You are on page 1of 4

LOAD CALCULATIONS

Job No. : ESBS-PB1638 Rev. No. : R0


Project : MAIN BOPP PLANT BUILDING Date : 01/06/2015
Clint : COSMO FILMS LTD. Designed by : NAVEEN
BUILDING SOLUTIONS Description : LOAD ON FRAME AT GRID 5 Checked by : NVH
Building Type = EMS1
Length (C/C) = 180.00 m
Width (C/C) = 69.00 M
Width module (I/I) = 1@26+1@28+1@15
Bay spacing /load width = 6.00 m
Clear eave hight = 6.50M
Height from Base plate to mid of = 7.10 m 0.3M+6.5M+.6/2M
Rafter.
Roof slope (θ) = 5.71 ˚
DEAD LOAD (DL)
Wt. of sheet & purline = 15.00 Kg/m² sheeting = 5 kg/sqm, purlins = 5.0 kg/sqm and misc.steel(sagrod, flange braces,
Dead Load (DL) = 0.90 KN/m bracings, hardware etc.) = 5 kg/sqm

Collateral Load on Rafter


Collateral Load on Rafter = 50.00 Kg/m² Other Collateral Load = 20.00 Kg/m²
= 3.00 KN/m = 1.20 KN/m

ROOF LIVE LOAD (LL)


Live load/unit area, roof = 75.00 Kg/m²
Live Load (LL) = 4.50 KN/m

EARTH QUAKE LOAD ON RAFTER APPLIED AS UDL (EQ)


Earth Quake load/unit area = 65.00 Kg/m²
Earth Quake Load (EQL) = 3.90 KN/m
NOTE: - Static analysis is adopted for seismic analysis.
WIND LOAD (WL)
Basic wind speed (Vb) = 44 m/s
Design wind speed (Vz) = Vbxk1xk2xk3
where,
k1 = probability factor (risk coefficient)
= 1 Terrain Category Class
k2 = terrain, height and structure size factor 2 C
= 0.93
k3 = topography factor
= 1
Vz = 40.92 m/s

Design wind pressure (pz) = 0.6xVz²


pz = 1.00 KN/m²

PRESURE COEFFICIENTS:~
Encloser condition of the building = Partially Enclosed
Internal pressure coeff.(Cpi) = 0.50

h/w = 0.10
= h/w<=1/2
l/w = 2.61
= 3/2<=l/w<4
External pressure coeff.(Cpe) : Table 4 Table 5
Wind Angle Coeff. For Wall Coeff. For Roof
(ө)
Left Right Left Right
0 degree 0.70 -0.25 -0.94 -0.40
90 degree -0.50 -0.50 -0.80 -0.80
WIND LOAD DIAGRAMS:~
Total Pressure Coefficient (Cp) = Cpe-Cpi
Total Pressure in UDL = Cp X Pz x Bay Spacing
Applied on Column and
Rafters.
WIND LOAD APPLIED ON FRAMES.
Loads applied on Frame due to Suction, Negatic internal Pressure Loads applied on Frame due to Pressure, Positive internal Pressure
Wind Across the Ridge (With -Ve Cpi) Wind Across the Ridge (With +Ve Cpi) KN/m
"-0.91-(-0.5)" -0.44 -2.67 KN/m 0.10 0.60 KN/m "-0.91-(0.5 -1.44 -8.70 KN/m -0.90 -5.43
"-0.6-(-0.5)" "-0.6-(0.5)"

KN/m KN/m KN/m KN/m


7.23 1.51 1.21 -4.52
1.20 0.25 0.20 -0.75
0.70-(-0.5) "-0.25-(-0.5)" 0.70-(0.5) "-0.25-(0.5)"

Wind Left to Right and Wind Right to Left Wind Left to Right and Wind Right to Left
Both Cases are applied for analysis of frame Both Cases are applied for analysis of frame

Loads applied on Frame due to Pressure, Positive internal Pressure


Wind Parallel to Ridge(With +Ve Cpi)
"-0.89-(0.5)" -1.30 -7.84 KN/m -1.30 -7.84 KN/m
"-0.89-(0.5)"

