Professional Documents
Culture Documents
Europe
MSC.Software GmbH
Am Moosfeld 13
81829 Munich
GERMANY
Telephone: (49) (89) 43 19 87 0
Fax: (49) (89) 43 61 71 6
Asia Pacific
MSC.Software Japan Ltd.
Shinjuku First West 8F
23-7 Nishi Shinjuku
1-Chome, Shinjuku-Ku
Tokyo 160-0023, JAPAN
Telephone: (81) (3)-6911-1200
Fax: (81) (3)-6911-1201
Worldwide Web
www.mscsoftware.com
User Documentation: Copyright 2010 MSC.Software Corporation. Printed in U.S.A. All Rights Reserved.
This document, and the software described in it, are furnished under license and may be used or copied only in
accordance with the terms of such license. Any reproduction or distribution of this document, in whole or in part,
without the prior written authorization of MSC.Software Corporation is strictly prohibited.
MSC.Software Corporation reserves the right to make changes in specifications and other information contained
in this document without prior notice. The concepts, methods, and examples presented in this document are for
illustrative and educational purposes only and are not intended to be exhaustive or to apply to any particular
engineering problem or design. THIS DOCUMENT IS PROVIDED ON AN “AS-IS” BASIS AND ALL EXPRESS
AND IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE DISCLAIMED,
EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
MSC.Software logo, MSC, MSC., MD, Adams, Dytran, Marc, SimDesigner, SimEnterprise, SimManager and
SimXpert are trademarks or registered trademarks of MSC.Software Corporation or its subsidiaries in the United
States and/or other countries.
NASTRAN is a registered trademark of NASA. FLEXlm is a registered trademark of Macrovision Corporation.
CATIA is a registered trademark of Dassault Systemes S.A. All other trademarks are the property of their
respective owners.
Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in FAR 12.212
(Commercial Computer Software) and DFARS 227.7202 (Commercial Computer Software and Commercial
Computer Software Documentation), as applicable.
SD:V2010.2:Z:CV5-WB:Z:DC-REL-PDF
Contents
Release Guide
1 Release Notes
Requirements 6
Enhancements 7
Structures Workbench 7
Limitations 13
Structures Workbench: 13
Motion Workbench: 13
Nonlinear Workbench: 14
Analysis Manager / Expert Gateway: 14
2 Features Supported
Overview 18
Contact 41
Material 41
1 Release Notes
Requirements
Enhancements
Frequently Asked Questions
Limitations
Product Training and Support
6 Release Guide
Requirements
Requirements
MSC SimDesigner 2010 Workbench Edition requires CATIA V5 R19
Chapter 1: Release Notes 7
Enhancements
Enhancements
The following enhancements are new for MSC SimDesigner 2010.2 Workbench Edition for CATIA V5:
Structures Workbench
• Scriptable (macro) access to ID management utilities
8 Release Guide
Frequently Asked Questions
Question: Why are the transmitted DOF for RBE3 properties not getting exported properly?
Answer: As of SimDesigner 2005 for CATIA V5R14, the RBE3 property, or ‘smooth property’, was
enhanced to properly include transmitted degrees of freedom on the RBE3 card. For databases created
by earlier versions, you must validate the RBE3 property by double-clicking on it, re-selecting the DOF
and clicking OK.
Question: Why are stress values for Shell elements different between SimDesigner for CATIA V5
and CATIA GPS?
Answer: The values can be different because SimDesigner for CATIA V5 uses the Global axis system
while CATIA GPS uses a Local axis system.
Question: After I set up the loads and boundary conditions and clicked on the "Compute" button,
CATIA came back with a "Singularity detected (relative pivot too small)". What went wrong?
Chapter 1: Release Notes 9
Frequently Asked Questions
Answer: Selecting “All” on “Compute” will run all the available cases in the specification tree. And it is
likely that you have a case with no Restraints defined or incomplete boundary conditions. Delete that case
and then rerun by selecting “Analysis Case Solution Selection,” and click on the SimDesigner Case
Solution you wanted to run.
