You are on page 1of 148

FIBER OPTIC

CABLE
сatalogue 2018
1
2
Smart Plant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Production. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Quality philosophy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Best Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Best Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Friendly team. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
OPGW/Ground Wire. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Fire-Resistant Optic Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Sensor Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Outdoor Fiber Optic Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
InTube. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
InDuct. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
InGround . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
InWater. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
InAir Figure 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
InAir ADSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Indoor Fiber Optic Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
FTTH-Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
FTTH-Subscribers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
HTTP-Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Semi Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Knowledge Base. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Types and Parameters of Optical Fiber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Color Identification Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Transportation. Maintenance. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Drum Size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Drum Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Contacts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
#1
10 YEARS

8 850 000
kilometers of fibers

340 000
kilometers of cable
in the volume of fiber optic cable manufacturing
in Russia and CIS (in 2013–2015 and 2017), and
volume of processing optical fiber

95 000
drums
in Russia and CIS (2012–2017)

57 000
tons of fiber optic cable

OVER 2017

1 350 000
kilometers of fibers

60 000
kilometers of cable

19 000
drums

8 500
tons of fiber optic cable

4
SMART PLANT
Dear colleagues! DESIGN: Incab .Pro is a division of Incab Ltd.
During the 9 years of operation a lot has been said dedicated to integrated design of optical
about Incab achievements and advantages. The communication lines in accordance with the
main message we would like to convey now is that highest industry standards and regulations.
we continue to follow our ‘Smart Plant’ strategy.
That is the new bar we set for ourselves. SUPPORT: at our website www.incab.co
you may find a knowledge base containing
PRODUCTION: we are constantly expanding our up-to- date information on optical communication
product range, which now includes the following lines. We also provide online selection of cables
new cable types: fire-resistant and fireproof and accessories: clamps, connectors, vibration
cables, sensor cables and special fiber optic cables dampers, fixtures and other auxiliaries.
for the aerospace and defense industries. When choosing Incab, you are sure to get reliable
solutions tailored to your specific needs and
SUPPLIES: we cooperate with leading designed with the best of our experience and zest.
manufacturers of materials and equipment.
We have experience in cable supply to big
telecommunications service providers. Incab. Working For You.

Yours for continued success,


Alexander Smilgevich, CEO

5
80
1. PRODUCTION
Incab Ltd. has the widest product range

+ We design
cables based
on our
Customers'
specific technical
requirements

public fiber optic designs

7 classified
designs 10 designs currently
in development
6
CABLE FOR ALL
APPLICATIONS
Outdoor Fiber Optic Cable

InTube InDuct InGround InWater InAir Figure 8 InAir ADSS

Indoor Fiber
Optic Cable New products

FTTH-Distribution FTTH-Subscribers HTTP-Drop OPGW/Ground Fire-Resistant Sensor Cable


Wire

7
2. SUPPLIES
Incab supplies optic cable directly or via
construction companies and integrators to the
largest Eurasian Operators of Telecommunication
Services , Power Grid Companies, Oil,
Gas & Petrochemicals Industry’s Companies.

Incab also has experience of deliveries


to Europe, Asia and America.

4200 km
to Asia

9500 to Europe
km

8
9
3. DESIGN
Design is another core competence of Incab which Incab.Pro has all required work access certificates
developed based on our experience in production and permits.
and supplies of optical fiber cables.
Our approach to designing telecommunication
Incab.Pro is a subsidiary of Incab involved in lines helps to improve their reliability and reduce
design and development. This is a team of risk of accident.
professionals whose ambitious target is to create
a culture of designing optic fiber lines based on
the most effective technologies and solution.

«We design modern telecommunication lines to provide for


smooth long-term operation».

Dmitry Gibert,
Incab.Pro General Manager,
Technical Director of Incab Plant

10
Cooperation in the field
of designing optical
communication systems

SELECTING OPTICAL CABLE ASSISTANCE IN PROJECT CALCULATIONS


with the best parameters to suit • calculating the electrical field of overhead lines and line crossings,
the technical specifications of the project • determining the best suspension point for ADSS cable
• calculating tension and sag of OPGW/ADSS cable
• calculating additional stress on the tower from ADSS cable
DEVELOPING TECHNICAL SOLUTIONS • calculating thermal effect of short circuit currents on OPGW

PROJECT ANALYSIS
SELECTING ALL THE ACCESSORIES assessment of the technical solutions chosen for your project,
and fittings creating optimization proposals

Contact us at:
mail@incab.pro

11
4. SUPPORT
Knowledge Base

Cable selection Accessories selection: Transportation, Winding cable on the


spline closures, fittings, storage and installation reel, placing reels on
clamps, connectors, guidelines the truck
vibration dampers,
fixtures

Some materials from the Knowledge Base are available in this catalog, pages 119 to 130.

12
Free Engineering Advice:

Describe your challenge and send Online support: incab.co.


an e-mail to: support@incab.ru We will be delighted to offer
our solution

Free Training
Incab experts provide onsite training seminars of the following topics:

— optic fiber cable: design and production trends;



— features of the optical fiber, recent developments;

— optic fiber cable: installation and operation guidelines.

Send a request to order a free onsite training seminar for your employees: export@incab.ru

13
Quality philosophy
“Quality means doing it right when no one is looking”. Henry Ford

PHILOSOPHY — software to select the right type of fiber optic cable,


Quality is in the heart of everything we do. Our quality policy the right size of the drums, and the optimal arrangement
is implemented through: of drums on trucks and in containers;
— 100% step-by-step quality control; — software for aerial cable calculations;
— best in the industry Test Center; — calculation of power line electromagnetic fields;
— high-quality materials; — continuous customer feedback.
— quality management system certified according to TÜV
International Certification;
— declarations for all cable types manufactured by Incab;
— reference letters and certificates provided by federal
companies and control authorities;

14
STEP-BY-STEP QUALITY CONTROL We use advanced high-precision control and measurement
Quality Control employees carry out stringent control at all stages equipment:
of the manufacturing process, including: : — МТР 9000 Optical Reflectometer;
— incoming control of materials; — Yokogawa AQ7260 Optical Time Domain Reflectometer;

— measuring parameters of each optical fiber; — Ando AQ6319 Spectrum Analyzer;
— control of fiber length in the tubes; — PK2500 Optical Spectrum Analyzer;

— verification of compliance with the design requirements; — PK2400 Fiber Geometry System;

— checking resistance and tightness of the jacket — EXFO FTB-400 Universal Test System;
(for armored cables); — Zumbach Geometry Testers.

— control of marking and packaging.
All measurements are recorded and analyzed for further quality
Our line operators control the dimensions of the products improvement.
throughout the manufacturing process.

15
FEEDBACK
TEST CENTER
In order to meet the world's highest quality standards, we
Our Test Center is equipped according to the latest industry
continuously monitor feedback from our customers.
For comments
standards to conduct type approval and periodic mechanical
and suggestions, please, contact Dmitry Gibert , Technical
and environmental resistance tests per IEC 60794-1-2 (water
Director— gibert@incab.ru.
penetration, temperature cycling, high humidity, vibration,
stretching, bending, torsion, crush, compression).

CERTIFICATES
All HFFR cables have the relevant fire safety certificates.
Our
Quality Management System is certified to ISO 9001:2008 and TÜV
Thüringen.

16
Best Materials
To produce Incab cables, we use the most advanced materials OTHER MATERIALS
available in the market. — color ink (DSM Desotech, Herkula);
— water-blocking gel (Unigel, Itcogel);
CORNING® SMF-28® ULTRA — PBT (BASF, DuPont);

Advantages:
 — fiberglass rods (Indore, AKSH);
— Increased equipment efficiency, 10% less fiber attenuation.
 — steel zinc-coated wire (Orlovskie Metizy, Severstal Metizy);
— Significantly improved reliability and resistance to installation — steel zinc-coated rope (Severstal Metizy);

damages. Ten times higher bend-resistance compared to standard — aramid yarn (Kolon, Kevlar, Twaron);

single-mode fibers. — polyester binder yarn (Roblon, Fiberline, GOTEX);
— steel laminated tape (ShangHai WangXun, LongVision);

— halogen-free materials (AlphaGary, LamPlast);

BOREALIS BIMODAL POLYETHYLENE — fiberglass yarns (Roblon, FiberLine, Gotex);

Advantages: — water-blocking tape (Lanton, Shenyang Tianrong,
— Low shrinkage and high resistance to temperature changes. Lantor, DEUK YOUNG);
— Installation temperatures down to -30 C. — water-blocking yarn (Lantor, FiberLine, Roblon, Gotex, FiberLine)

— steel tape (DMA INOX);

— aluminum (RusAl).

17
Best Equipment
CAPACITY: 6000 cable kms per month.


PRODUCTION EQUIPMENT BY: Maillefer, Medek&Schorner, Nexans, Photonium, Compotec and other manufacturers.

Optic Fiber Cable:
 OPGW:



— coloring lines; — production line for manufacturing stainless steel micro
— loose tube lines;
 tubes containing optical fibers;

— stranding lines;
 — pre-cleaning and rewinding line;

— sheathing line with aramid servers; — cladding line;

— steel wire armoring machine. — drawing line;

— stranding line (planetary type stranding machine).

18
19
Friendly team

20
21
OPGW/Ground Wire

OPGW Stainless OPGW OPGW Ground Wire


Steel Tube Stranded Aluminium-clad (Nonrusting)
page 22 Stainless Steel Stainless Steel page 25
Tube Tube
page 23 page 24

23
OPGW/Ground Wire
APPLICATION:
OPGW/Ground Wire

Protection of power lines from Construction of optical


lightning overvoltage communication systems

OPGW Stainless Steel Tube C ER T IF


IED

Up to 48 fibers Aluminum Clad Steel wires


4 3 2 1 in a tube are rustproof

Aluminum alloy wires shield the


high-voltage conductors from
CONSTRUCTION: lightning strikes
1. Optical fiber.
2. Stainless steel tube filled with water-swellable gel.
3. Stranded wires (Aluminum Clad Steel wires and /or aluminum alloy wires).
4. Stranded wires (Aluminum Clad Steel wires and /or aluminum alloy wires).

Features
OPGW Stainless Steel Tube
Crush — 1 kN/cm
Fiber count 4…48
Cable weight, kg/km 200…1230
Cable diameter, mm 8…18
Rated tensile strength 25…210
Tensile strength, kN 15…125
Elasticity modulus (final), kN/mm² 70…160

24
Thermal resistance (initial temperature 25 °C, final temperature 200 °C), kA²s 5…300
Short-circuit current for 1s, kA 3…20
We design cables based on our Customers' specific technical requirements.
Please, contact us for a cable designed to your exact specifications.

OPGW/Ground Wire
OPGW Stranded Stainless C ER T IF
IED

Steel Tube
Up to 288 fibers Aluminum Clad Steel wires
4 are rustproof
5 2 1
3

Aluminum alloy wires shield the


high-voltage conductors from
lightning strikes
CONSTRUCTION:
1. Central strength member (Aluminum 4. Stranded wires (Aluminum Clad Steel
Clad Steel wires or aluminum alloy wires). wires and /or aluminum alloy wires).
2. Optical fiber. 5. Stranded wires (Aluminum Clad Steel
3. Stainless steel tube filled wires and /or aluminum alloy wires).
with water-swellable gel.

Features
OPGW Stranded Stainless Steel Tube
Crush — 1 kN/cm
Fiber count 4…288
Cable weight, kg/km 330…1530
Cable diameter, mm 11.0…21.0
Rated tensile strength 47…275
Tensile strength 28…165
Elasticity modulus (final), kN/mm² 70…160
Thermal resistance (initial temperature 25 °C, final temperature 200 °C), kA²s 5…550
Short-circuit current for 1 s, kA 4…30

We design cables based on our Customers' specific technical requirements. Please, contact us for a cable designed to your exact specifications.

25
NEW
OPGW Aluminium-clad
Stainless Steel Tube
OPGW/Ground Wire

100% corrosion-resistant:
Up to 48 fibers
ACS wires and stainless
in a tube
steel tube. Suitable for
3 2 1
areas with highly
corrosive environments.

Aluminum alloy wires shield


the high-voltage conductors
CONSTRUCTION: from lightning strikes
1. Optic fiber.
2. Aluminium-clad stainless steel tube filled with water-swellable gel.
3. Stranded wires (Aluminum Clad Steel wires and /or aluminum alloy wires).

Features
OPGW Aluminium-сlad Stainless Steel Tube
Crush — 1.5 kN/cm
Fiber count 4…48
Cable weight, kg/km 200…1230
Cable diameter, mm 9…18
Rated tensile strength 25…210
Tensile strength, kN 15…125
Elasticity modulus (final), kN/mm² 70…160
Thermal resistance (initial temperature 25 °C, final temperature 200 °C), kA²s 5…300
Short-circuit current for 1s, kA 3…20

We design cables based on our Customers' specific technical requirements.


Please, contact us for a cable designed to your exact specifications.

26
Ground Wire (Enhanced
Corrosion-resistant Groundwire)

OPGW/Ground Wire
Mandatory element of 35 kV
power lines approaching Aluminum alloy wires shield
3 2 1 electrical substations and the high-voltage conductors
of all 110 kV power lines from lightning strikes

CONSTRUCTION: Aluminum Clad Steel wires


are rustproof
1. Central strength member (Aluminum Clad Steel wire).
2. Stranded wires (Aluminum Clad Steel wires and /or aluminum alloy wires).
3. Stranded wires (Aluminum Clad Steel wires and /or aluminum alloy wires).

Features
Ground Wire (Nonrusting)

Outer diameter, mm 7.6…22.6


Cable weight, kg/km 230…1990
Rated tensile strength 45.4…383.5
Tensile strength 28.4…240.3
Average operating load, kN 13.6…115.0
Sectional area of steel elements, mm2 35.0…298.5
Sectional area of aluminum elements, mm2 0.0
Total sectional area, mm2 35.0…298.5
DC resistance at 20 °C, Ohm/km 2.472…0.290
Thermal resistance to short-circuit current, kA2s 8.7…636.7
Coefficient of linear thermal expansion, 10-6 1/K 12.6
Elasticity modulus (final), kN/mm² 157.8…155.5
Modulus of elasticity (initial, installation), kN/mm2 139.8…137.7
Modulus of elasticity (drawing), kN/mm2 123.1…121.3

27
High Temperature Wire
APPLICATION:
OPGW/Ground Wire

High temperature wire TACSR/ACS 521-A20SA is used for


aerial suspension on 35 kV power lines and above

Effective solution for large


Aerial suspension on 35 kV cable spans, including
1 power lines and above cross-river installation

CONSTRUCTION:
1. Aluminium-clad steel wire or aluminium-clad steel wire and heat-resistant aluminium alloy wire.

