You are on page 1of 1

750

150 450 150


4 NO'S 16# 4 NO'S 16#
6 NO'S 16MM RODS FIX WITH LOCKSET
EXISTING RCC PEDESTAL
150MM DEEP IN TO BOTH SIDES
OF EXISTING PEDESTAL
7000 C/C

D B EXISTING RCC BEAM

600
150 150
P.B1

450

800
EXISTING BEAM 3 NO'S 12#

C A
8#@150C/C-3 RINGS
PLAN

200
6 NO'S 16MM RODS FIX WITH LOCKSET
150MM DEEP IN TO BOTH SIDES 8 NO'S 20#
2 NO'S 16# ON EACH SIDE OF EXISTING PEDESTAL SECTION A-B RINGS
2 NO'S 16# ON EACH SIDE 8#@100C/C
3 NO'S 12# ON EACH SIDE
PB1- 750X800
EXISTING RCC BEAM

600
200
6 NO'S 16MM RODS FIX WITH LOCKSET
8 NO'S 20# 750 150MM DEEP IN TO BOTH SIDES
OF EXISTING PEDESTAL
150 450 150 TO SUPPORT BEAM RODS

600
EXISTING RCC PEDESTAL

800
7000 C/C

200
ELEVATION

SECTION C-D
ALL DIMENSIONS ARE IN MM

KSA CONSULTANTS 33, P A N C O M C H A M B E R S,


RAJ BHAVAN R O A D,

PRIVATE LIMITED
SOMAJIGUDA, HYDERABAD - 82.
PH. : 331 0559, FAX : 339 7509.

M/S.MERGE STONES, NORTH


CLIENT SITUATED AT SHADNAGAR
HYDERABAD, TELANGANA.

TITLE STRENGTHENING OF GANTRY


SCALE NTS

DRAWN VLN DATE 25-07-18

DRG
DESIGNED BKS NO: 150A