Question: In SimDesigner Thermal workbench, and for shell element parts, why is the part not
being meshed and assigned with material properties?
Answer: For shell element parts, part bodies must be children of the main part in order to mesh and assign
material properties. If this is not the case, use the Change Body command in your part file to move it.
Question: Why am I not able to compute after I export a solver input file?
Answer: The case gets updated after export. To recompute, use “Force Compute”.
Question: Why do I see different Von Mises values from the Image toolbar icon versus the Camera
icon?
Answer: The Image icon shows raw data from the external solvers - whereas the Camera icon data is
derived from a calculation done in SimDesigner.
Question: How do I modify the Scratch directory setting specified during installation?
Answer: By using the SimDesigner Storage Manager facility.
Question: How can I change the default External Storage Directory setting?
Answer: By changing the CATTemp setting in the SimDesigner environment file (<install_dir>\v5ienv\).
It can also be changed for each SimDesigner session by using the Storage Manager facility from within
SimDesigner.
Question: Why doesn’t SimDesigner for CATIA V5 recognize the CATSettings' modifications I
did?
Answer: SimDesigner CATSettings are based on the default CATIA settings. To change the settings
specific to SimDesigner, modify the SimDesigner environment file (<install_dir>\v5ienv\).
Question: When I run an MD Nastran analysis with the Gateway Analysis Manager (GAM), it fails,
why?
10 Release Guide
Frequently Asked Questions
Answer: A common reason is the licensing - during the installation process, the auto-configuration for
GAM will pick up SimDesigner-specific versions of MD Nastran and Marc. Make sure the correct
version number is specified in the SimDesigner Solution Parameters dialog.
Question: When the Gateway Analysis Manager services are not running, after selecting Setup
Batch, why does it take a while for the setup batch to respond with a message?
Answer: In such a case, services need to be started manually. Please refer to the SimDesigner Installation
Guide for information concerning the configuration of the Gateway Analysis Manager.
Question: What causes batch job submission to fail with a job ID of zero?
Answer: When defining a new job, ensure that the name of the input file and its location does not contain
any spaces.
Question: How can I include multiple load cases in one bulk data file for MD Nastran?
Answer: Use the Restraint Set/LoadSet and Combined LoadSet icons available in the SimDesigner
toolbar.
Question: Does SimDesigner use the Computations and Results link seen in the Analysis Manager
spec tree?
Answer: The Computations and Results link (CATAnalysisComputations and CATAnalysisResults file)
is not relevant for SimDesigner products.
Question: Where can I find information about SimDesigner for CATIA V5 online documentation?
Answer: The SimDesigner for CATIA V5 online documentation (PDF and HTML) is located in:
<install_dir>/Documentation
Question: When I look through the SimDesigner Structures Nonlinear Workbench Solution
Parameters, and click OK without changing any settings, the solution case gets inactivated.
Answer: Click Cancel if you plan on not changing any parameters.
Question: When using SimDesigner Thermal workbench and SimDesigner Structures Nonlinear
workbench, why are my images unclear?
Answer: For proper display, the mesh needs to be hidden using the contextual hide/show command.
Question: Why can't I find the SD Temp Dependency option when I right-click on thermal
material?
Answer: You may not be in the SimDesigner Thermal workbench.
Question: Why is the scratch directory and results directory greyed out in GAM?
Answer: The scratch dir in “setup batch” is not used currently and the results directory is for information
only.
Question: Whenever I click on the “Expert Gateway” icon, sometimes I get a message: “Unable to
initialize and start GAM. Check QueMgr and RmtMgr services. Check GAM installation.” Why?
Answer: There are two possibilities:
1. This error message usually appears when the GAM remote manager does not respond within a
minute. In such a case, contact your system administrator to ensure speedier network access.
2. If it takes a while to respond back with a similar message, it is possible that the MSCQueMgr
services may not have been started.
Question: After I submitted my job in batch, when I click on “Check Job”, why do I see the job in
queue for a long time?
Answer: Check if the MSCRmtMgr service is running. If not, it is normal to see this message. Now, if
you close the setup batch window and reopen it to check the job status, you may see a message: “Unable
to reach host. Check Host and configuration service”. In this case, restart the MSCRmtMgr service. See
the GAM configuration section in the Installation Guide for details.
Question: After I submit a job, I see a “Job Failed” message when I check the status. How do I fix
this?
Answer: A log file should be available for viewing. In the GAM Setup Batch dialog, click on the Browse
button and select the stderr file for your job and then click on the View Log File button to view the file.
Based on the error messages, consult the relevant solver documentation for resolution. Usually, it is a
licensing issue - either there is no valid license or the licensing declaration is not done properly.
12 Release Guide
Frequently Asked Questions
Question: Sometimes, when I import large MD Nastran bulk data files, I get a “command
interrupted” and a “full memory address space condition” message and nothing is imported. How
do I import such files?
Answer: As the current buffer size is not enough to read large files, the NIFIMP_BUFFER_SIZE variable
should be increased to a higher value. This variable can be defined in the SimDesigner environment file
or as an env variable in the windows control panel.
Chapter 1: Release Notes 13
Limitations
Limitations
Structures Workbench:
• In this release, when you export a case to a solver deck, any result attached to the solution set of
that case will be detached. If you just want to see the deck, click on the storage manager next to
the compute command and select the deck for viewing.
• (1-19897181) SimDesigner session may hang during the import of an XDB file that contains
6000 or more bar/beam elements that share the same pair of nodes.
• When exporting MD Nastran bulk data file via Gateway for MD Nastran, Beam properties,
dynamic load combinations, and restraints set combinations (i.e. PBEAML/PBEAM, DLOAD,
and SPCADD) are always written in single precision.
• (1-45050025) In a SimDesigner Dynamic case, the displacement plot in the xy-plotter would
only show the real component. The imaginary component and the overall magnitudes would be
available in future releases.
• (1-48641401) "Compute All" command fails to run a complete coupled thermal analysis after
modification is made to a part.
• The workaround is:
After modification is made to the part, first update the mesh independently. Then you can run
"Compute All."
• (1-20173031) RECL Value entered in Tools/Options does not go into effect immediately for
simulations computed in SimDesigner. But does immediately work for exported Nastran decks.
• Suggested workaround is to export a deck first, and then new RECL value will be in effect for
internally computed simulations.
• (1-57704631) Rigid body does not move during post-processing for nonlinear simulations.
• (1-72314861) When the SimDesigner scratch directory in tools/options is defined as the root
directory (C:\), then results for nonlinear solutions do not get attached correctly.
• Suggested workaround is to not define C:\ as the scratch directory.
Motion Workbench:
• Flex body animation limitations are as follows:
• When you animate multiple flexible parts, CATIA will superimpose the color maps from the
CATAnalysis documents. You can select each color map individually and drag it to another
location.
• To ensure a constant stress range for each color in the color map during an animation, you can
impose maximum and minimum stress values on the color map in the CATAnalysis
document.
• (1-49262211) Animation along with simulation of a flexible body does not show any change in
stress contours.
14 Release Guide
Limitations
Note: The location of the transient XDB file can be found by opening the Storage
Manager command in the SimDesigner Structure Workbench. The transient XDB
file will have a long filename in the format of:
<timestamp>_<resultname>_<timestamp>.xdb
Example:
2007_01_22_11_17_19_Results_1_2007022t111854.xdb
• (1-45190201) When preparing FEA model for modal analysis used for flexible bodies, the
virtual part independent nodes of RBE spiders are not being placed at the handler point (joint
location). Instead independent node is being placed in another location (ex. center of a cylinder).
• Suggested workaround is to edit virtual part and manually redefine the handler point. This will
then result in the correct RBE definition.
• (1-250536154) When changing a part or assembly property such as material, the SimDesigner
Motion mechanism does not detect such a change automatically. To force an update, use the
'Update' button on the SimDesigner Motion toolbar.
Nonlinear Workbench:
• In a SimDesigner Nonlinear solution case, when more than two contact bodies are initially in
contact along a common edge, the Marc solution may fail.
