Gas Fired

Wall-mounted electronic boilers.


Basic characteristics of the LAURA PLUS Range (Efficient small storage)

programmer
combustion
D.H.W instant

combined

Low NOx
Heating output D.H.W. heat output
flow rate

Sealed
Instant

IP 44
With
Model Kcal/h kW Kcal/h kW l/min ∆t=25°C
Heating and instant hot water
LAURA PLUS 28/28 3.440 /24.080 4 / 28 24.080 28 16 • CL.2 • •
LAURA PLUS 28/28 F 3.440 /24.080 4 / 28 24.080 28 16 • • CL.3 • •

Basic characteristics of the LAURA Range (Efficient small storage)


D.H.W.
Storage

programmer
combustion
D.H.W. instant
Heating output tank

combined

combined

Low NOx
heat output flow rate

Storage

draught
capacity

Sealed

Forced
Instant
l/min

IP 44
With
Model Kcal/h kW Kcal/h kW ∆t=25°C Litres
Heating and instant hot water
LAURA 20/20 7.000 / 20.000 8,1 / 23,3 20.000 23,3 13,4 - • CL.2 • •
LAURA 20/20 F 7.000 / 20.000 8,1 / 23,3 20.000 23,3 13,4 - • • CL.3 • •
LAURA 20/20 T 7.000 / 20.000 8,1 / 23,3 20.000 23,3 13,4 - • • CL.2 • •
LAURA 35/35 8.000 / 30.000 9,3 / 35,0 30.000 35,0 20,1 - • CL.2 • •
LAURA 35/35 F 8.000 / 30.000 9,3 / 35,0 30.000 35,0 20,1 - • • CL.3 • •
Heating and domestic hot water by storage
LAURA 20 A 7.000 / 20.000 8,1 / 23,3 - - - 60 to 500 • CL.2 • •
LAURA 20 AF 7.000 / 20.000 8,1 / 23,3 - - - 60 to 500 • • CL.3 • •
LAURA 35 A 8.000 / 30.000 9,3 / 35,0 - - - 60 to 500 • CL.2 • •
LAURA 35 AF 8.000 / 30.000 9,3 / 35,0 - - - 60 to 500 • • CL.3 • •

Basic characteristics of the VEGA PLUS Range (integral cylinder)


30-min DHW Continuous

combustion
Storage
production production

combined
Heating output D.H.W. heat output tank

Low NOx
included
Storage
Stored DHW. of DHW

IP X 5D
Sealed
capacity

Tank
temp 60 °C
Model kcal/h kW kcal/h kW Litres(∆t=30 °C) l/min (∆t=25 °C) Litres
VEGA PLUS 24 AIM 8.944 / 20.984 10,4 / 24,4 8.944 / 20.984 10,4 / 24,4 390 14 Approx. 60 • • CL.3 •
VEGA PLUS 28 AIM 8.944 / 24.080 10,4 / 28 8.944 / 24.080 10,4 / 28 450 16 Approx. 60 • • CL.3 •
VEGA PLUS 24 AIFM 8.944 / 20.984 10,4 / 24,4 8.944 / 20.984 10,4 / 24,4 390 14 Approx. 60 • • • CL.3 •
VEGA PLUS 28 AIFM 8.944 / 24.080 10,4 / 28 8.944 / 24.080 10,4 / 28 450 16 Approx. 60 • • • CL.3 •

Basic characteristics of the DEIMOS Range (Exposed and Built-in)


programmer
combustion

D.H.W instant
combined

Low NOx
Heating output D.H.W. heat output

IP X 5D
flow rate
Sealed
Instant

With

Model Kcal/h kW Kcal/h kW l/min ∆t=25°C


Heating and instant hot water
DEIMOS SPACE 24/24 F 8.000 / 20.645 9,3 / 24 20.645 24 13,8 • • Op. CL.3 •
DEIMOS BOX 24/24 F 8.000 / 20.645 9,3 / 24 20.645 24 13,8 • • Op. CL.3 •

