You are on page 1of 36

MEDIUM VOLTAGE

EQUIPMENT BUSHINGS
CATALOGUE 2017
NEXANS NETWORK SOLUTIONS DIV. EUROMOLD

COMPANY PRESENTATION

EUROMOLD International standards Laboratory accreditation


Nexans is the leading European All our products meet the Since June 2000, Nexans'
specialised designer, manufacturer International standards like independent ELAB laboratory
and distributor of prefabricated CENELEC HD 629.1, CENELEC EN obtained the BELAC accreditation
cable accessories for medium 50180, IEC 60137, IEC 60502- no.144-TEST conform with
voltage energy distribution. 4… or country specifications. the European standards for
Under its tradename Euromold, Official certificates, CESI, KEMA, laboratories ISO 17025 for
it provides a complete range ATEX… prove the conformity of electrical testing of low and
of accessories for underground our products. Long duration tests medium voltage cable accessories
cables: premoulded EPDM of existing or new products are according to the international
rubber connectors for cables and continuously performed in our test standards EN 50393, IEC 60502-
epoxy bushings for transformers fields. 4, IEC 61442 and HD 629.
and switchgear, as well as a
large range of cold-shrinkable
terminations and joints from 12 to
42 kV.
Nexans division Euromold is also
the manufacturer of electrical
components for the high voltage
accessories of the Nexans group.

ISO 9001 Certificate


Since 1992, Nexans'
commitment to quality is
demonstrated by its ISO 9001
certification. We are also certified
in the important sectors of
environmental protection and
occupational safety.

While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility
can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or
modify the characteristics of its products described in this catalogue as standards and technology evolve.
EQUIPMENT BUSHINGS

TABLE OF CONTENTS
180AR-1 - interface A1 equipment bushing
180AR-2 - interface A1 equipment bushing
180AR-3 - interface A1 equipment bushing
180A-24P-O - interface A1 in-air bushing
400T1 - interface B2 equipment bushing
400AR-1 - interface B2 equipment bushing
400AR-2 - interface B2 equipment bushing
400AR-8 - interface B1 equipment bushing
400SFR-P - interface B2 equipment bushing
400AR-3 - interface C1 equipment bushing
400AR-4 - interface C2 equipment bushing
400AR-5 - interface C2 equipment bushing
400AR-6 - interface C1 equipment bushing
400SFR-B - interface C2 equipment bushing
400A-24B - interface C1 in-air bushing
670AR-2 - interface D2 equipment bushing
900AR-1 - interface F3 equipment bushing
900AR-2 - interface F2 equipment bushing
900AR-3 - interface F1 equipment bushing
900AR-4 - interface F1 equipment bushing

09/2017
DIMENSIONS & RATINGS
OF EQUIPMENT BUSHINGS
DIMENSIONS
These diagrams show the
dimensions of the interfaces of
equipment bushings according to
CENELEC standards Dia. 56±0.2
EN 50180:2010 and Dia. 56±0.2 Dia. 46±0.2
EN 50181:2010. Dia. 46±0.2 Dia. 22 min for C1
Dia. 32 nominal for C2
Dia. for
0
pin 14 -0.04 M16 x 2 - 6H 0
1.5 -0.5

Dia. 32.5±0.2

Dia. 31+0.1
- 0.3
29
40 min
Dia. for min
+0.02
pin 7.9 - 0.05

90±0.2 90±0.2
0
48 -0.2

9
min
11 11
min min
Dia. 48.5±0.2

Dia. 70±0.2 Dia. 70±0.2

Interface A1 Interface B1 & B2 Interface C1 & C2

Dia. 86.8±0.2

Dia. 64±0.2
Dia. 52.1±0.2 Dia. 50 min for F1
Dia. 22 nominal for F2
Dia. 39.9±0.2 Dia. 32 nominal for F3
M16 x 2 - 6H
Dia. 32 0
1.5 -0.5
nominal
M16 x 2 - 6H
0
1.5 -0.5 29
min

29
min

81±0.2 110.5±0.2

14.8
min

Dia. 76.2±0.2

Interface D1 & D2 Interface F1, F2 & F3


In mm.
SHORT CIRCUIT RATINGS
Current rating RMS symm. (kA) Peak asymm.
Interface type Contact type
(A) 1 sec. 2 sec. 3 sec. (kA)

A1 Pin and socket 250 12.5 9.0 7.5 31


B1 Pin and socket 250 12.5 9.0 7.5 31
B2 Pin and socket 400 16.0 11.3 9.2 40
C1 Bolted 630 28.0 19.7 16.1 70
C2 Bolted 1250 75.0 53.0 43.3 >150
D1 Bolted 800 50.0 35.3 28.8 125
D2 Bolted 1250 75.0 53.0 43.3 >150
F1 Bolted 2500 - - - -
F2 Bolted 630 28.0 19.7 16.1 70
F3 Bolted 1250 75.0 53.0 43.3 >150
3

