HIGH EFFICIENCY COMMERCIAL BOILERS

CON·X·US® REMOTE CONNECT

MODBUS AND BACnet MSTP PROTOCOL

CASCADING SEQUENCER WITH


CASCADE REDUNDANCY

12 INPUTS FROM 750,000 TO 6.0 MILLION BTU/HR

UP TO 25:1 TURNDOWN RATIO

DIRECT-VENTING UP TO 100 FEET USING PVC, CPVC,


POLYPROPYLENE OR STAINLESS STEEL

FLEXIBLE FLOW RATES UP TO 600 GPM

FRONT END LOADING CAPABILITY


UP TO 96.2%
Thermal Efficiency

Registered under U.S. Patent #9,746,176

L o c h i n v a r.c o m
RIDE THE LOCHINVAR WAVE™
UP TO 6.0 MILLION BTU & 96.2% EFFICIENCY
With the exclusive Wave fire-tube design, advancements in Lochinvar
combustion technology and the SMART TOUCH™ control with CON·X·US, CREST
changed how the industry thinks about fire-tube boilers. Now you have the
opportunity to use all of these features in sizes ranging from 750,000 to 6.0
million BTU/hr and delivering up to 96.2% thermal efficiency.

THE CREST COMBUSTION SYSTEM


CREST boilers are equipped with a top-mounted micro-metal fiber
burner, engineered specifically for fire-tube technology. The system is
designed to ensure smooth, quiet modulating combustion with up to
25:1 turndown. A FBN-2001 fires at its maximum 2,000,000 Btu/hr
rate when the heat load is highest, and then gradually turns down to
as low as 4% (80,000 Btu/hr) as load decreases. A modulating system
runs smoothly and efficiently, without frequent on/off cycling. When
the system is zoned, CREST’s high turndown works to match the actual
system demand. In return, CREST reduces the customer’s fuel bill and
provides better comfort by load-matching the heat loss of the system.

REDUCE INSTALLATION COST WITH


VARIABLE FLOW TECHNOLOGY
CREST can operate over a wide range of flow rates with very low
pressure drop. This permits installation of a full flow (variable primary)
system. Installation is streamlined, without the time and materials cost
of primary/secondary piping, and pumps needed to maintain flow in a
water-tube boiler. Variable flow also makes CREST more flexible at
handling frequent fluctuations in the system flow rate.

HIGH EFFICIENCY WITH MINIMUM


SUPPLY PRESSURE
CREST operates reliably with supply gas pressure as low as 4 inches
water column. Negative Regulation technology draws gas into a
pre-mix combustion system, instead of relying on utility pressure
through the gas valve. Operation is steady in low gas pressure systems
or when peak gas supply demand occurs. Plus, Neg/Reg fan control
fine-tunes the fuel/air ratio entering the burner, providing an even,
cleaner-burning flame, achieving high combustion efficiency.
INTRODUCING BOILER PLANT
CONTROL, FROM ANYWHERE.
Crest features the next generation of Lochinvar’s all-in-one SMART TOUCHTM
operating control with the integration of the CON·X·US® advanced technology.
SMART TOUCH with CON·X·US provides outstanding functionality, and can
be integrated directly into a Building Automation System via Modbus
and BACnet MSTP as standard equipment.
And now, the CON·X·US mobile communication platform allows the
SMART TOUCH to go where no other boiler has gone before.
CON·X·US provides the ability to monitor and manage multiple Crest boiler
plants without ever stepping into the mechanical rooms. CON·X·US will send
alerts via text or email notifying of changes in system status, and anytime, from
anywhere, a user can check system status and re-program boiler functions.
Once downloaded, the free CON·X·US mobile application allows for remote
access to all SMART TOUCH functions using any internet-capable device.

PEACE OF MIND, WHEN IT MATTERS MOST


Cascade Redundancy provides peace of mind because it helps ensure that a
CREST boiler system will always deliver reliable performance with no downtime.
If the lead boiler is turned off for maintenance, Cascade Redundancy
automatically shifts the lead role to the second sequenced boiler. Up to eight
CREST boilers can be sequenced using a 2-wire daisy-chain connection.
Cascade sequencing can be programmed for Lead-Lag or Efficiency Optimized
operation.

With Lead-Lag operation, one lead boiler modulates to capacity on demand.


As load increases, the system then cascades to additional lag boilers in
sequence. The first-on role shifts daily, distributing equal runtimes to each unit.

In an Efficiency Optimized system (see illustration below), all boilers fire and
modulate simultaneously at the same Btu/hr input rates, maximizing thermal
efficiency.

1 2 3 4 5 6 7 8
FLEXIBLE VENTING OPTIONS
CREST offers 6 venting options, and permits direct-vent air intake and exhaust runs
up to 100 equivalent feet, using PVC, CPVC, polypropylene or stainless steel pipe.**
Plus, multiple units can be common-vented to reduce time and materials cost.

Room Air Vertical Room Air Sidewall Direct-Vent Common-Vent* Direct-Vent Vertical Vertical w/Sidewall Air

*Contact Lochinvar for information on common venting of CREST boilers.


** Avaiable for models FB 0751-3501. Stainless steel pipe only for models FB 4001-6001.
SUPERIOR FIRE-TUBE
HEAT EXCHANGER
DESIGN BOOSTS
THERMAL EFFICIENCY
The CREST boiler takes fire-tube technology to
a new level. The patented Wave™ configura-
tion creates turbulence as flue gas products
flow down the tube, scrubbing the energy
from the flue products. The Wave design also
enhances the life of the heat exchanger by
allowing the tubes to flex, so they operate
stress free with none of the adverse effects
suffered by traditional fire-tube boilers.

Each fire tube is welded into the heat


exchanger and surrounded by water, and the
heat transfer process is enhanced by the
water’s counterflow. As water flows up inside
the vessel, super-heated flue products flow
down the fire tube. With one pass, heat is
effectively captured, reaching condensing
temperatures. At the top of the vessel, the
combustion chamber is also water-backed for
additional heat transfer.

CREST BOILER EFFICIENCY


100%
99%
98% Efficiency @ 5%
Efficiency @ 50%
97%
Efficiency @ 100%
96%
95%
Efficiency%

94%
93%
92%
91%
90%
89%
88%
87%
86%
85%
60 70 80 90 100 110 120 130 140 150 160 170
Water Return Temperature @ 20°F Rise
CREST® BOILER DIMENSIONS AND SPECIFICATIONS
®

R
SIDE BACK TOP

Q
K
A L

P
M
F J

D N
G H
C O
B

Crest Heating Boiler Dimensions and Specifications


Input MBH Water Oper. Ship.
Gross
Model Net Turn- Gas Air Vent Weight
Thermal Output A B C D E F G H J K L M N O P Q R Weight
Number Min Max Rating down Conn. Inlet/ Intake Size (with
% MBH Outlet water) (lbs.)
MBH
FB*0751 50 750 96.2% 722 627 15:1 78” 30” 55-1/2” 57-5/8” 66-1/8” 11-7/8” 11-3/8” 11-1/4” 12-1/2” 55” 51” 13” 8-3/4” 26-3/4” 23-3/4” 49-1/2” 7-3/8” 1-1/4” 3” 6” 6” 1,768 1,560
FB*1001 50 1,000 96.2% 962 837 20:1 78” 30” 56-1/2” 57-5/8” 66-1/8” 11-7/8” 11-3/8” 11-1/4” 12-1/2” 56” 51” 13” 8-3/4” 26-3/4” 23-1/8” 49-1/2” 6-1/2” 1-1/4” 3” 6” 6” 1,838 1,596
FB*1251 63 1,250 96.2% 1,203 1,046 20:1 78” 30” 56-1/2” 57-3/4” 66-1/8” 11-7/8” 11-3/8” 11-1/4” 12-1/2” 56” 51-3/8” 13” 8-3/4” 26-3/4” 21-5/8” 49-1/2” 6-1/2” 1-1/4” 3” 6” 8” 1,975 1,648
FB*1501 60 1,500 96.2% 1,443 1,255 25:1 78” 30” 67-3/4” 68” 65-3/8” 12-3/8” 11-3/8” 11-1/4” 12-1/2” 67-1/4” 62-3/8” 15-7/8” 9” 26-7/8” 27-7/8” 59-1/4” 5-1/8” 1-1/2” 4” 8” 8” 2,307 1,961
FB*1751 70 1,750 96.2% 1,684 1,464 25:1 78” 30” 66-1/4” 68” 65-3/8” 12-3/8” 11-3/8” 11-1/4” 12-1/2” 65-3/4” 61-1/2” 15-7/8” 9” 27” 27-1/8” 58-3/4” 5-1/8” 1-1/2” 4” 8” 8” 2,458 2,017
FB*2001 80 1,999 96.2% 1,924 1,673 25:1 78” 30” 66-1/2” 68” 65-3/8” 12-3/8” 11-3/8” 11-1/4” 12-1/2” 66” 61-1/2” 15-7/8” 9” 27” 26-3/4” 58-3/4” 5-1/8” 1-1/2” 4” 8” 8” 2,570 2,087
FB*2501 125 2,500 96% 2,400 2,087 20:1 77-3/4” 35” 83-3/4” 83-3/4” 63-3/4” 13-1/2” 11-1/4” 10-1/2” 12-1/4” 83-1/4” 76-1/4” 19-3/4” 9-1/4” 28-3/4” 32” 71” 7-1/4” 2” 4” 8” 9” 3,600 2,577
FB*3001 150 3,000 96% 2,880 2,504 20:1 77-3/4” 35” 83-3/4” 83-3/4” 63-3/4” 13-1/2” 11-1/4” 10-1/2” 12-1/4” 83-1/4” 76-1/4” 19-3/4” 9-1/4” 28-3/4” 32” 71” 7-1/4” 2” 4” 10” 10” 3,900 2,881
FB*3501 175 3,500 96% 3,360 2,921 20:1 77-3/4” 42” 91-1/2” 86-3/4” 63-1/2” 13-1/4” 11-1/2” 10-3/4” 12-1/2” 91” 82” 20-1/4” 12-3/4” 35-1/2” 31-3/4” 73-1/4” 8-3/4” 2” 4” 10” 10” 4,600 3,218
FB*4001 333 3,999 96% 3,840 3,339 12:1 77-3/4” 45-1/2” 103-1/2” 99” 63-1/2” 13-3/4” 11-1/2” 10-3/4” 12-1/2” 103” 94” 24-3/4” 13-1/2” 39-1/2” 42-1/4” 85-1/4” 10-1/2” 2-1/2” 4” 12” 12” 5,200 3,805
FB*5001 500 4,999 96% 4,800 4,173 10:1 77-3/4” 46-1/2” 102-1/4” 99-1/2” 63-1/2” 15” 11-1/2” 10-3/4” 12-1/2” 101-3/4” 92-1/2” 22” 14” 39-3/4” 39-1/2” 84” 9” 2-1/2” 6” 12” 14” 5,900 4,101
FB*6001 600 6,000 96% 5,760 5,008 10:1 77-3/4” 50” 102-3/4” 99-3/4” 63-1/4” 14-3/4” 11-1/2” 10-3/4” 12-1/2” 102-1/2” 93-1/4” 20” 15-3/4” 43-1/2” 36-1/2” 83-3/4” 9-1/4” 2-1/2” 6” 14” 14” 6,900 4,711
Notes: *Insert “N” for natural gas, “L” for LP gas models and “D” for dual fuel.Indoor installation only. Information subject to change without notice. Lochinvar should be consulted before selecting a boiler for
installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. The ratings have been determined under the provisions governing forced draft burners. The Net
AHRI water ratings shown are based on a piping and pickup allowance of 1.15.
Smart Touch™ Features Codes & Registrations
CON·X·US Remote Connect High-Voltage Terminal Strip ASME Certified, “H” Stamp / National Board
SMART TOUCH Touchscreen Operating Control > 120 VAC / 60 Hertz / 1 Phase Power Supply California Code Compliant
Full-Color 8" Touchscreen LCD Display (FB 0751-2001) CSD1 / Factory Mutual / GE Gap Compliant
Built-in Cascading Sequencer for up to 8 Boilers > 208 VAC/ 60 Hertz/ 3 Phase Power Supply Canadian Registration Number (CRN)
> Built-in Redundancy (FB 2501-3501) South Coast Air Quality Management District Qualified
> Cascade Multiple Sized Boilers > 480 VAC/60 Hertz/3 Phase Power Supply (FB 0751-2001)
> Lead/Lag Cascade (FB 4001-6001)
> Efficiency Optimized Cascade System Pump, Boiler Pump and DHW Pump Power
Front-End Loading Capability with Copper-Fin II® Low-Voltage Terminal Strip Standard Features
and Power-Fin® Boilers > 24 VAC Auxiliary Device Relay Up to 96.2% Thermal Efficiency
Building Management System Integration > Auxiliary Proving Switch Contacts Proof of Closure Valve (6001)
with 0-10 VDC Input > Alarm on Any Failure Contacts Modulating Burner with up to 25:1 Turndown
BACnet MSTP Communications > Runtime Contacts Direct-Spark Ignition
Modbus Communication > DHW Thermostat Contacts Low NOx Operation
Outdoor Reset Control with Outdoor Air Sensor > Unit Enable/Disable Contacts Sealed Combustion
Password Security > System Sensor Contacts Air Inlet Filter w/Replacement Reminder Low
Domestic Hot Water Prioritization > DHW Tank Sensor Contacts Gas Pressure Operation
> DHW tank piped with priority in the boiler loop > Outdoor Air Sensor Contacts Vertical and Horizontal Direct Venting
> DHW tank piped as a zone in the system with the > Cascade Contacts > Direct Vent up to 100 Feet
pumps controlled by the Smart System > 0-10 VDC BMS External Control Contact > PVC, CPVC, Polypropylene or AL29-4C (FB 0751-3501)
> DHW Modulation Limiting > 0-10 VDC Variable Speed Boiler Pump Control Contact > AL29-4C (FB 0751-6001)
> Separately Adjustable SH/DHW Switching Times ASME “H” Stamped Heat Exchanger
Low Water Flow Safety Control & Indication
Inlet & Outlet Temperature Readout
Optional Equipment 316L Stainless Steel Fire Tubes
Alarm Bell 160 psi Working Pressure
Freeze Protection BMS Gateway - BACnet IP or LonWorks On/Off Switch
Service Reminder Wireless Outdoor Temperature Sensor Adjustable High Limit with Manual Reset
Time Clock Condensate Neutralization Kit Low Water Cutoff with Manual Reset & Test
Data Logging Common Vent Kits Damper High & Low Gas Pressure Switches w/Manual Reset
> Hours Running, Space Heating Motorized Isolation Valve Low Air Pressure Switches
> Hours Running, Domestic Hot Water Variable Speed Boiler Pump Condensate Trap w/Blocked Drain Switch
> Hours Running, Modulation Rate Electrical Options (Shipped Loose): Drain Valve
> Ignition Attempts FB 0751-2001 System Sensor
> Last 10 Lockouts > 208V/1Ø/60Hz → 120V/1Ø/60Hz Outdoor Air Sensor
Programmable System Efficiency Optimizers > 480V/1Ø/60Hz → 120V/1Ø/60Hz Inlet & Outlet Temperature Sensors
> Night Setback > 600V/1Ø/60Hz → 120V/1Ø/60Hz High-Voltage Terminal Strip
> Anti-Cycling FB 2501-3501 Low-Voltage Terminal Strip
> Outdoor Air Reset Curve > 480V/3Ø/60Hz → 208V/3Ø/60Hz Downstream Gas Test Cocks
> Ramp Delay > 600V/3Ø/60Hz → 208V/3Ø/60Hz 50 psi ASME Relief Valve
> Boost Temperature & Time FB 4001-6001 Temperature & Pressure Gauge
> Modulation Factor Contro > 600V/3Ø/60Hz → 480V/3Ø/60Hz Zero Clearances to Combustible Materials
Three Pump Control High Altitude Models Available
> System Pump 10-Year Limited Warranty (See Warranty for Details)
> Boiler Pump 1-Year Warranty on Parts (See Warranty for Details)
*Lochinvar should be consulted before selecting a boiler for installations
> Domestic Hot Water Pump
having unusual piping and pickup requirements, such as intermittent
system operation, extensive piping systems, etc. *The ratings have been
determined under the provisions governing forced draft burners.

Lochinvar, LLC
300 Maddox Simpson Parkway
Lebanon, Tennessee 37090
P: 615.889.8900 | F: 615.547.1000
Lochinvar.com 0751-2001

FBNT-04 TEMP (Replace FBNT-03 2/18) © Lochinvar, LLC - ASB - 5M 2/18 - Printed in U.S.A.