2 Features Supported
Overview
SimDesigner Structures Workbench
SimDesigner Structures Nonlinear Workbench
18 Release Guide
Overview
Overview
This appendix lists the features supported in SimDesigner Structures Workbench, SimDesigner
Structures Nonlinear Workbench and the corresponding Enterprise Gateway Products.
This list is an extension of the list found in the “Before you begin” section of the CATIA V5 GPS
documentation.
For SimDesigner Enterprise products, note the following:
P - GPS is required
A - GAS is required
E - EST is required
Some of the functionalities in these commands are available only if you have previously
installed the EST product - for more details, see the documented task itself.
Refer to the CATIA V5 analysis documentation for more information about GPS, GAS and EST.
GWx functionality shown here is applicable within the context of GPS and SimDesigner only.
Chapter 2: Features Supported 19
SimDesigner Structures Workbench
Analysis Cases
Commands CATIA V5 SimDesigner
Static Case
Static
Constrained
Case
SD Static P P P P
Case
Frequency
Case
SD P P P P
Frequency
Case
Buckling
Case
SD P P P
Buckling
Case
SD Load P P
Stiffened
Frequency
Case
Combined
Case
Pre-
processing
Case
20 Release Guide
SimDesigner Structures Workbench
Solution
Case
Envelop P P
Case
Harmonic
Dynamic
Response
Transient
Dynamic
Response
Modulation
Commands CATIA V5 SimDesigner
White
Noise
Modulation
Import
Frequency
Modulation
Import
Time
Modulation
Chapter 2: Features Supported 21
SimDesigner Structures Workbench
Model Manager
Commands CATIA V5 SimDesigner
3D P P P P
MeshPart
2D P P P P
MeshPart
1D P P P P
MeshPart
Local Mesh P P P P
Sizes
Local Mesh P P P P
Sags
Element P P P P
Type
3D Property P P P P
2D Property P P P P
1D Property P P P P
Imported P P P P
Beam
Property
22 Release Guide
SimDesigner Structures Workbench
Mapping P P P P
Property
Check the P P P P
Model
User P P P P
Material
Mesh Specifications
Commands CATIA V5 SimDesigner
Adaptivity
Boxes
Chapter 2: Features Supported 23
SimDesigner Structures Workbench
Groups
Commands CATIA V5 SimDesigner
Line Group
by
Boundary
Surface
Group by
Boundary
Chapter 2: Features Supported 25
SimDesigner Structures Workbench
Analysis Connections
Commands CATIA V5 SimDesigner
General P, A P, A P, A
Connection
s
Point P, A P, A P, A
Analysis
Connection
s
Point P, A P, A P, A
Analysis
Connection
s within one
part
Line P, A P, A P, A
Analysis
Connection
s
Line P, A P, A P, A
Analysis
Connection
s within one
part
Surface P, A P, A P, A
Analysis
Connection
s
Surface P, A P, A P, A
Analysis
Connection
s within one
part
26 Release Guide
SimDesigner Structures Workbench
Point to P, A P, A P, A
Point
Analysis
Connection
s
Point P, A P, A P, A
Analysis
Interface
Chapter 2: Features Supported 27
SimDesigner Structures Workbench
Connection Properties
Commands CATIA V5 SimDesigner
Fastened P, A P, A P, A P, A
Connection
Property
Fastened P, A P, A P, A
Spring
Connection
Property
Slider P, A P, A P, A P, A
Connection
Property
Contact
Connection
Property
Pressure
Fitting
Connection
Property
Bolt
Tightening
Connection
Property
Virtual
Rigid Bolt
Tightening
Connection
Property
Virtual
Spring Bolt
Tightening
Connection
Property
28 Release Guide
SimDesigner Structures Workbench
Rigid P, A P, A P, A P, A
Connection
Property
Smooth P, A P, A P, A P, A
Connection
Property
User- P, A P, A P, A P, A
Defined
Distant
Connection
Properties
Spot P, A P, A P, A P, A
Welding
Connection
Properties
Seam P, A P, A P, A P, A
Welding