09/2017
180AR-1/180AR-2/180AR-3 INTERFACE A1
EQUIPMENT BUSHINGS

APPLICATION SPECIFICATIONS AND


For use in equipment insulated STANDARDS
with oil fluid, typically for The plug-in type equipment
transformers, switchgear, bushings 180AR-… meet the
capacitors... requirements of CENELEC EN
50180 and IEC 60137.
TECHNICAL
CHARACTERISTICS
Each bushing is tested for AC Type 180AR-1 /-2 /-3
withstand and partial discharge
prior to leaving the factory.

DESIGN
• The equipment bushings are 6/10 (12) kV
6.35/11 (12) kV
28

moulded epoxy insulated parts


in accordance with CENELEC EN
8
8.7/15 (17.5) kV
50180.
A
12/20 (24) kV
The 180AR-2 bushing has a 12.7/22 (24) kV
length B outside this standard. B

• The standard bushings, Minimum oil level:


- 12 kV: 40 mm
Dia.
16 Up to 24 kV - 250 A
(K)180AR-1 /-2 /-3, are - 24 kV: 50 mm

equipped with 6 tabs for the bail


19
restraint.
• The (K)180AR-1-G and Dia. 75
M10

(K)180AR-3-G are equipped with Dia. 110

4 tabs and 2 threaded inserts M6 Type 180AR-1-G /-3-G


(-G version).

ORDERING INSTRUCTIONS M6

To order the equipment bushing,


specify the type. 11

The bushings are supplied with an


earth jumper (/J) or an earth plate
(/GS). This earth connection must
be specified when ordering.
E.g. K180AR-1/J.
In mm.

Equipment Voltage Current Dimensions (mm)


bushing Um Ir
type (kV) (A) A B
180AR-1 12 250 222 106
K180AR-1 24 250 222 106
180AR-2 12 250 284 168
K180AR-2 24 250 284 168
180AR-3 12 250 171 55
K180AR-3 24 250 171 55 09/2017

4
FIXINGS FOR EQUIPMENT BUSHINGS
180AR-1/GS 180AR-1/J
180AR-1-G/GS 180AR-1-G/J
180AR-2/GS 180AR-2/J
180AR-3/GS AND 180AR-3/J AND
180AR-3-G/GS BUSHINGS 180AR-3-G/J BUSHINGS
bushing interface
fixing studs

NF C 52-053
clamp E DIN 42 538
stud clamp

equipment

sealing gasket

equipment
connection

A DIN 42 538
tabs for bail restraint fixing flange

earth jumper
earth plate

BUSHING CLAMPING KIT BUSHING CLAMPING KIT


To order the bushing clamping kit,
To order the bushing clamping kit,
according to DIN 42 538 stand-
according to NF C 52-053
ards, simply specify: KBCD-200.
standards, simply specify KBC-
Contents: - 1 x fixing flange A
NF1-200.
- 4 x stud clamp E
Contents: - 3 x claw clamp NF
- 1 x sealing gasket.
- 1 x sealing gasket.

FIXING DIMENSIONS FIXING DIMENSIONS


STANDARDS NF C 52-053 STANDARDS DIN 42 538
French standards. German standards.
M8 or
M10
M10

Min. 55 Min. 55
Max. 30 Max. 30

3 fixing 4 fixing 5
studs Dia. 78 studs Dia. 78
Dia. 126 Dia. 123 In mm.
180A-24P-O INTERFACE A1
IN-AIR BUSHING

APPLICATION TECHNICAL
For use in equipment insulated CHARACTERISTICS
with air, typically for dry type Each bushing is tested for
transformers, motors, switchgear, AC withstand and partial
capacitors... discharge prior to leaving the
factory.

SPECIFICATIONS AND
STANDARDS
The plug-in type equipment 59
bushings 180A-24P-O are
moulded epoxy insulated parts 6/10 (12) kV
and meet the requirements of 20 6.35/11 (12) kV
CENELEC EN 50181, IEC 60071 8.7/15 (17.5) kV
and IEC 60137.
Dia. 70
12/20 (24) kV
A
Dia. 110 12.7/22 (24) kV

Up to 24 kV - 250 A

ORDERING INSTRUCTIONS 351


To order the equipment bushing,
specify the type.
250
The bushings are supplied with an
earth jumper.
To include the ring clamp, add:
• /B, if per British standards
• /D, if per German standards
Dia.
• /F, if per French standards. 16
E.g. 180A-24P-O/F.

