You are on page 1of 12

NVLAP Lab Code 201056-0

TEST REPORT
Report Reference No. ...................... : 4333105.56
Tested by (name + signature) ......... : Fair Deng
…………………………
Approved by (name + signature) .... : Jason Zhang
…………………………
Date of issue ................................... : 2016-12-26
Testing Laboratory ....................... : DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou
Branch
Testing location / address ............... : Building A3, No. 3 Qiyun Road, Science City, Guangzhou Hi-
Tech Industrial Development Zone, Guangzhou, P. R. China
Applicant ........................................ :
Customer ........................................ Osram Asia Pacific Management Company ShenZhen Branch
Address ........................................... : 2F, Block B, Jianxing Building, No.3151, Shahe West Road,
Xili, Nanshan District, Shenzhen, 518055, P. R. China
Test specification :
Standard Reference ........................ : LM-79-08
Test object description ................ : LED Luminaire
Trade Mark ..................................... : OSRAM
Manufacturer ................................... : Same as applicant
Factory ............................................ Same as applicant
Model/Type reference ..................... : LEDENVO LED ST 60W 757 VS1 OSRAM
Ratings ............................................ : 220-240 Vac, 50/60 Hz, 60 W, Class I

Test item particulars :


Lamp type ....................................... : LED package
LED Packages/Modules type .......... : NF2x757GR-E
LED Packages/Modules number 72
LED Package/Modules supplier ...... : Nichia
Number of test objects ................ : 1 sample

Testing Date 2016-11-14 to 2016-12-02


General remarks

This report shall not be used by the client to claim product endorsement by NVLAP, NIST or any
agency of the US government.
Page 2 of 12 Report No.: 4333105.56

Testing Summary

1. Integrating sphere Test


2. Goniophotometer Test

TEST METHOD

1.1 Seasoning in Sample Orientation - LED Products


No Seasoning was performed in accordance with IESNA LM-79-08

1.2 Light Output and Light Distribution Measurements


Light Output and Light Distribution were measured using a Everfine Go-R5000
Goniophotometer. The lamp rotates only around the fixed vertical axle in the prescribed
burning position and a reflecting mirror rotates around the horizontal axle, meanwhile,
the mirror in the opposite side reflect the measured beam perpendicularly towards to a
fixed detector at the horizontal rotation axis. The combined motion of the lamp and
mirror permit the measurement of luminous intensity at the direction of any horizontal or
vertical angle without tilting the lamp. The lamp was allowed to stabilize before
measurements were made. The calibration of the Goniophotometer system is by the
reference/standard lamps which are traceable to NIM.

Electrical measurements including voltage, current, power and power factor were
measured using the Everfine Model PF2010A.

1.3 Color Performance


Color Performance was measured using an Everfine 2 m Integrating Sphere Unit at the
ambient temperature of 25ºC ± 1ºC. Temperature was measured at the same height as
the sample inside the sphere.

Correlated color temperature and color rendering index was measured using an Everfine
Model PMS-80 Spectrophotocolorimeter attached to the detector port of the integrating
sphere and it was calculated from the spectral radiant flux measurements taken over the
range 380 to 780 nm. The calibration of the integrating sphere spectrometer system is
by the reference/standard luminaires which are traceable to NIM.
Electrical measurements including voltage, current, power and power factor were
measured using the Everfine Model PF2010A.

Self-absorption factor of integrating sphere was considered during the testing.


Page 3 of 12 Report No.: 4333105.56

Equipment List

Last
Calibration
Equipment name TYPE Manufacturer Calibration
Due Date
Date

Digital Power Meter PF2010A EVERFINE 2016-Aug 2017-Aug

AC power source DPS1060 EVERFINE 2016-Aug 2017-Aug

Digital Power Meter PF2010A EVERFINE 2016-Aug 2017-Aug

GO-R5000-
Goniophotometers EVERFINE 2016-Aug 2017-Aug
SML

Goniophotometer controller CT400 EVERFINE 2016-Aug 2017-Aug

High-accuracy digital photometer


ID-1000 EVERFINE 2016-Aug 2017-Aug
head(f1&f2)
High-accuracy digital photometer
ID-1000 EVERFINE 2016-Aug 2017-Aug
head(f1)

High accuracy array spectroradiometer HAAS-2000 EVERFINE 2016-Aug 2017-Aug

Standard light source D908 EVERFINE 2016-Sep 2017-Sep

Digital CC&CV DC power supply WY12010 EVERFINE 2016-Aug 2017-Aug

Digital power meter WT210 YOKOGAWA 2016-Apr 2017-Apr

Digital power meter PF2010A EVERFINE 2016-Apr 2017-Apr

Digital CC&CV DC power supply WY305 EVERFINE 2016-Apr 2017-Apr

Intelligent Pure Sine-wave Power Supply TPS-500B EVERFINE 2016-Apr 2017-Apr

Integrating sphere 2m EVERFINE 2016-Jan 2017-Jan

Plus UV-VIS-Near IR spectrophoto


PMS-80 EVERFINE 2016-Jan 2017-Jan
colorimeter

Standard Light Source D204 EVERFINE 2016-Sep 2017-Sep

Standard Light Source D204C EVERFINE 2016-Sep 2017-Sep


Page 4 of 12 Report No.: 4333105.56

1. Integrating Sphere Test

Environmental Condition:
Temperature 24,5°C
:

Test Result:

Voltage Frequency Current Power Power Stabilization


Sample ID
(V ac) (Hz) (A) Factor (W) time (min)
007 230,1 50 0,260 0,959 57,44 50

Sample ID CCT
Ra
(K)
007 5826 76,5

Orientation of installation: Downward Light


Operation time: 70 min
Page 5 of 12 Report No.: 4333105.56

2.Goniophotometer Test

Environmental Condition:
Temperature 24,7°C
:
Test Result:

Voltage Frequency Current Power Power Stabilization


Sample ID
(V ac) (Hz) (A) Factor (W) time (min)
007 230,2 50 0,262 0,960 57,90 50

Downward Upward Luminous


Sample ID Flux Operation
Street House Street House Efficacy
(lm) time (min)
side (%) side (%) side (%) side (%) (lm/W)
007 7573,3 49,7 50,3 0 0 130,79 140

Orientation of installation:

Roadway Summary
Cutoff Classification: FULL CUTOFF
Distribution: TYPE I, SHORT
Max Cd, 90 Deg Vert: 0
Max Cd, 80 to <90 Deg: 289,0
Max Candela: 3210,8 cd
@ C: 250°, γ: 63°
Page 6 of 12 Report No.: 4333105.56

Light Distribution

Polar Candela Distribution Diagram

Max Intensity Cone Surface Distribution Diagram


Page 7 of 12 Report No.: 4333105.56

ISO Lux Diagram

Coefficient of Utilization Curve


Page 8 of 12 Report No.: 4333105.56

Luminous Intensity Distribution Data


Page 9 of 12 Report No.: 4333105.56
Page 10 of 12 Report No.: 4333105.56
Page 11 of 12 Report No.: 4333105.56
Page 12 of 12 Report No.: 4333105.56

Sample Photo

Overview

Overview

-END-