NOSE RADOME - INSPECTION/CHECK
1. General
A. The nose radome requires a check for security of installation
and a check for evidence of lightning strikes (Ref 5-51-151 ).
2. Equipment and Materials
A. Detector - Moisture Register (Model: A8-AF; P/N: MRC 005574),
Penta Engineering, Moisture Register Products, P.O. Box 369,
LaVerne, CA 91750-0369, phone (714) 392-5833, Fax (714)
392-5838
B. Milliohmmeter - O to 0.1 ohm range
3. Check Fiberglass Dome
A. Check for holes, scuffs, cracks, blisters, and delamination.
NOTE : Delamination can be detected by tapping the radome skin
with a small metallic object. For example, a short
socket extension.
(3) Open radome and position gun part of register so that gun
electrodes contact inner surface of radome. Make sure all
eight electrodes contact radome surface.
(4) Move gun over entire inner surface of radome and observe
meter on case.
(a) Meter indication must stay within GOOD (0-5) range.
RADOME CONDITION COLOR NUMERICAL SCALE
Good Green O to 5
Fair Yellow 5 to 10
Poor Orange 10 to 20
Unacceptable Red 20 to 50
B. Check conductivity.
(1) With radome open, measure resistance between heel of
diverter strips (end closest to bulkhead) and metal
bulkhead. Resistances should be 0.1 ohm or less. A test
probe with a sharp tip should be used to penetrate paint
or epoxy on strip.