20

M10
B Dia. 80

In mm.

Equipment Voltage Current Creepage distance


bushing Um Ir A-B
type (kV) (A) (mm)
180A-24P-O 12 250 630
180A-24P-O 24 250 630
09/2017

6
FIXINGS FOR EQUIPMENT BUSHINGS
180A-24P-O IN-AIR BUSHING
bushing interface
fixing studs and
nuts M10
earth jumper

equipment

gasket

equipment
connection

fixing flange
fixing flange
BCA-B or
BCA-D BCA-F

tabs for bail


restraint
Dia.12 Dia.12
Dia. 94.5 Dia. 94.5
4 4
10 10
Dia. 111 Dia. 111

120°

126

120°
BS 2562 stand.: 120
DIN 42 538 stand.: 123 Dia. 150
Dia. 150
Type BCA-B : BS 2562 British standards Type BCA-F : NF C 52-053 French standards
Type BCA-D : DIN 42 538 German standards

FIXING DIMENSIONS FIXING DIMENSIONS


STANDARDS DIN 42 538 STANDARDS NF C 52-053
German standards. French standards.

M10 M10

Min. 55
Min. 55
Max. 20
Max. 20

4 fixing
3 fixing
studs 7
studs
Dia. 82
Dia. 82
In mm. Dia. 126
Dia. 123
400T1/400AR-1/400AR-2 INTERFACE B
EQUIPMENT BUSHINGS

APPLICATION TECHNICAL
For use in equipment insulated CHARACTERISTICS
with oil fluid, typically for Each bushing is tested for
transformers, switchgear, AC withstand and partial
capacitors... discharge prior to leaving the
factory.

SPECIFICATIONS AND
STANDARDS
The plug-in type equipment 6/10 (12) kV
bushings are moulded epoxy
103
6.35/11 (12) kV
insulated parts and meet the 8.7/15 (17.5) kV
requirements of IEC 60137. The 12/20 (24) kV
(K)(M)400T1 also meets CENELEC C
12.7/22 (24) kV
EN 50180 . 10
18/30 (36) kV
A Up to 36 kV - 400 A

ORDERING INSTRUCTIONS
Minimum oil level: Dia.
- 12 kV: 40 mm H
- 24 kV: 50 mm
To order the equipment bushing, - 36 kV: 75 mm
specify the type.
The bushings are supplied with an E
earth jumper (/J) or an earth plate
(/GS). This earth connection must D
Dia. 70
be specified when ordering. Dia. F
E.g. K400AR-1/J. Dia. G

In mm.

Equip- Dimensions (mm)


Voltage Current
ment
Um Ir
bushing
(kV) (A) A B C D E Dia. F Dia. G Dia. H
type
400T1 12 400 310 144 30 M12 22 88 128 16
K400T1 24 400 310 144 30 M12 22 88 128 16
M400T1 36 400 310 144 30 M12 22 88 128 16
400AR-1 12 400 380 213 30 M12 22 74 128 16
K400AR-1 24 400 380 213 30 M12 22 74 128 16
M400AR-1 36 400 380 213 30 M12 22 74 128 16
400AR-2 12 400 329 138 36 M16 40 100 150 30
K400AR-2 24 400 329 138 36 M16 40 100 150 30
M400AR-2 36 400 329 138 36 M16 40 100 150 30
09/2017

8
FIXINGS FOR EQUIPMENT BUSHINGS
400AR-2/GS BUSHING 400AR-2/J BUSHING 400AR-1/J AND 400T1/J
BUSHINGS
bushing
bushing interface interface
fixing studs
fixing studs

fixing flange
fixing flange B DIN 42 538

NF C 52-053 F DIN 42 538


stud clamp E DIN 42 538
claw clamp
stud clamp

equipment
equipment

sealing gasket
sealing gasket

equipment
equipment
connection
connection

tabs for the tabs for the


bail restraint bail restraint

earth
jumper
earth
plate
earth
jumper

BUSHING CLAMPING KIT BUSHING CLAMPING KIT BUSHING CLAMPING KIT


To order the bushing clamping kit, To order the bushing clamping kit, To order the bushing clamping
according to NF C 52-053 stand- simply specify: KBCDS-400B. kit, according to DIN 42 538
ards, simply specify KBCNF-400 Contents: - 1 x fixing flange standards, simply specify KBCD-
(for bushing type 400AR-2). - 6 x stud clamp F 400B.
Contents: - 4 x claw clamp NF - 1 x sealing gasket. Contents: - 1 x fixing flange B
- 1 x sealing gasket. - 6 x stud clamp E
- 1 x sealing gasket.

FIXING DIMENSIONS FIXING DIMENSIONS FIXING DIMENSIONS


STANDARDS NF C 52-053 STANDARDS DIN 42 538
French standards. German standards.

M10 or M12 M12 M10

Min. 55 Min. 60 Min. 55


Max. 30 Max. 30
Max. 25

6 fixing 6 fixing Dia. 90


4 fixing Dia. 105
Dia. 105 studs studs Dia. 140
studs
Dia. 171
Dia. 171 9
In mm.
400AR-8 INTERFACE B
EQUIPMENT BUSHING

APPLICATION TECHNICAL
For use in equipment insulated CHARACTERISTICS
with oil fluid, typically for Each bushing is tested for
transformers, switchgear, AC withstand and partial
capacitors... discharge prior to leaving
the factory.

SPECIFICATIONS AND
STANDARDS
The plug-in type equipment 6/10 (12) kV
bushings 400AR-8 are moulded 6,35/11 (12) kV
epoxy insulated parts and meet 8,7/15 (17,5) kV
the requirements of CENELEC EN 12/20 (24) kV
50180 and IEC 60137. 28 231.5 12,7/22 (24) kV
8.5
Minimum oil level: Dia.
- 12 kV: 40 mm
- 24 kV: 50 mm
20 80
Up to 36 kV - 250 A
- 36 kV: 75 mm

20

M10

ORDERING INSTRUCTIONS Dia. 74

To order the equipment bushing, Dia. 110

specify the type.


The bushings can be supplied
with an earth jumper (/J).
E.g. M400AR-8/J.

In mm.

Equipment Voltage Current


bushing Um Ir
type (kV) (A)
400AR-8 12 250
K400AR-8 24 250
M400AR-8 36 250

09/2017

10
FIXINGS FOR EQUIPMENT BUSHINGS
400AR-8/J BUSHING BUSHING CLAMPING KIT
To order the bushing clamping kit,
according to DIN 42 538 stand-
ards, simply specify: KBCD-200.
bushing interface Contents: - 1 x fixing flange A
- 4 x stud clamp E
- 1 x sealing gasket.
4 x fixing stud M10

A DIN 42 538
fixing flange
E DIN 42 538
stud clamp
equipment
sealing gasket
FIXING DIMENSIONS
equipment STANDARDS DIN 42 538
connection
German standards.

tabs for the


bail restraint

M10

Min. 55
earth jumper Max. 30

4 fixing
studs Dia. 78
Dia. 123

In mm.

11
400SFR-P INTERFACE B
EQUIPMENT BUSHING

APPLICATION TECHNICAL
For use in equipment insulated CHARACTERISTICS
with SF6 gas. Each bushing is tested for
AC withstand and partial
discharge prior to leaving the
factory.

DESIGN Dia. 70
The equipment bushing is a
moulded epoxy insulated part with 6/10 (12) kV
a connector interface in accordance 6.35/11 (12) kV
with CENELEC EN 50181. 8.7/15 (17.5) kV
The 400SFR-P bushing has a shank 12/20 (24) kV
outside this standard, adapted for 12.7/22 (24) kV
use in SF6 gas.
218
Up to 24 kV - 400 A
SPECIFICATIONS AND
STANDARDS 33
The plug-in type equipment
bushing 400SFR-P meets the
requirements of CENELEC EN
50180 and IEC 60137.

95
ORDERING INSTRUCTIONS
To order the equipment bushing,
simply specify the type.

M12
Dia. 25
Dia. 70
Dia. 109

In mm.

Equipment Voltage Current


bushing Um Ir
type (kV) (A)
400SFR-P 12 400
K400SFR-P 24 400
09/2017

12
FIXINGS FOR EQUIPMENT BUSHINGS

400SFR-P BUSHING FOR GAS


INSULATED SWITCHGEAR

UNMOUNTED
earth
60° connection
M4

60° 60°

30°

83

M6

Dia. 91.5
Dia. 103.1

equipment
MOUNTED
Dia. 4

97.5

Dia. 100

equipment
connection

earth
connection
bail sealing M4 In mm.
tab O-ring
gasket
6 fixing
screws
M6

13
400AR-3 INTERFACE C1
EQUIPMENT BUSHING

APPLICATION TECHNICAL
For use in equipment insulated CHARACTERISTICS
with oil fluid, typically for Each bushing is tested for
transformers, switchgear, AC withstand and partial
capacitors... discharge prior to leaving
the factory.