EFFICIENT SMALL STORAGE INTEGRAL CYLINDER EXPOSED BUIL-IN

RX 200
PLUS

DEIMOS SPACE DEIMOS BOX

LAURA PLUS Range LAURA Range VEGA PLUS Range DEIMOS Range

10
Gas Fired
Wall-mounted electronic boilers. LAURA Range
Main features
- Analogue-digital tilt forward type control cathodic protection system or with an - Solar kit for DHW production in systems
panel with built-in programming feature. enamelled storage cylinder with cathodic made up by solar panels, main storage
- Large LCD display with all the necessary protection as standard (see «Enamelled cylinder and individual wall-mounted combi
information (LED back-lighting). Storage Cylinders») which could optionally boilers (see «Installation Accessories»
- Indicator lamps and warning alarms. be fitted with an electric heater element. section).
- Combi boilers with instant DHW production. LAURA 20 AF and LAURA 35 AF - Universal replacement kit to make
High Domestic Hot Water delivery at - Room-sealed air supply safety through a installation of our wall-mounted boilers
constant temperature. pressure switch. easier in place of other models and/or
Exclusive Hydroplus and ATACSS - High-efficiency, monothermic heat makes (see “Installation Accessories”
systems (See “Outstanding Features of exchanger. section).
LAURA Boilers”). - The LAURA 20 AF and LAURA 35 AF
- Comfort in DHW, according to should combine with a stainless steel
pr/EN 13203. storage cylinder (see «Stainless Steel
- Heating Pressure Switch. Storage Cylinders») which could optionally
It prevents the boiler from operating with be fitted with an electric heater element
underpressure in the heating circuit. and/or cathodic protection system or with
- Temperature control accurate within 1°C. an enamelled storage cylinder with
- Permanent information about current cathodic protection as standard (see
service temperatures. «Enamelled Storage Cylinders») which
- Permanent information about the output could optionally be fitted with an electric
modulation. Modulation of output by means heater element.
of dedicated PID management system.
- Electronic ignition and flame safeguard LAURA 20/20 and LAURA 35/35
rectification system. - Vertical draught diverter.
- High efficiency according to the - Flue Spillage Limit Thermostat.
Efficiency Directive 92/42/EEC. - High-efficiency, bi-thermic heat exchanger.
- Eco-friendly. Low NOx emission level (NOx
2 and 3 class). LAURA 20/20 F, LAURA 20/20 T and
- Quiet operation. Room-sealed models LAURA 35/35 F
feature a two-speed exhaust fan. - Room-sealed air supply safety through a
- Possibility of adjusting Central Heating pressure switch.
output. - High-efficiency, bi-thermic heat exchanger.
- Coded digital information about possible
faults.
- Exclusive just-in-time detection and flow
Delivery
variation monitoring system (LAURA combi LAURA 20 A, LAURA 35 A,
boilers with instantaneous DHW LAURA 20/20 and LAURA 35/35
production) (See “Outstanding Features of In a single package:
LAURA Boilers”). - Boiler with all its working parts duly
- Automatic by-pass for single-pipe assembled, and outer casing.
systems, or with thermostatic valves.
- Pump seizure protection feature. LAURA 20/20 F, LAURA 20/20 T,
- Frost protection, enabling you to go LAURA 35/35 F, LAURA 20 AF
without worrying about the rigours of and LAURA 35 AF
winter. In two packages:
- Models for use with natural gas incorporate - Boiler with all its working parts duly
a gas pressure regulator. assembled, and outer casing.
- Can be located between kitchen fittings. - Flue duct.
- Electrical Protection Level IP44.
- Metal wall-mounting bracket and screws Optional supply
(LAURA 20 range only) with installation - Room thermostat, programmable room
template (paper) for correct positioning of thermostat, or wireless programmable
fixings and service connections. room thermostat.
- Home automated connection to a - Extensions and elbows for the flue & air
computer via modem. duct system (See “Accessories for room-
sealed and fan-flued boilers”).
The following models also incorporate: - Full pre-plumbing jig comprising: Wall-
mounting bracket (LAURA 20 range only),
LAURA 20 A and LAURA 35 A paper template, tap rail for hydraulic test
- Vertical draught diverter. and pipe positioning, cocks, screws, pipes
- Flue Spillage Limit Thermostat. & fittings.
- High-efficiency, monothermic heat - Chassis-Wall Spacing Frame to allow fitting
exchanger. the boiler with exposed installation through
- The LAURA 20 A and LAURA 35 A should the rear of the boiler.
combine with a stainless steel storage - TELETHERM-MT2 module (for starting/
cylinder (see «Stainless Steel Storage stopping the boiler by telephone) See
Cylinders») which could optionally be fitted "Thermostates and equipment for control".
with an electric heater element and/or

