You are on page 1of 1

SQUARE AND RECTANGULAR COLUMN - ASPECT RATIO < 1.

5
FYFE ASIA PTE LTD Date/ Design by: August 22, 2018
PROJECT: PHILIPPINE SCIENCE HIGH SCHOOL-MAIN Location/Ref.: Column C8
 
AXIAL CAPACITY ENHANCEMENT OF SQUARE / RECTANULAR COLUMN (H/B < 1.5) WITH TYFO FIBRWRAP SYSTEMS
MAIN
Material SEH51 (Choose either of SEH51, SCH11, SCH41) Code: BS8110
L
tgv

L tgh
H

Design Assumptions:
B = Width of Column B= 600 mm
H = Height of Column H= 600 mm
Aspect Ratio H/B = 1
2
fcu = Crushing strength of concrete fcu = 34.5 N/mm
2
fy = Characteristic Strength of steel reinforcement fy = 414 N/mm
2
As = Area of longitudinal steel As = 9817.477 mm
2
Ac = Area of concrete Ac = 350182.5 mm Ni= Increase in axial capacity after wrapping
nv = No.of layers with primary fibres vertical nv = 3 layer(s) = (1.05fcu+k1)(B+H)tgh + k2(B+2L)tgv Ni = 2258.38 kN
nh = No.of layers with primary fibres horizontal nh = 8 layer(s)
tgv = Total thickness of composite in vertical direction tgv = 3.9 mm % increase in axial load carrying capacity Ni/No*100 %incr.= 32.49%
tgh = Total thickness of composite in horizontal direction tgh = 10.4 mm
L = Length of flange of C- Channel L= 300 mm Note:- The above emperical formula is product specific, derived based on extensive
research conducted on TYFO FIBRWRAP Systems throughout the world
No = Original axial capacity= 0.35fcu*Ac + 0.67fy*As No = 6951.63 kN and cannot be used with any other product.
2
k1 = Constant 1 k1 = 85.86 N/mm
2
k2 = Constant 2 k2 = 157.00 N/mm