
Note: - Forming fair finished channel shall be measured and
paid separately.
7 Extra for forming fair finished drain or channel 30 cm inner girth in 14.90 2 33.53
cement concrete using extra cement including forms, moulds, RM
mitred/stopped ends etc. complete all as specified and directed.

8 Add to or deduct from item No 7 for forming fair finished channels or 1.90 For adjustment only
drains for each 25 mm girth or part thereof over or under 30 cm RM
complete all as specified and directed.
NOTE: - This item is only for adjustment of rate if applicable.

9 M&L for 15mm thick rendering in CM (1:4) mixed with water proofing 127.40 9 1112.20
compound as per manufacturer's instructions on fair faces of SQM
brick/concrete surfaces, finished even and smooth without using
extra cement complete all as specified.

Total amount C/O to summary of Schedule `A` Part VI Total 18691.55


CA NO : CEJZ/JSLR/ OF 2017-2018 SERIAL PAGE NO 32(R)
SCHEDULE ‘A’ PART-VI (Contd….)
(SEWAGE DISPOSAL)
Refer Note 13 on page No 17 for column 3, 7 and 8
1 2 4 5 6

10 Supply only integral water proofing compound complete all as 35.30 14 508.32
specified. KG

11 M & L for precast RCC M-25 (Design Mix) using 20 mm graded 4817.60 0.26 1252.58
crushed stone aggregate as in cover slab and the like set in CM CUM
(1:6) complete all as specified and directed.
Note :- Reinforcement work shall be measured and paid
separately under respective items of this schedule.

12 M&L for mild steel TMT bars 6 to 8mm dia Grade 500D in 49.10 28 1374.80
reinforcement cut to length bent to shape required including cranking KG
, bending spirally for hooping for columns, hooking ends and binding
with and including MS wire (annealed) not less than 0.9mm dia or
securing with clips complete all as specified and directed.

Total amount carried over to summary of Schedule `A` Part VI Total 3135.70

SUMMARY OF SCHEDULE ‘A’ PART- VI


Total brought forward from Ser Page No 31
18691.55

Total brought forward from Ser Page No 32


3135.70

Total amount of Schedule ‘A’ Part- VI carried over to BOQ 21827.25

Signature of contractor Asst Director (Contracts)


Date : For Accepting Officer
CA NO : CEJZ/JSLR/ OF 2017-2018 SERIAL PAGE NO 33(R)
SCHEDULE ‘A’ PART-VII
( AREA DRAINAGE )
Refer Note 13 on page No 17 for column 3, 7 and 8
S/No Description of item of works Rate per No of Amount
Unit (Rs) units (Rs)
requir
ed
1 2 4 5 6

1 M & L for Cement concrete (1:4:8) type D-2 using 40mm graded 2303.30 143 328220.25
stone aggregate as in foundation / bed concerete for drain complete CUM
all as specified and directed.

2 M&L for squared rubble stone walling Jodhpur type, brought upto 1711.70 473 809634.10
courses, well bonded, bedded and solidly hearted, built in CM (1:4) CUM
complete all as specified and directed.

3 Extra over stone masonry for hammer dressing to face stones with 79.30 1140 90402.00
maximum depression on face from a straight edge held against the SQM
dressed surfaces not exc 20 mm and dressing face beds and joints
as specified to squared rubble walling, Jodhpur type,brought upto
courses complete all as specified and directed.

4 M&L for flush pointing in CM (1:3) over squared rubble stone walling 302.50 124 37510.00
Jodhpur type,brought upto courses complete all as specified and X SQM
directed.

5 M&L for PCC 1:3:6 type C-1 using 20mm graded aggregate copings, 3656.70 36 131641.20
kneelers, apex stones, bed plates, water throughs and like including CUM
weathering, slightly rounded or chamfered angles and throating
including necessary form work complete all as specified and directed.

6 M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate 3136.50 29.00 90958.50
as in surface channels / drains, and benching including finishing top CUM
of benching even and smooth using extra cement complete all as
specified and directed.
Note: - Forming fair finished channel shall be measured and
paid separately.
7 Extra for forming fair finished drain or channel 30 cm inner girth in 14.90 950 14155.00
cement concrete using extra cement including forms, moulds, RM
mitred/stopped ends etc. complete all as specified and directed.

8 Add to or deduct from item No 7 for forming fair finished channels or 1.90 For adjustment only
drains for each 25 mm girth or part thereof over or under 30 cm RM
complete all as specified and directed.
NOTE: - This item is only for adjustment of rate if applicable.

11 M & L for precast RCC M-25 (Design Mix) using 20 mm graded 4817.60 0.95 4576.72
crushed stone aggregate as in cover slab and the like set in CM (1:6) CUM
complete all as specified and directed.
Note :- Reinforcement work shall be measured and paid
separately under respective items of this schedule.

