You are on page 1of 6

Footing Name:

DESIGN OF ISOLATED RECTANGULAR FOOTING


based from UBC-97 and ACI 318-14

Programmed by: ENGR. RYAN M. LAYUG | ryanmlayug@gmail.com

A. INPUT DATA

Footing Name:

IF

Loadings:

NOTE: Axial load input for DEAD and LIVE LOADS must be positive (compression).

Unfactored Vertical Loads Unfactored Moment about X Unfactored Moment about Y

PD ≔ 400 kN MDX ≔ 1 kN-m MDY ≔ 1 kN-m

PL ≔ 100 kN MLX ≔ 0 kN-m MLY ≔ 0 kN-m

PE ≔ 150 kN MEX ≔ 50 kN-m MEY ≔ 50 kN-m

Factored Horizontal Load

Vu ≔ 150 kN

Strength Parameters:

fc' ≔ 20.6 MPa

fy ≔ 276 MPa

Footing Paremeter:

db_footing ≔ 25 mm

qall ≔ 120 kPa

footing_thickness ≔ 500 mm

footing_width ≔ 3 m

footing_depth ≔ 2 m

soil_backfill_unit_weight ≔ 18 kN/m^3

reinforced_concrete_unit_weight ≔ 25 kN/m^3

α ≔ 20 Interior Column = 40
Edge Column= 30
Corner Column = 20

Column Paremeter:

column_steel_percent ≔ 2%

db_column ≔ 25 mm

Cx ≔ 600 mm

Cy ≔ 400 mm

Project Name: Owner:


Location: Civil Engineer / Designer: Page 1 of 6
Figure:

B. ANALYSIS

Determine the dimension of the footing

Lmin = 2.63 m NOTE: This dimension is based only on the axial loads; without bending moments.

Assume footing length

L≔6 m

Check the footing dimension


⎡ D ⎤
⎢ D+L ⎥
⎡1⎤ ⎢ ⎥
ASD_Load_Combination ≔ 4 ⎢2⎥ ⎢ E
⎢ ⎥=⎢ D + ―― ⎥

⎢3⎥ ⎢ 1.4
⎣4⎦ ⎛ E ⎞⎥
⎢ D + 0.75 ⎜L + ―― ⎟⎥
⎢⎣ ⎝ 1.4 ⎠ ⎥⎦

Pa = 987.36 kN
MaX = 27.79 kN-m
MaY = 27.79 kN-m

qnet = 80.5 kPa ⎡ 56 57 58 59 ⎤


⎢ 54 55 56 57 ⎥
qmax = 59.5 kPa Soil_Pressure = ⎢ ⎥ kPa
⎢ 52 53 54 55 ⎥
qmin = 50.2 kPa ⎣ 50 51 52 53 ⎦

Footing_Dimension = “Safe”

Project Name: Owner:


Location: Civil Engineer / Designer: Page 2 of 6
4

3.7 56.85 57.8 58.75

3.4 55.9

3.1 54.95

2.8
54
2.5

2.2

1.9

1.6

1.3
51.15 52.1 53.05
1
1 1.3 1.6 1.9 2.2 2.5 2.8 3.1 3.4 3.7 4

51.15 52.1 53.05 54 54.95 55.9 56.85 57.8 58.75

Determine the factored loads


⎡1⎤ ⎡ 1.4 D ⎤
⎢2⎥ ⎢ 1.2 D + 1.6 L ⎥
USD_Load_Combination ≔ 3 ⎢ ⎥=⎢ ⎥
⎢ 3 ⎥ ⎢ 1.2 D + 0.5 L + 1.0 E ⎥
⎣4⎦ ⎣ 0.9 D + 1.0 E ⎦

PU = 680 kN
MUX = 51.2 kN-m
MUY = 51.2 kN-m

Check the assumed thickness

for punching shear

VP_requried_strength = 650.62 kN
VP_design_strength = 1560.89 kN

Punching_Shear = “Safe”

for one way shear

VW_required_strength_x = 274.21 kN VW_required_strength_y = 228.51 kN


VW_design_strength_x = 672.72 kN VW_design_strength_y = 1345.45 kN

One_Way_Shear = “Safe”

Check the bearing capacity

for footing

PF_required_strength = 680 kN
PF_design_strength = 5463.12 kN

Footing_Bearing = “Adequate column main reinfrocement”

Project Name: Owner:


Location: Civil Engineer / Designer: Page 3 of 6
for column

PC_required_strength = 680 kN
PC_design_strength = 2731.56 kN

Column_Bearing = “Adequate column main reinfrocement”

Minimum_Area_of_Dowels = 1200 mm^2

Determine the required reinforcement

Required nX = 11.68 nx_bending = 11.68


nx_min = 12.01
nx_temp_sh = 4.74

nY = 9.47 ny_bending = 5.9 ny_min = 24.03 ny_temp_sh = 9.47

nY_central_band = 6.32

nY_outer_band = 3.16

Use NX ≔ 12

NY_central_band ≔ 11

NY_outer_band ≔ 8

Check the development length

Length_Development_x = “Hook not required”

Length_Development_y = “Hook not required”

Length_Development_column_rebar_compression = “Safe”

Length_Development_column_rebar_tension = “Safe”

Check the thickness of the footing and spacing of rebars

Thickness = “Safe”

Spacing_longitudinal = “Safe”
spacing_longitudinal = 250 mm

Spacing_center_band = “Safe”
spacing_central_band = 300 mm

Project Name: Owner:


Location: Civil Engineer / Designer: Page 4 of 6
Spacing_outer_band = “Safe”
spacing_outer_band = 350 mm

Check the transfer of horizontal force at base of column

Shear_Transfer = “Safe - the column is adquate for shear transfer”

C. DESIGN

Width = 3 m

Length = 6 m

thickness = 500 mm

Bar_Size = 25 mm

Number_of_Rebar_longitudinal = 12

Number_of_Rebar_center_band = 11

Number_of_Rebar_outer_band = 8

D. DESIGN RATIO

Reinforcement_longitudinal = 1.03

Reinforcement_traverse_center_band = 1.74

Reinforcement_traverse_outer_band = 2.53

Soil_Pressure = 1.35

Punching_Shear = 2.4 NOTE: The design ratio for Punching Shear should be at least
1.2 to take account the eccentric shear.
OneWay_Shear = 2.45

Column_Bearing = 4.02

Footing_Bearing = 8.03

Project Name: Owner:


Location: Civil Engineer / Designer: Page 5 of 6
E. REINFORCEMENT DETAIL

2.7

2.4

2.1

1.8

1.5

1.2

0.9

0.6

0.3

0
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6

1000

800

600

400

200

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000

1000

800

600

400

200

0
0 500 1000 1500 2000 2500 3000

Project Name: Owner:


Location: Civil Engineer / Designer: Page 6 of 6

You might also like