SPECIFICATIONS AND
STANDARDS
The bolted type equipment
6/10 (12) kV
bushings 400AR-3 are moulded 133
6.35/11 (12) kV
epoxy insulated parts and meet
8.7/15 (17.5) kV
the requirements of CENELEC EN
12/20 (24) kV
50180 and IEC 60137. 30 12.7/22 (24) kV
10 18/30 (36) kV
19/33 (36) kV
330

Up to 36kV - 630A
144
ORDERING INSTRUCTIONS Minimum oil level: Dia.
To order the equipment bushing, - 12 kV: 40 mm 25
- 24 kV: 50 mm
specify the type. - 36 kV: 75 mm

The bushings can be supplied


with an earth jumper (/J). 40
E.g. M400AR-3/J.
For use in potentially explosive M16
Dia. 70
atmospheres (for 12 kV max), Dia. 88
order: 400AR-3/ATEX. Dia. 128

In mm.

Equipment Voltage Current


bushing Um Ir
type (kV) (A)
400AR-3 12 630
K400AR-3 24 630
M400AR-3 36 630 09/2017

14
FIXINGS FOR EQUIPMENT BUSHINGS

400AR-3/J BUSHING BUSHING CLAMPING KIT


To order the bushing clamping
kit, according to DIN 42 538
standards, simply specify KBCD-
400B.
bushing interface Contents: - 1 x fixing flange B
- 6 x stud clamp E
fixing studs
- 1 x sealing gasket.

fixing flange
B DIN 42 538

E DIN 42 538
stud clamp

equipment
FIXING DIMENSIONS
sealing gasket STANDARDS DIN 42 538
German standards.

equipment
connection
M10

Min. 55
Max. 25

6 fixing
Dia. 90
studs
Dia. 140

earth jumper
In mm.

15
400AR-4 INTERFACE C2
EQUIPMENT BUSHING

APPLICATION TECHNICAL
For use in equipment insulated CHARACTERISTICS
with oil fluid, typically for Each bushing is tested for
transformers, switchgear, AC withstand and partial
capacitors... discharge prior to leaving
the factory.

SPECIFICATIONS AND
STANDARDS
The bolted type equipment
bushings 400AR-4 are moulded
epoxy insulated parts and meet 139 6/10 (12) kV
the requirements of CENELEC EN 6.35/11 (12) kV
50180 and IEC 60137. 8.7/15 (17.5) kV
36
12/20 (24) kV
10 12.7/22 (24) kV
329 18/30 (36) kV
19/33 (36) kV
Up to 36kV - 1250A
ORDERING INSTRUCTIONS 138

Minimum oil level:


To order the equipment bushing, - 12 kV: 40 mm
Dia. 32
specify the type. - 24 kV: 50 mm
- 36 kV: 120 mm
The bushings can be supplied with
an earth jumper (/J) or an earth
40
plate (/GS). This earth connection
must be specified when ordering. M16
Dia. 70
E.g. M400AR-4/GS. Dia. 100
Dia. 150

In mm.

Equipment Voltage Current


bushing Um Ir
type (kV) (A)
400AR-4 12 1250
K400AR-4 24 1250
M400AR-4 36 1250
09/2017

16
FIXINGS FOR EQUIPMENT BUSHINGS
400AR-4/GS BUSHING 400AR-4/J BUSHING

bushing interface

fixing studs

fixing flange

NF C 52-053
claw clamp F DIN 42 538
stud clamp

equipment

sealing gasket

equipment
connection

earth plate

earth jumper

BUSHING CLAMPING KIT BUSHING CLAMPING KIT


To order the bushing clamping kit, To order the bushing clamping kit
according to NFC 52-053 with DIN style fixing flange, simply
standards, simply specify KBC- specify KBCDS-400.Contents:
NF-400. -1 x fixing flange DIN style
-6 x stud clamp F DIN 42 538
Contents: - 4 x claw clamp NF400
-1 x sealing gasket.
- 1 x sealing gasket.

FIXING DIMENSIONS
STANDARDS NF C 52-053 FIXING DIMENSIONS
French standards.

M10 or
M12
M12

Min. 55 Min. 60
Max. 25 Max. 30

4 fixing 6 fixing
studs Dia. 105 studs Dia. 105 17
Dia. 171 Dia. 171

In mm.
400AR-5 INTERFACE C2
EQUIPMENT BUSHING

APPLICATION TECHNICAL
For use in equipment insulated CHARACTERISTICS
with oil fluid, typically for Each bushing is tested for
transformers, switchgear, AC withstand and partial
capacitors... discharge prior to leaving
the factory.