Total amount C/O to summary of Schedule `A` Part VI Total 1507097.77


CA NO : CEJZ/JSLR/ OF 2017-2018 SERIAL PAGE NO 34 (R)
SCHEDULE ‘A’ PART-VII (Contd….)
(AREA DRAINAGE)
Refer Note 13 on page No 17 for column 3, 7 and 8
1 2 4 5 6

12 M&L for mild steel TMT bars 6 to 8mm dia Grade 500D in 49.10 198 9721.80
reinforcement cut to length bent to shape required including cranking KG
, bending spirally for hooping for columns, hooking ends and binding
with and including MS wire (annealed) not less than 0.9mm dia or
securing with clips complete all as specified and directed.

Total amount carried over to summary of Schedule `A` Part VI Total 9721.80

SUMMARY OF SCHEDULE ‘A’ PART- VII


Total brought forward from Ser Page No 33
1507097.77
Total brought forward from Ser Page No 34
9721.80

Total amount of Schedule ‘A’ Part- VII carried over to BOQ 1516819.57

Signature of contractor Asst Director (Contracts)


Date : For Accepting Officer
CA NO : CEJZ/JSLR/ OF 2017-2018 SERIAL PAGE NO 35(R)
SCHEDULE ‘A’ PART-VIII
( SECURITY FENCING & GATE )
Refer Note 13 on page No 17 for column 3, 7 and 8
S/No Description of item of works Rate per No of Amount (Rs)
Unit (Rs) units
require
d
1 2 4 5 6

1 M&L for PCC (1:4:8) type D-2 using 40 mm graded crushed stone 2303.30 38 87525.40
aggregate in foundation, filling and mass concrete complete all as CUM
specified and directed.

2 M&L for PCC (1:3:6) type C-2 using 40 mm graded crushed stone 2579.00 107 275953.00
aggregate in foundation, filling and mass concrete complete all as CUM
specified and directed.

3 M&L, Pre-cast cement concrete block masonry with solid block of 3150.80 34 107127.20
PCC (1:4:8) type D-1 (using 20 mm graded stone aggregate), CUM
exceeding 10 cm in width and set in CM (1:6) complete all as
specified and directed.

4 M&L for PCC 1:2:4 type B-1 using 20mm graded aggregate 4144.40 38 157487.20
copings, kneelers, apex stones, bed plates, water throughs and CUM
like including weathering, slightly rounded or chamfered angles
and throating including necessary form work complete all as
specified and directed.
5 S&F Mild steel work conforming to Fe 290 (Gde E-165) in fencing 70.30 11982 842334.60
posts including cutting tops to shape as directed & struts, fillets for KG
securing chain link fencing etc. including all necessary drilling,
bolting or riveting, etc and similar work complete all as specified &
directed.
6 Supply only chain link mild steel galvanised fencing of 100 67.00 3003 201201.00
x100mm size with 3mm dia wire complete all as specified & KG
directed.

7 Fixing only chain link fencing including line wires, any mesh , size 4.20 2100 8820.00
and type to any type of standards, rails, straining bolts etc SQM
including provision of binding wire complete all as specified &
directed.
8 Supply only mild steel round bars conforming to Fe 290 (Gde E- 40.50 3085 124942.50
165) 10mm dia as line rows for securing chain link fencing KG
complete all as specified & directed.
Note : Cost of cutting to length, bent to shape required &
binding with MS wire is included in the above rate.

9 S&F mild steel screw bolts (machine made ) with hexagonal or 93.00 436 40548.00
square heads at one end and screwed the other, or screwed both KG
ends, each screwed end to be fitted with washers and one
hexagonal or square nut, exc 10 cm but n.exc 15 cm long &
diameter of neck 11 to 15 mm complete all as specified &
directed.

Total amount of Schedule ‘A’ Part- VIII C/O to Summary Rs 1845938.90


CA NO : CEJZ/JSLR/ OF 2017-2018 SERIAL PAGE NO 36 (R)
SCHEDULE ‘A’ PART_VIII
( SECURITY FENCING & GATE )
Refer Note 13 on page No 17 for column 3, 7 and 8
1 2 4 5 6

10 S&F galvanised 2 strand, steel barbed wire 2.24mm dia barbed 810.00 50 40500.00
with 2mm dia barbs at 75mm spacings and straining and fixing to 100 RM
any type of standard rails straining bolts, including, securing or
tying at crossings with and provision of galvanised mild steel wire,
staples or steel pins etc (each line wire to be measured) complete
all as specified & directed.

11 M & L for preparing new steel surfaces of any description 58.20 285 16613.77
exceeding 10 cm width or girth and applying two coats of SQM
synthetic enamel paint over a coat of red oxide primer complete
all as specified & directed.
12 Preparing surface of wood and wood based materials steel and 9.10 78 709.80
iron work or old of any description and girth not otherwise SQM
described and treated with tar or coal tar paint all as specified and
directed.
13 M&L Steel gate 5.50 metre wide and 2 m high in double leaf 74900.00 1 74900.00
including pillars in RCC M-25 design mix using 20 mm graded EACH
stone aggregate, excavation and earth work any in soft / JOB
disintregated rock, form work, reinforcement steel, preparation of
new plastered surface of wall and applying two coat of cement
base paint, painting to steel surfaces with two coats of synthetic
enamel paint over a coat of red oxide primer complete all as
specifed, shown on Drg No TD/2004/13 Sht 1/3 to 3/3 & directed.

Total amount of Schedule ‘A’ Part- VIII C/O to Summary Rs 132723.57

SUMMARY OF SCHEDULE ‘A’ PART- VIII

Total brought forward from Ser Page No 35 1845938.90

Total brought forward from Ser Page No 36 132723.57

Total amount of Schedule ‘A’ Part- VIII C/O to BOQ 1978662.47

Signature of contractor Asst Director (Contracts)


Date : For Accepting Officer
CA NO : CEJZ/JSLR/ OF 2017-2018 SERIAL PAGE NO 37 (R)
SCHEDULE ‘A’ PART-IX
( EXTERNAL WATER SUPPLY )
Refer Note 13 on page No 17 for column 3, 7 and 8
S/N Description of item of works Rate per No of Amount (Rs)
o Unit (Rs) units
requi
red

1 2 4 5 6

1 Supply and laying in trenches galvanised iron tubing, medium grade with and
including all galvanised steel fittings such as sockets, elbows, bends,tees,
reducers, short pieces, unions, caps, plugs etc. including connection
complete all as specified and directed of following sizes:-

(a) 25 mm dia bore. 214.90 100 21490.00


RM
(b) 50 mm dia bore. 415.90 700 291130.00
RM
(c) 80 mm dia bore. 601.10 300 180330.00
RM
2 S & F Gun-metal, globe or gate valves, with iron wheel head, screwed both
ends for iron pipe and fixed on bore dia of following sizes.

(a) 25 mm dia bore. 413.80 10 4138.00


EACH
(b) 50 mm dia bore. 893.10 5 4465.50
EACH

Total amount of Schedule ‘A’ Part- IX carried over to BOQ 501553.50

Signature of contractor Asst Director (Contracts)


Date : For Accepting Officer
CA NO : CEJZ/JSLR/ OF 2017-2018 SERIAL PAGE NO 38(R)
SCHEDULE ‘A’ PART-X
( EXTERNAL ELECTRIFICATION )

Refer Note 13 on page No 16 for column 3, 7 and 8


S/No Description of item of works Rate per No of Amount (Rs)
Unit (Rs) units
require
d

1 2 4 5 6

1 Supply, install, testing and commissioning lightening arrestor, out 9865.00 2 19730.00
door, non linear resist stn type line discharge class-3 nominal SET OF
discharge current 10 KA & high current with stand 100 KA THREE
assembly suitable for 36 KV including all clamps, nuts and bolts,
washers and connection complete all as specified & directed.

2 S&F GI tubing “light grade”, 100 mm bore, ISI marked, at road 763.50 20 15270.00
crossing/floor/wall/ on pole for protection of cables, duly sealed RM
at both end after drawing cable including necessary clamps,
saddles etc complete all as specified & directed.

3 M&L for sand cushioning to under ground cable using tibba sand 678.20 13 8816.60
and gently punning to cushioning to cable complete all as CUM
specified and directed.
Note:- For the purpose of payment only punned thickness
will be measured.
4 M & L for plain cement concrete (1:4:8) type D-2 using 40 mm 2303.30 41 94435.30
graded stone aggregate in foundation of pole / strut etc including CUM
necessary form work complete all as specified and directed.

5 M & L for plain cement concrete (1:2:4) type B-1 using 20 mm 3939.90 5 19699.50
graded stone aggregate for coping / encasing around of pole CUM
including necessary form work finished even and smooth without
using extra cement all as specified and directed.
Note for item No. 4 to 5:-
Volume of pole / strut / stays embedded in concrete shall be
deducted for the purpose of payment.