Features
High Temperature Wire

Cable diameter, mm 29.7


Cable weight, kg/km 4383
Rated tensile strength, kN 666
Elasticity modulus (final), kN/mm2 155

We design cables based on our Customers' specific technical requirements.


Please, contact us for a cable designed to your exact specifications.

28
Optical Phase Conductor

OPGW/Ground Wire
APPLICATION:

Designed to carry electricity and optical signal for the suspension as phase conductor on 35 kV power
lines and above. Effective solution to provide redundancy in harsh conditions, such as long cable spans,
crossings of cable spans, power lines with previously installed OPGW and ADSS and others.

Up to 48 optical fibers Aluminum-clad steel wire


in a tube eliminates corrosion
4 4 3 3 2 1

Aluminum alloy wire effectively Effective solution to provide


removes heat from a lightning redundancy in harsh
stroke point and increases short- conditions, such as long
circuit current resistance cable spans, crossings of
cable spans, power lines with
previously installed OPGW
CONSTRUCTION: and ADSS and others.
1. Optical fiber.
2. Stainless steel tube.
3. Aluminium-clad steel wire.
4. Aluminium-clad steel wire.

Features
Optical Phase Conductor
Crush — 1 kN/cm
Fiber Count 36 12 48
Cable diameter 22.3 24.8 22.6
Cable weight 992 1217 996
Elasticity modulus (final) 79 80 79
Rated tensile strength 127 161 127

29
Operation parameters OPGW/Ground Wire
Operation temperature range -60°С…+80°С
Installation temperature range -30°С…+50°С
OPGW/Ground Wire

Transportation and storage temperature range -60°С…+70°С


Min bending radius 20xcable diameter
Warranty lifetime as specified in the supply agreement, min 2 years
We design cables based on our Customers' specific technical Requirements. Please, contact us for a cable designed to your exact specifications.

30
31
32
Fire-Resistant
Optic Cable

Fire–Resistant
стр.28

33
Fire-Resistant
NEW

Optic Cable
APPLICATION:
Fire-Resistant

for fire protection and another systems which


are needed to work under fire conditions

tower buildings large data centers

for child care centers, educational institutions,


board and care facilities, hospitals, dormitory blocks

security monitoring subway


for high occupancy buildings

for buildings and closed installations


industrial and mining defense sector
companies

for open cable structures

entertainment centers atomic energetics for individual installation in cable structures


and working spaces

refineries and petrochemical sport-facilities


industry infrastructure
and educational institutions

34
Fire safety levels

Fire-Resistant
Fire resistant
fire-
resistant

Every next step includes previous steps


low loxicity Fireproof cable / Level 3

halogen free

low smoke Fireproof cable / Level 2


and gas emission

group cabling

single cabling Fireproof cable / Level 1

35
Fireproof cable / Fireproof cable /
LEVEL 1 LEVEL 2
Single laying Group laying, low smoke and gas emission, halogen-free
InDuct Standard InTube Standard InGround Standard Reinforced
InDuct

InTube
(Multi-Tube Single Armor Double Jacket Cable) (Multi-Tube Single Jacket Cable) (Multi-Tube Double Armor Double Jacket Cable)

InGround
Fire-Resistant

InDuct Standard InGround Standard Reinforced Dielectric


InDuct Light

InDuct
(Multi-Tube Single Armor Double Jacket Cable) (Multi-Tube Double Armor Double Jacket Cable)
(Multi-Tube Single Armor Single Jacket Cable)

InDuct Superlight InDuct Light InGround Superlight


(Uni-Tube Single Armor Single Jacket Cable, (Multi-Tube Single Armor Single Jacket Cable) (Uni-Tube Single Armor Single Jacket Cable)
Corrugated Steel Tape)

InDuct Superlight InGroung Superlight Dielectric


(Uni-Tube Single Armor Single Jacket Cable, (Uni-Tube Single Armor Single Jacket Cable)
Corrugated Steel Tape)

InGround Standard
(Multi-Tube Single Armor Double Jacket Cable)
InGround

InGound Stainless Steel Tube


(Uni-Tube Single Armor Single Jacket Cable)
InDuct Stainless Steel Tube
(Uni-Tube, Single Jacket Cable)

InGround Standard Wetland


InGround Superlight InGround Standard (Multi-Tube Single Armor Double Jacket
InGround

(Uni-Tube Single Armor Single Jacket Cable) (Multi-Tube Single Armor Double Jacket Cable) Aluminum and Polymer Tape Cable)

InGround Standard Dielectric


(Multi-Tube Single Armor Double Jacket Cable)

36
InAir ADSS Standard Aramid Tight-Buffered Riser Tight-Buffered Simplex
InAir ADSS

FTTH-Distribution

FTTH-Subscribers
(Multi-Tube Aramid Double Jacket Cable)

Fire-Resistant
Tight-Buffered Duplex
Riser with Micro Tubes
InAir ADSS Standard Fiberglass
(Multi-Tube Fiberglass Double Jacket Cable)

FTTH «Butterfly»

Tight-Buffered Distribution
InAir ADSS Light Aramid
(Multi-Tube Aramid Single Jacket Cable)

Flat Type Drop Reinforced


Distribution with Micro Tubes

HTTP–Drop
InAir ADSS Light Fiberglass
(Multi-Tube Fiberglass Single Jacket Cable)

Round Type Drop


Distribution «Butterfly» (up to 8 fibers)

Round Type Drop (8 Fiber Count)

37
Fireproof cable /
LEVEL 3
Low toxicity.
Tight-Buffered Riser Tight-Buffered Simplex
FTTH-Distribution

FTTH-Subscribers
Fire-Resistant

Tight-Buffered Duplex
Riser with Micro Tubes

FTTH «Butterfly»

Tight-Buffered Distribution

Distribution with Micro Tubes Round Type Drop


HTTP– Drop

Round Type Drop (8 Fiber Count)


Distribution «Butterfly» (up to 8 fibers)

38
FIRE-RESISTANT

Universal Fire-Resistant
Fire–Resistant

Fire-Resistant
Indoor Fire-Resistant

Outdoor Fire-Resistant

Advantages
The first in Russia Incab Fire-Resistant Optic cable

F Cl Br I
flame retardant remain operative low toxicity of combustion low smoke halogen-free
in group laying exposed to fire during products
at least 180 minutes

39
NEW
Universal Fire-Resistant
Remains functional under Holds physical impact and
influence of flame during water supplying for fire
4 3 2 1 180 minutes fighting
Fire-Resistant

Minimum High resistance to crushing


combustible (more than 1 kN/cm). It
CONSTRUCTION: materials remains even after influence
1. Optical fiber. of flame
2. Stainless steel tube.
3. Armor of steel wires. Small size – thin, Suitable for all
4. Halogen-free jacket. light, economical applications

Up to 48 fibers Diameter
in a tube less than 10 mm

Features
Universal Fire-Resistant

Allowable tensile strength — 4 kN


Crush — 1.4 kN/cm
Fiber count up to 24 up to 36 up to 48
Cable diameter, mm 8.8 9.6 9.9
Cable weight, kg/km 156 169.7 180.7
Min bending radius, mm 132 138 142.5

Allowable tensile strength —10 kN


Crush — 1.4 kN/cm
Fiber count up to 24 up to 36 up to 48
Cable diameter, mm 9.6 9.6 9.9
Cable weight, kg/km 198.3 197.8 211.5
Min bending radius, mm 144.0 144.0 148.5

40
NEW
Indoor Fire-Resistant
Remains functional under All-dielectric
influence of flame during construction
180 minutes

7 6 5 4 3 2 1

Fire-Resistant
Easy to dress
and install Up to 48 fibers

UV resistance

CONSTRUCTION:
1. Central strength member 5. Mica glass tape.
(fiberglass reinforced plastic). 6. Fiberglass yarns.
2. Optical fiber. 7. Halogen-free jacket.
3. Tight-buffer.
4. Inner jacket made of halogen-free
flame-retardant polymer compound.

Features
Indoor Fire-Resistant

Allowable tensile strength — 1.1 – 1.9 kN


Crush — 200 N/cm
Fiber count 2-6 8 12 16-18 24
Allowable tensile strength, kN 1.1 1.2 1.9 1.1 1.4
Cable diameter, mm 10.7 11.2 12.2 12.5 13.2
Cable weight, kg/km 147.4 161.7 192.2 194.5 218.4
Min bending radius, mm 107 112 122 125 132

41
Outdoor Fire-Resistant
NEW

Fire-resistant cable remains Armor is a perfect


functional under influence protection from
3 of flame during 180 minutes rodents
Fire-Resistant

7 6 5 2 1
4

Up to 288 fibers Easy to install

CONSTRUCTION:
1. Central strength member 4. Water-blocking yarns.
(fiberglass reinforced plastic). 5. Inner jacket made of halogen-free
2. Optical fiber. flame-retardant polymer compound.
3. PBT loose tubes filled with 6. Corrugated steel tape armor.
water-swellable gel. 7. Halogen-free jacket.

Features
Outdoor Fire-Resistant

Allowable tensile strength — 2.7 kN


Crush — from 0.3 kN/cm
up to 48 up to 72 up to 96 up to 96 up to 144 up to 144 up to 144 up to 192
Fiber count
(6x8) (6x12) (6x16) (8x12) (6x24) (9x16) (12x12) (8x24)
Number of optical modules 6 6 6 8 6 9 12 8
Number of fibers in the module 8 12 16 12 24 16 12 24
Cable diameter, mm 12.6 12.9 14.0 14.7 14.8 16.2 17.5 16.6
Cable weight, kg/km 184.2 188.6 218.2 239.3 240.3 278.6 326.8 285.1
Min bending radius, mm 189.0 189.0 210.0 220.5 222.0 243.0 262.5 249.0

42
Operation Parameters Fire-Resistant
Operation temperature range* -40°С…+60°С
Installation temperature range -10°С…+50°С
Transportation and storage temperature range -50°С…+50°С
Min bending radius 10x cable diameter

Fire-Resistant
Life time 25 years

*Operation temperature range can be increased on request.

We design cables based on our Customers' specific technical requirements.


Please, contact us for a cable designed to your exact specifications.

43
44
Sensor Cable

Sensor Cable
page 40

45
Sensor Cable
We produce Sensor Cable
for different applications
Sensor Cable

APPLICATION:

Oil and gas wells Leakage monitoring for pipelines High-voltage cables
and transmission lines

Technological processes Perimeter guarding Fire alarm systems


for long-distance facilities

Temperature monitoring Monitoring technical condition City infrastructure and public


for ground wires of engineering facilities utility objects

We have developed several types of logging cables currently We are ready to provide information concerning the existing
used in oil and gas wells. We continuously develop new cable cable types as well as develop a solution to meet your specific
designs and constructions. needs. Contact us: sensor@incab.ru.

46
A new product developed by Incab in cooperation with Inversion Sensor Ltd. (Incab partner in the Photonics cluster).

DESCRIPTION:
Optical fiber real time temperature monitoring system for long-distance industrial
and infrastructure facilities.

CONSTRUCTION:
1. ASTRO E540/560 from Inversion Sensor.
Receives and processes the data about temperature advance along the sensor
cable.

Sensor Cable
2. Incab fiber optic sensing cable. Designed specifically for temperature sensing,
sensor cable is approved and excessively resistant to temperature changes.
Incab will customize the cable to ensure it provides the best product at the best
value to ensure your success.

Features of ASTRO E540/E560


E540 E560
Temperature sensing range, °С -55 ... +300 -55 ... +300
Precision, °С 0.5 0.5
Sensing time, sec from 10 from 10
Precision of ranging, m 1 0.5
Length of sensing member/cable, km up to 8 up to 8
Radiation wavelength, nm/fiber type 1550/ММ 1550/ММ
Optical connector FC/UPC FC/UPC
Operation temperature range, °С -10 ... +40 -10 ... +40
Operation environment, humidity, % 0 … 90 without reflux 0 … 90 without reflux
AC source voltage, V 220 220
Rated input, Vt 200 200
Dimension, mm 500 × 450 × 130 500 × 450 × 130
Weight, kg 12 12

47
Outdoor Fiber
Optic Cable

InTube InDuct InGround InWater InAir InAir ADSS


page 44 page 47 page 54 page 70 Figure 8 page 84
page 74

49
InTube
APPLICATION:

Applied in duct, trays, blocks, tunnels, Suitable for aerial installation: power
Designed for duct installations collecting channels, with no risk of rodents’ lines, lamp posts, railway overhead
attacks system

InTube Standard
(Multi-Tube Single Jacket Cable)
InTube

All-dielectric
construction Easy to install
4
6 5 3 2 4 1

Reduced weight and size.


Convenient for blowing-in in tubes

CONSTRUCTION:
1. Central strength member 4. Water-blocking yarns.
(dielectric fiberglass reinforced plastic). 5. Reinforcing elements — aramid yarns.
2. Optical fiber. 6. Jacket.
3. PBT loose tube filled with water-
swellable gel.

Features
InTube Standard

Allowable tensile strength — 1.5 kN


Crush — from 0.3 kN/сm
Fiber count up to 48 up to 72 up to 96 up to 144
Cable diameter, mm 9.6 10.3 11.2 12.0

50
Cable weight, kg/km 69.5 78.6 92.1 103.8
Min Bending radius, mm 144.0 154.5 168.0 180.0

Allowable tensile strength — 2.7 kN


Crush — from 0.3 kN/сm
Fiber count up to 48 up to 72 up to 96 up to 144
Cable diameter, mm 9.8 10.4 11.2 12.0
Cable weight, kg/km 74.0 81.8 92.8 103.8
Min Bending radius, mm 147 156 168 180

InTube Standard cable may be produced in a dry version.


In dry version water-swellable gel is replaced with dry water-blocking materials.

InTube
InTube Micro
(Multi-Tube Single Jacket Cable, Reduced Size)
Blowing-in into micro Al-dielectric
tubes is material-and construction
space-efficient, it provides
high cable density
in size-limited ducts

5 4 3 2 4 1
Dry construction Reduced weight and size.
is convenient in Convenient for blowing-in
installation tubes

CONSTRUCTION:
1. Central strength member 4. Water-blocking yarns.
(dielectric fiberglass reinforced plastic). 5. Jacket.
2. Optical fiber.
3. PBT loose tube filled with water-
swellable gel.

51
Features
InTube Micro

Allowable tensile strength — 1.5 kN


Crush — from 0.1 kN/сm
Fiber count up to 72 up to 96 up to 144 Up to 216 (18x12) Up to 288 (24x12) Up to 432 (36x12)
Cable diameter, mm 6.0 6.6 7.6 8.5 9.4 15.3
Cable weight, kg/km 24.3 28.6 36.4 42.0 58 141.1
Min bending radius, mm 90.0 99.0 114.0 127.5 141.0 229.5

InTube Micro cable may be produced in a dry version.


