Professional Documents
Culture Documents
TEST REPORT
Report Reference No. ...................... : 4333105.56
Tested by (name + signature) ......... : Fair Deng
…………………………
Approved by (name + signature) .... : Jason Zhang
…………………………
Date of issue ................................... : 2016-12-26
Testing Laboratory ....................... : DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou
Branch
Testing location / address ............... : Building A3, No. 3 Qiyun Road, Science City, Guangzhou Hi-
Tech Industrial Development Zone, Guangzhou, P. R. China
Applicant ........................................ :
Customer ........................................ Osram Asia Pacific Management Company ShenZhen Branch
Address ........................................... : 2F, Block B, Jianxing Building, No.3151, Shahe West Road,
Xili, Nanshan District, Shenzhen, 518055, P. R. China
Test specification :
Standard Reference ........................ : LM-79-08
Test object description ................ : LED Luminaire
Trade Mark ..................................... : OSRAM
Manufacturer ................................... : Same as applicant
Factory ............................................ Same as applicant
Model/Type reference ..................... : LEDENVO LED ST 60W 757 VS1 OSRAM
Ratings ............................................ : 220-240 Vac, 50/60 Hz, 60 W, Class I
This report shall not be used by the client to claim product endorsement by NVLAP, NIST or any
agency of the US government.
Page 2 of 12 Report No.: 4333105.56
Testing Summary
TEST METHOD
Electrical measurements including voltage, current, power and power factor were
measured using the Everfine Model PF2010A.
Correlated color temperature and color rendering index was measured using an Everfine
Model PMS-80 Spectrophotocolorimeter attached to the detector port of the integrating
sphere and it was calculated from the spectral radiant flux measurements taken over the
range 380 to 780 nm. The calibration of the integrating sphere spectrometer system is
by the reference/standard luminaires which are traceable to NIM.
Electrical measurements including voltage, current, power and power factor were
measured using the Everfine Model PF2010A.
Equipment List
Last
Calibration
Equipment name TYPE Manufacturer Calibration
Due Date
Date
GO-R5000-
Goniophotometers EVERFINE 2016-Aug 2017-Aug
SML
Environmental Condition:
Temperature 24,5°C
:
Test Result:
Sample ID CCT
Ra
(K)
007 5826 76,5
2.Goniophotometer Test
Environmental Condition:
Temperature 24,7°C
:
Test Result:
Orientation of installation:
Roadway Summary
Cutoff Classification: FULL CUTOFF
Distribution: TYPE I, SHORT
Max Cd, 90 Deg Vert: 0
Max Cd, 80 to <90 Deg: 289,0
Max Candela: 3210,8 cd
@ C: 250°, γ: 63°
Page 6 of 12 Report No.: 4333105.56
Light Distribution
Sample Photo
Overview
Overview