SPECIFICATIONS AND
STANDARDS
The bolted type equipment 6/10 (12) kV
bushings 400AR-5 are moulded 6.35/11 (12) kV
epoxy insulated parts and meet
139
8.7/15 (17.5) kV
the requirements of CENELEC EN 12/20 (24) kV
50180 and IEC 60137. 36 12.7/22 (24) kV
18/30 (36) kV
245

Minimum oil level:


- 12 kV: 40 mm 72
- 24 kV: 50 mm
Dia. 32
Up to 36kV - 1250A
- 36 kV: 70 mm

32

M16
Dia. 76

ORDERING INSTRUCTIONS Dia. 150

To order the equipment bushing,


specify the type. In mm.
The bushings can be supplied with
an earth jumper (/J) or an earth
plate (/GS). This earth connection
must be specified when ordering.
E.g. M400AR-5/GS.

Equipment Voltage Current


bushing Um Ir
type (kV) (A)
400AR-5 12 1250
K400AR-5 24 1250
M400AR-5 36 1250

09/2017

18
FIXINGS FOR EQUIPMENT BUSHINGS

400AR-5/GS BUSHING 400AR-5/J BUSHING

bushing interface

fixing studs

fixing flange

NF C 52-053
claw clamp F DIN 42 538
stud clamp
equipment
sealing gasket
equipment
connection

earth plate

earth jumper

BUSHING CLAMPING KIT BUSHING CLAMPING KIT


To order the bushing clamping kit, To order the bushing clamping kit
according to NFC 52-053 with DIN style fixing flange, simply
standards, simply specify KBC- specify KBCDS-400.Contents:
NF-400. - 1 x fixing flange DIN style
- 6 x stud clamp F DIN 42 538
Contents: - 4 x claw clamp NF400
- 1 x sealing gasket.
- 1 x sealing gasket.

FIXING DIMENSIONS
STANDARDS NF C 52-053 FIXING DIMENSIONS
French standards.

M10 or
M12
M12

Min. 55 Min. 60
Max. 25 Max. 30

4 fixing 6 fixing
studs Dia. 105 studs Dia. 105
Dia. 171 Dia. 171 19

In mm.
400AR-6 INTERFACE C1
EQUIPMENT BUSHING

APPLICATION TECHNICAL
For use in equipment insulated CHARACTERISTICS
with oil fluid, typically for Each bushing is tested for
transformers, switchgear, AC withstand and partial
capacitors... discharge prior to leaving
the factory.

SPECIFICATIONS AND
STANDARDS 6/10 (12) kV
The bolted type equipment 6.35/11 (12) kV
bushings 400AR-6 are moulded 8.7/15 (17.5) kV
133
epoxy insulated parts and meet 12/20 (24) kV
the requirements of CENELEC EN 12.7/22 (24) kV
50180 and IEC 60137. 18/30 (36) kV
30
19/33 (36) kV
10

Up to 36kV - 630 A

398

ORDERING INSTRUCTIONS
To order the equipment bushing,
specify the type. 213

The bushings can be supplied


with an earth jumper (/J).
This earth connection must be Minimum oil level:
specified when ordering. - 12 kV: 40 mm Dia.
25
- 24 kV: 50 mm
E.g. M400AR-6/J. - 36 kV: 75 mm

40

M16
Dia. 70
Dia. 74
Dia. 128

In mm.

Equipment Voltage Current


bushing Um Ir
type (kV) (A)
400AR-6 12 630
K400AR-6 24 630
M400AR-6 36 630 09/2017

20
FIXINGS FOR EQUIPMENT BUSHINGS

400AR-6/J BUSHING BUSHING CLAMPING KIT


To order the bushing clamping
kit, according to DIN 42 538
standards, simply specify KBCD-
400B.
bushing interface Contents: - 1 x fixing flange B
- 6 x stud clamp E
- 1 x sealing gasket.
fixing studs

fixing flange
B DIN 42 538

E DIN 42 538
stud clamp

equipment FIXING DIMENSIONS


STANDARDS DIN 42 538
sealing gasket German standards.

M10

Min. 55
Max. 25
equipment
connection
6 fixing
Dia. 80
studs
Dia. 140

In mm.

earth jumper

21
400SFR-B INTERFACE C2
EQUIPMENT BUSHING

APPLICATION TECHNICAL
For use in equipment insulated CHARACTERISTICS
with SF6 gas. Each bushing is tested for
AC withstand and partial
discharge prior to leaving the
factory.

Dia. 70
DESIGN
The equipment bushing is a 6/10 (12) kV
moulded epoxy insulated part with 6.35/11 (12) kV
a connector interface in accordance 8.7/15 (17.5) kV
with CENELEC EN 50181. 12/20 (24) kV
The 400SFR-B bushing has a shank 12.7/22 (24) kV
outside this standard, adapted to 18/30 (36) kV
use in SF6 gas. 218 19/33 (36) kV
Up to 36kV - 1250 A
33
SPECIFICATIONS AND
STANDARDS
The bolted type equipment
bushing 400SFR-B meets the
requirements of CENELEC EN
50180 and IEC 60137. 95

ORDERING INSTRUCTIONS
To order the equipment bushing,
M12
simply specify the type.
Dia. 32
Dia. 70
Dia. 109 In mm.

Equipment Voltage Current


bushing Um Interface Ir
type (kV) (A)
400SFR-B 1250 A 12 C2 1250
K400SFR-B 1250 A 24 C2 1250
M400SFR-B 1250 A 36 C2 1250
09/2017

22
FIXINGS FOR EQUIPMENT BUSHINGS

400SFR-B BUSHING FOR GAS


INSULATED SWITCHGEAR

UNMOUNTED
earth
60° connection
M4

60° 60°

30°

83

M6

Dia. 91.5
Dia. 103.1

equipment
MOUNTED

equipment
connection
earth
bushing
connection
interface 6 fixing M4
screws sealing
M6 O-ring
gasket
In mm.

23
400A-24B INTERFACE C1
IN-AIR BUSHING

APPLICATION TECHNICAL
For use in equipment insulated CHARACTERISTICS
with air, typically for dry type Each bushing is tested for
transformers, motors, switchgear, AC withstand and partial
capacitors... discharge prior to leaving
the factory.

SPECIFICATIONS AND
STANDARDS
The bolted type equipment 6/10 (12) kV
bushings 400A-24B are moulded 6.35/11 (12) kV
epoxy insulated parts and meet 8.7/15 (17.5) kV
the requirements of CENELEC 12/20 (24) kV
EN 50180, IEC 60071 and IEC 12.7/22 (24) kV
30
60137.
20
Up to 24 kV - 630 A
Dia. 80

A
Dia. 110

ORDERING INSTRUCTIONS 434


To order the equipment bushing,
specify the type.
The bushings are supplied with an 250
earth jumper.
To include the ring clamp, add:
• /B, if per British standards
• /D, if per German standards Dia.
• /F, if per French standards. 25
E.g. 400A-24B/D.
For use in potentially explosive
atmospheres (for 12 kV max),
order: -/ATEX. 40

B M16
Dia. 80
In mm.

Equipment Voltage Current Creepage distance


bushing Um Ir A-B
type (kV) (A) (mm)
400A-24B 12 630 520
400A-24B 24 630 520 09/2017

24
FIXINGS FOR EQUIPMENT BUSHINGS
400A-24B IN-AIR BUSHING
bushing interface

fixing studs and


nuts M10

earth jumper

equipment

gasket

equipment
connection

fixing flange
BCA-B or fixing flange
BCA-D BCA-F

Dia.12 Dia.12
Dia. 94.5 Dia. 94.5
4 4
10 10
Dia. 111 Dia. 111

120°

126

120°
BS 2562 stand.: 120
DIN 42 538 stand.: 123 Dia. 150
Dia. 150
Type BCA-B : BS 2562 British standards Type BCA-F : NFC 52-053 French standards
Type BCA-D : DIN 42 538 German standards

FIXING DIMENSIONS FIXING DIMENSIONS


STANDARDS DIN 42 538 STANDARDS NF C 52-053
German standards. French standards.

M10 M10

Min. 55 Min. 55
Max. 20 Max. 20

4 fixing 3 fixing
25
studs studs

Dia. 82
Dia. 123
Dia. 82
Dia. 126
In mm.
670AR-2 INTERFACE D
EQUIPMENT BUSHING

APPLICATION TECHNICAL
For use in equipment insulated CHARACTERISTICS
with oil fluid, typically for Each bushing is tested for
transformers, switchgear, AC withstand and partial
capacitors... discharge prior to leaving
the factory.

SPECIFICATIONS AND
STANDARDS 6/10 (12) kV
The bolted type equipment
bushings 670AR-2 are moulded
6,35/11 (12) kV
epoxy insulated parts and meet
130
8,7/15 (17,5) kV
the requirements of CENELEC EN
12/20 (24) kV
50180 and IEC 60137. 36
12,7/22 (24) kV
10

325
Up to 24 kV - 1250 A

ORDERING INSTRUCTIONS 140


To order the equipment bushing, Dia.
32
Minimum oil level:
specify the type. -12 kV: 40 mm
The bushings can be supplied with -24 kV: 50 mm

an earth jumper (/J) or an earth


plate (/GS). This earth connection 40
must be specified when ordering.
M16
E.g. K670AR-2/GS. Dia. 70
Dia. 100
Dia. 150

In mm.

