FLEXURAL ANALYSIS OF SINGLY REINFORCED RECTANGULAR BEAM

based from ACI 318-14

Programmed by: ENGR. RYAN M. LAYUG | ryanmlayug@gmail.com

A. INPUT DATA

Beam Section:

250mm x 400mm, 5 - 20mm ϕ

Beam Dimension: Strength Parameters:

b ≔ 250 mm fc' ≔ 17.7 MPa


h ≔ 400 mm fy ≔ 230 MPa

Reinforcement Paremeters: Required Strength:

db ≔ 20 mm Mu ≔ 80 kN-m
ds ≔ 10 mm
concrete_cover ≔ 50 mm
layer_clear_spacing ≔ 50 mm

⎡ Nlayer1 ⎤ ⎡ 3 ⎤
⎢ ⎥≔⎢ ⎥
⎣ Nlayer2 ⎦ ⎣ 2 ⎦

B. ANALYSIS

C. RESULT D. FIGURE

Steel_Ratio_Percentage = 2.08 % 450

Ductility_Percentage = 38.82 %
400
Ductility = “Ductile”

350
ϕ ⋅ Mn = 82.58 kN-m
Mu = 80 kN-m 300

Remark = “Safe”
250

rebar_clear_spacing = 35 mm
200
Rebar_clear_spacing = “OK”
150

100

50

0
0 50 100 150 200 250 300

Project Name: Owner: