You are on page 1of 1

Overview

Integrated Turbine Systems recognises that operators of


turbines and associated driven equipment frequently encounter
operational challenges. These include little or no access to
product technical support, incompatibility with more modern
systems, component obsolescence leading to reduced
availability, poor reliability, and limited or restricted operation
resulting in increased operating costs.

We have experience of designing and implementing control


systems modernisations and life-extension upgrades for
customers around the world, increasing availability and reliability
while simplifying operation and reducing maintenance costs

Our retrofits and upgrades experience extends over a variety of Ancillary System Upgrades
manufacturer’s and different types of rotating equipment. Our
solutions can be tailored to the individual needs of the customer, We are able to provide fully engineered replacement modules
ranging from minor module replacements to major control and ancillary systems to completely upgrade the installed
retrofits for both prime mover, driven equipment and ancillary electrical equipment. Typical upgrades include:
systems.
 Governor, turbine sequencer and temperature monitoring
Control System Upgrades systems
 Vibration and condition monitoring systems
When mature control systems are still operating with the as  Starting systems
supplied original equipment, or consist of various upgrades and  AC and DC motor control suites
modifications, they can reach the stage where they cannot be  Batteries and inverter/charger systems
reliably supported. We can address and overcome these issues by  Fire and gas monitoring systems with or without suppression
supplying a modern and cost effective engineering solutions to systems
suit our customer requirements.  Generator protection and voltage regulator systems
 Compressor performance and anti-surge systems
Such a retrofit solution offers the following benefits:  Process plant control and supervision systems
 DCS or SCADA systems
 System designed using off the shelf industrial components,
reducing inventory and improving parts availability Fuel System Upgrades
 Ability to provide tested software enhancements prior to site
installation as the logic is no longer ‘hard wired’ We provide fuel system upgrades, which can be implemented
 Improved operator interface with intuitive HMI touch-screen independently from other upgrades. This can offer the following
displays benefits:
 Enhanced data acquisition incorporating data logging, trend-
ing and condition monitoring.  Improved starting reliability
 Integration with existing and new DCS and SCADA systems  Reduced complexity and component count
 Remote control and monitoring options  Greater flexibility with variable fuel quality and availability
 Controlled levels of maintenance and operating parameter  Improved load acceptance/rejection ability
access  Fully calibrated fuel metering
 Incorporation of current design standard such as SIL 2  Continuous monitoring of fuel consumption
 Technical and customer support including training
V Jan 17

Contact Us Visit Us Follow Us


T: +44 (0)1522 503300 Integrated Turbine Systems Ltd Integrated Turbine Systems
F: +44 (0)1522 503351 New Horizons
E: sales@turbinesystems.co.uk Teal Park Road @turbinesystems
W: www.integratedturbinesystems.com Lincoln
LN6 3AD Integrated Turbine Systems
United Kingdom

You might also like