Equipment Voltage Current


bushing Um Ir
type (kV) (A)
670AR-2 12 1250
K670AR-2 24 1250

09/2017

26
FIXINGS FOR EQUIPMENT BUSHINGS
670AR-2/GS BUSHING 670AR-2/J BUSHING

bushing interface

fixing studs

fixing flange

NF C 52-053
claw clamp F DIN 42 538
stud clamp

equipment

sealing gasket

equipment
connection

earth jumper
earth plate

BUSHING CLAMPING KIT BUSHING CLAMPING KIT


To order the bushing clamping kit, To order the bushing clamping kit
according to NFC 52-053 with DIN style fixing flange, simply
standards, simply specify KBC- specify KBCDS-400.Contents:
NF-400. - 1 x fixing flange
DIN style
Contents: - 4 x claw clamp NF
- 6 x stud clamp
- 1 x sealing gasket.
F DIN 42 538
- 1 x sealing gasket.

FIXING DIMENSIONS FIXING DIMENSIONS


STANDARDS NF C 52-053
French standards.

M10 or M12
M12

Min. 55 Min. 60
Max. 25 Max. 30

4 fixing
studs Dia. 105
6 fixing
studs
Dia. 105 27
Dia. 171 Dia. 171

In mm.
900AR-1/900AR-2/900AR-3/900AR-4 INTERFACE F
EQUIPMENT BUSHING

APPLICATION TECHNICAL
For use in equipment, typically CHARACTERISTICS
for transformers, switchgear, Each bushing is tested for
capacitors... AC withstand and partial
discharge prior to leaving
the factory.

SPECIFICATIONS AND
STANDARDS 6/10 (12) kV
6.35/11 (12) kV
110.5
The bolted type equipment
bushings 900AR-X are moulded 8.7/15 (17.5) kV
epoxy insulated parts and meet 12/20 (24) kV
the requirements of CENELEC EN gasket 35 12.7/22 (24) kV
50180 and IEC 60137. 18/30 (36) kV
19/33 (36) kV
Dia. 110+50
A
20.8/36 (42) kV

ORDERING INSTRUCTIONS B Up to 42 kV - 2500 A


Minimum oil level:
To order the equipment bushing, -12 kV: 40 mm
-24 kV: 50 mm
specify the type. -36 kV: 75 mm
-42 kV: 120 mm
Dia. C
Add a 'K' for use up to 24 kV, add
an 'M' for use up to 36 kV,
add a 'P' for use up to 42 kV.
40
The bushings can be supplied
with an earth jumper (/J) or an M16

earth plate (/GS). This earth Dia. 100 at sharp


Dia. 150
connection must be specified
when ordering.
In mm.
E.g. 900AR-4/GS.

Equipment Voltage Current Dimensions (mm)


Interface
bushing Um Ir
type
type (kV) (A) A B Dia. C
900AR-1 F3 42 1250 364 175 32
900AR-2 F2 42 630 364 175 25
900AR-3 F1 36 2500 364 175 50
900AR-4 F1 36 2500 259 70 50

09/2017

28
FIXINGS FOR EQUIPMENT BUSHINGS
900AR-X/GS BUSHING 900AR-X/J BUSHING

bushing interface

fixing studs

fixing flange

NF C 52-053
claw clamp EN50180-3
400/630 series stud clamp

equipment

sealing gasket

equipment
connection

earth
plate earth
jumper

BUSHING CLAMPING KIT BUSHING CLAMPING KIT


To order the bushing clamping kit, To order the bushing clamping
according to NF C 52-053 kit with DIN style fixing flange,
standards, simply specify KBC- simply specify KBCDS-400.
NF-400. Contents: - 1 x fixing flange
DIN style
Contents: - 4 x claw clamp NF400
- 6 x stud clamp
- 1 x sealing gasket.
EN50180-3
- 1 x sealing gasket.
FIXING DIMENSIONS
STANDARDS NF C 52-053 FIXING DIMENSIONS
French standards.

M12
M10 or
M12

Min. 60
Min. 55 Max. 30
Max. 25

6 fixing
4 fixing Dia. 110+50 studs
Dia. 110+50
Dia. 171
29
studs Dia. 171

In mm.
NOTES
Nexans Network Solutions N.V. - Div. Euromold
Zuid III, Industrielaan 12, B-9320 Erembodegem
Tel.: +32(0)53 85 02 11 • sales.euromold@nexans.com • www.euromold.be

Catalogue also available on Website and Mobile Apps

Find out more about Nexans Power Accessories.


09/2017

You might also like