In dry version water-swellable gel is replaced with dry water-blocking materials.
InTube

Options
All InTube cables may be produced in versions: Fireproof cable/Level 1 and Fireproof cable/Level 2 (page 30).
We design cables based on our Customers' specific technical Requirements.

Operation parameters InTube


Operation temperature -60°С (-45°С InTube Micro)…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -60°С…+70°С
Minimum bending radius 15x cable diameter
Life time 25 years
Minimum bending radius of optic fiber 3 mm (within 10 min)

* Operation temperature range can be increased on request

52
InDuct
APPLICATION:

Suitable for direct buried installation with


Applied in ducts, trays, blocks, tunnels, no exceeded mechanical exposure of the
Applied for installation on bridges and
collecting channels, with a risk of rodents’ ground
overpasses
attacks

InDuct Standard
(Multi-Tube Single Armor Double Jacket Cable)

InDuct
Proven reliable Perfect protection from
design rodents

6
8 7 4 3 2 5 1
5 Improved reliability Allowable tensile
due to inner jacketing strength up to 2.7 kN

Resistance to crushing
loads from 0.3 kN/сm

CONSTRUCTION:
1. Central strength member 5. Water-blocking yarns.
(dielectric fiberglass reinforced plastic). 6. Inner jacket.
2. Optical fiber. 7. Corrugated steel tape armor.
3. PBT loose tubes filled with 8. Jacket.
water-swellable gel.
4. Water-swellable gel.

53
Features
InDuct Standard

Allowable tensile strength — 2.7 kN*


Crush — 0.3 kN/сm
Fiber count up to 48 up to 72 up to 96 up to 144
Cable diameter, mm 12.6 12.9 14.0 14.9
Cable weight, kg/km 150.9 155.4 180.5 202.3
Min bending radius, mm 189.0 193.5 210.0 223.5

* InDuct Standard cable may be produced with Allowable tensile strength – 5 kN

InDuct Light
InDuct

(Multi-Tube Single Armor Single Jacket Cable)


The most popular Efficient design
design

Perfect protection from Reduced weight


rodents and size
8 7 6 5 4 3 2 1

Resistance to crushing Allowable tensile strength


loads from 0,3 kN/сm up to 2.7 kN

CONSTRUCTION:
Increased tightness
1. Central strength member 5. Water-swellable gel.
due to application
(dielectric fiberglass reinforced plastic). 6. Water-blocking tape. of water-blocking tape
2. Water-blocking yarns. 7. Corrugated steel tape armor.
3. Optical fiber. 8. Jacket.
4. PBT loose tubes filled with
water-swellable gel.

54
Features
InDuct Light

Allowable tensile strength — 2.7 kN


Crush — from 0.3 kN/сm
Fiber count up to 48 up to 72 up to 96 up to 144
Cable diameter, mm 11.5 12.0 12.9 13.8
Cable weight, kg/km 125.9 132.9 151.6 171.3
Min bending radius, mm 172.5 180.0 193.5 207.0

InDuct Superlight
(Uni-Tube Single Armor Single Jacket Cable, Corrugated Steel Tape)

Efficient design Perfect protection from


6 rodents, suitable for duct
installation

5 4 3 2 1
Reduced weight
Up to 24 fibers
and size

Resistance to crushing Allowable tensile


loads from 0.5 kN/сm strength up to 2.7 kN

CONSTRUCTION:
1. Optical fiber. 4. Corrugated steel tape armour.
2. PBT loose tube filled 5. Jacket.
with water-swellable gel. 6. Steel wires.
3. Water-swellable gel.

55
Features
InDuct Superlight

Allowable tensile strength — 2.7 kN


Crush — from 0.5 kN/сm
Fiber count up to 12 up to 16 up to 24
Cable diameter, mm 8.3 8.5 8.8
Cable weight, kg/km 81.8 84.0 87.3
Min bending radius, mm 124.5 127.5 132.0

InDuct Superlight
InDuct

(Multy-Tube Single Armor Jacket Cable, Corrugated Steel Tape)

Up to 48 optical fibers
Efficient design the module
7

6 5 4 3 2 1
Perfect protection from Reduced weight
rodents, suitable for duct and size
installation

Resistance to crushing Allowable tensile


loads from 0.3 kN/сm strength up to 2.7 kN
CONSTRUCTION:
1. Optical fiber. 4. Water-blocking tape.
2. PBT loose tube filled with water- 5. Corrugated steel tape armor.
swellable gel. 6. Jacket.
3. Water-swellable gel. 7. Steel wires.

56
Features
InDuct Superlight

Allowable tensile strength — 2.7 kN


Crush — from 0,3 kN/сm
Fiber count up to 24 up to 32 up to 48
Number of optical modules 3 3 3
Number of optical fibers in the module 8 2 × 12 OF + 1 × 8 OF 16
Cable diameter, mm 10.4 10.8 11.2
Cable weight, kg/km 107.3 115.3 129.7
Радиус изгиба, мм 156.0 162.0 168,0

InDuct Zinc-Coated Steel Wires

InDuct
(Uni-Tube Single Armor Single Jacket Cable, Zinc-Coated Steel Wires)

Efficient design Excellent rodent


resistance

5 4 3 2 1

100% waterproof Reduced weight


and size.

Resistance to crushing Up to 24 optical fibers


CONSTRUCTION: loads from 0.5 kN/сm the module
1. Optical fiber. 3. Water-swellable gel.
2. PBT loose tube filled with 4. Armor of zinc-coated steel wires.
water-swellable gel. 5. Jacket.
Allowable tensile strength
up to 2.7 kN

57
Features
InDuct Zinc-Coated Steel Wires

Allowable tensile strength — 2.7 kN


Crush — from 0.5 kN/сm
Fiber count up to 16 up to 24
Cable diameter, mm 8.0 8.3
Cable weight, kg/km 90.0 96.9
Min bending radius, mm 120.0 124.5

InDuct Stainless Steel Tube


InDuct

(Uni-Tube Single Jacket Cable)

The smallest
100% waterproof
diameter

3 2 1
Maximum resistance to
Allowable tensile
crushing loads
strength up to 1.5 kN
from 0.7 kN/сm

CONSTRUCTION:
1. Optical fiber. Excellent rodent
2. Stainless steel tube filled with water-swellable gel. resistance
3. Jacket.

58
Features
InDuct Stainless Steel Tube

Allowable tensile strength — 1.5 kN


Crush — 0.7 kN/сm
Fiber count up to 24 up to 36 up to 48
Cable diameter, mm 6.8 7.2 7.5
Cable weight, kg/km 47.0 52.8 56.2
Min bending radius, mm 102.0 108.0 112.5

The InDuct Stainless Steel Tube Cable may be produced in a dry version.
In dry version water-swellable gel is replaced with dry water-blocking materials.

InDuct Dielectric

InDuct
(Multi-Tube Fiberglass Double Jacket Cable)

All-dielectric Fiberglass yarns prevent


construction damage by rodents

7 6 5 4 3 2 1

Resistance to crushing Permissible tensile


loads from 0.3 kN/cm load – 2.7 kN

Inner jacket ensures


CONSTRUCTION: higher reliability
1. Central strength member — 5. Inner jacket.
fiberglass dielectric rod. 6. Reinforcement element —
2. Optical fiber. fiberglass yarns.
3. PBT optical tubes filled with 7. Polymer jacketing.
water-blocking gel.
4. Inter-tube water-blocking gel.

59
Features
InDuct Dielectric

Allowable tensile strength — 2.7 kN


Crush — from 0.3 kN/сm
Fiber count Up to 16 Up to 32 Up to 48 Up to 72
Cable diameter 10.4 10.8 11.0 11.9
Cable weight 84.3 89.3 92.8 109.3
Min bending radius 156 162 165 179

Operation parameters InDuct


InDuct

Operation temperature range* -50°С…+70°С (-60°С...+70°С InDuct Stainless Steel Tube)


Installation temperature range -30°С…+50°С
Transportation and storage temperature range -60°С…+70°С
Min bending radius 15x cable diameter
Life time 25 years

* Operation temperature range can be increased on request

Options
All InDuct cables may be produced in versions: Fireproof cable/Level 1 and Fireproof cable/Level 2 (page 30).
We design cables based on our Customers' specific technical Requirements.

60
InGround
Suitable for aerial installation
Applied in harsh environments with between buildings and constructions
potential mechanical impact: in grounds of (however, its bigger weight
Applied in ducts, trays, blocks, tunnels, and
all the groups, bogs, unnavigable rivers and diameter compared to self-
collecting channels
supporting cables should be taken
into consideration)

InGround Standard
(Multi-Tube Single Armor Double Jacket Cable)

InGround
The most popular Reliable protection from
design serious mechanical impact

7 6 4 5 4 3 2 1
Perfect protection from rodents, Allowable tensile strength
suitable for duct installation up to 80 kN (using rope wire)

Resistance to crushing
loads up to 1 kN/сm

CONSTRUCTION:
1. Central strength member 4 Water-swellable gel.
(fiberglass reinforced plastic). 5. Inner jacket.
2. Optical fiber. 6. Armor of zinc-coated steel wires.
3. PBT loose tubes filled with 7. Jacket.
water-swellable gel.

61
Features
InGround Standard

Allowable tensile strength — 7 – 10 kN


Crush — from 0.4 kN/сm*
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96
Cable diameter, mm 12.4 12.6 13.0 13.2 14.2 14.2
Cable weight, kg/km 234.5 243 255.2 258.3 292.6 292.6
Min bending radius, mm 186 189 195 198 213 213

Allowable tensile strength — 16 – 20 kN


Crush — from 0.4 kN/сm*
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96
Cable diameter, mm 12.8 13.0 13.0 13.2 14.2 14.2
Cable weight, kg/km 247.4 250.5 249.6 258.3 292.6 292.6
Min bending radius, mm 192 195 195 198 213 213
InGround

Allowable tensile strength — 40 kN


Crush — from 1 kN/сm*
Fiber count to 24 (6×4) to 48 (6×8) to 72 (6×12) to 96 (6×16) to 144 (6×24)
Cable diameter, mm 15.9 16.2 16.8 17.2 18.4
Cable weight, kg/km 459.5 465.7 493.9 491.7 584.6
Min bending radius, mm 238.5 243.0 252.0 258.0 276.0

Allowable tensile strength — 80 kN


Crush — from 1 kN/сm*
Fiber count to 24 (6×4) to 48 (6×8) to 72 (6×12) to 96 (6×16) to 144 (6×24)
Cable diameter, mm 19.1 19.2 20.0 20.0 20.8
Cable weight, kg/km 789.6 791.6 848.6 848.1 899.5
Min bending radius, mm 286.5 288.0 300.0 300.0 312.0
* InGround Standard cable may be produced with Crush up to 1 kN/сm

62
InGround Standard Dielectric
(Multi-Tube Single Armor Double Jacket Cable)
Reduced weight, suitable for Reliable protection from
aerial installation serious mechanical
impact

7 6 4 5 4 3 2 1
Perfect protection from
All-dielectric
rodents, suitable for duct
construction
installation

CONSTRUCTION:
1. Central strength member 4. Water-swellable gel. Allowable tensile strength Resistance to crushing
(fiberglass reinforced plastic). 5. Inner jacket. up to 20 kN loads up to 1 kN/сm
2. Optical fiber. 6. Fiberglass rods.
3. PBT loose tubes filled with 7. Jacket.
water-swellable gel.

Features
InGround Standard Dielectric

InGround
Allowable tensile strength — 7 kN
Crush — from 0.4 kN/сm*
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable diameter, mm 12.4 12.6 13.0 13.2 14.4 14.4 17.6
Cable weight, kg/km 134.0 138.0 145.6 148.7 176.5 176.5 288.3
Min bending radius, mm 186 189 195 198 216 216 264

Allowable tensile strength — 16 kN


Crush — from 0.4 kN/сm*
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable diameter, mm 14.6 14.8 15.2 15.4 16.2 16.2 17.6
Cable weight, kg/km 206.1 209.6 221.9 224.4 244.3 244.3 288.3
Min bending radius, mm 219 222 228 231 243 243 264

63
Allowable tensile strength — 20 кН
Crush — from 0.4 kN/сm*
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable diameter, mm 15.6 15.8 16.2 16.4 17.0 17.0 17.6
Cable weight, kg/km 241.5 245.3 260.6 264.4 277.4 277.4 288.3
Min bending radius, mm 234 237 243 246 255 255 264

* InGround Standard Dielectric cable may be produced with Crush up to 1 kN/sm

InGround Standard Reinforced


(Multi-Tube Double Armor Double Jacket Cable)
InGround

Suitable for harsh environment Allowable tensile


applications: in cryosolic strength up to 80 kN
grounds, on the bottom of (using rope wire)
navigable rivers and basins.

7 6 4 5 4 3 2 1

Perfect protection from


Resistance to crushing rodents, suitable for duct
loads from 1 kN/сm installation

CONSTRUCTION:
1. Central strength member 4. Water-swellable gel.
(fiberglass reinforced plastic). 5. Inner jacket.
2. Optical fiber. 6. Double armor of zinc-coated steel wires.
3. PBT loose tubes filled with 7. Jacket.
water-swellable gel.

64
Features
InGround Standard Reinforced

Allowable tensile strength — 80 kN


Crush — from 1 kN/сm
Fiber count Up to 24 up to 48 up to 72 up to 96 up to 144
Cable diameter, mm 19.1 19.6 20.2 21.0 22.6
Cable weight, kg/km 766.7 818.8 857.3 924.8 1125.5
Min bending radius, mm 286.5 294.0 303.0 315.0 339.0

InGround Standard Reinforced Dielectric


(Multi-Tube Double Armor Double Jacket Cable)

Double armor makes the cable


Allowable tensile

InGround
suitable for harsh environ-
ment applications: in cryosolic strength up to 40 kN
grounds, on the bottom of
navigable rivers and basins.

7 6 4 5 4 3 2 1
Perfect protection from
Resistance to crushing rodents, suitable for duct
loads from 1 kN/сm installation.

All-dielectric
construction
CONSTRUCTION:
1. Central strength member 4. Water-swellable gel.
(fiberglass reinforced plastic). 5. Inner jacket.
2. Optical fiber. 6. Double armor of fiberglass plastic rods.
3. PBT loose tubes filled with 7. Jacket.
water-swellable gel.

65
Features
InGround Standard Reinforced Dielectric

Allowable tensile strength — 40 kN


Crush — from 1 kN/сm
Fiber count up to 24 up to 48 up to 72 up to 96 up to 144
Cable diameter, mm 21.1 21.6 22.2 22.6 23.4
Cable weight, kg/km 453.2 477.2 502.5 509.8 542.7
Min bending radius, mm 316,5 324.0 333.0 339.0 351.0

InGround Superlight
(Uni-Tube Single Armor Single Jacket Cable)
Efficient design Reduced weight and size

5 4 3 2 1
Reliable protection from Maximum resistance to
InGround

serious mechanical impact crushing loads


from 0.7 kN/сm

CONSTRUCTION:
1. Optical fiber. 3. Water-swellable gel. Perfect protection from
2. PBT loose tube filled with water- 4. Armor of zinc-coated steel wires. Up to 24 fibers rodents, suitable for duct
swellable gel. 5. Jacket. installation

Features
InGround Superlight

Allowable tensile strength — 7 kN


Crush — from 0.7 kN/сm
Fiber count up to 16 up to 24
Cable diameter, mm 9.5 9.7
Cable weight, kg/km 155.2 157.8
Min bending radius, mm 142.5 145.5

66
InGroung Superlight Dielectric
(Uni-Tube Single Armor Single Jacket Cable)
Reduced weight, suitable for All-dielectric
aerial installation construction

5 4 3 2 1 Reliable protection from Perfect protection from rodents,


serious mechanical impact suitable for duct installation

Maximum resistance to
Up to 24 fibers crushing loads
from 0.7 kN/сm
CONSTRUCTION:
1. Optical fiber. 3. Water-swellable gel.
2. PBT loose tube filled with wa- 4. Armor of fiberglass rods. Allowable tensile
ter-swellable gel. 5. Jacket. strength up to 8 kN

Features
InGroung Superlight Dielectric

InGround
Allowable tensile strength — 8 kN
Crush — from 0.7 kN/сm
Fiber count Up to 6 Up to 8 Up to12 up to 16 up to 24
Cable diameter, mm 10.7 10.7 10.7 10.7 10.9
Cable weight, kg/km 106.8 106.7 106.6 106.4 108.7
Min bending radius, mm 160.5 160.5 160.5 160.5 163.5

Allowable tensile strength — 9 kN


Crush — from 0.7 kN/сm
Fiber count Up to 6 Up to 8 Up to12 up to 16 up to 24
Cable diameter, mm 11.1 11.1 11.1 11.1 11.3
Cable weight, kg/km 113.6 113.5 113.4 113.2 121.2
Min bending radius, mm 166.5 166.5 166.5 166.5 169.5

67
Allowable tensile strength — 10 kN
Crush — from 0.7 kN/сm
Fiber count Up to 6 Up to 8 Up to12 up to 16 up to 24
Cable diameter, mm 11.3 11.3 11.3 11.3 11.5
Cable weight, kg/km 119.6 119.6 119.4 119.2 121.6
Min bending radius, mm 169.5 169.5 169.5 169.5 172.5

Allowable tensile strength — 12 kN


Crush — from 0.7 kN/сm
Fiber count Up to 6 Up to 8 Up to12 up to 16 up to 24
Cable diameter, mm 11.9 11.9 11.9 11.9 12.1
Cable weight, kg/km 139.0 138.9 138.8 138.6 141.1
Min bending radius, mm 178.5 178.5 178.5 178.5 181.5

InGround Superlight Reinforced


InGround

(Uni-Tube Double Armor Single Jacket Cable)

Maximum resistance to
Suitable for harsh
crushing loads
environment applications
from 1 kN/сm

5 4 3 2 1

Perfect protection from


Allowable tensile strength
rodents, suitable for duct
up to 50 kN
installation

CONSTRUCTION:
1. Optical fiber. 4. Double armor of zinc-coated
Up to 24 fibers
2. PBT loose tube filled with water- steel wires.
swellable gel. 5. Jacket.
3. Water-swellable gel.

68
Features
InGround Superlight Reinforced

Allowable tensile strength — 30 kN


Crush — from 1 kN/сm
Fiber count Up to12 up to 16 up to 24
Cable diameter, mm 11.8 11.9 12.2
Cable weight, kg/km 293.8 301.1 318.4
Min bending radius, mm 177 178.5 183

Allowable tensile strength — 40 kN


Crush — from 1 kN/сm
Fiber count Up to12 up to 16 up to 24
Cable diameter, mm 12.8 12.9 13.2
Cable weight, kg/km 374.8 382.3 407.5
Min bending radius, mm 192.0 193.5 198.0

InGround
Allowable tensile strength — 50 kN
Crush — from 1 kN/сm
Fiber count Up to12 up to 16 up to 24
Cable diameter, mm 13.6 13.7 14.0
Cable weight, kg/km 449.1 456.8 535.2
Min bending radius, mm 204.0 205.5 210.0

69
InGround Superlight Reinforced Dielectric
(Uni-Tube Double Armor Single Jacket Cable)

Double armor makes


the cable suitable for All-dielectric
harsh environment construction
5 4 3 2 1 applications

Reduced weight and Resistance to crushing


size. Convenient for loads from 1kN/сm
blowing-in tubes
CONSTRUCTION:
1. Optical fiber. 4. Double armor of fiberglass plastic rods.
2. PBT loose tube filled with water- 5. Jacket. Allowable tensile strength
swellable gel. up to 30 kN
3. Water-swellable gel.

Features
InGround Superlight Reinforced Dielectric
InGround

Allowable tensile strength — 15 kN


Crush — from 1 kN/сm
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24
Cable diameter, mm 12.7 12.7 12.7 12.7 12.9
Cable weight, kg/km 158.0 157.9 157.8 157.6 166.2
Min bending radius, mm 190.5 190.5 190.5 190.5 193.5

Allowable tensile strength — 20 kN


Crush — from 1 kN/сm
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24
Cable diameter, mm 14.3 14.3 14.3 14.3 14.5
Cable weight, kg/km 209.1 209.0 208.9 208.7 216.0
Min bending radius, mm 214.5 214.5 214.5 214.5 217.5

70
Allowable tensile strength — 30 kN
Crush — from 1 kN/сm
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24
Cable diameter, mm 15.9 15.9 15.9 15.9 16.1
Cable weight, kg/km 264.7 264.6 264.5 264.3 272.9
Min bending radius, mm 238.5 238.5 238.5 238.5 241.5

InGound Stainless Steel Tube


(Uni-Tube Single Armor Single Jacket Cable)

Up to 48 fibers
100% waterproof
in a tube
4 3 2 1

Resistance to extreme Allowable tensile strength


crushing loads –

InGround
up to 40 kN
from 1.4 kN/сm
CONSTRUCTION:
1. Optical fiber. 3. Armor of steel wires.
2. Stainless steel tube filled 4. Jacket.
with water-swellable gel.

Features
InGround Stainless Steel Tube

Allowable tensile strength — 7 kN


Crush — from 1.4 kN/сm

Fiber count up to 36 up to 48
Cable diameter, mm 9.6 9.9
Cable weight, kg/km 169.7 182.2
Min bending radius, mm 144.0 148.5

71
Allowable tensile strength — 10 kN
Crush — from 1.4 kN/сm
Fiber count up to 36 up to 48
Cable diameter, mm 10.4 10.7
Cable weight, kg/km 221.0 225.7
Min bending radius, mm 156.0 160,5

InGround Standard Wetland NEW

(Multi-Tube Single Armor Double Jacket Aluminum and Polymer Tape Cable)

Excellent solution for With laminated aluminium


wetland and cross-river polyethylene sheath –
installation to protect the cable core
from moisture
InGround

8 7 4 6 5 4 3 2 1
Resistance to crushing Allowable tensile strength
loads up to 1 kN/сm up to 80 kN

Aluminium compound
tape to protect
CONSTRUCTION: from hydrogen penetration
1. Central strength member 4 Water-swellable gel. into optical fiber
(fiberglass reinforced plastic). 5. Aluminum and polymer tape.
2. Optical fiber. 6. Inner jacket.
3. PBT loose tubes filled with 7. Armor of zinc-coated steel wires.
water-swellable gel. 8. Jacket.

72
Features
InGround Standard Wetland

Allowable tensile strength — 7 – 10 kN


Crush — from 0,4 kN/сm
up to 16 up to 32 up to 48 up to 64 up to 72 up to 96
Fiber count
(4x4) (4x8) (4x12) (4x16) (3x24) (4x24)
Cable diameter, mm 13.1 13.3 13.7 13.9 14.9 14.9
Cable weight, kg/km 259.8 268.5 281.5 290.4 325.6 325.6

Allowable tensile strength — 16 – 20 kN


Crush — from 0,4 kN/сm
up to 16 up to 32 up to 48 up to 64 up to 72 up to 96
Fiber count
(4x4) (4x8) (4x12) (4x16) (3x24) (4x24)
Cable diameter, mm 13.1 13.3 13.7 13.9 14.9 14.9
Cable weight, kg/km 259.8 262.9 275.9 284.8 320.0 320.0

Allowable tensile strength — 40 kN

InGround
Crush — from 1 kN/сm
Fiber count up to 24 (6x4) up to 48 (6x8) up to 72 (6×12) up to 96 (6x16) up to 144 (6x24)
Cable diameter, mm 16.0 16.3 16.9 17.3 18.5
Cable weight, kg/km 463.5 469.7 512.3 496.1 589.1

Allowable tensile strength — 80 kN


Crush — from 1 kN/сm
Fiber count up to 24 (6x4) up to 48 (6x8) up to 72 (6x12) up to 96 (6x16) up to 144 (6x24)
Cable diameter, mm 19.2 19.3 20.1 20.1 20.9
Cable weight, kg/km 794.0 796.0 853.1 852.9 904.3

73
InGround Standard Wetland Reinforced NEW

(Multi-Tube Double Armor Double Jacket Aluminum and Polymer Tape Cable)

Excellent solution for With laminated aluminium


wetland and cross-river polyethylene sheath –
installation to protect the cable core
from moisture
8 7 4 6 5 4 3 2 1

Resistance to crushing Allowable tensile strength


loads up to 1 kN/сm up to 80 kN

Aluminium compound
tape to protect
from hydrogen penetration
into optical fiber
CONSTRUCTION:
1. Central strength member 4 Water-swellable gel.
(fiberglass reinforced plastic). 5. Aluminum and polymer tape.
2. Optical fiber. 6. Inner jacket.
3. PBT loose tubes filled with 7. Double armor of zinc-coated steel wires.
InGround

water-swellable gel. 8. Jacket.

Features
InGround Standard Wetland Reinforced

Allowable tensile strength — 80 kN


Crush — from 1 kN/сm
Fiber count up to 24 (4x6) up to 48 (6x8) up to 72 (6x12) up to 96 (6x16) up to 144 (6x24)
Cable diameter, mm 19.4 19.7 20.1 20.7 22.7
Cable weight, kg/km 797.8 823.1 844.0 869.2 1130.3

74
Operation parameters InGround
Operation temperature range* -50°С…+70°С *
Installation temperature range -30°С…+50°С
Transportation and storage temperature range -60°С…+70°С
Min bending radius 15x cable diameter
Life time 25 years

* Operation temperature range can be increased on request

Options
All InGround cables may be produced in versions: Fireproof cable/Level 1 and Fireproof cable/Level 2 (page 30).
InGound Stainless Steel Tube cable may be produced with fire-resistant jacket (page 34).
We design cables based on our Customers' specific technical Requirements.

InGround
75
InWater
APPLICATION:

Applied in sea areas (coastal shelf and deep-sea), on navigable rivers, in lakes and water storage basins,
in harsh environments, in bogs and unnavigable rivers.

InWater Standard
(Uni-Tube Double Armor Double Jacket Cable)

Installation down Suitable for application


to 2500 m in harsh environments
11 10 9 8 7 6 5 4 3 2 1
InWater

CONSTRUCTION:
1. Optical fiber. 7. Aluminum and polymer tape.
2. Water-swellable gel. 8. Inner jacket.
3. Loose tube. 9. Water-swellable gel.
4. Water-swellable gel. 10. Armor of steel wires.
5. Armor of steel wires. 11. Jacket.
6. Water-blocking tape.

76
Features
InWater Standard

Allowable tensile strength — 20 – 70 kN


Crush — from 1.5 kN/сm
Fiber count up to 24
Tensile strength 20 кН 35 кН 50 кН 60 kN 70 kN
Cable diameter, mm 14.3 16.7 17.9 19.3 20.3
Cable weight, kg/km 378.7 618.7 776.1 948.2 1072.3
Min bending radius, mm 214.5 250.5 268.5 289.5 304.5

InWater Stainless Steel Tube


(Steel Tube Double Armor Double Jacket Cable)

Installation down Up to 48 fibers


to 5000 m in a tube

InWater
11 10 9 8 7 6 5 4 3 2 1

Suitable for application


in harsh environments

CONSTRUCTION:
1. Optical fiber. 7. Aluminum and polymer tape.
2. Water-swellable gel. 8. Inner jacket.
3. Steel tube. 9. Water-swellable gel.
4. Water-swellable gel. 10. Armor of steel wires.
5. Armor of steel wires. 11. Jacket.
6. Water-blocking tape.

77
Features
InWater Stainless Steel Tube

Allowable tensile strength — 20 kN


Crush — from 1.5 kN/сm 
Fiber count up to 12 up to 24 up to 36 up to 48
Cable diameter, mm 13.0 13.4 13.4 13.7
Cable weight, kg/km 324.5 353.6 347.9 357.2
Min bending radius, mm 195.0 201.0 201.0 205,5

Allowable tensile strength — 35 kN


Fiber count up to 12 up to 24 up to 36 up to 48
Cable diameter, mm 14.6 15.0 15.2 15.3
Cable weight, kg/km 489.6 507.0 521.8 513.0
Min bending radius, mm 219.0 225.0 228.0 229,5

Allowable tensile strength — 50 kN


Fiber count up to 12 up to 24 up to 36 up to 48
Cable diameter, mm 16.6 16.6 16.8 16.9
InWater

Cable weight, kg/km 678.2 682.3 681.5 683.2


Min bending radius, mm 249.0 249.0 252.0 253.5

Allowable tensile strength — 60 kN


Fiber count up to 12 up to 24 up to 36 up to 48
Cable diameter, mm 17.4 17.6 17.6 17.9
Cable weight, kg/km 783.8 794.4 791.0 814.5
Min bending radius, mm 261.0 264.0 264.0 268.5

78
Allowable tensile strength — 70 kN
Fiber count up to 12 up to 24 up to 36 up to 48
Cable diameter, mm 18.4 18.8 18.8 18.7
Cable weight, kg/km 889.3 938.6 935.0 942.1
Min bending radius, mm 276.0 282.0 282.0 280.5

Allowable tensile strength — 80 – 85 kN


Fiber count up to 12 up to 24 up to 36 up to 48
Cable diameter, mm 19.8 19.8 19.8 20.1
Cable weight, kg/km 1045.8 1045.8 1045.8 1089.8
Min bending radius, mm 297.0 297.0 297.0 301.5

Operation parameters InWater


Operation temperature range -50°С…+70°С
Installation temperature range * -30°С…+50°С
Transportation and storage temperature range -60°С…+70°С
Min bending radius 15x cable diameter

InWater
Life time 25 years
Warranty lifetime as specified in the supply agreement, min 2 years

* Operation temperature range can be increased on request.

