PRESURE COEFFICIENTS:~
Encloser condition of the building = Partially Enclosed
Internal pressure coeff.(Cpi) = 0.50
h/w = 0.10
= h/w<=1/2
l/w = 2.61
= 3/2<=l/w<4
External pressure coeff.(Cpe) : Table 4 Table 5
Wind Angle Coeff. For Wall Coeff. For Roof
(ө)
Left Right Left Right
0 degree 0.70 -0.25 -0.94 -0.40
90 degree -0.50 -0.50 -0.80 -0.80
WIND LOAD DIAGRAMS:~
Total Pressure Coefficient (Cp) = Cpe-Cpi
Total Pressure in UDL = Cp X Pz x Bay Spacing
Applied on Column and
Rafters.
WIND LOAD APPLIED ON FRAMES.
Loads applied on Frame due to Suction, Negatic internal Pressure Loads applied on Frame due to Pressure, Positive internal Pressure
Wind Across the Ridge (With -Ve Cpi) Wind Across the Ridge (With +Ve Cpi) KN/m
"-0.91-(-0.5)" -0.44 -2.67 KN/m 0.10 0.60 KN/m "-0.91-(0.5 -1.44 -8.70 KN/m -0.90 -5.43
"-0.6-(-0.5)" "-0.6-(0.5)"
Wind Left to Right and Wind Right to Left Wind Left to Right and Wind Right to Left
Both Cases are applied for analysis of frame Both Cases are applied for analysis of frame
KN/m KN/m
-6.03 -6.03
-1.00 -1.00
-0.7-(0.5) Note:
"-0.7-(0.5) 1) Values within the circles are the UDL
2) -Ve value means, load applied
away from structure.
LOAD CALCULATIONS
Job No. : ESBS-PB1638 Rev. No. : R-00
Project : MAIN BOPP PLANT BUILDING Date : 8-Feb-16
Client : COSMO FILMS LTD. Designed by : LOKENDER
Description : LOAD ON FRAME AT GRID 5 Checked by : AUK
Building Type = ECS
Length = 180 m
Width = 43 m
Width Module = - m
Bay Spacing = 6.00 m
Clear Eave Height = 17.0 m
h/w = 0.40 C
= h/w<=1/2
l/w = 4.19
= >l/w>4 A&B
External pressure coeff.(Cpe) :
Wind Coeff. For Wall Coeff. For Roof A B
Angle Left Right H L
0 degree 0.70 -0.25 -1.00 -0.50
90 degree -0.50 -0.50 -1.00 -1.00
D
WIND LOAD DIAGRAMS:~