23
Gas Fired
Wall-mounted electronic boilers. LAURA Range
Technical Specifications common to all models Pump Performance Graph
- Pump condenser capacity: 3,5 µF
- Power supply: 230 V - 50 Hz single phase LAURA 20/20, LAURA 20/20 F and
- Net efficiency: ( according to Directive 92/42/EEC) 93,4% LAURA 20/20 T
- DHW priority: Yes 6.0
- Heating and DHW output: Modulating
5.0
- Control system: Electronic

Height on water gauge


- DHW temperature selection: From control panel 4.0
3
- Min. lighting pressure for DHW: 0,3 bar 3.0
2
- Min. lighting flowrate for DHW: 3 l / min. 2.0
- Lighting: Electronic-automatic ignition 1
1.0
- Pilot flame: No
- Flame control: Ionisation sensor 0

- Max. working pressure of heating circuit: 3 bar 0 0.2 0.4 0.6 0.8 1 1.2 1.4
Flow (m³/h)
- Max. working temperature of heating circuit: 90°C
- Gross capacity of expansion vessel: 8 /12 l
- Expansion vessel fill pressure: 0,75 bar LAURA 20 A and LAURA 20 AF
- Max. working pressure of DHW circuit: 7 bar
- Max. working temperature of DHW circuit: 60°C 6.0

- Approx. weight: (natural draught modelsl): 43 kg 5.0


- Type of electrical protection IP 44

Height on water gauge


4.0
- Daily schedule programming feature: Available as standard feature 2 3
3.0
- Quality of DHW, according to pr/EN 13203
1
2.0

Natural Propane / Butano 1.0


Gas
G-20 G-31 / G-30 0
L.H.O. kcal/m³ (st) 8.130 21.030 / 27.750 0 0.2 0.4 0.6 0.8 1 1.2 1.4
Gas category II 2 H 3 + II 2 H 3 + Flow (m³/h)

Input rate (m3 (st)/h) at 15°C and 1.013 mbar 2,74 (*) 1,06 / 0,9
Nominal gas inlet pressure (mbar) 20 37 / 29 LAURA 35/35 and LAURA 35/35 F
Burner setting pressure (mbar) 9,5 34,1 / 25,3 7.0

Ø Burner injector size (mm) 1,30 0,75 6.0

(*) Gas input rate for LAURA 20/20 in DHW service. 3


5.0
Height on water gauge

2
4.0

3.0
Control panels 2.0
1

LAURA 35 A, LAURA 35 AF, LAURA 20/20, LAURA 20/20 F, LAURA 20/20 T, 1.0

LAURA 20 A and LAURA 20 AF LAURA 35/35 and LAURA 35/35 F 0


0 0.2 0.4 0.6 0.8 1 1.2 1.4
12 11 10 9 6 2 1 12 11 10 9 7 6 3 15 1 Flow (m³/h)

LAURA 35 A and LAURA 35 AF

6.0

5.0
3
2
Height on water gauge

4.0

3.0
1
13 14 8 5 4 13 14 8 5 4 2.0

1.0

0
1 - Pressure gauge 8 - Temperature Control Knob 0 0.2 0.4 0.6 0.8 1 1.2 1.4
2 - Heating Service 9 - Digital Screen Flow (m³/h)
3 - DHW Service 10 - Set Time
4 - Off 11 - Validate Programme
5 - Fault Warning and Reset 12 - Manual/Programme Modes
6 - Set Heating Temperature 13 - Set Timer
7 - Set DHW Temperature 14 - Timer Control Knob
15 - Heating Service + DHW

Separate storage cylinder for wall-mounted combi boilers.