We design cables based on our Customers' specific technical Requirements.

79
InAir Figure 8
APPLICATION:

Applied for aerial installations: on power lines, lamp posts, between buildings
and constructions. Suitable for aerial installation on transmission equipment
and power facilities in dielectric package

InAir Figure 8 Standard


(Multi-Tube Single Jacket Cable)

Affordable alternative to Low installation cost


InAir Self-Supporting Cable

5 4 3 2 1
InAir Figure 8

CONSTRUCTION:
1. Central strength member 4. Water-swellable gel.
(dielectric fiberglass reinforced plastic). 5. Jacket.
2. Optical fiber. 6. Steel wire.
3. PBT loose tubes filled with
water-swellable gel.

80
Features
InAir Figure 8 Standard

Elasticity modulus – 125 kN/mm2


Crush – from 0.3 kN/сm

Allowable tensile strength — 4 kN


Outer diameter of the external strength member — 5.2 mm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable diameter, mm 8.6 8.9 9.3 9.8 10.4 11.4 13.8
Max overall cable size, mm 15.8 16.1 16.5 17.0 17.6 18.6 21.0
Equivalent cable diameter, mm 10.3 10.6 10.9 11.3 11.8 12.7 14.7
Cable weight, kg/km 99.7 101.9 107.2 113.0 125.6 141.0 180.5

Allowable tensile strength — 6 kN


Outer diameter of the external strength member — 5.8 mm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable diameter, mm 8.6 8.9 9.3 9.8 10.4 11.4 13.8
Max overall cable size, mm 16.4 16.7 17.1 17.6 18.2 19.2 21.6
Equivalent cable diameter, mm 10.6 10.8 11.2 11.6 12.1 12.9 15.0
Cable weight, kg/km 116.9 119.1 124.3 130.1 142.8 158.1 197.8

InAir Figure 8
Allowable tensile strength — 9 kN
Outer diameter of the external strength member — 6.4 mm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable diameter, mm 8.6 8.9 9.3 9.8 10.4 11.4 13.8
Max overall cable size, mm 17.0 17.3 17.7 18.2 18.8 19.8 22.2
Equivalent cable diameter, mm 10.8 11.1 11.4 11.8 12.3 13.2 15.2
Cable weight, kg/km 137.5 139.7 144.9 150.7 163.6 178.7 218.4

81
Allowable tensile strength — 12 kN
Outer diameter of the external strength member — 7.0 mm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable diameter, mm 8.6 8.9 9.3 9.8 10.4 11.4 13.8
Max overall cable size, mm 17.6 17.9 18.3 18.8 19.4 20.4 22.8
Equivalent cable diameter, mm 11.1 11.3 11.7 12.1 12.6 13.4 15.5
Cable weight, kg/km 161.6 163.8 169.0 174.8 187.5 202.8 242.5

InAir Standard Dielectric Figure 8


(Multi-Tube Single Jacket Cable)

All-dielectric Affordable alternative


6 construction to InAir self-supporting
cable

5 4 3 2 1
Low installation cost
InAir Figure 8

CONSTRUCTION:
1. Central strength member 4. Water-swellable gel.
(dielectric fiberglass reinforced plastic). 5. Jacket.
2. Optical fiber. 6. Dielectric rod.
3. PBT loose tubes filled with water-
swellable gel.

82
Features
InAir Standard Dielectric Figure 8

Elasticity modulus – 50 kN/mm2


Crush – from 0.3 kN/сm

Allowable tensile strength — 4 kN


Outer diameter of the external strength member — 6.5 mm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable diameter, mm 8.6 8.9 9.3 9.8 10.4 11.4 13.8
Max overall cable size, mm 17.1 17.4 17.8 18.3 18.9 19.9 22.3
Equivalent cable diameter, mm 10.9 11.1 11.5 11.9 12.4 13.2 15.3
Cable weight, kg/km 102.4 104.6 109.9 115.6 128.3 143.7 183.4

Allowable tensile strength — 6 kN


Outer diameter of the external strength member — 7.5 mm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable diameter, mm 8.6 8.9 9.3 9.8 10.4 11.4 13.8
Max overall cable size, mm 18.1 18.4 18.8 19.3 19.9 20.9 23.3
Equivalent cable diameter, mm 11.3 11.5 11.9 12.3 12.8 13.6 15.7
Cable weight, kg/km 120.1 122.3 127.5 133.3 146.0 161.3 201.0

InAir Figure 8
83
InAir Superlight Figure 8
(Uni-Tube Single Jacket Cable)

4 Reduced weight
Efficient design
and size

3 2 1
Low installation cost

CONSTRUCTION:
1. Optical fiber. 3. Jacket.
2. PBT loose tube filled with water- 4. Steel wire.
swellable gel.

Features
InAir Superlight Figure 8

Elasticity modulus – 125 kN/mm2


Crush – from 0.3 kN/сm
InAir Figure 8

Allowable tensile strength — 4 kN


Outer diameter of the external strength member — 5.0 mm
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24
Cable diameter, mm 6.2 6.3 6.5 6.7 7.0
Max overall cable size, mm 12.2 12.3 12.5 12.7 13.0
Equivalent cable diameter, mm 7.8 7.9 8.0 8.2 8.5
Cable weight, kg/km 70.6 71.4 73.2 75.1 77.9

84
Allowable tensile strength – 6 kN
Outer diameter of the external strength member — 5.6 mm
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24
Cable diameter, mm 6.2 6.3 6.5 6.7 7.0
Max overall cable size, mm 12.8 12.9 13.1 13.3 13.6
Equivalent cable diameter, mm 8.0 8.1 8.3 8.5 8.7
Cable weight, kg/km 87.5 88.4 90.2 92.1 94.9

Allowable tensile strength — 9 kN


Outer diameter of the external strength member — 6.2 mm
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24
Cable diameter, mm 6.2 6.3 6.5 6.7 7.0
Max overall cable size, mm 13.4 13.5 13.7 13.9 14.2
Equivalent cable diameter, mm 8.3 8.4 8.5 8.7 9.0
Cable weight, kg/km 108.0 108.9 110.6 112.5 115.3

Allowable tensile strength — 12 kN


Outer diameter of the external strength member — 6.8 mm
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24
Cable diameter, mm 6.2 6.3 6.5 6.7 7.0
Max overall cable size, mm 14.0 14.1 14.3 14.5 14.8
Equivalent cable diameter, mm 8.5 8.6 8.8 9.0 9.2

InAir Figure 8
Cable weight, kg/km 131.9 132.8 134.6 136.4 139.2

85
InAir Superlight Dielectric Figure 8
(Uni-Tube Single Jacket Cable)

All-dielectric Reduced weight


4 construction and size

3 2 1
Efficient design

CONSTRUCTION:
1. Optical fiber. 3. Jacket.
2. PBT loose tube filled with water- 4. Dielectric rod.
swellable gel.

Features
InAir Superlight Dielectric Figure 8

Elasticity modulus – 50 kN/mm2


Crush – from 0.3 kN/сm
InAir Figure 8

Allowable tensile strength — 4 kN


Outer diameter of the external strength member — 6.3 mm
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24
Cable diameter, mm 6.2 6.3 6.5 6.7 7.0
Max overall cable size, mm 13.5 13.6 13.8 14.0 14.3
Equivalent cable diameter, mm 8.3 8.4 8.6 8.7 9.0
Cable weight, kg/km 72.9 73.7 75.5 77.4 80.2

86
Allowable tensile strength — 6 kN
Outer diameter of the external strength member — 7.3 mm
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24
Cable diameter, mm 6.2 6.3 6.5 6.7 7.0
Max overall cable size, mm 14.5 14.6 14.8 15.0 15.3
Equivalent cable diameter, mm 8.7 8.8 9.0 9.2 9.4
Cable weight, kg/km 90.2 91.1 92.9 94.7 97.5

InAir Superlight Dielectric Figure 8


(Uni-Tube Single Jacket Double Dielectric Rod Cable)

All-dielectric Reduced weight


construction and size
4

3 2 1
Efficient design High crush resistance

Suitable for aerial

InAir Figure 8
Low ice and wind load
installation up to 100 m

Applied as ‘the last mile’ in


CONSTRUCTION: cottage villages
1. Optical fiber. 3. Jacket.
2. PBT loose tube filled with water- 4. Dielectric rod.
swellable gel.

87
Features
InAir Superlight Dielectric Figure 8

Crush – from 1.4 kN/сm


Tensile strength, kN 1.3 1.4 1.7 2.2
Fiber count up to 8 up to 12 up to 16 up to 24
Overall cable size, mm 3 × 7.6 3.1 × 8 3.3 × 8.6 3.6 × 9.5
Cable weight, kg/km 27.1 29.5 34.0 41.5

InAir Figure 8 Stainless Steel Tube

4
Up to 48 fibers High crush resistance
in a tube
3

2 1
InAir Figure 8

3. Jacket.
CONSTRUCTION: 4. Steel wire.
1. Optical fiber.
2. Stainless steel tube filled
with water-swellable gel.

88
Features
InAir Figure 8 Stainless Steel Tube

Allowable tensile strength — 4 kN


Crush — from 0.7 kN/сm
Outer diameter of the external strength member — 5.6 mm

Fiber count up to 24 up to 36 up to 48
Cable diameter, mm 5.6 6.0 6.3
Max overall cable size, mm 12.2 12.6 12.9
Equivalent cable diameter, mm 7.5 7.9 8.1
Cable weight, kg/km 93.6 98.5 101.6

Allowable tensile strength — 6 kN


Crush — from 0.7 kN/сm
Outer diameter of the external strength member — 5.9 mm
Fiber count up to 24 up to 36 up to 48
Cable diameter, mm 5.6 6.0 6.3
Max overall cable size, mm 12.5 12.9 13.2
Equivalent cable diameter, mm 7.6 8.0 8.2
Cable weight, kg/km 103.4 108.3 111.4

InAir Figure 8
Operation parameters InAir Figure 8
Operation temperature range* -60°С…+70°С
Installation temperature range -30°С…+50°С
Transportation and storage temperature range -60°С…+70°С
Min bending radius 15x cable diameter
Life time 25 years

* Operation temperature range can be increased on request


We design cables based on our Customers' specific technical Requirements.

89
InAir ADSS
APPLICATION:

Designed for aerial


installation on transmission
towers, high voltage
Applied inside Applied for direct-buried
power lines and railway
buildings installation in protecting
catenary; highly resistant
tubes
to electromagnetic effect

InAir ADSS Standard Aramid C ER T IF


IED

(Multi-Tube Aramid Double Jacket Cable)

Aerial installation Wide range of operating


on 35 kV power lines temperatures. Installation
and above temperature down to -30°C

7 6 5 4 3 2 1
All-dieletric For construction of
construction –fully resistant
to electromagnetic fields
500 communication lines between
towns and cities with
distances between towers
reaching 500 m

CONSTRUCTION:
InAir ADSS

The most reliable among Maximum tensile


1. Central strength member 4. Water-swellable gel. InAir cables. Double tensile load up to 100 kN
(dielectric fiberglass reinforced plastic). 5. Inner jacket. strength
2. Optical fiber. 6. Reinforcing member – aramid yarns.
3. PBT loose tubes filled 7. Jacket.
with water-swellable gel.

90
Features
InAir ADSS Standard Aramid

Crush for all cables of the group — from 0.3 kN/сm


Allowable tensile strength — 4 kN Allowable tensile strength — 10 kN
up to up to up to up to up to up up up to
Fiber count 48 72 96 144 Fiber count 48 to 72 to 96 144
(6×8) (6×12) (6×16) (6×24) (6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 12.2 12.8 13.5 14.1 Cable diameter, mm 12.5 13.0 13.7 14.3
Cable weight, kg/km 114.0 124.5 135.8 146.2 Cable weight, kg/km 120.9 129.6 140.8 152.1
Min bending radius, mm 183 192 203 212 Min bending radius, mm 188 195 206 215

Allowable tensile strength — 6 kN Allowable tensile strength — 12 kN


up to up to up to up to up to up to up to up to
Fiber count 48 72 96 144 Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24) (6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 12.2 12.8 13.5 14.1 Cable diameter, mm 12.7 13.3 13.9 14.5
Cable weight, kg/km 114.0 124.5 135.8 146.2 Cable weight, kg/km 125.6 136.1 145.5 157.1
Min bending radius, mm 183 192 203 212 Min bending radius, mm 191 200 209 218

Allowable tensile strength — 7 kN Allowable tensile strength — 15 kN


up to up to up to up to up to up to up to up to
Fiber count 48 72 96 144 Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24) (6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 12.3 12.9 13.5 14.1 Cable diameter, mm 13.0 13.6 14.1 14.7
Cable weight, kg/km 116.8 126.4 135.8 146.2 Cable weight, kg/km 133.7 144.2 151.1 163.8
Min bending radius, mm 185 194 203 212 Min bending radius, mm 195 204 212 221

InAir ADSS
Allowable tensile strength — 8 kN Allowable tensile strength — 20 kN
up to up to up to up to up to up to up to up to
Fiber count 48 72 96 144 Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24) (6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 12.4 12.9 13.6 14.2 Cable diameter, mm 13.8 14.4 15.2 15.8
Cable weight, kg/km 118.2 127.0 137.8 148.9 Cable weight, kg/km 149.2 159.7 163.9 175.8
Min bending radius, mm 186 194 204 213 Min bending radius, mm 207 216 228 237
91
Allowable tensile strength — 25 kN Allowable tensile strength — 40 kN
up to up to up to up to up to up to up to up to
Fiber count 48 72 96 144 Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24) (6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 14.4 14.9 15.7 16.3 Cable diameter, mm 16.5 17.0 17.5 18.1
Cable weight, kg/km 163.2 171.5 173.8 184.8 Cable weight, kg/km 201.4 211.3 222.8 233.6
Min bending radius, mm 216 224 236 245 Min bending radius, mm 248 255 263 272

Allowable tensile strength — 30 kN


up to up to up to up to
Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 15.0 15.5 16.0 16.6
Cable weight, kg/km 171.0 181.1 182.3 195.0
Min bending radius, mm 225 233 240 249

Allowable tensile strength — 35 kN


up to up to up to up to
Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 16.1 16.6 17.2 17.8
Cable weight, kg/km 191.5 201.8 212.8 223.9
Min bending radius, mm 242 249 258 267
InAir ADSS

92
InAir ADSS Standard Fiberglass
(Multi-Tube Fiberglass Double Jacket Cable)

Aerial suspension
Cost-effective solution
on 35 kV power lines
for city trunk lines
and above
7 6 5 4 3 2 1

Wide range of operating In duct applications


temperatures. Installation fiberglass yarns protect
temperature down to -30°C the cable from rodents
(medium protection level)

CONSTRUCTION:
1. Central strength member 4. Water-swellable gel.
(dielectric fiberglass reinforced plastic). 5. Inner jacket. Application up to
All-dielectric
2. Optical fiber. 6. Reinforcing member – fiberglass construction – fully resistant to 300 15 kN with span lengths
up to 300 m
3. PBT loose tubes filled with water- yarns. electromagnetic fields
swellable gel. 7. Jacket.