Connection
Properties
Surface P, A P, A P, A
Welding
Connection
Properties
Nodes to P, A P, A P, A
Nodes
Analysis
Connection
s
Node P, A P, A P, A
Analysis
Interface
Chapter 2: Features Supported 29
SimDesigner Structures Workbench
Analysis Assembly
Commands CATIA V5 SimDesigner
Analysis P,A
Assembly
2D Viewer
Virtual Parts
Commands CATIA V5 SimDesigner
Rigid P P P P
Virtual
Parts
Smooth P P P P
Virtual
Parts
Contact
Virtual
Parts
Rigid P P P P
Spring
Virtual
Parts
Spring P P P P
Smooth
Virtual
Parts
Periodicity
Conditions
30 Release Guide
SimDesigner Structures Workbench
Mass Equipment
Commands CATIA V5 SimDesigner
Distributed P P P P
Mass
Line Mass P P P P
Densities
Surface P P P P
Mass
Densities
Restraints
Commands CATIA V5 SimDesigner
Clamps P P P P
Surface P P P P
Sliders
Ball Joins P P P P
Sliders P P P P
Pivots P P P P
Sliding P P P P
Pivots
User- P P P P
defined
Restraints
Iso-static P P P P
Restraints
32 Release Guide
SimDesigner Structures Workbench
Loads
Commands CATIA V5 SimDesigner
Pressure P P P P
Distributed P P P P
Force
Moment P P P P
Line Force P P P P
Density
Surface P P P P
Force
Density
Volume P P P P
Force
Density
Acceleratio P P P P
n
Chapter 2: Features Supported 33
SimDesigner Structures Workbench
Rotation P P P P
Force
Enforced P P P P
Displaceme
nt
SD P P
Restraint
Set
SD Load P P P
Set
SD P P
Combined
Load Set
SD P P
Ambient
Temper-
ature
34 Release Guide
SimDesigner Structures Workbench
SD P P
Reference
Temperatur
e Field
Analysis P,A
Assembly
2D Viewer
Sensors
Commands CATIA V5 SimDesigner
Create P P P P
Global
Sensors
Create P P P
Local
Sensors
Create P P P P
Reaction
Sensors
Applied
Load
Sensors
Internal
Load
Sensors
Multi Load
Sensors
Inertia
Sensors
Chapter 2: Features Supported 35
SimDesigner Structures Workbench
Results Computation
Commands CATIA V5 SimDesigner
External
Storage
External
Storage
Clean-up
Temporary
External
Storage
Computing P
Computing
with
Adaptivity
Computing
using Batch
SD Setup P P
Batch
SD Storage P
Manager
36 Release Guide
SimDesigner Structures Workbench
Results Visualization
Commands CATIA V5 SimDesigner
Deform- P P P P
ation
Von Mises P P P
Stresses
Displaceme P P P
nts
Principal P P P
Stresses
Precisions P P
Generate P P P
Reporting
History of
Computatio
n
SD XY Plot P P P
Elfini
Solver Log
Animate P P P P
Image
Chapter 2: Features Supported 37
SimDesigner Structures Workbench
Cut Plane P P P P
Analysis
Amplificat- P P P
ion
Magnitude
Extrema P P P
Detection
Information P P P
Contextual Menu
Commands CATIA V5 SimDesigner
Update P P P P
Group
Update All P P P P
Groups
Analyze P P P P
Group
Local
Adaptivity
Create
Preprocessing Set
Add Solution
Chapter 2: Features Supported 39
SimDesigner Structures Workbench
P P P P
P P P P
P P P P
Mesh P P P P
Visualizat-
ion
40 Release Guide
SimDesigner Structures Workbench
Restraint P P P P
Visualizat-
ion on mesh
Pressure P P P P
Visualizat-
ion on mesh
Masses
Visualization on
mesh
Generate P P P P
Image
Generate P P P P
2D Display
for Sensor
Generate
2D Display
for
Modulation
Generate
2D Display
for dynamic
response
solutions
Chapter 2: Features Supported 41
SimDesigner Structures Workbench
Contact
Contact P P P
Material
Commands CATIA V5 SimDesigner
P P
42 Release Guide
SimDesigner Structures Nonlinear Workbench
Analysis Cases
Commands CATIA V5 SimDesigner
Analysis Case GWX functionalities shown here are applicable within the context of
SDX
SD Nonlinear P P
Case
Large displacement and large strain problems can be computed only with GPS.