Installatión.
See "Separate storage cylinder for wall-mounted combi boilers".

24
Gas Fired
Wall-mounted electronic boilers. LAURA Range
Dimensions and Technical Data
(1) For the forced-draught model (T) this dimension is 140 mm.
L máx. (4) (2) In LAURA 20, the ID = 127 mm for use of 125mm OD flue ducts.

150 (1)
247 In the LAURA 35, the ID = 152 mm for use of 150mm OD flue ducts.
(2) Ø int. (3) In LAURA 35 A, LAURA 35 AF, LAURA 35/35 and LAURA 35/35 AF, 535 mm.

Concentric Concentric Twin-pipe Single Flue


250 (4) L máx. Flue Pipe Flue Pipe Flue System Pipe
Ø 60/100 Ø 80/125 2 x Ø 80 Ø 80
850

850
LAURA 20 AF, 20/20 F 3 m. 13 m. 10 m. -
LAURA 35 AF, 35/35 F 3 m. 13 m. 22 m. -
LAURA 20/20 T - - - 36 m.
With room-sealed (F) models, the factory-supplied flue kits are of the
450 (3) 392 450 (3) 392 concentric type 60/100 mm in diameter or twin-type of 80 mm diameter.
A wide range of concentric flue pipes of 80/125 mm is also available.

Natural draught models. Room-sealed air intake, forced-draught With fanned flue (T) models, the factory-supplied flue kit is Ø 80 mm.
models.

Models for natural gas are equipped with a gas governor as standard that
permits adjusting and stabilising the gas supply to the boiler

Water connections bracket and template


As an option, a pre-plumbing jig with all the necessary
fittings for connection and for the hydraulic test can be
supplied.

PMI-LAURA 20 PMA-LAURA 20 Wall spacing frame Wall spacing frame


with cocks with cocks LAURA 20 LAURA 35
Kit for Kit for
LAURA 20/20, LAURA 20 A and
LAURA 20/20 F and LAURA 20 AF
LAURA 20/20 T

1
1
2
3 6
4 3
5 5

PMI-LAURA 35 PMA-LAURA 35
with cocks with cocks
Kit for Kit for
LAURA 35/35 and LAURA 35 A and
LAURA 35/35 F LAURA 35 AF
3 3

1
2 1
3 6
4 3
5
5

1 2 3 4 5 6
Holes Heating Domestic. Gas Cold water Heater Storage cylinder
flow Hot Water Natural and Propane Inlet Return flow
Boiler connection 3/4" 1/2" 3/4" 3/4" 3/4" 1/2"
Ø of connec. pipe (mm) 16-18 13-15 16-18 13-15 16-18 13-15

Distance among connections


60 60 60 60

The PMI-LAURA 35 and PMA-LAURA 35 kits differ from the PMI-LAURA 20 and PMA-LAURA 20 in that the diameter of the heating flow and
return pipes is 18-20.

25
Gas Fired
Wall-mounted electronic boilers. LAURA PLUS and LAURA Range
Outstanding Features of LAURA Boilers
(Combi boilers with instant DHW production)

In addition to state-of-the-art electronics technology, inherent in all


Roca wall-mounted boilers, the LAURA model incorporates not one or
two, but three ground-breaking devices whose objective is to achieve
perfection: The ATACSS system, the just-in-time, and the
hydroplus system.