Features
InAir ADSS Standard Fiberglass

Crush for all cables of the group — from 0.3 kN/сm


Allowable tensile strength — 4 kN Allowable tensile strength — 7 kN
up to up to up to up to up to up to up to up to
Fiber count 48 72 96 144 Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24) (6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 12.7 13.3 13.9 14.5 Cable diameter, mm 12.7 13.3 13.9 14.5
Cable weight, kg/km 125.6 137.2 149.1 159.2 Cable weight, kg/km 125.6 137.2 149.1 159.2
Min bending radius, mm 191 200 209 218 Min bending radius, mm 191 200 209 218

InAir ADSS
Allowable tensile strength — 6 kN Allowable tensile strength — 8 kN
up to up to up to up to up to up to up to up to
Fiber count 48 72 96 144 Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24) (6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 12.7 13.3 13.9 14.5 Cable diameter, mm 12.9 13.4 13.9 14.5
Cable weight, kg/km 125.6 137.2 149.1 159.2 Cable weight, kg/km 129.4 139.1 149.1 159.2
Min bending radius, mm 191 200 209 218 Min bending radius, mm 194 201 209 218

93
Allowable tensile strength — 10 kN Allowable tensile strength — 15 kN
up to up to up to up to up to up to up to up to
Fiber count 48 72 96 144 Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24) (6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 13.1 13.7 14.2 14.8 Cable diameter, mm 14.0 14.5 14.8 15.4
Cable weight, kg/km 135.2 146.7 155.4 166.6 Cable weight, kg/km 157.6 166.1 170.6 185.7
Min bending radius, mm 197 206 213 222 Min bending radius, mm 210 218 222 231

Allowable tensile strength — 12 kN


up to up to up to up to
Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 13.5 14.0 14.3 15.0
Cable weight, kg/km 145.3 152.9 156.9 174.0
Min bending radius, mm 203 210 215 225

InAir ADSS Light Aramid


(Multi-Tube Aramid Single Jacket Cable)
Aerial suspension Dry construction –
on 35 kV power lines easy to strip
and above

6 5 4 3 2 4 1 Reduced weight Cost-effective


and size. Low ice design
InAir ADSS

and wind load

All-dielectric Application up to
construction – fully resistant
to electromagnetic fields
200 10 kN with span lengths
up to 200 m
CONSTRUCTION:
1.Central strength member 4. Water-blocking yarns.
(dielectric fiberglass reinforced plastic). 5. Reinforcing member – aramid yarns.
Wide range of operating
2. Optical fiber. 6. Jacket. temperatures. Installation
3.PBT loose tubes filled temperature down to -30°C
with water-swellable gel.

94
Features
InAir ADSS Light Aramid

Crush for all cables of the group — from 0.3 kN/сm


Allowable tensile strength — 4 kN Allowable tensile strength — 8 kN
up to up to up to up to up to up to up to up to
Fiber count 48 72 96 144 Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24) (6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 10.8 11.4 12.0 12.6 Cable diameter, mm 11.0 11.6 12.1 12.7
Cable weight, kg/km 88.8 97.5 106.2 115.4 Cable weight, kg/km 92.6 101.6 108.0 117.3
Min bending radius, mm 162 171 180 189 Min bending radius, mm 165 174 182 191

Allowable tensile strength — 6 kN Allowable tensile strength — 10 kN


up to up to up to up to up to up to up to up to
Fiber count 48 72 96 144 Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24) (6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 10.9 11.4 12.0 12.6 Cable diameter, mm 11.2 11.7 12.3 12.9
Cable weight, kg/km 90.5 97.5 106.2 115.4 Cable weight, kg/km 96.9 104.1 112.4 122.1
Min bending radius, mm 164 171 180 189 Min bending radius, mm 168 176 185 194

Allowable tensile strength —7 kN


up to up to up to up to
Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 10.9 11.5 12.1 12.7
Cable weight, kg/km 91.3 99.2 108.0 117.3

InAir ADSS
Min bending radius, mm 164 173 182 191

95
InAir ADSS Light Fiberglass
(Multi-Tube Fiberglass Single Jacket Cable)

Cost-effective solution Aerial suspension


for city trunk lines on 35 kV power lines
and above

6 5 4 3 2 4 1 Reduced weight
Dry construction –
and size. Low ice
easy to strip
and wind load

All-dielectric Application up to
construction –
fully resistant to
200 10 kN with span lengths
up to 200 m
CONSTRUCTION: electromagnetic fields
1.Central strength member 4. Water blocking yarns.
(dielectric fiberglass reinforced plastic). 5. Reinforcing member – fiberglass Wide range of operating
2. Optical fiber. yarns. temperatures. Installation
3. PBT loose tubes filled 6. Jacket. temperature down to -30°C
with water-swellable gel.

Features
InAir ADSS Light Fiberglass

Crush for all cables of the group — from 0.3 kN/сm


Allowable tensile strength — 4 kN Allowable tensile strength — 6 kN
up to up to up to up to up to up to up to up to
Fiber count 48 72 96 144 Fiber count 48 72 96 144
InAir ADSS

(6×8) (6×12) (6×16) (6×24) (6×8) (6×12) (6×16) (6×24)


Cable diameter, mm 11.3 11.9 12.5 13.1 Cable diameter, mm 11.3 11.9 12.5 13.1
Cable weight, kg/km 99.9 108.2 117.9 128.3 Cable weight, kg/km 99.9 108.2 117.9 128.3
Min bending radius, mm 170 179 188 197 Min bending radius, mm 170 179 188 197

96
Allowable tensile strength — 7 kN Allowable tensile strength — 10 kN
up to up to up to up to up to up to up to up to
Fiber count 48 72 96 144 Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24) (6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 11.4 12.0 12.5 13.1 Cable diameter, mm 11.9 12.4 12.9 13,5
Cable weight, kg/km 101.6 110.0 117.9 128.3 Cable weight, kg/km 111.7 118.9 125.8 136.6
Min bending radius, mm 171 180 188 197 Min bending radius, mm 179 186 194 203

Allowable tensile strength — 8 kN


up to up to up to up to
Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 11.6 12.1 12.7 13.2
Cable weight, kg/km 105.2 111.9 121.8 130.4
Min bending radius, mm 174 182 191 198

InAir ADSS Micro Aramid


(Multi-Tube Aramid Single Jacket Cable, Reduced Size)
Recommended for All-dielectric
installation on power construction – fully resistant
lines up to 10 kV to electromagnetic fields

6 5 4 3 2 4 1
Reduced weight and size.
Low ice and wind load. Cost-effective
Suitable for blowing-in into design

InAir ADSS
protecting tubes

Wide range of operating Dry construction –


temperatures. Installation easy to strip
CONSTRUCTION: temperature down to -30°C
1. Central strength member 4. Water-blocking yarns.
(dielectric fiberglass reinforced plastic). 5. Reinforcing member – aramid yarns.
2. Optical fiber. 6. Jacket. Application up to
3. PBT loose tubes filled with 3 kN with span
water-swellable gel. lengths up to 50 m

97
Features
InAir ADSS Micro Aramid

Crush – from 0.3 kN/сm


Allowable tensile strength — 1.5 kN Allowable tensile strength — 3 kN
up to up to up to up to up to up to up to up to
Fiber count 48 72 96 144 Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24) (6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 7.6 8.3 9.2 10.0 Cable diameter, mm 7.8 8.4 9.2 10.0
Cable weight, kg/km 43.0 49.9 60.5 69.7 Cable weight, kg/km 46.8 52.7 61.1 69.7
Min bending radius, mm 114 125 138 150 Min bending radius, mm 117 126 138 150

Allowable tensile strength — 2 kN


up to up to up to up to
Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24)
Cable diameter, mm 7.6 8.3 9.2 11.0
Cable weight, kg/km 44.4 50.3 60.5 69.7
Min bending radius, mm 114 125 138 150
InAir ADSS

98
InAir ADSS Micro Fiberglass
(Multi-Tube Fiberglass Single Jacket Cable, Reduced Size)

Recommended for The most cost-effective


installation on power design
lines up to 10 kV
4
6 5 2 4 1
3
Reduced weight and size. All-dielectric
Low ice and wind load. construction – fully resistant
Suitable for blowing-in into to electromagnetic fields
protecting tubes

CONSTRUCTION: Wide range of operating


1. Central strength member 4. Water-blocking yarns. Dry construction –
temperatures. Installation
easy to strip
(dielectric fiberglass reinforced plastic). 5. Reinforcing member – fiberglass temperature down to -30°C
2. Optical fiber. yarns.
3.PBT loose tubes filled 6. Jacket.
with water-swellable gel. Application up to
3 kN with span
lengths up to 50 m

Features
InAir ADSS Micro Fiberglass
Crush – from 0.3 kN/сm
Allowable tensile strength — 2 kN Allowable tensile strength — 3 kN
up to up to up to up to up to up to up to up to
Fiber count 48 72 96 144 Fiber count 48 72 96 144
(6×8) (6×12) (6×16) (6×24)

InAir ADSS
(6×8) (6×12) (6×16) (6×24
Cable diameter, mm 8.4 9.1 10.7 11.5 Cable diameter, mm 9.3 9.8 10.7 11.5
Cable weight, kg/km 55.6 64.2 87.2 97.2 Cable weight, kg/km 68.6 74.5 87.2 97.2
Min bending radius, mm 126 137 161 173 Min bending radius, mm 140 147 153 173

99
Metallic aerial self-supporting (MASS)
Increased ASC wire makes
tensile strength – the cable exceedingly rustproof
3 2 1 up to 125 kN

Large spans between


High strength, towers, installation over
small size rivers and ravines
CONSTRUCTION:
1. Optical fiber.
2. Stainless steel tube filled with water-swellable gel.
3. Stranded wires (steel zinc-coated wires or Aluminum Clad Steel wires).

Features
MASS

Crush – from 1 kN/сm


Allowable tensile strength — 30 kN
Fiber count up to 12 up to 24 up to 36 up to 48
Cable diameter, mm 8.2 8.2 8.7 8.7
Cable weight, kg/km 288.5 288.5 318.3 318.3
InAir ADSS

Allowable tensile strength — 50 kN

Fiber count up to 12 up to 24 up to 36 up to 48
Cable diameter, mm 10.4 10.4 10.8 10.9
Cable weight, kg/km 486.0 485.3 520.2 521.1

100
Allowable tensile strength — 75 kN

Fiber count up to 12 up to 24 up to 36 up to 48
Cable diameter, mm 12.7 12.7 12.7 12.7
Cable weight, kg/km 711.7 711.7 711.7 711.7

Allowable tensile strength — 100 kN

Fiber count up to 12 up to 24 up to 36 up to 48
Cable diameter, mm 14.0 14.5 14.5 14.5
Cable weight, kg/km 900.4 948.9 948.9 948.9

Operation parameters InAir ADSS


Operation temperature range* -60°С…+70°С (MASS -60°С … +80°С)
Installation temperature range -30°С…+50°С
Transportation and storage temperature range -60°С…+70°С
Min bending radius 15xcable diameter
Life time 25 years

*Operation temperature range can be increased on request.

InAir ADSS
Options
All cables of this group may be produced in versions: Fireproof cable/Level 2 (page 30) and with jacket which is made of a tracking-resistant
material (can be used in case of cable exposure to the electric field with a potential above 12 kV).
We design cables based on our Customers' specific technical Requirements.

101
Indoor Fiber
Optic Cable

FTTH-Distribution FTTH-Subscribers HTTP-Drop


page 98 page 107 page 113

103
FTTH-Distribution
Riser
APPLICATION:

Applied for aerial installations: power lines, lamp posts, between


Applied in ducts, trays, blocks, tunnels, collecting
buildings and constructions
channels in protecting tubes

Tight-Buffered Riser
FTTH-Distribution

Perfect solution for high All-dielectric


3 buildings: the fiber is buffered construction
up to floor box or up to the
5 subscriber’s flat

4 2 1

Operation temperature range Easy access to the fiber


down to -30C at any place of the cable

Flame-retardant UV-resistant
CONSTRUCTION:
1. Optical fiber. 4. Halogen free flame-retardant jacket.
2. Tight-buffer. 5. Match marks (jacket opening Allowable tensile
3. Fiberglass rods. marking). Up to 48 fibers strength up to 400 N

Resistance to crushing
loads — 80-200 N/сm

104
Features
Tight-Buffered Riser

Allowable tensile strength — 400 N


Min crush — 80 N/сm
Max crush — 200 N/сm
Fiber count up to 4 up to 12 up to 24 up to 36 up to 48
Cable diameter, mm 6.5 8.5 10.5 13.5 13.5
Cable weight, kg/km 42 64 91 148 160
Min bending radius, mm 65 85 105 135 135

Riser with Micro Tubes

FTTH-Distribution
Perfect solution for multi-dwelling All-dielectric
unitss: a separate micro loose tube construction
3 is guided to every inter-floor box.
With 100% penetration, the number
5 of micro loose tubes equals to the
number of floors, the number of
4 2 1 fibers equals to the number of flats Flame-retardant
on the floor

Operation temperature Easy access to fiber


down to -30C at any place of the cable

CONSTRUCTION:
1. Optical fiber. 4. Halogen free flame-retardant jacket. High density of fibers
2. Micro tubes. 5. Match marks (jacket opening makes it possible to bundle
UV- resistant up to 24 fibers into micro
3. Fiberglass rods. marking).
loose tubes and place up
to 48 micro loose tubes in
a cable

Allowable tensile Resistance to crushing


strength up to 400 N loads — 80-200 N/сm

105
Features
Riser with Micro Tubes

Allowable tensile strength — 400 N


Min crush — 80 N/сm
Max crush — 200 N/сm
8 12 16 24 32 40 48 64 72 96 144 288
Fiber count
(2×4) (3×4) (4×4) (6×4) (8×4) (10×4) (12×4) (16×4) (12×6) (16×6) (24×6) (24×12)
Cable diameter, mm 6.5 6.5 6.5 8.5 8.5 8.5 10.5 10.5 10.5 13.5 13.5 14.5
Cable weight, kg/km 40.1 41.2 42.0 58.4 60.3 62.3 78.6 82.5 82.2 133.0 143.2 163.2
Min bending radius, mm 65 65 65 85 85 85 105 105 105 135 135 145

Operation parameters Riser


FTTH-Distribution

Operation temperature range (IEC 794-1-F5B) -30°С…+50°С*


Installation temperature range -10°С…+50°С
Transportation and storage temperature range -60°С…+70°С
Min bending radius 10x cable diameter
Life time 25 years

* Operation temperature range can be increased on request.