Chapter 2: Features Supported 43
SimDesigner Structures Nonlinear Workbench
Model Manager
Commands CATIA V5 SimDesigner
3D Mesh Part P P
2D Mesh Part P P
Local Mesh P P
Sizes
Element Type P P
3D Property P P
2D Property P P
Beam Property P P
User Material P P
Mesh Creation
Commands CATIA V5 SimDesigner
3D Mesh Part P P
2D Mesh Part P P
1D Mesh Part
Mesh Specifications
Commands CATIA V5 SimDesigner
Local Mesh P P
Sizes
Element Type P P
Chapter 2: Features Supported 45
SimDesigner Structures Nonlinear Workbench
Adaptivity
Commands CATIA V5 SimDesigner
Adaptivity P P
Boxes
Analysis Assembly
Commands CATIA V5 SimDesigner
Analysis P,A
Assembly 2D
Viewer
46 Release Guide
SimDesigner Structures Nonlinear Workbench
Virtual Parts
Commands CATIA V5 SimDesigner
Rigid Virtual P P
Parts
Smooth Virtual P P
Parts
Contact Virtual
Parts
Rigid Spring P P
Virtual parts
P P
Spring smooth P P
virtual parts
Periodicity
Conditions
Contact
Commands CATIA V5 SimDesigner
Contact P P, Nonlinear
Workbench
Chapter 2: Features Supported 47
SimDesigner Structures Nonlinear Workbench
Material
Commands CATIA V5 SimDesigner
P P, Nonlinear
Workbench
Mass Equipment
Commands CATIA V5 SimDesigner
Distributed Mass
Line Mass
Densities
Surface Mass
Densities
48 Release Guide
SimDesigner Structures Nonlinear Workbench
Restraints
Commands CATIA V5 SimDesigner
Clamps P P
Surface Sliders P P
Ball Joins P P
Sliders P P
Pivot P P
Sliding Pivots P P
Advanced P P
Restraints
Iso- Static P P
Restraints
Chapter 2: Features Supported 49
SimDesigner Structures Nonlinear Workbench
Loads
Commands CATIA V5 SimDesigner
Pressure P P
Distributed P P
Forces
Moment P P
Line Force P P
Density
Surface Force P P
Density
Volume Force P P
Density
Accelaration P P
Rotation Force P P
50 Release Guide
SimDesigner Structures Nonlinear Workbench
Enforced P P
Displacement
Pre-Stress
P, Nonlinear P, Nonlinear
Workbench Workbench
Reference P P
Temperature
Field
Images Layout P P
Sensors
Commands CATIA V5 SimDesigner
Create Sensors
(static Analysis
Case)
Create Sensors (
Frequency
Analysis Case)
Create Sensors (
Buckling Case)
Chapter 2: Features Supported 51
SimDesigner Structures Nonlinear Workbench
Groups
Commands CATIA V5 SimDesigner
Result Computation
Commands CATIA V5 SimDesigner
Specify External
Storage
Clear External
Storage
Temporary Data
Directory
Computing P
Object Sets
Managing
Adaptivity
Use a Batch
SD Setup Batch P
SD Storage P
Manager
Chapter 2: Features Supported 53
SimDesigner Structures Nonlinear Workbench
Results Visualization
Commands CATIA V5 SimDesigner
Generate Image P P
Deformation P P
Von Mises P P
Stresses
Displacements P P
Principal stresses P P
Precisions
Generate Report P P
Historic of
Computation
SD XY Plot P P
Animate Image P P
54 Release Guide
SimDesigner Structures Nonlinear Workbench
Cut Plane P P
Analysis
Amplification P P
Magnitude
Extrema P P
Detection
Information P P
Contextual Menu
Commands CATIA V5 SimDesigner
Extrema P P
Detection
Information P P