You are on page 1of 6
SHINWA COOLING TOWER, SHINWA COOLING TOWER CROSS FLOW SQUARE TYPE SERIES @ SNC-U MODEL U - Energy saving - Space saving - Compact design - High efficiency and performance | / snc-u MODEL cross Flow square TYPE) NS 4 ‘The above drawing shown is external piping type (ASSY) Feature Energy Saving, Space Saving Compactness and Lightweight “SNC-U” model is designed to install in a small space, ‘Compare with other model, SNC model isthe best one for space limited installation. New development such as high efficeiency fill ype eliminator combined and cone shaped fan casing are incorporated. Combination of super low noise fan type AVS reduction in installation space and volume as well as dry & wet weight by 20% in average compared with our old models. Built - in Piping Arrangements “U” series cooling towers are supplied with built-in piping arrangements as standard. The result is cost and space saving in the installation work. 3 Easier Maintenance ‘A new speed reducer SRS with wedge belt is compact and ‘easy for maintenance. Also FRP lower basin is sloped for ‘easy cleaning. (Photo shown is at the time of belt cover removed) Reduced Installation Time Delivery can be made in semi assembled unit form at site fon request. The installation time at site can be greatly reduced by this method. re ies (Space saving) For chiller other applications a cannes a LUN we © Selection - Standard Specifications - Noise Level Other voltages such as 380, 418V are available on request | 2960 | 13960 | 1800 | 75 ep | a | 4 | 75 | eos | o2 | S05 | 055 | sas | 55 Ti [se fee [2m [7s fafa es fe fn fos a) ss | | 6890 14990 | 2100 | 11.0 4 BD 213 76 72 645 61 68 61 57.5, ater inet, Out=Water outlet, Oi 8D=Belt drive, Amp=Rated current, Dr 1120ASSD | 11338 |__ 1280ASsD | 12976 | _1400aSSD | 14498 3790 | 645 | 150 | 160 | 60 | 60 3780 | 718 | 150 | 150 | 50 | 50 3730 | 715 | 160 | 160 | 50 | 50 HeHeight Specification Weight (kg)| Motor for fan Noise Level dB (A) Menon) (Le | CN senetiene fant Piping Size (A) es 3PH x 400V x 50Hz % Fan | Louver Side | Casing Panel Side Outlet Temp.(°C) | 32.2 | 29.5 =| 2 48 H=1.5m. H=1.5m. WB. Temp.('c) | 283 | 27 | &| & | oi Amo —a kw] P | Dw Qty | Dm | 2m }10m] 16m] 2m] 10m] 16m | Model No. [water iow wimim)| L | WH | h | in [out] ovfor|sa[malaw] mm 6 a) [snc-uzsoassy | 2634 | 1988 | 3670 | 2180 | 3700 | eu | - | 150 | 60 | 50 | 32 | a2 | 1 1200 | 3300 | 1800 / 75 | 4 | so | 163 | 1 | 7 | | 575 | 53 | 61 | 54 | 505 | szoassy| zea | 2275 | 3070 | 2350 | 3700 | 715 | - | 160 | 60 | 50 | 32 | a2 | 1 _| | 1400 | 9760 | 2100 | 75 | 4 | 80 | 3 | 1 | 715) 665 59 | 655 | 625 | 855 | 82 _ssoassy| 2622 | 2640 | 3870 | 2350 | 3790 | 715 | - | 180 | 50 | 50 | 32 | a2 | 1 1440 | 3790 | 2100) 10 | 4 | > | 23 | 1 | 25) 675 | 6 | S65 | 3s | oss | | __seoassy| 5002 | 2076 | a570 | «300 | s7o0 | oa | - 160 60 | 60 2 | 2 | 2, 7060 | 6650 | 1800| 75 | 4 | 8 | 169 2 |” | 6 | 805/86 | 69 | 66 | S25 | eeoassy| 62 | 4550 | ca70 | «700 | 3790 | 75 | = | ts0] 60 | 60) | a | 2 2e00 | 7300 | 2100/75 | 4 | @> | 163) 2 | 7% | @ | es | | es | se | os | rooassy | 7244 | 060 | sa70 | 2700 | a700 | 715 | - | 150| 50 | 50 | | x | 2 | [aro | v0 | 200 [ 10 | « | eo | 23 2 | % | 0 | es | 5 | 6 | 59 | ss | eaoassy | 8602 | 5964 | 3570 | 6450 | 3700 | 645 | - | 150 | 50 | 50 | 32 | 32 | 3 a 3620 | 9920 1800] 75 | 4 | BD | 63 | 3 | 73 | 6 | S| 57 | OF | 57 | 635 BH} © s60assy | 9772 | 6825 | a70 | 7050 | 3700 715 | - «160 60 60 | 2 | 2 | 3 3980 | 11090 | 2100 | 75 | 4 | 8p | 163 3 | 75 | 7 | 625 | 59 | 68 | 59 | 585 | to50assy | 10800 | 7620 | 870 | 7050 | a700 | 715 | - | 150 | 50 | 60 | a | a | a 400 | 11160) 2100 [ 110 | 4 | 80 | 23 3 | m5 | 7m | 635 | eo | 67 | 60 | 865 | __avzoassy | 116 | 7952 | 2670 | 9600 | 3700 | om | - | 150/60 | 60 | 2 | a | 4 4700 | 13100 | 1600 | 75 | 4 | 80 | 163 4 | 75 | 695 | 2 | 585 055 | S05 | 66 100 | 3870 | 400 | 3700 | 715 | - | 150) 60 | 50 | a2 | a2 | 4 270 | 14670 | 2100| 75 | 4 | BD | 163 | 4 | 7% | 71 | 65 | 6 | 67 | 565 tore | 3670 | 9400 | 3790 | 715 | - | 150) 60 | 0 | 32 | a2 | 4 [ 530 | 14890 | 210 | 110 | 4 | so | 213 | 4 | 7% | 2 | 05) ot | ca | or | 575 vee os 7180 | aen | wS »)2|2[1) 0 | seo [imo | 75 # |e [ws 1 | me) ese pepe) as 2275 | 3870 | 2350 | 3790 | 715 60 | 32 | 32] 1 1480 | 3800) 2100 | 75 4 8D | 163) 1 m5 | 65 | 69 | 5 625 | 555 | 52 2540 3870 | 2350 | 3790 | 715 80 | 32 | 32 1 1480 | 3830} 2100 | 10 | 4 BD a3 1 725 | 675 | 60 565 | 635 | 665 | 63 3976 | 3670 | 4300 | 3790 | 645 | 180 | 160 | 60 | 50 - 250 | 6740 | 190] 75) 4 | Bo | 163] 2 | 2 | 6 | 595| 8 | 63 | 86 | 525 4550 | 3870 | 700 | 3790 | 716 | 160 150) 50 | 60 . 