ATACSS System (Temperature Assurance of Domestic Hot Water


Selected)

It consists of a simple system by which the boiler allows passage of


the water volume that permits assuring that the boiler will be capable Sensor
of heating to the selected temperature.
Flow meter
The LAURA boiler is continuously self-adjusting by means of a
Filter
thermostatic cartridge and a pressure regulator according to the
mains water temperature and supplies the service temperature
seleccted with the maximum flow of Hot Water. Thermostatic
cartridge

Just-in-time system for recognition of flow rate fluctuations.

The LAURA boiler, real standard of technological innovation,


incorporates a small turbine located at the mains water inlet, which
can sense the slightest variation in flow rate and send a signal to the Magnetic sensor
microprocessor for matching the boiler output to the new condition. signal
The outcome: No water temperature fluctuation is perceived and thus
no boiler self-adjustment can be expected.

Mains water metal filter

CH circuit fill point valve

Flow rate control


Mains water inlet

Hydroplus System Insulation: Expanded


Polystyrene (Porex)
In order to definitely eradicate the uncomfortable feeling of Domestic
Hot Water temperature changes when not being used in a continuous
Capacity:
way (a tap is closed, it is opened again soon after, etc.) the LAURA 1.5 litres
boiler incorporates a buffer tank, that is, a 1.5-litre fully insulated
small copper storage tank, which is capable of equalising the
temperature of Domestic Hot Water so that it can be used without
sudden frights or inconveniences which are out of place in this
century.
Outlet

Inlet

BUFFER TANK

26
Gas Fired
Wall-mounted electronic boilers
Separate steel storage cylinder for wall-mounted combi boilers.
The 60, 100 and 150 litre
Dimensions mm Connections
cylinders, versions I and I/PC,
can be mounted on the wall in Models A B D E F G H a b c d
horizontal position with the hot 60-I and I/PC 749 480 - 210 145 94 31 3/4" 3/4" 1" 1"
water connections on the left 100-I and I/PC 1.154 480 - 205 145 94 31 3/4" 3/4" 1" 1"
(Figure 1) or on the right (Figure 150-I and I/PC 983 620 - 248 164 94 50 3/4" 3/4" 1" 1"
2) or vertically (Figure 3). They
can also be installed vertically,
resting on the floor.

2 1

5 3 3 1 - Domestic Hot Water outlet.


5 3
2 - Domestic Cold Water inlet
3 - Boiler flow
1 1 4 - Boiler return
5 5 - Control panel

2 4
2

4 Figura 1 4
Figura 2 Figura 3

Separate enamelled storage cylinder for wall-mounted combi boilers

Cylinders model 110 E, and 150 E have been designed for vertical wall mounting only.

B 2
b Dimensions mm Connections
Models
A B C D E a b c d
6 110E 1.155 480 440 350 117 3/4" 3/4" 1/2" 1/2"
150E 1.260 560 480 350 117 3/4" 3/4" 1/2" 1/2"
c
3
1 - Domestic cold water inlet
A

f 5 2 - Domestic hot water outlet.


C

3 - Boiler flow
d 4 4 - Boiler return
a
5 - Immersion heater port (optional)
D

1
6 - Control panel
E

ASIK solar cylinder integrated under a wall-hung combi boiler with instantaneous DHW production.
Dimensions mm Connections

Models A B H 1 2 3 4 5 6 7 8

4 ASIK 90 880 1.000 1.869 3/4" 3/4" 1/2" 3/4" 1/2" 3/4" 3/4" 1/2"
734

ASIK 120 998 1.118 1.987 3/4" 3/4" 1/2" 3/4" 1/2" 3/4" 3/4" 1/2"
3 ASIK 150 1.116 1.236 2.105 3/4" 3/4" 1/2" 3/4" 1/2" 3/4" 3/4" 1/2"
5
2
6 1- Solar flow
1
7 2- Heating return
255
H

3- Mains water inlet


4- Gas inlet
50

5- DHW outlet
8
6- Heating flow
7- Solar return
8- DHW recirculation
A

Wall-hung boiler not fitted with an ASIK.