KN/m KN/m
-6.03 -6.03
-1.00 -1.00
-0.7-(0.5) Note:
"-0.7-(0.5) 1) Values within the circles are the UDL
2) -Ve value means, load applied
away from structure.
LOAD CALCULATIONS
Job No. : ESBS-PB1638 Rev. No. : R-00
Project : MAIN BOPP PLANT BUILDING Date : 8-Feb-16
Client : COSMO FILMS LTD. Designed by : LOKENDER
Description : LOAD ON FRAME AT GRID 5 Checked by : AUK
Building Type = ECS
Length = 180 m
Width = 43 m
Width Module = - m
Bay Spacing = 6.00 m
Clear Eave Height = 17.0 m

Roof Slope (θ) = 5.71 ˚


DEAD LOAD ON ROOF (DL)
Wt. of sheet&purline = 15.00 Kg/m²
Dead Load (DL) = 0.90 KN/m

COLLATERAL LOAD ON ROOF


Wt. of sheet&purline = 50.00 Kg/m²
Collateral Load (COL) = 3.00 KN/m Other Collateral Load = 20.00 Kg/m²
= 1.20 KN/m
LIVE LOAD ON ROOF (LL)
Live load/unit area, roof = 75.00 Kg/m²
Live Load (LL) = 4.50 KN/m

EARTHQUACK LOAD (EQ)


Seismic zone factor = 0.16 ZONE- III
Importance factor = 1.75
Response reduction factor = 5

WIND LOAD (WL)


Basic wind speed (Vb) = 44 m/s
Design wind speed (Vz) = Vbxk1xk2xk3
= 44.00 m/s
where,
k1 = probability factor (risk coefficient)
= 1
k2 = terrain, height and structure size factor TERRAIN CATEGORY 2
= 1 CLASS C
k3 = topography factor
= 1

Design wind pressure (pz) = 0.6xVz²


= 1.16 KN/m²

PRESURE COEFFICIENTS:~ A & B


Encloser condition of the building = Partially Enclosed
Internal pressure coeff.(Cpi) = 0.50

h/w = 0.40 C
= h/w<=1/2
l/w = 4.19
= >l/w>4 A&B
External pressure coeff.(Cpe) :
Wind Coeff. For Wall Coeff. For Roof A B
Angle Left Right H L
0 degree 0.70 -0.25 -1.00 -0.50
90 degree -0.50 -0.50 -1.00 -1.00
D
WIND LOAD DIAGRAMS:~

Wind Across the Ridge 0 degrees (With -Ve Cpi) WL1

FROM LEFT FROM RIGHT

-10.45 KN/m -6.97 KN/m -6.97 KN/m -10.45 KN/m


-1.50 -1.00 -1.00 -1.50

1.39 -5.23 -5.23 1.39


KN/m -0.5 KN/m KN/m -0.5 KN/m
0.20 -0.75 -0.75 0.20

Wind Across the Ridge 0 degrees (With +Ve Cpi) WL2


FROM LEFT FROM RIGHT

-3.48 KN/m 0.00 KN/m 0.00 KN/m -3.48 KN/m


-0.50 0.00 0.00 -0.50

8.36 1.74 1.74 8.36


KN/m 0.5 KN/m KN/m 0.5 KN/m
1.20 0.25 0.25 1.20

Wind parallel to Ridge 90 degrees (With -Ve Cpi) WLN1

FROM LEFT FROM RIGHT

-10.45 KN/m -10.45 KN/m -10.45 KN/m -10.45KN/m


-1.50 -1.50 -1.50 -1.50

-6.97 -6.97 -6.97 -6.97


KN/m KN/m KN/m -0.5 KN/m
-1.00 -0.5 -1.00 -1.00 -1.00

Wind parallel to Ridge 90 degrees (With +Ve Cpi) WNL2

FROM LEFT FROM RIGHT

-3.48 KN/m -3.48 KN/m -3.48 KN/m -3.48 KN/m


-0.50 -0.50 -0.50 -0.50

0.00 0.00 0.00 0.00


KN/m 0.5 KN/m KN/m 0.5 KN/m
0.00 0.00 0.00 0.00

You might also like