6 Earth continuity conductor or mainearthing lead fixed to pole on 132.10 40 5284.00


battenor recess or chases or buried in ground or drawn in EACH
conduit/pipe or fixed to poles or any other indicated situation for
loop earthing etc. as required 2mm dia galvanised iron or
steel wire,but 32x6mm galvanised iron
strip

Total amount of Schedule ‘A’ Part-X carried over to Summary Rs 163235.40


CA NO : CEJZ/JSLR/ OF 2017-2018 SERIAL PAGE NO 39(R)
SCHEDULE ‘A’ PART-X
( EXTERNAL ELECTRIFICATION )
Refer Note 13 on page No 16 for column 3, 7 and 8
1 2 4 5 6

7 Supplying, install and erect in true vertical position pre-stressed 5437.00 40 217480.00
cement concrete pole 11 metre long, 152 x 152 mm at top and EACH
152 x260 mm at bottom (or nearest higher size as approved by
State Electricity Board), Class-9 conforming to IS- 1678 for
erection of 2 pole structure including painting alternate white &
black strips 30cm high & 5 No with two coats of synthetic enamel
paint over a coat of primer complete all as specified and
directed.
8 S & F stay assembly using GI stay rod of 20 mm dia complete 834.00 20 16680.00
with accessories as shown in electrical plate No. 1 of SSR part I EACH
including loop type insulator and stay clamp, stay plate mild steel
of size 30cmx30cmx6mm thick, complete all as specified and
directed.
NOTE: Excavation & PCC shall be measured and paid seperately.

9 M & L for galvanised stay strand wire 7/ 3.15 mm or 7/4.00mm 5914.00 2 11828.00
dia including necessary binding with insulator, clamp and stay QUINTAL
clamp complete all as specified and directed.

10 Supply, stringing, streaching & binding with insulator, aluminium 19168.00 16 306688.00
conductor steel reinforced (ACSR) on pole, stringing properly on QUINTEL
insulators and binding with aluminium binding wire, jumpers etc
complete for any size ( Mink, Dog, Ferret, Weasel, Squirel of
conductor) complete all as specified and directed.

Note: - Measurement & payment shall be made by measuring


horizontal distance between centre of two adjacent pole by
adding 3% extra for sag, joints and jumper etc.
11 Supply fabricate, fixing anti climbing device spike type of MS 6398.00 3 19194.00
bars ( round square or flat ) including nuts, bolts, washers, and QUINTEL
welding in two halves made to shape to suit the cross section of
the poles including painting with two coats of aluminium paint
over a coat of red oxide primer.
12 M & L for galvanised steel wire 4.00mm dia as in earth conductor 6130.00 2.5 15325.00
including necessary binding with insulator, clamp and stay clamp QUINTAL
complete all as specified and directed.

Total amount of Schedule ‘A’ Part-X carried over to Summary Rs 587195.00


CA NO : CEJZ/JSLR/ OF 2017-2018 SERIAL PAGE NO 40(R)
SCHEDULE ‘A’ PART-X
( EXTERNAL ELECTRIFICATION )
Refer Note 13 on page No 16 for column 3, 7 and 8
1 2 4 5 6

13 M&L for danger notice plate of 1.6 mm thick mild steel sheet , 108.00 30 3240.00
vitreous enamelled white, with letters, figures and conventional EACH
skull and bones in signal red colour and fixed with M S clamps,
bolts and nuts of approved size 25x 20 mm for HT 33/11 KV
complete all as specified & directed.

14 Supply & fixing cross arms, bracing, supports clamps including D 8584.00 40.00 343360.00
clamps, eye hook and back plate etc fabricated from structural QUINTEL
steel section including nuts , bolts, washers, welding (cold and
hot ) drilling holes for bolts, bend to any shape or size as
indicated and directed, inclusive of one primer coat and two coats
of aluminium paint after preparation of surfaces complete all as
specified and directed.
15 M & L for plain cement concrete (1:3:6) type C-2 using 40 mm 2579.00 11.00 28369.00
graded stone aggregate in foundation of pole / strut etc including CUM
necessary form work complete all as specified and directed.

16 M&L for loop porcelain, vitreous white, brown or green insulator 45.00 20.00 900.00
with over all dimension of 90mm x 140mm clearance of whole CUM
25.5mm complete
Total amount of Schedule ‘A’ Part-X carried over to Summary Rs 375869.00

COLLECTION OF SCHEDULE 'A' PART -X


Total Amount brought forward from Sl Page No.38= Rs. 163235.40
Total Amount brought forward from Sl Page No.39= Rs. 587195.00
Total Amount brought forward from Sl Page No.40= Rs. 375869.00

Total Amount of Schedule 'A' Part-X carried over to BOQ= Rs. 1126299.40

Signature of contractor Asst Director (Contracts)


Date : For Accepting Officer
CA NO : CEJZ/JSLR/ OF 2017-2018 SERIAL PAGE NO 41(R)

SCHEDULE ‘A’ PART-XI


( MISC. ITEMS ) (REFER BOQ)

Refer Note 13 on page No 17 for column 3, 7 and 8


S/No Description of item of works Unit Rate per Unit No of Amount
in figure and units (Rs)
words (Rs) required

1 2 3 4 5 6
Note: (i) The items under this schedule will be refered under item No. 11.00 to 57.05 of BOQ.

(ii) Quotation shall be done for these items in BOQ

Signature of contractor Asst Director (Contracts)


Date : For Accepting Officer

You might also like