42
Gas Fired
Wall-mounted electronic boilers
Fittings for room-sealed and forced-draught air supply
FLUE KITS Ø 60/100
VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (**)
140040030 D D
Horizontal Concentric Flue Kit 140040162 D D D D D
140040191 D D
140040034 X X
Ver tical Concentric Flue Kit
140040184 X X X
140040061 X X
Vertical/Horizontal Concentric Flue Kit
140040259 X X
Ver tical/Horizontal Concentric
140040161 X X
Rear Flue Kit
FLUE KITS Ø 80/125
VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (**)
Horizontal Concentric Flue Kit 140040165 X X
140040084 X X
Ver tical/Horizontal Flue Kit 140040185 X X X
140040190 D
140040059 X X
Ver tical Concentric Flue 140040164 X X
Terminal Kit 140040186 X X X
140040189 X X X

FLUE KITS Ø 110/160


VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (***)
Ver tical/Horizontal Flue Kit 140040234 D
Ver tical Concentric Flue
140040236 X
Terminal Kit
FLUE KITS Ø 80
VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (**)
140040044 D D
Ver tical/Horizontal Flue Kit
140040228 X
140040039 X X
140040258 X X
Standard Twin-pipe Flue Kit 140040187 X X X
140040192 X X
140040193 X
Horizontal Flue Kit 140040229 X
140040166 X
B22 Kit
140040167 X

FLUE KITS Ø 110


VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (***)
Standard Twin-pipe Flue Kit 140040235 X

FLUE KITS Ø 125


VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (**)
Flue Kit for 1st and 2nd
140040195 X
cascaded boiler
Flue Kit for 3rd or more
140040196 X
cascaded boilers
Plastic Flue Connector with 140040194 X
Shutter for cascade boilers
FLUE KITS Ø 160
VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (**)/(***)
Flue Kit for 1st and 2nd
140040243 X
cascaded boiler
Flue Kit for 3rd or more
140040245 X
cascaded boilers
Plastic Flue Connector with 140040247 / X
Shutter for cascade boilers
FLUE KITS Ø 200
VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (***)
Flue Kit for 1st and 2nd
140040244 X
cascaded boiler
Flue Kit for 3rd or more
140040246 X
cascaded boilers
Plastic Flue Connector with
Shutter for cascade boilers 140040247 X

(*) = BIOS 24 F, BIOS 24/28 F, BIOS 28/33 F


(**) = BIOS 45 F, BIOS 65 F
(***) = BIOS 85 F, BIOS 100 F
D = Kit compatible with the boiler in question and supplied as standard.

43
Gas Fired
Wall-mounted electronic boilers
Fittings for room-sealed and forced-draught air supply
ACCESSORIES Ø 60/100
VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (**)
140040081 X X X X X X X
Flue extension 1m
140040171 X X
Flue extension 0.5m 140040123 X X X X X X X
140040082 X X X X X X X
90° Flue bend
140040174 X X
140040083 X X X X X X X
45° Flue bend
140040177 X X
Flue socket, female-female 140040088 X X X X X X X

ACCESSORIES Ø 80/125
VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (**)
140040087 X X X X X X X
Flue extension 1m
140040172 X X X
Flue extension 0.5m 140040124 X X X X X X X
140040085 X X X X X X X
90° Flue bend
140040175 X X X
140040086 X X X X X X X
45° Flue bend
140040178 X X X
Flue socket, female-female 140040090 X X X X X X X
Concentric adaptor 60/100 to 80/125 140040230 X X X X X X X

ACCESSORIES Ø 110/160
VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (***)
Flue extension 1m 140040237 X
90° Flue bend 140040238 X
45° Flue bend 140040239 X

