Professional Documents
Culture Documents
CONDITIONS OF LOAD
1.1 PV Value
PV value is an important parameter to decide suitable bush. Amount of friction thermal energy
“Q” which occurs on unit area during unit time can be calculated from loss of energy, pressure and
velocity by using below equation ;
Q = μ * P * V /J
When applying plating for the purpose of above article 1), high hardness Chromium plating is
strongly recommended, because it protects relative material from rusting and abrasion and
improves sliding.
Model Housing Pin diameter Bush inner diameter Bush outer diameter
GWPB H7 f8 C9 u6
GWGB H7 f8 C9 u6
GWFL H7 f8 C9 u6
GWCH H7 h7 C8 u6
GWIG H7 h7 C8 u6
GWHB H7 f7 H9 p6
GWOL H7 f7 H9 p6
GWSN H7 f7 H9 p6
The design of operating clearance for pin and bush is the most important due to be maintained
optimal clearance for the formation of oil film.
The change of size owing to the operational heat and the reduction of inner diameter after fitting
the bush into housing has to be considered carefully to decide the operating clearance.
This clearance can be changed according to the various fitting conditions and shape of bush,
i.e. interference of bushing and housing, the shape of boss and groove of bush, flanged bush and
various material and heat treatment, etc. So it is not easy typically to fix the clearance.
For just reference, the clearance of bush and pin is used about 0.1~0.3mm commonly.