270 | 7490/2100 | 75 | 4 | BD | 163 | 2 | m | 69 | 615 | se | 6 | 6B | 545 |_7ooassp | 7244 | 080 | 070 | 4700 | 3700 | 718 | 150 160 | 60 | 50 250 | 7550 | 2100) 1.0 | 4 | a> | 23 | 2 | 7% | 7 | 25) 5 | 06 | 69 | 555 3790 | 645 | 150 | 150 60 | 50 a 3760 | 10050] 1800 75 | 4 | 8 | 169] 9 | 7 | 68 | OOH] 7 | o | a | B35 f 3790 | 715 | 150, 150 | 60 50 ao | 11160 | 2100 | 75 | 4 | BD | 163 | 3 | 745 | 70 | a5) 59 | 06 | 59 | 555 3790 | 715 | 150 | 150 | 60 | 50 a azo | vm | 200] no | 4 | 8 | 3 | 3 | m5) m | os | oo | 7 | wo | 665 4 4 8 4 © a Fan Casing Height ver flaw, Dr=Drain, Ba=Auiomate makeup, Me=Manval makeup, Drv=Driving method, Fan diamater point 'S (Space saving) @ Schematic Drawings - Piping & Anchor Bolts Positions (mm) | | 600 |2050) 750 2260) ~ 750 |2260) - | Bolts Position SNC-U280~1400ASSY/ASSD 11900) 11900 1600 |205012180)1600| 750 |2250/2360) ‘750 |2250) 1360 600 (205012150 750 (2250|2350) 750 |2260)2360| 600 (205012150) 750 [2260 ia La I 11900 a 1900 aerate me op i) "609 let 95 rt Pl 11900) i900) 750 |2260|2360)1900 "The shove dwing shown i intemal piping ype CASSD) Pu. Series optional parts (@) HANDRAIL & CAGE LADDER case LaboEn —— @ UPPER WATER BASIN COVER (F.R.P. or H.D.G. Steel) Protect from invation of dust into the upper basin, + inlerrupt sunlight which is causing algae glowth tw OTHER OPTION PARTS 1, ERP. Duct (Straight . Elbow) 2. Partition 3. Additional eliminator (P.V.C.) 7 ee eee EBARA SHINWA gives answers to any of your ae request with our variety of selection nee he * Cross flow type (SNC-R} A Precautions for safety Cooling towers described in this catalog are of our standard specifications. m Before use . Before use, read the “Instruction Manual” carefully and use the towers correctly @ Before installation @Request installation from the distributor or professional agency. Otherwise, improper installation ‘work may cause toppling, water leakage, electric shocks or fire which will endanger operations. @Make sure to use extra-cost options such as an electric heater designated by us, request installation from the distributor or professional agency. Otherwise, improper installation work might cause toppling, water leakage, electric shocks or fire which will endanger operations. Space is required for maintenance work around the machine. lack of space may obstruct safety work and cause injuries. @ Location for use @Do not install in places where combustible gases leak of flammables exist. ‘Fire may occure in places where flammable gases are generated, flow in or are retained, and ‘carbon fibers are floated, ™ Maintenance and inspection ‘Periodic maintenance and inspection is required other than inspections for daily operation. ‘elmproper maintenance and inspection may cause a fire, electric shocks and burns. ‘@As maintenance and inspection requires special skills, consult manufacturer or distributor Notice for water quality control IF the cicculating water is lft as iti, slime deposits in the water bath and piping will develop. The slime is formed from many kinds of algae and fungi, particularly, metabolic products from algae sometimes belp fungi grow. Disease-causing bacteria among bacteria may also exis, therefore, please be advised to clean or control the water quality at least once a month to prevent algas from forming. © Your Contect (Agent) = EBARA SHINWA ur. EaARA ‘Speciation lsc i tis Brochure ae wubjet to change without nice doe fo technical improvement on our produe ASEC-001

You might also like