Different combinations of fiber counts and loose tubes in a cable are available on request.

106
Distribution
APPLICATION:

Applied inside buildings (including vertical


runs), in trays, channels, on outer sides Applied for aerial installations: power
Applied in ducts, trays, blocks, tunnels,
of buildings, as well as in duct, in tubes lines, lamp posts, between buildings and
collecting channels in protecting tubes
and blocks. Suitable for blowing-in into constructions
protecting polyethylene tubes

Tight-Buffered Distribution
Perfect solution for offices All-dielectric

FTTH-Distribution
and data centers construction
4 3 2 1

More flexible compared to the Easy termination


Riser Cable

Flame-retardant UV-resistant
CONSTRUCTION:
1. Optical fiber.
2. Tight-buffer.
3. Reinforcing elements — aramid yarns. Allowable tensile
4. Halogen free flame-retardant jacket. Up to 48 fibers strength up to 400 N

Resistance to crushing
loads from 100 N/сm

107
Features
Tight-Buffered Distribution

Allowable tensile strength:


Tight-Buffered Distribution for Indoor Installation — 200 N — operation; 400 N — installation
Tight-Buffered Distribution for Indoor and Outdoor Installation — 400 N — operation; 800 N — installation

Crush:
Tight-Buffered Distribution for Indoor Installation— from 100 N/сm
Tight-Buffered Distribution for Indoor and Outdoor Installation — from 200 Н/сm

FOR INDOOR INSTALLATION


Fiber count 2 4 8 12 16 24 32 36 48
Cable diameter, mm 4.4 4.9 5.7 6.4 7.0 7.9 9.9 10.4 11.6
Cable weight, kg/km 22.1 26.9 35.8 44.2 51.9 65.4 84.0 90.4 109.1
FTTH-Distribution

Min bending radius, mm 44 49 57 64 70 79 99 104 116

FOR INDOOR AND OUTDOOR INSTALLATION


Fiber count 2 4 8 12 16 24 32 36 48
Cable diameter, mm 4.7 5.2 5.9 6.5 7.1 8.1 10.1 10.6 11.7
Cable weight, kg/km 25.5 30.4 38.4 45.9 54.0 68.3 86.5 92.9 111.3
Min bending radius, mm 47 52 59 65 71 81 101 106 117

108
Distribution with Micro Tubes
All-dielectric UV-resistant
construction
4 3 2 1

High density of fibers makes


Flame-retardant it possible to bundle up to 24
fibers into micro loose tubes
and place up to 48 micro
loose tubes in a cable
CONSTRUCTION:
1. Optical fiber.
2. Micro tubes. Resistance to crushing Allowable tensile
3. Reinforcing elements — aramid yarns. loads from 100 N/сm strength up to 400 N
4. Halogen-free flame-retardant jacket.

Features

FTTH-Distribution
Distribution with Micro Tubes

Allowable tensile strength:


Distribution with Micro Tubes for Indoor Installation — 400 N — operation; 800 N — installation
Distribution with Micro Tubes for indoor and outdoor installation — 800 N — operation; 1600 N — installation

Crush — from 100 N/сm

FOR INDOOR INSTALLATION


8 8 12 16 24 36 48 64 72 96 144
Fiber count
(2×4) (4×2) (2×6) (4×4) (6×4) (6×6) (8×6) (16×4) (12×6) (16×6) (24×6)
Cable diameter, mm 5.1 5.5 5.4 5.8 6.3 7.0 7.6 8.4 8.6 9.5 11.1
Cable weight, kg/km 26.1 29.7 28.6 32.0 37.3 42.9 49.0 59.2 60.0 95.0 89.5
Min bending radius, mm 51 55 54 58 63 70 76 84 86 95 111

109
FOR INDOOR AND OUTDOOR INSTALLATION
8 8 12 16 24 36 48 64 72 96 144
Fiber count
(2×4) (4×2) (2×6) (4×4) (6×4) (6×6) (8×6) (16×4) (12×6) (16×6) (24×6)
Cable diameter, mm 5.6 6.0 5.8 6.2 6.7 7.3 7.9 8.7 8.9 9.7 11.2
Cable weight, kg/km 30.5 33.8 32.7 35.9 40.9 46.1 52.0 62.0 63.0 73.1 91.8
Min bending radius, mm 56 60 58 62 67 73 79 87 89 97 112

Operation parameters
FTTH-Distribution

Distribution with Micro Tubes

-10°С…+50°С (Tight-Buffered Distribution for Indoor Installation,


Distribution with Micro Tubes)
Operation temperature range
-40°С…+60°С (Tight-Buffered Distribution for Outdoor Installation,
Distribution with Micro Tubes)
Installation temperature range -10°С…+50°С
Transportation and storage temperature range -60°С…+70°С
Min bending radius 10x cable diameter
Life time 25 years

* Operation temperature range can be increased on request.


Different combinations of fiber counts and loose tubes in a cable are available on request.

110
Distribution «Butterfly»
(up to 8 fibers)
APPLICATION:

Applied for installation inside buildings (including vertical installation), in


Applied for installation in duct, tubes, blocks, for blowing-in in protecting
trays, channels, for installation on outer sides of the buildings
polyethylene tubes

Perfect solution for optical All-dielectric


networks inside buildings construction
2

3 1

FTTH-Distribution
Easy to terminate and install –
easiest access to fibers High flexibility

Flame-retardant UV-resistant

CONSTRUCTION:
1. Optical fiber.
Lower cost compared to Allowable tensile
2. Fiberglass rods.
Distribution Cables strength up to 80 N
3. Halogen free flame-retardant jacket.

Minimum size and weight


High crush resistance for the cable with 8 fibers

111
Features
Distribution «Butterfly»

Allowable tensile strength — 80N — operation; 150 N — installation


Crush — from 250 N/сm
Fiber count up to 4 up to 8
Cable dimension, mm 2×3 2.1 × 3.2
Cable weight, kg/km 9.1 10.2
Min bending radius, mm 15 15

Operation parameters
Distribution «Butterfly»

Operation temperature range -40°С…+70°С


Installation temperature range -10°С…+50°С
FTTH-Distribution

Transportation and storage temperature range -60°С…+70°С


Min bending radius 10x cable diameter
Life time 25 years

* Operation temperature range can be increased on request.

112
FTTH-Subscribers
Tight-Buffered Simplex
APPLICATION:

Applied inside buildings, in trays, cable channels, in duct, tubes


and blocks. It is also applied on outer sides of buildings and for patch
cords manufacturing

Perfect solution for All-dielectric


patch cords manufacturing construction
4 3 2 1

Compact and flexible UV-resistant

FTTH-Subscribers
Cable can be terminated
CONSTRUCTION: Flame-retardant with a standard
connector
1. Optical fiber.
2. Tight-buffer.
3. Aramid yarns.
4. Halogen free flame-retardant jacket. Resistance to crushing Allowable tensile strength
loads up to 50 N/сm up to 180 N

113
Features
Tight-Buffered Simplex

Allowable tensile strength — 180 N


Crush — from 50 N/сm
Fiber count 1 1
Cable dimension, mm 1.8 2.8
Cable weight, kg/km 3.5 7.2
Min bending radius, mm 18 28

Operation parameters
Tight-Buffered Simplex

Operation temperature range -10°С…+50°С*


Installation temperature range -10°С…+50°С
Transportation and storage temperature range -50°С…+50°С
Min bending radius 10x cable diameter
FTTH-Subscribers

Life time 25 years

* Operation temperature range can be increased on request.

114
Tight-Buffered Duplex
APPLICATION:

Applied for installation inside buildings, in trays, channels, for patch cords
manufacturing

Perfect solution for All-dielectric


patch cords manufacturing construction

4 3 2 1 Compact and flexible UV-resistant

Cable can be terminated

FTTH-Subscribers
Flame-retardant with a standard
connector
CONSTRUCTION:
1. Optical fiber.
2. Tight-buffer.
3. Aramid yarns. Resistance to crushing Allowable tensile strength
loads up to 50 N/сm up to 180 N
4. Halogen free flame-retardant jacket.

115
Features
Tight-Buffered Duplex

Allowable tensile strength — 180 N


Crush — from 50 N/сm
Fiber count 2
Cable dimension, mm 2.8 × 5.6
Cable weight, kg/km 14.4
Min bending radius, mm 28

Operation parameters
Tight-Buffered Duplex

Operation temperature range -10°С…+50°С *


Installation temperature range -10°С…+50°С
Transportation and storage temperature range -50°С…+50°С
Min bending radius 10x cable diameter
FTTH-Subscribers

Life time 25 years

* Operation temperature range can be increased on request.

116
FTTH «Butterfly»
APPLICATION:

Applied inside buildings, in trays, cable channels, in duct, tubes


and blocks.

Perfect solution as a cable All-dielectric


guided to the customer’s construction
2 home or office

3 1
Easy to terminate and install – Lower cost compared to
easiest access to fibers Duplex Cables

Flame-retardant UV-resistant

FTTH-Subscribers
CONSTRUCTION:
1. Optical fiber. Operation temperature Allowable tensile
2. Fiberglass rods. down to -40 C strength up to 80 N
3. Halogen free flame-retardant jacket.

High crush resistance

117
Features
FTTH «Butterfly»

Allowable tensile strength — 80N — operation; 150 N — installation


Crush — from 250 N/сm
Fiber count up to 8
Cable dimension, mm 2.1 × 3.2
Cable weight, kg/km 4.2
Min bending radius, mm 15

Operation parameters
FTTH «Butterfly»

Operation temperature range -40°С…+70°С


Installation temperature range * -10°С…+50°С
Transportation and storage temperature range -50°С…+50°С
Min bending radius 10x cable diameter
FTTH-Subscribers

Life time 25 years

* Operation temperature range can be increased on request.

118
HTTP–Drop
Flat Type Drop Reinforced
APPLICATION:

Applied for aerial installation on transmission towers,


Applied for installation inside buildings,
lamp posts, between buildings and constructions
in trays, in ducts, on outer sides of buildings

All-dielectric Suitable for aerial


3 construction 100 installation up to 100 m

4 2 1

Operation temperature Allowable tensile


range down to -60C strength up to 3 kN

Exceedingly high crush


resistance
CONSTRUCTION:
1. Optical fiber.

HTTP-Drop
2. Loose tube.
3. Fiberglass rods.
4. Jacket.

119
Features
Flat Type Drop Reinforced

Crush – from 1.4 kN/сm


Tensile strength, kN 1.3 1.4 1.7 2.2
Fiber count up to 8 up to 12 up to 16 up to 24
Cable diameter, mm 3 × 7.6 3.1 × 8 3.3 × 8.6 3.6 × 9.5
Cable weight, kg/km 27.1 29.5 34.0 41.5

Operation parameters
Flat Type Drop Reinforced

Operation temperature range -60°С…+70°С


Installation temperature range * -30°С…+50°С
Transportation and storage temperature range -60°С…+70°С
Min bending radius 15x cable diameter
Life time 25 years

* Operation temperature range can be increased on request.


HTTP–Drop

120
Round Type Drop
All-dielectric Minimal weight
construction and size

6 5 4 3 2 1 Allowable tensile
Low cost strength up to 1 kN

Resistance to crushing
loads up to 300 N/сm

CONSTRUCTION:
1. Optical fiber.
2. Tight-buffer.
3. Water-blocking yarns.
4. PBT loose tube.
5. Aramid yarns.
6. Jacket.

Features
Round Type Drop

Allowable tensile strength — 1 kN


Crush — from 300 N/сm
Fiber count 1 2

HTTP-Drop
Cable dimension, mm 4.5 5.3
Cable weight, kg/km 20.0 25.1
Min bending radius, mm 45 53

121
Operation parameters
Round Type Drop

Operation temperature range -50°С…+70°С


Installation temperature range * -10°С…+50°С
Transportation and storage temperature range -50°С…+50°С
Min bending radius 10x cable diameters
Life time 25 years

* Operation temperature range can be increased on request.

Round Type Drop (8 Fiber Count)

All-dielectric Minimal weight


4 3 construction and size
2 1

Allowable tensile
Low cost strength up to 2 kN
HTTP–Drop

CONSTRUCTION: Resistance to crushing


1. Optical fiber. loads up to 130 N/сm
2. PBT loose tube filled
with water-swellable gel.
3. Aramid yarns.
4. Jacket.

122
Features
Round Type Drop Cable (8 Fiber Count)

Allowable tensile strength — 1 kN


Crush — from 130 N/сm
Fiber count up to 4 up to 8 up to 12 up to 16 up to 24
Cable diameter, mm 4.5 4.6 4.8 5.0 5.3
Cable weight, kg/km 20.5 21.9 23.3 24.9 27.4
Min bending radius, mm 45 46 48 50 53

Allowable tensile strength — 2 kN


Crush — from 130 N/сm
Fiber count up to 4 up to 8 up to 12 up to 16 up to 24
Cable diameter, mm 5.5 5.6 5.8 6.0 6.2
Cable weight, kg/km 31.9 33.4 35.0 36.7 39.3
Min bending radius, mm 55 56 58 60 62

Operation parameters
Round Type Drop Cable (8 Fiber Count)

HTTP-Drop
Operation temperature range * -40°С…+70°С
Installation temperature range -10°С…+50°С
Transportation and storage temperature range -50°С…+50°С
Min bending radius 10x cable diameters
Life time 25 years

* Operation temperature range can be increased on request.

123
124
Semi
Product

125
Semi Product
Steel optical module
APPLICATION:

Used for stationary installation when the optical fiber needs


extra protection from mechanical damages.

