You are on page 1of 1

12 11 10 9 8 7 6 5 4 3 2 1

H H
General Notes:

1. DIMENSIONS ARE IN mm.


2. NO DIMENSION ARE TO BE SCALED FROM THIS DRAWING.
3. VENDOR MUST MAKE AT LEASE TWO SAMPLE STRUCTURE
COLUMN RAFTER L-CLIT TO VERIFY ALL DIMENSIONS AT SITE BEFORE COMMENCING
G OF WORK. G
25 30 4. GRADE OF STEEL - YST-250 MPa GRADE-A-U.S.T- 411 MPa
(MIN) EI-23% MIN B.I.S - 2062.
90 70 30 1021 30 70 5. ALL ELECTRODE RODE AND GRADE MUST BE AS PER B.I.S
110 55 CODE.
90 130 6. ALL BASE PLATE CONNECTION TO BE BUTT & WELL
25 Ø10 Ø10 PENETRATE, MUST BE AS PER B.I.S CODE.
Ø14 7. FABRICATED STRUCTURE SHOULD BE HOT DIPPED
130 GALVANIZED AS PER IS CODE 2629-1965 OR LATEST.
8. MATERIAL FINISH GALVANIZED AS/BIS CODE - 4759.
13.7 9. Z-LIP AND L-CLIP ARE COLD FORM SECTION AND ALL OTHER
578.4 628.9 ARE HOT ROLLED.
50
F 36.8 F
40 40 50.0
110 20
35.7 40 30 35 40
Ø10 NOTES
30
18 Ø10 40 1. ALL WELDING JOINT SHOULD BE THOROUGHLY CHECKED
40 1221 AS/B.I.S CODE BY QUALITY CONTROLLER.
Ø10 110 2. ALL WELDER SHOULD QUALIFIED AS/B.I.S CODE MUST
CHECKED BY QUALITY CONTROLLER.
780 50 3. ALL WELD SHOULD BE FRACTURE FREE MUST BE CHECKED
BY QUALITY CONTROLLER.
E 4. ALL MATERIAL QUALITY AND GRADE MUST BE CHECKED BY E
QUALITY CONTROLLER.
PART 3 :- L 80X73 5. HOLE CLEARANCE FOR METRIC BOLT AS PER B.I.S CODE
1821-1967.
86 THK: 3mm
PART 2 :- C 110X50X20 6. HOT DIP GALVANIZED MIN:-90 MICRONS (BIS CODE - 4759).

THK : 2 mm

PART 1 :- C 80X45X15 982 mm


THK : 3 mm 946.4 mm D
D

PURLIN

21.8 946.4 55.6 946.4 55.6 946.4 55.6 946.4 55.6 946.4 55.6 946.4 21.8
C 22.5 1176 C
Ø10
1955 mm

INSTALLATION
636.5 40 2256 40 2256 40 731.5 45 HOLES

80
15
40
Ø10
B

6000 DRAWN
NS
45 DESIGN CLIENT:- MR. ANIRUDH GUPTA
NS
CHECKED SITE:- 31, ASHOKA AVENUE,
PART 4 :- C 80X45X15 SAINIK FARMS
A
THK : 2mm APPROVED SINGLE PORTRAIT STRUCTURE A

KK PART DRAWINGS
DRG. NO. REV. SCALE DATE
SE/EPC/E.I.L-01 R01. NTS 16/06/2017
12 11 10 9 8 7 6 5 3 2 1