ACCESSORIES Ø 80
VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (**)
140040042 X X X X X X X
Flue extension 1m
140040173 X X X
Flue extension 0.5m 140040122 X X X X X X X
140040040 X X X X X X X
90° Flue bend
140040176 X X X
140040041 X X X X X X X
45° Flue bend
140040179 X X X
Flue socket, female-female 140040089 X X X X X X X
90º bend with condensate
140040219 X X X X X X X
drain point
Roof terminal 140040218 X X X X X X X
Condensate drain point Ø80 140040260 X X X X X X X

ACCESSORIES Ø 110
VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (***)
Flue extension 1m 140040240 X
87° Flue bend 140040241 X
45° Flue bend 140040242 X

ACCESSORIES Ø 125
VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (**)
Flue extension 1m 140040199 X
87° Flue bend 140040198 X
45° Flue bend 140040197 X

ACCESSORIES Ø 160
VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (**)/(***)
Flue extension 1m 140040250 X
87° Flue bend 140040248 X

ACCESSORIES Ø 200
VEGA BIOS D BIOS R
LAURA ALTAIS NORA/SARA VICTORIA DEIMOS NOVADENS NOVANOX
PLUS (*) (***)
Flue extension 1m 140040251 X
87° Flue bend 140040249 X

(*) = BIOS 24 F, BIOS 24/28 F, BIOS 28/33 F


(**) = BIOS 45 F, BIOS 65 F
(***) = BIOS 85 F, BIOS 100 F

44
Gas Fired
Wall-mounted electronic boilers
Fittings for room-sealed and forced-draught air supply
Flue Kits Ø 60/100

Code: 140040030 Code: 140040162 Code: 140040191

Code: 140040061 Code: 140040161 Code: 140040259 Code: 140040034 Code: 140040184

Flue Kits Ø 80/125

Code: 140040165 Code: 140040190 Code: 140040084 Code: 140040185

Code: 140040059 Code: 140040164 Code: 140040186 Code: 140040189

Flue Kits Ø 110/160 Flue Kits Ø 110

Code:
Code: 140040234 140040236 Code: 140040235

Flue Kits Ø 80

Code: 140040044 Code: 140040167 Code: 140040039 Code: 140040258 Code: 140040229

Code: 140040187 Code: 140040192 Code: 140040193 Code: 140040166 Code: 140040228

Flue Kits Ø 125, 160 y 200

Code: 140040195 (Ø 125) Code: 140040196 (Ø 125)


140040243 (Ø 160) Code: 140040245 (Ø 160) Code:
140040244 (Ø 200) 140040247 140040246 (Ø 200) 140040194

45
Gas Fired
Wall-mounted electronic boilers
Fittings for room-sealed and forced-draught air supply
Accessories Ø 60/100

Code: 140040081 Code: 140040171 Code: 140040123

Code: Code: Code: Code: Code:


140040082 140040174 140040083 140040177 140040088

Accessories Ø 80/125 Accessories Ø 110/160

Code: 140040087 Code: 140040172 Code: 140040124 Code: 140040237

Code: Code: Code: Code: Code: Code: Code: Code:


140040085 140040175 140040086 140040178 140040090 140040230 140040238 140040239

Accessories Ø 80

Code: 140040042 Code: 140040122 Code: 140040173

Code: Code: Code: Code: Code: Code: Code: Code:


140040040 140040176 140040041 140040179 140040089 140040219 140040218 140040260

Accessories Ø 110 Accessories Ø 125

Code: 140040240 Code: Code: Code: 140040199 Code: Code:


140040241 140040242 140040198 140040197

Accessories Ø 160 Accessories Ø 200

Code: 140040250 Code: Code: 140040251 Code:


140040248 140040249

Installation Accessories
UNIVERSAL REPLACEMENT KIT UNIVERSAL REPLACEMENT KIT (with no gas pipe)

Universal replacement kit to Universal replacement kit


make installation of our to make installation of our
wall-mounted boilers wall-mounted boilers
easier in place of other easier in place of other
models and/or makes. models and/or makes.
Code: 140040130 Code: 140040135

46