2
4 3 1 Up to 48 optical fibers Small size
in a tube

CONSTRUCTION:
1. Optical fiber.
2. Marking thread.
3. Water-blocking gel.
4. Stainless steel tube.

Features
Steel Optical Module

Fiber count 1...48


Product

Outer diameter, mm 1.1...7


Semi

Inner diameter, mm 0.8...6.2


Module wall thickness, mm 0.15; 0.2; 0.4
Optical fiber excessive length, % 0...0.8
Steel Module Material stainless steel 1.4301, 1.4404

126
Reinforced steel
optical module
APPLICATION:
Designed to monitor physical parameters as a separate sensor Recommended for installation in tunnels, roads, runways and for other
cable or as part of logging and downhole cables, high-voltage industrial applications that require high mechanical strength combined
power cables with temperature resistance and fast response times.

2 Up to 48 optical The unique combination of a


fibers in a tube small diameter and a weight
4 3 1
with extremely high strength
characteristics

CONSTRUCTION:
1. Optical fiber.
2. Marking thread.
3. Stainless steel tube filled with water-blocking gel.
4. Stainless steel tube.

Features
Reinforced Steel Optical Module

Fiber count 1…48

Product
Outer diameter, mm 2.4…4

Semi
Module wall thickness, mm 0.4
Optical fiber excessive length, % 0...0.8
Steel Module Material stainless steel 1.4301

127
Operation parameters
of stainless steel tubes
Operation temperature range* -60°С…+70°С
Installation temperature range -30°С…+50°С
Transportation and storage temperature range -60°С…+70°С
Min bending radius not less 25x cable diameter
Life time 25 years

* Operation temperature range can be changed on request.

Clad wire
APPLICATION:

Used as part of products, that require high corrosion-resistance:


ground wires, conductors, wire ropes and others.

1 Aluminum-clad steel wire


2
eliminates corrosion
Product

CONSTRUCTION:
Semi

1. Stainless steel wire.


2. A layer of aluminium.

Upon Customer request, we are able to offer corrosion-resistant products based on aluminium-clad steel wire.

128
Maximum
Wire Wire outer Minimum tensile Load at 1% Conductivity,
resistance
label diameter, mm strength, MPa elongation, MPa % IACS
at 200C, nom•m
1.80...3.25 1340 1200
3.25...3.45 1310 1180
3.45...3.65 1270 1140
3.65...3.95 1250 1100
20SA
3.95...4.10 1210 1100
Type A
4.10...4.40 1180 1070 84.80 20.3
4.40...4.60 1140 1030
4.60...4.75 1100 1000
4.75...5.50 1070 1000
20SA
1.80...5.50 1320 1100
Тип B
27SA 2.50...5.00 1080 800 63.86 27
30SA 2.50...5.00 880 650 57.47 30
40SA 2.80...5.00 680 500 43.10 40

Operation parameters Clad wire


Maximum short-term heating temperature of the wire not more than 200 °C
Service life 45 years

Product
* Upon Customer request, the temperature range may be expanded.

Semi
129
InGround Superlight Micro
APPLICATION:

May be installed between buildings and constructions, in cable


Used as a temporary cable section during repair works. ducts in case of danger of damage by rodents, in trays, tunnels,
bridges and overhead roads, in conduits and inside buildings.

Cost effective Reduced weight


5 4 3 2 1 design and size

Armor is a reliable protection Highest resistance to crush-


against strong mechanical ing loads — from 0.7 kN/cm
damage

CONSTRUCTION:
1. Optical fiber. 4. High-strength armor of zinc-coated
2. PBT optical tubes filled with stainless steel wires. Up to 24 fibers — Excellent protection against
water-blocking gel. 5. Polymer jacketing. loose tube design rodents — can be laid in
3. Water-blocking gel. cable duct

Features
InGround Superlight Micro
Allowable tensile strength — 8 kN
Crush — от 0.7 kN/cm
Fiber count Up to 16 Up to 32
Product

Диаметр кабеля, мм 6.2 6.4


Semi

Cable weight 77.6 82.8


Min bending radius 93 96

130
Operation parameters
InGround Superlight Micro
Operation temperature range* -50°С…+70°С
Installation temperature range -30°С…+50°С
Transportation and storage temperature range -60°С…+70°С
Min bending radius not less 15x cable diameter not less 15x cable diameter
Life time 25 years

* Upon Customer request, the temperature range may be expanded.

Product
Semi
131
Knowledge
Base

133
Types and Parameters of Optical Fiber
Corning® SMF-28® Ultra Fiber is used in all Incab cables. Its fiber attenuation is at least 10% lower than that of the other standard
single-mode fibers. It is 10-times more bend-resistant compared to other standard single-mode fibers, and is 100%-compatible with other
single-mode fibers. We normally use Corning optic fibers in our cables, but we can also use fibers of other manufacturers on request.

Single Mode Fiber


Fiber type U-type N-type G.657A1 G.657A2 G.657B3

Corning® Corning ClearCurve


Fiber brand ClearCurve XB ClearCurve LBL
SMF-28® Ultra LEAF ZBL

G.657A1
ITU recommendation G.655 G.657A1 G.657A2/B2 G.657B3
G.652D

DIMENSIONAL SPECIFICATIONS

Core-Clad Concentricity 0.5 0.5 0.5 0.5 0.5

Cladding Diameter 125±0.7 125±0.7 125±1 125±0.7 125±0.7

Cladding Non-Circularity 0.7 0.7 0.7 0.7 0.7

Coating Diameter 242±5 245±5 242±5 242±5 242±5

134
Fiber type У H G.657A1 G.657A2 G.657B3

TRANSMISSION SPECIFICATIONS

Wavelength, nmм 1310...1625 1550 1310…1625 1310…1625 1310…1625

Maximum Attenuation (dB/km):

1310 nm wavelength 0.32 — 0.35 0.35 0.35


1383 nm wavelength 0.32 — 0.35 0.35 0.35
1490 nm wavelength 0.21 — 0.24 0.24 0.24
1550 nm wavelength 0.18 0.22 0.20 0.20 0.20
1625 nm wavelength 0.20 0.24 0.23 0.23 0.23

Dispersion ps/(nm*km)
1310 nm wavelength — — — —
1550 nm wavelength 18 4 18 18 18
1625 nm wavelength 22 10 23 23 23

Polarization Mode Dispersion (PMD),


0.1 0.1 0.1 0.2 0.2
ps/√km

Zero Dispersion 0.092 — 0.089 0.092 0.092

135
Fiber type У H G.657A1 G.657A2 G.657B3

Zero Dispersion Wavelength, nm 1310…1324 — 1304…1324 1304…1324 1304…1324

Cable Cutoff Wavelength, nm 1260 1480 1260 1260 1260

Mode-Field Diameter, (μm)


1310 nm wavelength 9.2±0.4 — 8.6±0.4 8.6±0.4 8.6±0.4
1550 nm wavelength 10.4±0.5 9.6±0.4 9.8±0.5 9.6±0.5 9.65±0.5

Macrobend Loss, dB, λ=1550


nm/1625 nm
(1 turn х ø10,0 mm), dB: 0.5/1.5 — 0.5/1.5 — —
(1 turn х ø7,5mm), dB — — — 0.4/0.8 —
(1 turn х ø5,0 mm), dB — — — — 0.1/0.3
(100 turns х ø 60 mm), dB — 0.05/0.05 — — —

136
Multi-Mode Fiber
Fiber type «М» Type «G» Type
Fiber brand Corning ClearCurve Multimode Corning 62.5/125
ITU recommendation G.651 IEC 60793-2-10

DIMENSIONAL SPECIFICATIONS

Core Diameter 50.0±2.5 62.5±3.0


Core-Clad Concentricity 1,5 3
Cladding Diameter 125±1 125±1
Cladding Non-Circularity 1 2
Coating Diameter 242±5 250±15
TRANSMISSION SPECIFICATIONS
Wavelength, nm 1300 1300
Maximum Attenuation (dB/km)
850 nm wavelength 2.3 3
1300 nm wavelength 0.6 0.7
Numerical Aperture 0.200±0.015 0.275±0.015
Brandwith, MHz
850 nm wavelength 700 200
1300 nm wavelength 500 500
Effective Group Index of Retraction
850 nm wavelength 1.482 1.496
1300 nm wavelength 1.477 1.491

137
Color Identification Chart
24 16 12 8 4 FIBER COUNT IN A LOOSE TUBE
Blue
Orange
Green
Brown
Slate
White
Red
Black
Yellow
Purple
Pink
Turquoise
Blue with ring marks
Orange with ring marks
Green with ring marks
Brown with ring marks
Slate with ring marks
White with ring marks
Red with ring marks
Natural
Yellow with ring marks
Purple with ring marks
Pink with ring marks
Turquoise with ring marks Other colors are available on request.

138
Color Identification
of Loose Tubes

Incab uses the following color indication Basic Tube


of the tubes: blue – basic tube; orange –
guiding tube; others – natural, number is
based on the count from the orange tube.

For double tube design: first tube – blue,


second tube – natural.
For single tube design: tube color – natural. Tube Counting
Direction

Guiding Tube Second Natural

First Natural

139
Transportation.
Maintenance. Installation
TRANSPORTATION: MAINTENANCE:
1. Do not lay drums on the flange. 1. Keep drums protected from external actions, sun,
2. The drums should be fixed. No nailing is allowed while precipitation and dust.
fixing the drums. 2. Do not lay drums on the flange.
3. The truck should have a wooden floor. 3. Storage temperature range is from -60 °С…+70 °С.

INSTALLATION GUIDES:
1. The cables are meant for hand and mechanic installation.
2. Cable termination and installation should be done in ways and
with instruments that eliminate the danger of cable damage.
3. Basic requirements:
Length of cable axial torsion at an angle ±360° ≥4 m
Admissible static bending radius for duct cables ≥250 mm
Admissible static bending radius of loose tube ≥20х cable diameter

Bending radius for transportation, maintenance


≥20х cable diameter
and installation

Length of cable axial torsion at an angle ±360° ≥4 m

Admissible static bending radius for duct cables ≥250 mm

Admissible static bending radius of loose tube ≥20х cable diameter

Admissible installation bending radius of optical fiber ≥3 mm (within 10 minutes)

140
Drum Sizes
Dimensions, mm Drum weight
Drum Type including
A B C D E sheathing, kg
4 400 370 162 305 80 5
5 500 560 320 500 80 9
6 600 560 320 500 80 10
8b 800 646 450 500 70 50
10 1000 646 545 500 70 95
12 1220 650 650 500 70 125
12а 1220 864 650 710 70 145
14 1400 875 750 710 70 198
14g 1400 1065 750 900 70 206
16а 1600 970 800 800 80 273
17а 1700 1094 900 900 80 330
17mod 1700 1294 900 1100 80 440
18а 1800 1120 900 900 80 400
18mod 1800 1320 900 1100 80 500
18u 1800 1230 1000 1000 80 650

B
D
E

С
A

141
Drum Capacity
Cable
Cable Length on a Drum, m
Diameter,
mm 4 5 6
2.0 5190 8840 17 670
2.5 3320 5660 11 310
3.0 2300 3930 7850
3.5 1690 2890 5770
4.0 1300 2210 4420
4.5 1020 1750 3490
5.0 830 1410 2830
5.5 1170 2340

Cable
Cable Length on a Drum, m
Diameter,
mm 8b 10 12 12а 14 14g 16а 17а 17mod 18а 18mod 18u
6.0 2820 5030 7730 10 970 15 710 19 910 25 280 30 910 37 780 36 740 44 900 37 070
6.5 2400 4290 6580 9350 13 390 16 970 21 540 26 340 32 190 31 300 38 260 31 600
7.0 2070 3700 5680 8060 11 540 14 630 18 570 22 710 27 760 26 990 32 990 27 250
7.5 1810 3220 4950 7020 10 050 12 750 16 180 19 780 24 180 23 510 28 740 23 740
8.0 1590 2830 4350 6170 8840 11 200 14 220 17 390 21 250 20 670 25 260 20 840
8.5 1410 2510 3850 5470 7830 9920 12 590 15 400 18 820 18 310 22 370 18 480
9.0 1250 2240 3430 4880 6980 8850 11 230 13 740 16 790 16 330 19 960 16 490
9.5 1130 2010 3080 4380 6270 7940 10 080 12 330 15 070 14 650 17 910 14 800
10.0 1020 1810 2780 3950 5660 7170 9100 11 130 13 600 13 230 16 160 13 350
10.5 920 1640 2520 3580 5130 6500 8250 10 090 12 340 12 000 14 660 12 110

142
Cable
Cable Length on a Drum, m
Diameter,
mm 8b 10 12 12а 14 14g 16а 17а 17mod 18а 18mod 18u
11.0 840 1500 2300 3260 4670 5920 7520 9200 11 240 10 930 13 360 11 040
11.5 1370 2100 2990 4280 5420 6880 8410 10 280 10 000 12 220 10 100
12.0 1260 1930 2740 3930 4980 6320 7730 9440 9180 11 230 9270
12.5 1160 1780 2530 3620 4590 5820 7120 8700 8460 10 350 8550
13.0 1070 1650 2340 3350 4240 5380 6580 8050 7830 9560 7900
13.5 990 1530 2170 3100 3930 4990 6110 7460 7260 8870 7330
14.0 1420 2020 2890 3660 4640 5680 6940 6750 8250 6810
14.5 1320 1880 2690 3410 4330 5290 6470 6290 7690 6350
15.0 1240 1760 2510 3190 4040 4950 6040 5880 7180 5930
15.5 1160 1640 2350 2980 3790 4630 5660 5500 6730 5560
16.0 1090 1540 2210 2800 3550 4350 5310 5170 6310 5220
16.5 2080 2630 3340 4090 5000 4860 5940 4900
17.0 1960 2480 3150 3850 4710 4580 5590 4620
17.5 1850 2340 2970 3630 4440 4320 5280 4360
18.0 1750 2210 2810 3430 4200 4080 4990 4120
18.5 1650 2090 2660 3250 3970 3860 4720 3900
19.0 2520 3080 3770 3660 4480 3700
19.5 2390 2930 3580 3480 4250 3510
20.0 2270 2780 3400 3310 4040 3340
20.5 2650 3240 3150 3850 3180
21.0 2520 3080 3000 3670 3030
21.5 2410 2940 2860 3500 2890
22.0 2300 2810 2730 3340 2760

To calculate reel (drum) capacity for InAir Figure 8 cable and for Flat Drop Cable, use equivalent cable diameter.

143
Contacts
Incab Ltd.,
106, 25th October st., Perm, Russia
tel./fax + 7 (342) 211-41-41, 240-07-40
export@incab.ru
incab.co

144
FOR CLEVER IDEAS: