You are on page 1of 100

User's Manual for MK3XX V1.

0 Preface

Welcome to use Our Injection Molding Machine Control System

Safety Cautions

(Please read it before installation)

1. When the exterior power supply is abnormal or the control system


breaks down, make sure the safety circuit is installed outside the
control system in order to make the entire system work safely.
2. When abnormal situations occur, such as the control system unable
to test the input/output, the output can not be controlled; in order to
Danger
make the machine opera te safety , for the output sign al related to majo r
accid ent, please design the exterior safety circu it or protection device.
3. The emergency door safety device is the core safety part of the
injection molding machine. Make sure related safety protection
devices for machine and oil line are added outside.

1. Others except the trained and qualified professional technicans


are not allowed to install and maintain this system.
Cautions 2. When a valuable or large die is used, the travel control method
must be adopted to use the neutron; otherwise, the control system
can not guarantee the safety of the die.

R
PORCHESON

User's Manual for MK3XX V1.0 Preface

Statement

Please read the manual carefully before you use this


syst em. PORCHESON Company will only be resp onsible
for the maintenance of the problems exist in the system
itself, and will not be responsible for the fault caused by
improper operat ion, unauthorized maintenance,natural
disasters, or the system damage or data loss caused by
other abnormal situations. The changes in the manual will
not be informed in advance. The contents in the manual
are for reference,the company will not be responsible.
for the losses caused by the misunderstanding of the
manual.There may be differences between the actual
objects and the abstract image,but the functions are
Consistent.
According to the Copyright Law, the Company owns
and ret ains the exclusive ownersh ip of all works,without
The writte n approval of the Company,any deletio n revision,
reproduction or imitation of the manual are not perm itted.

R
PORCHESON
II
User's Manual for MK3XX V1.0 Preface

System Configuration &


Installation 1

Line of MK3XX Button Operation specification


5
Operator's Manual

Explanation of the Parameter/


Function Setting 14

Production management 46

Explanation of the System


Debugging and Setting 58

Input/output State Detection 76

Reference & Appendices 81

All copyrights are reserved, any duplication without the prior authorization
shall be forbidden.
R
PORCHESON
III
User's Manual for MK3XX V1.0 Contents

Contents
Chapter 1 System Configuration & Installation
1. System Configuration & Remarks p1
2. Features of the MC800AM Control System p1
3. Installation and Debugging of Computer Control System p2
Chapter 2 Specifications of the Button-Pressed Operations
1. Figure of Keyboard of the Operation Panel (See the figure below) p5
2. Explanation of the Functional Keys p6
3. Explanation of the Parameter Setting button p8
4. Cursor Key p9
5.Operation Mode Selection Key p9
6. Electrothermal ON/OFF key and Motor ON/OFF key p9
7. Manual Operation Keys p10
8. Setting Scope of Numeric Items p13
Chapter 3: Descriptions on setting parameters/functions
1. The main control panel shown while turning on p14
2 . The descriptions on display P15
3 . Descriptions on alarm mode P16
4 . Descriptions on operation/prompt mode P17
5 Setting for celerity information P18
6 Setting for mold close information p19
7. Set mold open information p20
8. Set the plastic injector information p21
9. Set the hold pressure information p22
10. The feed/suck back/cooling information p23
11. Set the auto clear setup information p24
12. Set the nozzle information p25
13. Set the mold adjusting information p26
14. Set the ejector forward information p27
15. Set core AB information p28
16. Set core CD information p29
17. Set blowing information p30
18. Set time/count information p31
19. Set temperature information p32
20. Hot runner temp setup information information P33
21. Set warm-up information P34
22. Set mold data information P35
23. Set Amendment history information P37
24. Set special parameters information P38
25. Set Ethernet information P39
26. Set MES-Injection Workshop Management system (Optional ) P43

R
PORCHESON
IV
User's Manual for MK3XX V1.0 Contents

Chapter 4 production management


1. Set porduction Imformation p46
2. The output statistics iformation p47
3. SPC Track recoda Page p48
4. The Incident track back page p49
5. The injection curve page p50
6. The servo -real time curve page p51
7. The History curve page of servo page p52
8.the temperature tracking curve page p53
9. the temperature monitor page p54
10. the injcetion speed curve page p55
11. USB setting page (for options) p56
Chapter 5 Instructions for the System Commissioning Settings
1. Engineer Setting Page p58
2. Delay Setting Page p59
3. Pressure/Flux Slope Setting Page p60
4. Pressure Pre-Adjustment Page p61
5. Flux Pre-Adjustment Page p62
6. Back Pressure Pre-Adjustment Page p63
7. Electronic Ruler/ Pressure Setting Inspection Page p64
8. Special Function Options Page p65
9. Servo Driver monitor Setup Page p70
10. Servo Driver Setup Page p71
11. Standby Function Setting Page P72
12. Programmable Standby Function Page P73
13. Temperature Parameter Page P74
14. Machine No./ Production-Factory Value Setting Page p75
Chapter 6 Input/Output Mode Inspection
1. Alarm history page p76
2. Input Inspection Page p77
3. Key inspection Page p78
4. Output Inspection Page p79
Reference & Appendices
Appendix 1:MK310 keyboard installation dimension Layout p81
Appendix 2:MK320/330 keyboard installation dimension Layout p82
Appendix 3:MK360 keyboard installation dimension Layout p83
Appendix 4:External dimensions for power supply case and transformer p84
Appendix 5:MC800AM system drawing p85
Appendix 6:MC600AM input and outputWiring Diagram p86
Appendix 7:MC800AM input and outputWiring Diagram p87
Appendix 8:PS660AM input and outputWiring Diagram p88
Appendix 9:PS860AM input and outputWiring Diagram p89
Appendix 10:Motor Electric-Heating Wiring Diagram (for reference only) p90
Appendix 11:Introduction of new type of patent double channel compensation linear sensor p91
Appendix 12:Magnetic suspension displacement sensor p92
Appendix 13:Product selection table p94
Appendix 14:Product Guarantee Terms p95

R
PORCHESON
V
User's Manual for MK3XX V1.0 Chapter 1 System Configuration & Installation

Chapter 1 System Configuration & Installation

1. System Configuration & Remarks


No. Code Content NO Remarks
MC600AM/PS660AM 1 Set
1. Host Computer Optio nal
MC800AM/PS860AM 1 Set
MK310 7.0inch For specifications please 1 Set
refer to appendix 13Model
MK320 7.0inch selection chart 1 Set
2. Keyboard Optio nal
MK330 8.0inch 1 Set
MK360 10.2inch 1 Set
3. Power pack PW350 350W/450W 1 Set
4. Message cable DB-15F 1To8 meter optional 1 Set

2. Characteristics of MC800AM Control System


The system has bright LCD display
The system adopts two CPU design with fast operating speed, precise control and high stability.
It has the real time function to display time and date in real time.
With 999 groups of mode data storage, it may enter the mode description and real-time
operating help in Chinese and English.
The password setting and data locking can prevent the operators from changing the established
data arbitrarily to influence the quality of products.
There are multiple languages for your choice that display dynamically in real time.
Packing modulus setting function for 8-digit output may set the packing modulus.
Various self-plugging and tein type programs are applicable for the self-plugging and tein
control in different types.
PID with self temperature control has (6+1) sections of temperatures.
Temperature may be preset a week in advance to enable more convenient operation.
Failure Self-detection functions, alarm display and voice prompt
Input and output are done by the optically coupled circuit to isolate the interference of the
external circuitry.
4 -channel of standard D/A output,max current output is 3 A(standard:1A),2 -channel of PWM output.
The output value of pressure, speed, current can have real-time dynamic observation,
and it is not necessary to install another ammeter
8-channel of double-linear scale,8-channel of single linear scale,4-channel of maglev ruler,
4-channel of pressure detection.
Presetting of the voltage and runoff values, proportional valve available for the products in
all brands and better linear proportion.
The management of 255machine production is by a host networking computer ,It canaccurate
Statistics each machine production state and produce data type ,so it is convenient to manage.

R
PORCHESON
1
User's Manual for MK3XX V1.0 Chapter 1 System Configuration & Installation

3. Installation and Debugging of Computer Control System


3.1Cautions upon Installing the Control System
The design of control system is simple and easy, only one 15-core shielding cable connecting
the keyboard and host computer shell with flexible and handy installation and connection. The
sketch map for installation is shown as follows:

Orange Back Yellow Gray


RS232
485B
CGND
485A
+10V
+10V

24VG
+24V

GND
+24V

+24V

24VG
+24V

24VG
0V

CAH
CAL

+ 5 V(3 A)
+ 2 4 V(3 A)

Strong

P1
+ 2 4 V(8 A)

+
RUN

+24V
+ 3 8 V(3 A)

- Control
PW450
X00 front door 1 pressure P Pressure Proportional Valve
0
X01 front door 2 +
1 X02 injector Protective cover Speed S - Speed Proportional Valve
+

eletricity
2 Back pressure Proportional Valve
X03 mold close stop
3 Back pressure F -
4 X04 Electric Eye enter Standby Y 3 3 3

system.

P2
5 X05 feed rotation speed Standby Y 3 2 2
6 X06 before nozzle stop blow female Y 3 1 1

-
7

0
X07 after nozzle stop
XCOM
X10 Standby
blow male Y 3 0

core B out
YCOM
Y27
+
0

7 POWER
1

5
2

6
X11 Standby
X12 Ejector return Fender
X13 Ejecter before stop
X14 Ejector return stop
X15 back door 1
X16 back door 2
core B in
core A out
core A in
mold open buffer
middle pump
big pump
Y26
Y25
Y24
Y23
Y22
Y21
6

2
5

1
Power Equipment
7 X17 motor start fault alarm Y20 0
- XCOM YCOM +
0 X20 fine adjust teeth number high pressure mold close Y17 7
1 X21 front mold adject stop low pressure mold close Y16 6
2 X22 back mold adject stop machine ejector stop Y15 5
3 X23m ech anic hand mold close machine mold open stop Y14 4
4 X24 mechanic hand eject mold thick Y13 3
5 X25 core A in /Count Poor dynamic mold close Y12 2
6 X26 core A out /Count mold thin Y11 1
7 X27 motor fault Ejector return Y10 0
- XCOM YCOM +
0 X30 core B advance /Count Ejector advance Y07 7
1 X31 core B return /Count mold open Y06 6
nozzle return Y05 5
suck back Y04 4
feed Y03 3
2 X32 oil short Injector Y02 2
+ REF+ nozzle advance Y01 1
pressure test

1 AD4 mold close Y00 0


2 AD5
3 AD6
- ADG 220V(L)
2 Mold close
Electronic ruler

2 Inject

oil temperature
+
2

-
Eject
REF+

K6 oil temperature
Fire Wire L 1 2
M oil motor Strong Strong
Motor Electric-Heating Wiring Diagram (for reference only)

+ M 11

Segment5 - K5 Segment5 Y 10 Y
+ 9
Segment4 - K4 Segment4 OIL 8 Lubricate motor
Segment3
Segment2
Segment1
+
+
+
-
-
-
K3

K2

K1
Segment3
Segment2
Segment1
T5
T4
T3
T2
7
6
5
4
HC5
HC4
HC3
HC2
Segment5
Segment4
Segment3
Segment2
Relay board eletricity eletricity
+ T1 3 HC1 Segment1
-
Nozzle +
K0 Nozzle T0 2
zero value N 1
HC0 Nozzle

220V(N) Equipment Equipment


PORCHESON
MC800AM

Ebb eletricity section Strong eletricity section

control box equipment outfit (for reference only)


(1)Upon installing the host control box, adopt the enclosed distribution cabinet at the first choice.
It shall be fixed in the well-ventilized, greaseproof and dustproof conditions equipped with a
fan and dustproof. The distribution box shall be stored under 50degree.
(2)Upon fixing the host computer and power pack, please keep the interconnecting parts such
as all AC connectors and transformers as far away from each other as possible to prevent the
electric wave interference from the electronic grid.
(3)All electric wires and shielding wires shall not be cut off, lengthened or curtailed arbitrarily.
You should use the electric wires and shielding wires provided by this company to prevent
from influencing the reliability and normal operation of the control system.
(4)The shell of flame couple shall adopt the shielding wire. When the outer shielding of all flame
couples adopts the thermal couple reticles, the reticle and machines shall be well grounded and
connected to the ground with the earthing resistance below 4ohm.
(5)Upon wiring, separate the high and low pressure line from the computer control line as much as
possible, do not bind all electrical wires together to prevent the interference from affecting the
reliable operation of control system.
(6)Upon fixing the keyboard and 15-core communication connections of the host computer, you
shall press and tweak with force to prevent the poor connection from affecting the reliable
operation of control system.
(7)Pay special attention to the oil valve outlet public port YCOM, it shall be connected well to prevent
the comput er from inputting while having the phenomenon of oil valve having no motion.

R
PORCHESON
2
User's Manual for MK3XX V1.0 Chapter 1 System Configuration & Installation

3.2Inspection of the Control System


(1)After installation completed, carry out an over all inspection if all connection lines are well
fixed including the switching power supply, host computer shell, electrothermal output line
and the thermal couple of keyboard.
(2)After the line inspection completed, carry out an electric connection inspection. First take
Out the11-digital output line plug of the DC power supply outlet port, namely the power pack
PW450, And then power on to examine and measure if the voltage is the same as the nominal
values and observe if the output indicator on the power pack is normal.
(3)Power off after the measurement completed, insert the DC power supply to input to the plug
of host computer shell. After power-on again for inspection, LCD on the keyboard will display
the normal state of the main page. Revolve on the emergency stop switch to check if the RUN
indicator on the host computer shell turns on. When it turns on, it indicates that the system
can work soundly.
3.3gging of the Control System
(1)After the system having shown normal operating state, press 1 STU button on the monitor
page to adjust color and comparison.

(2)To conduct the parameter setting and memory testing, press button to select a group

输 入
of mod ule numbe rs and then set data in all screens. Press ENTER button to save data. Disconnect
the power and connect it again after a few time, the system will automatically call the data of
mod ule numbe rs saved by you. In case of they are correct, it indicates that the memo ry is all right.
(3)Afterwards, set the data in all relevant data (please see Chapter III Explanation of the Parameter
Setting for the detailed operations). Upon setting in the first time, set the pressure and speed
as little as possible and then after all movements come normally, gradually increase the values
to normal parameters to prevent from damaging the mechanical performances.
(4)After all parameter set, save them and carefully inspect if all input and output points are normal.
Carry out an overall inspection of the alarm system, including the front and back safety doors.
The wire of safety doors shall be connected as stated in the following figure.

Safety Door 1
LS4 LS2
After Saf ety Door 1 After Safety Door 2

After Door

Front Door
Front Saf ety Door 1 Front Safety Door 2
LS3 LS1

R
PORCHESON
3
User's Manual for MK3XX V1.0 Chapter 1 System Configuration & Installation

LS1 LS2 LS3 LS4


XCOM XCOM

X00 X15
Safety Door Wiring Diagram (for reference only)

Safety Door 2

LS4 LS2
After 2 After 1
After Door

Front Door
Fron 2 Fron 1
LS3 LS1

LS1 LS3 LS2 LS4


XCOM XCOM XCOM XCOM

X00 X01 X15 X16

Safety Door Wiring Diagram (for reference only)

★Safety Doors * Special Explanation:


When X00=ON/X15=OFF or X00=OFF/X15=ON closing/opening the doors, or in case of
other abnormal conditions, the system will issue an alarm 2 seconds later for Safety Door
Failure and simultaneously terminate all operating output. In the semi-automatic mode, the
condition for opening/ closing the safety doors is that the time from LS1, LS2, LS3, LS4 all
turn [OFF] to all turn [ON] is more than 0.5 as valid in order to prevent the twitter of safety
door switches from causing error operation.

R
PORCHESON
4
User's Manual for MK3XX V1.0 Chapter 2 Explanation of the Key Operations

Chapter 2 Explanation of the Key Operations


1. Figure of Keyboard on the Operation Panel (See the figure below)

2010-03-28 *Manual* 20:38:08


Nozzle 1Segment 2Segment 3Segment 4Segment 5Segment oil temperature Mold number: 2512
34.2 34.3 34.1 34.1 34.1 34.3 **** G-18CUP
Setup: 50.00 S Operate: 2.14 S Cycle: 216.90 S
Pressure: 20.0 Bar Flux: 20.0 % back pressure: 0.0 Bar
Temperture.OK

2010-03-28 *Manual* 20:38:08


Nozzle 1Segment 2Segment 3Segment 4Segment 5Segment oil temperature Mold number: 2512 33

0
66

7.6 %
99

34.2 34.3 34.1 34.1 34.1 34.3 **** G-18CUP 33

0
66

7.6 %
99

Setup: 50.00 S Operate: 2.14 S Cycle: 216.90 S


Move mold: 593.9 MM Ejector: **** MM estimate production: 0 MM
Pressure: 20.0 Bar Flux: 20.0 % back pressure: 0.0 Bar
Screw: 6.15 MM Screw speed: **** RPM current production: 0 MM
Temperture.OK
Machine Run Well mold close slow

33 66

0 99
7.6 %

33 66

0 99
7.6 %

Move mold: 593.9 MM Ejector: **** MM estimate production: 0 MM


Screw: 6.15 MM Screw speed: **** RPM current production: 0 MM
Machine Run Well mold close slow

R
PORCHESON
5
User's Manual for MK3XX V1.0 Chapter 2 Explanation of the Key Operations

2. Explanation of the Functional Keys

Keys Usage

开锁模
Enter into page for mould opening & mould clamping setting
M.PLT

射 出
Enter into page for ejection & pressure maintaining setting
INJECTION

储 料 Enter into page for feeding, shoot retreat & automatic


FEEDING material clearing setting

座台/调模
Enter into page for seat stand & mould adjustment setting
NOZZ/ADJ.

托模/中子
Enter into page for ejector, self-plugging and huff setting.
EJE/CORE

时 间
Enter into page to set timing and counting.
TIME

温 度
Enter into page for temp pre-heating & temp monitor setting.
TEMP.

资 料
Enter into page for mould ,Datum modification setting
DATUM

快速设定
Enter into pages for celerity one 、 two setting
CELERITY SET

监 视
Return to monitor page at any time.
MONITOR

帮 助
? Enter into real time help page under current status.
HELP

R
PORCHESON
6
User's Manual for MK3XX V1.0 Chapter 2 Explanation of the Key Operations

Keys Usage

PC连接
Enter into page of USB setting
PC LINK

诊 断
Enter into page to set alarm
DIAGNOSE

曲 线
Enter into page to injection, servo temp curve
CURVE

生产管理
Enter into pages to set production data & SPC Tracking
FLOW CHART

MES For entering into MES production management page

This function only limit to panel of Mk360 .


打 印
Current page can be printed on pressing this key.
PRI NT

This function only limit to panel of Mk360 .

When cursor moves to such as the time setup location,1 will be


automatically increased with each pressing on this key.

This function only limit to panel of Mk360 .

When cursor moves to such as the time setup location, 1 will


be automatically reduced with each pressing on this key

This function only limit to panel of Mk360 .

Press this key is equal to move cursor to [Enter] while in log in


status and then press the enter key

This function only limit to panel of Mk360 .

When cursor mov es to such as mou ld name mod ification,


press this key to switch Chinese/English input method

This function only limit to panel of Mk360 .

Press this key is equal to move cursor to [Cancel] while in log in


status and then press the cancel key .

R
PORCHESON
7
User's Manual for MK3XX V1.0 Chapter 2 Explanation of the Key Operations

3. Explanation of the Parameter Setting

7 ABC 8 DEF 9 GHI

0-9 numeric keys are used for data input in the data
4 JKL 5 MNO 6 PQR settingpage. When electric lock is in “OFF”State,
these ten numbers are locked to ensure the data will
not be changed arbitrarily. In the meanwhile, there are

1 2 3
26English letters and special symbols respectively on
STU VWX YZ 0-9 numeric keys used for the input of Chinese and
English letters as well as the machine serial number.
[Delete] key is used to delete the error words during
清 除
0 [ ]/-.
entering the parameters and serial numbers. [Input]
[

CLEAR
key is used to select the functions during function
Selection and used to confirm during item confirmation.

4. Cursor Key

Keys Usage

Skip key, pressing it will skip the cursor to the upper line

Escape key, pressing it will move the cursor to the left

Escape key, pressing it will move the cursor to the right

Skip key, pressing it will skip the cursor to the lower line

R
PORCHESON
8
User's Manual for MK3XX V1.0 Chapter 2 Explanation of the Key Operations

5. Operation Mode Selection Key

Keys Usage Remarks

手 动
Pressing this key will enter the system
into manual state. Ther e is an indi cat or on the left upper
MANUAL
of all keys. Pressing any key will turn
on this indi cat or, indi cat ing the sys tem
半自动 Is in this state. Every time the computer
Pressing this key will enter the system
into semi-automatic operation is started, the default state of system is
SEMI.AUTO anual operation.In case of the temperature
has not reached the set value, the system
电眼自动 is impossible to perform semi-automatic 、
Pressing this key will enter the system senr-automatic and time automatic
into senr-automatic operation operations. The indicator will not turn
SENR.AUTO
on when the semi-automatic、senr-
automatic and time automaticoperat ion
时间自动 key pres sed till thet emperat ure reaches
Pressing this key will enter the system
the set val ue.
into time-automatic operation
TIME.AUTO

电热开/关 马达开/关

6. Electro thermal ON/OFF key HEATER ON/OFF


and Motor ON/OFF key MOTOR ON/OFF

In the manual mode, press the key once and the indicator at the left upper will turn on, indicating
the function state has opened. Pressing the key again and this indicator will turn off, indicating
the function state has shut off. Repeatedly pressing this key, the functions will turn on or off in
turn. Upon the emergency switch stops, the motor will power off swiftly without affecting the
electro thermal operation.

R
PORCHESON
9
User's Manual for MK3XX V1.0 Chapter 2 Explanation of the Key Operations

7. Manual Operation Keys

Keys Usage Operation Conditions

开 模
Mold-opening operations 1. Mold is not reached to the termination position.
MOLD OPEN

锁 模 1.safe door input is normal


2.ejector retreat is in position
Mold-closi ng oper ation 3.mold closing not reached final position
MOLD CLOSE 4.manipulato r sig nal(mold closed)is connected(manipulatr use)

射 出 1.if use time-inject,inject time not reached


2.if use position,not reached inject final position
Injection Operation 3.all sections of temp in charging barrel must within set range
INJECT (no temp alarms)and cool boot for screw timing is up

射 退 1.if E-ru ler not bein g used,suck back time not rea ched
2.if E-ru ler bein g used,not rea ched suck back term ina tion posit ion
Suck back Operation 3.all section s of tem p in charging barre l must within set ran ge
SUCK BACK
(no tem p ala rms)and cool boot for screw timing is up

1. mold open reached termination position


2. core retre at lim it is connected or its tim e is up(core use optio nal)
托模进 3. manipulator signal (ejector)is connected (manipulator
use optional)
Ejector advance operatio n 4. if E-ruler being used,ejector advance position not reached
termination position
EJECT ADV. 5. if E-ruler not being used,1,stroke option is being used,
not reached advance stop pos tion 2,time opt ion is being used,
timing for ejector advance not reached

1. if E-ruler being used,ejector retreat position not reached


托模退
termination position
Eject or return oper ation 2. if E-ruler not being used,1,stroke option is being used,
not reached retreat stop pos tion 2,time opt ion is being used,
EJECT RET. timing for ejector retreat not reached

储 料
1 Feed not reached termination position
Feeding Operation 2 all sections of temp in charging barrel must within set range
(no temp alarms)and cool boot for screw timing is up
CHARGE

自动清料 1 Auto purging being used


2 times of auto purging not completed
Auto purging operation 3 all sections of temp in charging barrel must within set range
AUTO PURGE (no temp alarms)and cool boot for screw timing is up

R
PORCHESON
10
User's Manual for MK3XX V1.0 Chapter 2 Explanation of the Key Operations

Keys Usage Operation Conditions

多次托模
1.operation condition is same as ejector advance,ejector retreat
multi-ejector operation 2 . set times of ejector not finished
EJECTOR

润 滑
lubirca ting pump working 1.Total time of lubricating not completed
LUBR.

公模吹气
1. male blowing optional
male blowing operation 2. male blowing time not completed
AIR BLST. MOV.

母模吹气
1. female blowing optional
female blowing opeation 2. female blowing time not completed
AIR BLST. STN.

座台进 1 .nozzle advance lim it not being used,no conditi on


2. nozzle advacne lim it being used,a not reached nozzle advance
nozzle advance operation sto p positio n b.timing for nozzle advance slo w not reached
NOZZLE ADV.

座台退
nozzle retrea t operation 1.no conditions
NOZZLE RET.

1.when manual mode is being used for mold adjustment,press


调 模 Down the key and then if indicator ligh flash means manual
adjustment is allowed
mold adjustment option
2.when auto mode is being used for mold adjustment,press
MOLD ADJ. down the key twice and then if indicator ligh flash means
auto adjustment is allowed

调模退
mold adjustment backward 1. ent er into manual adj ust ment mode
operation 2. mold adj ust ment backw ard not reached its terminat ion posi tion
MOLD THICK

调模进
mold adjustment forward 1 enter into manual adjustment mode
operation 2 mold adjustment forward not reached its termination position
MOLD THIN

R
PORCHESON
11
User's Manual for MK3XX V1.0 Chapter 2 Explanation of the Key Operations

Keys Usage Operation Conditions


中子A进 1 .Core A being used
A core A advance operation 2 . core A advance not reached termination position or time
not completed
CORE A IN 3 . ejector retreat reached position or ejector retreat time is up

中子A退 1 . core A being used


A 2 . core A retreat not reached termination position or time
core A retreat operation not completed
CORE A OUT 3 . ejector retreat reached position or ejector retreat time is up

中子B进 1 .Core B being used


B core B advance operation 2 . core Badvance not reached termination position or time
not completed
CORE B IN 3 . ejector retreat reached position or ejector retreat time is up

中子B退 1 . core B being used


B 2 . core B retreat not reached termination position or time
core B retreat operation not completed
CORE B OUT 3 . ejector retreat reached position or ejector retreat time is up

中子C进 1 .Core C being used


C core C advance operation 2 . core C advance not reached termination position or time
not completed
CORE C IN 3 . ejector retreat reached position or ejector retreat time is up

中子C退 1 . core C being used


C 2 . core C retreat not reached termination position or time
core C retreat operation not completed
CORE C OUT 3 . ejector retreat reached position or ejector retreat time is up

中子D进 1 .Core D being used


D core D advance operation 2 . core D advance not reached termination position or time
not completed
CORE D IN 3 . ejector retreat reached position or ejector retreat time is up

中子D退 1 . core D being used


D 2 . core D retreat not reached termination position or time
core D retreat operation not completed
CORE D OUT 3 . ejector retreat reached position or ejector retreat time is up

line of Mk360 Keyboard

Nitrogen recharge operation 1 stocker up limit not reached its termination position

R
PORCHESON
12
User's Manual for MK3XX V1.0 Chapter 2 Explanation of the Key Operations

Keys Usage Operation Conditions


line of MK360 Keyboard

nitrogen release operation 1 . No condition;

line of Mk360 Keyboard

safe door open operation 1. Safe door open not reached its termination position or
time not completed

line of Mk360 Keyboard

safe door close operation 1. Safe door clo se not rea ched its term ina tion posit ion

line of Mk360 Keyboard

Standby operatio n keys

line of Mk360 Keyboard

Standby operatio n keys

8. Setting Scope of Numeric Items

Number Setting Items Setting Scope Unit

1 Time Setting Digital ≤6 00.00 Second

2 Pressure Setting Digital ≤1 60.0 Bar


3 Speed Setting Digital ≤9 9.9 %

4 Back Pressure Digital ≤ 160.0 Bar


Digital ≤ 999.9(Measure)
5 Temperature Setting
Digital ≤ 600.0(set)

6 Storage of Mold Data Digital ≤ 999 Number

7 Predicted Turnout Digital ≤9 9 9 9 9 9 9 9 PC

In case of the set values exceed the above-mentioned scopes, the system will not accept the
numbers set and keep the original set values. For the habit of data input, the data input of this
system is display from right to left.

R
PORCHESON
13
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

Chapter 3: Descriptions on setting parameters/functions

1. Main page of Starting up


Connect with power, turn the red urgent stop switches, the operation light of the computer-
RUN-flickers, the following menu shown on the display, now the control system is running
and it is ready to operate the machine.
2010-03-28 *Manual* 20:38:08
Nozzle 1Segment 2Segment 3Segment 4Segment 5Segment oil temperature Mold number: 2512
34.2 34.3 34.1 34.1 34.1 34.3 **** G-18CUP
Setup: 50.00 s Pressure: 20.0 bar Cycle: 216.90 s
Operate: 2.14 s Flux: 20.0 % back pressure: 0.0 bar
Temperture.OK

33 66

0 99
7.6 %

33 66

0 99
7.6 %

Move mold: 593.9 mm Ejector: **** mm estimate production: 0 mode


Screw: 6.15 mm Screw speed: **** R/M current production: 0 mode
Machine Run Well Ready

监 视

Press MONITOR key at any time after re-turning on the computer, and then enter the menu of
the monitor menu of the machine. This menu is for monitoring temperature and machine running
condition.The names and numbers of the moulds will be set in mould information menu.The
tempe rature scale and current oil tempe rature show the real value of each stage thus its informat ion
cannot be mod ified. Each function of the men us is described as follows:
The descriptions on mode:

Mode Meanings

Motor is running

Electric heating is operated


Lubricant pump is working with oil

R
PORCHESON
14
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

2.The descriptions on display:


Display Meanings and descriptions

Manual The running mode of the machine;


Injector This section is heating;

Mold number The current mold number;


Movable mold Shows the current position of the mold. The unit: mm;
Screw Shows the current position of the screw. The unit: mm;

Thimble Shows the current position of the thimble. The unit: mm;

Pressure The set pressure value of the current movement;

Flux The set flux value of the current movement;


Estimated output Estimat ed output of current mou ld numbe r;

Output Record the numbers of mould opening for current mould number during the
automatic operation of the system;
Set The time value and counter data of the current movement;
When a time value is set for current movement, only the operation time gradual
Operation ly reached set value, can next movement be proceeded, if number of times is set
correspondingly the number of times would be displayed and to reached its set .

Cycle Cycle time of actual operation of system;


Actual temperature is not within setting range, showing current ly all
Low temperature
sections of temperature are abnormal
Screw speed The number of rotation of the screw in one minute (unit: RPM);

3.Descriptions on alarm mode


Alarm Source Solution
1.The re is no 24 v voltage output from 1.repair power supply
power supply 2.repair main board
short circuit of input terminal
2.Malfunction from main board 3.check peripheral circuit to find out
3.short circuit on peripheral circuit short circuit source
of input or output terminals

Neutron A is not reach Neutro n A ,B ,C,D was chosen by machine Check whether end switc hes of neutro n A and
set point ,Limit connection of neutron A, B,C, B ,C,D were connected correctly and can
Neutron B is not reach D retreat must be done while at the be press -fit nor mally. Please chos e disabl e
set point. time of eject-forward or multi-eject. for neutron A and B ,C,D while not using
.
Neutron C is not reach neutron functions
set point.
Neutron D is not reach
set point.

R
PORCHESON
15
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

Alarm Source Solution


Please check whether switches of rear safe
Rear safe door unclosed Switches of X15 and X16 of rear safe
door are in OFF status . door correctl y connect with ports X15 and
X16

Please open safe door In semi-auto operation, single cycle Please open safe door to take out made product,
ends,but safe door is not opened close safe door and then continue to work

Failure of sensor inspection In automatic operatio n, when inspectin g Eliminate faults of ejecting forward or eject ing
sensor is still not ON after thimble retreats
backward and judge if electric eye was estopped.
of sensor cycle mode and mid-time is over, Key inspection should be on conne ctions of sensor
Failu re of sensor inspectio n will be or sensor itself if light of X04 input port is on.
alarmed.
Mould opened is not reach Clam ping and open mould not complete d Reoperate mould opened or check mould posi
set point within“ the time limitation of the tion 1, if electronic ruler is ’able‘state,check
mould opening or closing” position reading 2,if electronic ruler is ’disable
state ,check X12 to confirm it is connected
Mould opening/closing Mould opening/closing is not done Check if there are abnormals in the
beyond fixed time within
. fixed time .process of mould opening/closing,if
result is normal,adjust fixed time appro
priately

Low- pressure protection Suppose low-pressure time is up, and Check if there are sundries in the mould,
time is up yet not change to high-presssure,alarm If resul t is no, adj ust time of low- pres sur e
will be on prot ect ion appropr iately
Fault of safe door When only one of X00 and X01 is Please check to see whether switches of
on, system alarms Fron t /Rear safe door is connected correctly
. with input ports of X01 and X02

Feeding is not done within While feeding, it is not done within Check if there are any abnormals during
fixed time fixed time the process of feeding and check whether
material inside charging barrel is none,
if result is normal, adjust time of feeding
appropriately
Failure of injection Fail to press fit to stroke switch of Check process of injection and adjust
injection inspection during the pro deviation value of injection inspection
cess of injection or fail to reach inje
ction inspection point while choose
electronic ruler

Motor is mulfunction When there is signal inputs at motor Check if hydraulic motor was working
.
protection point, system will be ala with overload that cause thermal realy
rmed to have protection action

Cycle time is up Automatic production cycle time Chec k if there are abnormals during the
exceeds set value process of automat ic production ,if result
is normal,adjust cycle time appropriatedly

R
PORCHESON
16
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

Alarm Source Solution


Machine stops when output of mach Solution: If you need the machine continues
ine halt is started and the numbers of Running after the output reached, just set
Set output is reached mould opening reached set value of The [stop after alarm] in produc tion menu
output.
as [out]; or reset the total mould opening
of the current mould number .

4.Descriptions on operation/prompt mode

Alarm Source
High temperature in 1,2,3, Current section real temp to machine hopper is higher than max temp value..
4,5, sections Injection nozzle. (Higher limit value of temp = setting value of temp + setting value of upper limit).

Low temperature in 1,2,3,4, Current section real temp to machine hopper is lower than min temp value..
5, sections Injection nozzle. Lower limit value of temp = setting value of temp - setting value of down limit).
Temperature short circuit in
1,2,3, 4,5, sections Injection Current section temp line was shorted or faulted to machine hopper.
nozzle
Auto material clearing After setting Number of movements completed and when using auto
completed material clearing
Auto mold adjusting
completed Auto mold adjusting completed when using mold auto adjusting.
Auto mold adjusting
not completed Auto mold adjusting not completed when using mold auto adjusting.

Enter manual mode first Operate manual keys when under auto state..

Functions not selected Certain function has not been selected when manual operate its keys.

Start motor please When choose to use motor, pressed semi-auto/auto keys but motor yet
not started.

Next cycle Prepared In auto mode, the mid-time between completing a cycle and starting next cycle.

Sensor prepared The mid-time has not been reached after withdrawing thimbles during auto sensor
cycling.
Exit mould adjusting When operate non-[adjust forward, backward ] keys under mold adjusting state.
mode first
Enter mould adjusting When operate [adjust forward, backward ] keys under non-mold - adjusting state.
mode first

R
PORCHESON
17
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

5. Setting for celerity information


快速设定

Press CELERITY SET key, enter the menu for fast setup 1 information, now as following:

2016.05.05 Fast setup1 10:07:12


Pressure Flux Place Delay Time Eject Times
ejector advance fast 20.0 20.0 508.8 0.5 0.8 2
ejector advance slow 50.0 80.0 109.0 ***** 1.0
ejector hold 20.0 30.0 2.0 **** 1.0
ejector retreat 120.6 25.0 ***** 0.6 *****
mol d clamp slow 20.7 20.0 50.0 low pressure pr0tection 50.00
mol d clamp fast 40.0 80.0 215.0 mold clamping time limit 50.00
low pressure mol d clamp 60.0 70.0 550.0 differential mold clamping Disable
high pressure mol d clamp 45.0 20.0 600.0

mold opening time limit *****


open mol d slow 60.0 80.0 ***** Manipulator Disable
open mol d fast 55.0 20.0 *****
open mold intermediate speed 50.0 10.0 ****
open mol d low speed 50.0 40.0 *****
Hint:set range:0.00~600.00

快速设定

Press CELERITY SET key twice, enter the menu for fast setup 2 information, now as following:

2016.05.05 Fast setup 2 10:07:12


Pressure Flux Time Place Back pressure
Forward inject retreat 30.0 250.0 ***** 20.00 **** Cool time
Feeding 1 120.0 85.0 ***** 150.00 15.2 30.00
Feeding 2 80.0 20.0 220.00 20.2 Feed limit
backward -inject-retreat 50.0 43.0 ***** 250 ***** 80.00
Total time
Inject 5 Segment 125.9 95.0 ***** 0.00*
50.00
Inject 4 Segment 110.0 90.5 ***** 5.00
Inject way
Inject 3 Segment 30.0 20.0 ***** 20.00
Inject 2 Segment 110.8 80.0 ***** 70.00 Place
Inject 1 Segment 20.6 40.0 ***** 120.00
pressure holding 4 20.0 20.0 1.00
pressure holding 3 35.0 25.0 1.10
pressure holding 2 50.0 35.0 2.59
pressure holding 1 45.0 20.0 1.25

Hint:0.time 1.place

Fast setup 1 and 2 menus are parameters cluster menus common used by jet plastice machines.
These
. two menus can provide important parameters needed daily adjustment by machines,
including: mold close, mold open, injection, hold pressure, plasticization, ejector forward .

R
PORCHESON
18
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

6. Set moId close information

开锁模
M.PLT
Press key, enter the menu for setting mold close information , now the menu is as followi ng:

2016.05.28 Mold close 10:07:12

system pressure: 20.0


593.9 mm system flux: 20.0

Mold close pressure: ******Bar

slow speed fast speed low pressure high pressure


Pressure (bar) 20.0 50.0 20.0 120.0 low pressure protect(s) 30.00
Flux(%) 20.0 80.0 20.0 25.0 Mold close limit(s) 30.00
Place(mm) 508.8 109.0 2.0 Differential mold close Enabled

Hint:
Machine Run Well mold close slow

Descriptions on setting parameters/ process/function mold

Action S low Fast Low pressure high pressure

Pressure 20 50 20 1 20
Flux 20 80 30 25
Place 508.8 109.0 2.0
(1). Process: while closing mould, enter slow clamping first, and then enter fast clamping stroke
Arrives at[508.8], and then enter low pressure clamping when stroke runs another [109.0],And
then enter high pressure clamping when stroke runs another [2.0] till clamping completed. It alarms
[low pressure mould protection time is over ] when the low pressure time is over but not enter the
high pressure yet.
(2). Low pressure protection: Set a smaller low-pressure time for mou ld closing, it is better to be fitting,
otherwise,the mou ld can not be protected.
(3). Limitation to mould closing: time limitation to mold closing,please set it longer, and it is Better to
be fitting, otherwise, the system alarms [mold open/close not completed on time].
(4).Differential mould closing: press enter key to select[on]or[off], output when select [on]for
quick mould closing and Y12 is with signal, when select[off] for quick mould closing,and
Y12 is without signal.

R
PORCHESON
19
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

7. Set moId open information

开锁模
M.PLT
Press key twice, enter the setting mold open information, the menu is as following:

2016.05.28 Mold open 10:07:12

system pressure: 20.0


593.9 mm system flux: 20.0

Mold close pressure: ******Bar

slow speed middle speed Fast speed slow speed


Pressure 45.0 50.0 40.0 20.7
Flux(%) 20.0 70.0 80.0 20.0 Mold open limit(s) 30.00
Place 600.0 550.8 212.5 50.5 mechanic hand Disabled

Hint:0.disabled 1.enabled
Machine Run Well mold close slow

Descriptions on setting parameters/ process/function mold

Action Low Middle Fast Slow


Pressure 45 60 40 20
Flux 20 70 80 20
Place 600.0 550.8 215.5 50.5
(1).Process: while opening mould, enter slow mould opening first, and then switches to fast mould
Opening when stroke arrives at 50.5mm, and then switches to middle speed mould opening when
arrives at 215.5mm, and then switches to low speed mould opening when arrives at 550.8mm,and
then mould opening completed when arrives at 600mm
(2). Mould open limit: time limitation to mould opening and clamping, please set it longer, and it is better to be
fitting, otherwise, the system alarms [mold opening/clamping not completed on time].
(3).The function of mechanical arm : if a mechanical arm is needed, please select [on] for it. After [on]
selected,the machine will output manipulator signal while mold opening completed. Before
mold close,the Next cycle starts only after receiving the manipulator signal, and stop the output
of it at the same time.

R
PORCHESON
20
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

8. Set the injector information

射 出
INJECTION
Pres s key, enter the menu for setting inje ctor info rmation , now the menu is as following :

2016.05.28 Injection setup 10:07:12

system pressure: 20.0


6.15 mm
system flux: 20.0

Injector pressure: ****** bar

5Segment 4Segment 3Segment 2Segment 1Segment


Pressure 125.9 110.0 30.0 110.8 20.0 Injection total time
Flux(%) 95.0 90.5 20.0 80.0 40.0 20.00
Injection method
Place 0.00 5.00 20.00 70.00 120.00
Place
Time **** **** **** **** ****

Hint:0.place 1.time
Machine Run Well mold close slow

Descriptions on setting parameters/ process/function mold

Action Segment5 Segment4 Segment3 Segment2 Segment1


Pressure 125 110 30 110 20
Flux 95 90 20 80 40
Place 0.00 5.00 20.00 70.00 120.00
(1).Process: while injecting, 1stage injects plastic first, and then switches to stage2when arrives
at 220.0mm, and then switches to stage 3 when arrives at 150.9mm, and then switches to Stage 4
when arrives at 98.5mm, and then switch to pressure retaining when arrives at 10.0mm
(2). Injection total time; monitor normal travel of injection.It starts to count when entering into injection
and wait to be time up,if choose [injection total time],it will switch to pressure holding Regardless
of distance reached or not,. Thus the injecting time should be set longer than real time.
(3).Injectoion pattern: when screw electronic ruler is on ,[Position] or [Time] can be selected. a. If
Select [position], injection will be switched to pressure maintaining from electronic Ruler
position; b. If select [time],injection will be switched to pressure maintaining from Time.

R
PORCHESON
21
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

9. Set the hold pressure information

射 出
Press INJECTION key twice, enter the hold pressure information , the menu is as following:

2016.05.28 Hold pressure 10:07:12

system pressure: 20.0


6.15 mm
system flux: 20.0

Injector pressure: ****** bar

4Level 3Level 2Level 1Level


Pressure 20.0 35.0 50.8 55.0 Injection check Enabled
Flux 20.0 25.0 35.0 20.0 _ 2.00
allowable deviation +
Time 1.00 1.10 2.59 1.25 collect mold number 20
Slope Disabled Disabled Disabled Disabled reference standard 20.00

Hint: set range:20~100


Machine Run Well mold close slow

Descriptions on setting parameters/ process/function mold

Le ve l5 Pr es
Level 4 Level 3 Level 2 Level 1 125.9

50 55
35
Level 4 Level 3 Level 2 Level 1
Pres 20 35 50 55
20
Flux 20 25 35 20

Time 1.00 1.10 2.59 1.25 (Curve graph of slope function)


(1). Process: when entering into phase of pressure maintaining after injection, firstly from level 1 pressure
of pressure maintaining and speed movement when [lever 1 time is up] enter into level 2 pressure maintaining
And then enter into level 3 of pressure maintaining when [level 2 time is up],and enter into level 4 of pressure
maintaining when [level 3 time is up] and then switch to storing delay when [level 4 time is up].
(2).Method of application: when level 1 pressure maintaining control is enough for condition of moulding
control method is as below:please input time for level 1 pressure maintaining on level 1 time column ,
level 2 pressure maintaining time [0.00 set to be 0 while disable],level 3 pressure maintaining time
[0.00 set to be 0 while disable],level 4 pressure maintaining time [0.00 set to be 0 while disable]
(3). Slope function: Controlling pressure maintaining means to hold pressure or slope change, referring to
page to setting, the actual pressure output is as above chart.
(4). Injection inspection:[Disable] and [Enable] cab be selected. Computer will automatically take
average of injection terminal of first 1-100 output as inspection point, user can set alllowable
error of numerical value on page of pressure maintained. If exceeds set mould numbers, and
result is not reached or exceeded inspection range,[Injection fail] will be alarmed and meantime
it will be regarded as defected product by output management .

R
PORCHESON
22
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

10. The feed/suck back/cooling setup information

储 料
FEEDING
Press key , enter the feed/suck back/cooling setup information ,now the menu is as
following:
2016.05.28 Feed/suck back/cooling setup 10:07:12

system pressure: 20.0


6.15 mm
system flux: 20.0

system back pressure: 0.0

Forwarde inject retreat Feed 1 Feed 2 Back ejector Cooling time


Pressure(bar) 30.0 120.0 80.0 50.0 30.00
back pressure (bar) **** 15.0 20.2 **** Feed limit
80.00
Flux(%)25.0 85.0 20.0 43.0 Feed delay
Place 20.0 150.0 220.0 250.0 1.0

Hint: set range:0.0~99.9


Machine Run Well mold close slow

Descriptions on setting parameters/ process/function mold

Action Front ejector Feed 1 Feed 2 Back ejector

Pressure 30 120 80 50
Back Pressure 15 20
Flux 20 85 25 43
Place 20.0 150.0 220.0 350.0
(1). Process:After phase of pressure mai ntaining, it will switch to storing 1whe n injection retreats mov e
To20.00mm, and then switch to storing 2 when move to150.0mm,and then switch to suck back
backward when move to 220.00 and finish storing when move to 250.00mm.
(2). Feed limit Time : Monitor time for no material. It is regarded as no material when time is up but
Feeding is not completed, therefore, set time limit longer than actual feeding time, otherwise,
[feeding not completed on time] will be alarmed.
(3).Cooling time: In auto mode, injection and pressure maintaining are completed, cooling time starts
To count, time for feeding and injection retreats is also part of cooling time. If movement time ex
ceeds cooling time, cooling time will end, and mould opened can be proceeded only if feeding,in
jection retreats finished, conversely, cooling time ends to open mould immediately.
(4)Feeding time delay: Set delay time when under auto state and then to proceed for feeding.

R
PORCHESON
23
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

11. Set the auto clear setup information

储 料
FEEDING
Press key twice, enter the auto clear setup information , now the menu is as followi ng:

2016.05.28 Auto clear setup 10:07:12

system pressure: 20.0


6.15 mm
system flux: 20.0

system back pressure: 0.0

Inject Feed Suck Back


aut o purgi ng Enable
Pressure(bar) 65.0 120.0 60.0
purgi ng times 5
Flux(%) 70.0 85.0 55.0
Refeed time 1.00
Time 2.55 10.50 3.58

Hint: set range: 0.00~600.00


Machine Run Well Feeding 1

Descriptions on setting parameters/ process/function mold

Inject
[NO]
Feed Suck Back Times of material clearing up?

[Yes]
[End]
(1).Process: How to use the stuff auto-clearing up function. In manual mode, press key of material
Auto-clearing up, the system starts the material auto-clearing up process, first is process of with
drawing, and then cycles automatically according with process shown in the diagram above.
(2) Automatic material clearing:.Under manual mode, press [automatic material clearing] key,
for automatic material clearing movement
(3)Times of material clearing: Repeat movement of feeding and injection..
(4) Material restoring time: Under auto mode, to proceed feeding movement when move forward
completed and time is up then change to injection movement. .

R
PORCHESON
24
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

12. Set the nozzle information

座台/调模

Press NOZZ/ADJ. key, enter the menu for setting nozzle information , now the menu is as following:

2016.05.28 Nozz le setup 10:07:12

6.15 mm
system pressure: 20.0

system flux: 20.0

system back pressure: 0.0

Nozzle advance slow Nozzle advance fast Nozzle return


Pressure 20.0 35.0 50.8 Auto n ozzle return positon
Disabl e
Flux 20.0 25.0 35.0
Nozzle return end method
Place ***** ***** *****
Locatio n
Time 1.00 ***** *****

Hint: 0.time 1.location


Machine Run Well mold close slow

Descriptions on setting parameters/ process/function mold

(1)Move forward slow motion: ①When electronic ruler is [disable], move forward encounters
switch of move forward[X06] and then change to move forward slow and mould combination
and time will counts to end of move forward ② when electronic ruler is [Enable],move forward
Fast or slow was controlled by position of electronic ruler.(Function:To prevent crashing and
protect mould)
(2)Position of auto base retreats:[Disable]or [Feeding completed] or[ cooling completed] can be
selected, when [Feeding completed] is selected and under auto mode, move backward will be
proceeded after feeding and sucking back finished, and when [cooling completed] is selected
and under auto mode, move backward will be proceeded after cooling is finished.
(3) Move backward termination methods: ① When electronic ruler is [Disable], [travel] or [time
can be selected, when [travel] was selected,] the position of automatic base was controlled by
base stopped backward limit switch [X07],and when [time] was selected, the retreat of automatic
Base was controlled by time.② when electronic ruler is [Enable], [position] or [time] can be
selected, while [position] was selected, the retreat of automatic base was controlled by position
Of electronic ruler; while [time] is selected, the retreat of automatic base was controlled by time.
(Notice: Under manual mod e, press [nozzle Ret] key and nozzle ret mov ement will not be affected.)

R
PORCHESON
25
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

13. Set the mold adjusting information

座台/调模
NOZZ/ADJ.
Press key twice, enter the menu for setting mold adjusting, now the menu is as following:

2016.05.28 Mold adjusting setup 10:07:12

system pressure: 20.0

system flux: 20.0

system back pressure: 0.0

Mold thick Fine adjust Mold thin


Pressure 20.0 35.0 50.8 initial adjustment advance teeth Number Time
Flux 20.0 25.0 35.0 mold adjustment way 6.00
mold clamp time ***

Hint: 0.time 1.teeth


Machine Run Well mold close slow

Descriptions on setting parameters/ process/function mold

(1).adjust way: [Manual] or [Auto] can be selected, the pressure for mould adjusting is about 20
- 50 bar, the speed is 30-60%.
(2). fine adjust teeth number : [Time]or [gear number]can be selected. Select [time] if the machine is
not mounted with sensor; the initial value is controlled by [time]; select [gear number] if there
is a sensor, the initial value is controlled by [gear number].
(3).The time of mold closing: In auto mould adjusting, time limitation for mould closing.
(4).How to use auto mold adjusting: Select[auto]for mold adjusting, press the key[mold adjusting]
and [auto mould adjusting], and than enter the mode of auto mould adjusting as soon As the exit
shut. The movement pressure and flux of adjusting forward and backward in the process of
auto mould adjusting is controlled by a set value in the fine adjusting box. The sound of can be
heard and [mould adjusting completed] shown after the mould adjusting completed.
(5).Initial adjustment number of teeth:the no. of teeth which is nothing change in number of teeth
after 1 st mold thin of auto mold adjustment and then open mold and readjust.

R
PORCHESON
26
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

14. Set the ejector forward information

托模/中子
EJE/CORE
Press key , enter the menu for setting ejector forward, now the menu is as following:

2016.05.28 Ejector setup 10:07:12

system pressure: 20.0

200.0 mm system flux: 20.0

system back pressure: 0.0

Ejector return Ejector advance fast Ejector advance slow Keep Ejector times
Pressure 45.0 55.0 50.0 50.0 3
Flux 45.0 20.2 10.0 10.0 Ejector Method
Place ***** ***** ***** ***** times
Delay 0.6 0.5 **** **** stop holding
Time **** 0.8 **** 1.0 Disabl e
Hint:0.times 1.vibrating 2.retaining
Machine Run Well mold close slow

Descriptions on setting parameters/ process/function mold

(1) Times fixed : [Ejecting forward] → [Ejecting forward stopped] -[Maintain] -[Ejecting backward]
[Ejecting backward stopped] as one cycle, move in according to times.
(2) Vibrating:[Ejecting forward stop] -[Ejecting forward stop]-[0.1Ejecting backward]-[time is up]
as one cycle, set movement according with ejecting times, and ejecting backward movement will
stop when times is finished.
(3) Remain:[Ejecting forward]-[Ejecting forward stop] movements stop ,ejecting backward will only
Be conducted only before mould closing of next cycle.(Notice:[Remain] movement will not be
limited by times, movement will be only conducted once when [times of ejecting] is larger than
(4). Backward delaying: after ejecting forward completed, the ejecting backward movement
occurs while the set time delayed.
(5). Forward delaying: after mould opening completed, the ejecting forward movement occurs
while the set time delayed.
(6) Maintaining function: If maintaining time set to be 0,there is not maintaining function.The
Retaining function is for retaining pressure,speed and starting retaining time for the output
after ejecting forward completed. The retaining movement is completed as soon as the time
. is over.
(7). Ret ain maintaining function: [Ena ble] and [Disable] are available. Select the ejecting mode as retain
whi le under semi-auto state. When retain maintaining selected disable, the process:ejecting forwar d
stop--maintaining(time is up or opening and closing safe door)--cycle over,conversely, ejecting
forward stop--cycle over.
(8) [Notice]:a.While ejecting is under manual mode, it will not be limited by times.(But while multi-
ejecting is under manual mode, it will be limited by times)b. Ejecting function will be disable
when [ejecting times] was set to be 0.

R
PORCHESON
27
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

15. Set core A B information

托模/中子
EJE/CORE
Press key twice, enter the menu for set ting coreA B inform ation, now the menu is as following:

2016.05.28 Core A B setup 10:07:12


system pressure: 20.0
Movement mold
system flux: 20.0
593.9 mm
system back pressure: 0.0

Core A in Core A out Core B in Core B out


Pressure (bar) 65.0 65.0 40.0 35.0
Flux (%) 35.0 50.0 25.0 15.0
Core A Disa ble
Time **** **** 3.0 3.0 A method Way
Count *** *** *** *** Core B Disa ble
Start stroke Mold close stop Mold open stop front mold close Front mode open B method Time
Start position ***** ***** ***** *****

Hint:0.time 1.way 2.count


please turn on the oil pump.

Descriptions on setting parameters/ process/function mold

(1) Core A function: [Neutron],[Twist], [Disable] can be selected, while selecting neutron, inlet
valve of core A will output meantime when injecting, while selecting twist, inlet valve of core
A will not output meantime when injecting.
(2)Core B function:[Neutron],[Twist],[Disable] can be selected, while selecting neutron, inlet
valve of core B will output meantime when injecting, while selecting twist, inlet valve of core
B will not output meantime when injecting.
(3)Mode A. [Time], [stroke] and [count] can be selected. If [time] selected, set the time till the
movement of loose core A terminated; if [stroke] selected, the movement of loose core will not
terminate until the stop signal [X25, X26] of input point shows ON; if [count] selected, pipe
Thread control can be taken, and the movement termination is decided by the number of pipe
tread pulse inputted through [X25 ].
(4). Mode B: [Time], [stroke] and [count] can be selected. If [time] selected, set the time till the
terminate until the stop signal [X30, X31] of input point shows ON; if [count] selected, pipet
movement of loose core B terminated; if [stroke] selected, the movement of loose core will not
Hread control can be taken, and the movement termination is decided by the number of pipe
tread pulsein putted through [X30]
(5). Time: When neutron A or B select time, foward/backward of neutron was controlled by time.
Gear number:When neutron A or B select gear number,forward/backward of neutron was continue
rolled by gear number..
(6). Start stroke : the neutron start the position of movement (neutron in: [before lock the mode],
[before the low pressure], [before the high pressure] and [the lock mode stops]; neutron out:
[Before the mode opening] [before the middle speed], [before the low speed] and [the mode
Opening stops]), that is, where the template is moving, setup the action of neutron A and B.
(7).Start position: The position for starting the movement of core knock in or knock outwhere the
mould stops-- is a set value for the movement of core loose A and B.

R
PORCHESON
28
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

16. Set core C D information

托模/中子
EJE/CORE
Press key three times , enter the menu for setting coreC D, now the menu is as following:

2016.05.28 Core C D setup 10:07:12


system pressure: 20.0
Movement mold
system flux: 20.0
593.9 mm
system back pressure: 0.0

Core A in Core A out Core B in Core B out


Pressure (bar) 65.0 65.0 40.0 35.0
Flux (%) 35.0 50.0 25.0 15.0
Core A Disa ble
Time **** **** 3.0 3.0 A method Way
Count *** *** *** *** Core B Disa ble
Start the way front mold close Mold close stop Front high pressure Front mode open B method Time
Start the place ***** ***** ***** *****

Hint:0.time 1.way 2.count


Machine Run Well mold close slow

Descriptions on setting parameters/ process/function mold

(1) Core C function: [Neutron],[Twist], [Disable] can be selected, while selecting neutron, inlet
valve of core A will output meantime when injecting, while selecting twist, inlet valve of core
C will not output meantime when injecting.
(2)Core D function:[Neutron],[Twist],[Disable] can be selected, while selecting neutron, inlet
Valve of core B will output meantime when injecting, while selecting twist, inlet valve of core
D will not output meantime when injecting.
(3)Mode C. [Time], [stroke] and [count] can be selected. If [time] selected, set the time till the
movement of loose core A terminated; if [stroke] selected, the movement of loose core will not
terminate until the stop signal [X25, X26] of input point shows ON; if [count] selected, pipe
Thread control can be taken, and the movement termination is decided by the number of pipe
tread pulse inputted through [X25 ].
(4). Mode D: [Time], [stroke] and [count] can be selected. If [time] selected, set the time till the
terminate until the stop signal [X30, X31] of input point shows ON; if [count] selected, pipet
movement of loose core B terminated; if [stroke] selected, the movement of loose core will not
Hread control can be taken, and the movement termination is decided by the number of pipe
tread pulsein putted through [X30]
(5). Time: When neutron C or Dselect time, foward/backward of neutron was controlled by time.
Gear number:When neutron C or Dselect gear number,forward/backward of neutron was continue
rolled by gear number..
(6). Start stroke : the neutron start the position of movement (neutron in: [before lock the mode],
[before the low pressure], [before the high pressure] and [the lock mode stops]; neutron out:
[Before the mode opening] [before the middle speed], [before the low speed] and [the mode
Opening stops]), that is, where the template is moving, setup the action of neutron A and B.
(7).Start position: The position for starting the movement of core knock in or knock outwhere the
mould stops-- is a set value for the movement of core loose C and D.

R
PORCHESON
29
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

17. Set blowing information

托模/中子
EJE/CORE
Press key fouth, enter the menu for setting air blow information, now the menu is as
following:
2016.05.28 The blowing setup 10:07:12

system pressure: 20.0

Movement mold system flux: 20.0


593.9 mm
system back pressure: 0.0

Air blow male Air blow female


Time 1.5 2.3
Delay 0.2 0.0
start position ***** *****
start stroke before mold open before mold open
functional way Enable Enable

Hint:0.disable 1.enabled
Machine Run Well mold close slow

Descriptions on setting parameters/ process/function mold

(1) . Why blowing air: This function can be used in the stamping mold that need air blow.
(2).Time delay: Delay first when arrives automatically at the position of air blow, and than blow
air when delay time starts.
(3).Start the way: you can select[before the mold opening] or [after the mold opening] to set the
value of blowing.
(4) . Starting position: [Pre-mold opening] can be selected. [Pre-mold opening] is taken as a set
value for the movement of air blow.
(5).Function mode: [On] or [Off] can be selected, no movement of air blow if [Off] is selected.

Mold end,delay count

Blow Male

Mold end,delay count

Blow Female

R
PORCHESON
30
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

18. Set time/count information

时 间
TIME
Press key , enter the men u for setting time/ count informat ion , now the men u is as following:

2016.05.28 Time/count setup 10:07:12

lub rica te mold number 1 cycle waiting time 1.00


lubricate total time 8.00 sensor detection time limit 99.00
lubricate time 4.00 Manual movement time limit 99.00
lubricate intermittent 1.00 fault alarm time 10.00
The blowing key Key cycle time 120.00

System boot time 8 1


Auto runs time 18 8
Motor runs time 14 4

Hint:range:
emergency stop not released

Descriptions on setting parameters/ process/function mold

(1). Lubricate mold number: Count mold opening times. The oil pump starts when mold opening
times reach the set value.
(2). Lubrication Total time : the total time spent in this lubrication.
(3). Lubrication time: the output of the repeated operation with the total time for lubricatin.
(4). lubricate intermittent: The interval of the repeated operation with the total time for lubricatin.
(5). Cycle Wait time: During auto process, it is the time between completed thimble movement and
starting a movement of moulds clamping of next cycle.
(6).Cycle time: The time limitation to operation cycle in automatic process. The system alarms
[cycle time is over] when the real operating time is longer than cycle time limitation.
(7).Movement time limitation: the max time permitted when output movement.
(8).Error alarm bell: The max time when error output occurs. To avoid long time alarming, the
bell stops alarm when time is over.
(9) Alarm interval: The time between alarm output and stop in alarm time.
(10).Lubr ication process: As it shows in the follow chart ,During the output time of lubrication, if it fails
to detect any lubrication pressure signal, it would trigger an alarm, telling that the lubrication
is failing. If “opping working” after the failing of lubrication is chosen, then it would stop
lubricating and would change to work in manual mode and stop the engine after the cycle of
the alarming.

Output Lubric space

Lubrication total time

R
PORCHESON
31
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

19. Set temperature information

温 度
TEMP.
Press key, enter the menu for setting temper ature information , now the menu is as followi ng:

temperature test Temperature setup 10:07:12

Ejector 1Segment 2Segment 3Segment 4Segment 5Segment


Actual 34.6 34.8 34.9 34.9 **** ****
Setup 34.3 34.9 34.9 30.0 ***** ****
State Normal Normal Normal Normal ***** ****
Maximum 5.0 5.0 5.0 5.0 *** ***
Minimum 5.0 5.0 5.0 5.0 *** ***

Nozzle way Close loop Half temper ature funct ions Close
Cold boot 12.00 electric heat state Close
Hint:range:0.00~99.99
Machine Run Well mold close slow

Descriptions on setting parameters/ process/function mold


The set temper ature val ue is 0.1℃( Celsius). The temper ature of the hopper of injection molding machine
is close-loop controlled after it is fed back to controlling system by K style thermal electriccouple.
The system provides total 6 stages of temperature control and 1 stage oil temperature testing. [Open-
loop] /[close-loop]can be selected to control temperature for injection nozzle. The system monitors
The temperature in every area to find out if the temperature over passes the set top and bottom
limitation. It cannot inject or melt plastic if the temperature is lower than the bottom limitation
and than the cold preventing screw starts. It alarms when the temperature is higher than the top
limitation. The temperature of each stage is shown on the main menu.
Half of temperature functions: select use, at this time, the temperature setup value is half of the current
showed setup value.
Cold boot: After the boot, the actual temperature in each area will be within the setup scope.
部 分 塑 胶on密
References 度 plastic
some 与 料 densities
管 加 热and温pipe
度 heating
参 考 temperatures
资 料
原料简名
Material abbreviation 密度
Density 加热温度ºC
Heating temperature 原料简名
Material abbreviation 密度
Density 加热温度ºC
Heating temperature
A.B.S 1.01-1.05 190-270 PMMA 1.17-1.20 180-260
PS 1.05 190-240 PPO 1.08-1.09 260-330
A.S 1.06-1.07 180-250 PA/NYLON 1.08-1.17 230-290
H.P.S 1.05-1.08 220-280 NYLON66 1.03-1.15 280-330
L.P.S 0.91-0.93 150-260 PVC/S 1.20-1.40 150-180
H.P.E 0.94-0.96 190-260 PVC/H 1.30-1.58 160-200
P.P 0.98-0.90 200-290 P.E.T 1.38-1.41 280-310
P.C 1.2-1.22 280-320 P.T 1.41-1.52 220-280
P.O.M 1.41-1.42 190-230
R
PORCHESON
32
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

20. Hot runner temp setup information

温 度
TEMP.
Pres s key twice , ent er ent er into the page of hot runn er temp setup, and page will be as follow:

temperature test Hot runner temp setup 10:07:12

hot runner heating Open electric heat status Close


Ek0 Ek1 Ek2 Ek3 Ek4 Ek5 Ek6 Ek7 Ek8 Ek9 Ek10 Ek11
Actual ****** ****** ****** ****** ****** ****** ****** ****** ****** ****** ****** ******
Display ****** ****** ****** ****** ****** ****** ****** ****** ****** ****** ****** ******
Setup ****** ****** ****** ****** ****** ****** ****** ****** ****** ****** ****** ******
max limit ****** ****** ****** ****** ****** ****** ****** ****** ****** ****** ****** ******
mini limit ****** ****** ****** ****** ****** ****** ****** ****** ****** ****** ****** ******

Hint:range:0.00~99.99
Machine Run Well mold close slow

Descriptions on setting parameters/ process/function mold


Attent ion:the mold temp cont rol funct ion provi des 12- section temp hea ting

R
PORCHESON
33
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

21. Set warm-up information

温 度
TEMP.
Press key three times , enter the menu for setting warm-up information , now the menu
is as following:
2016-05-18 Warm-up setup 16:40:30

Pre-heat function Enable

Week Monday Tuesday Wednesday Tursday Friday Saturday Sunday


boot starts setup ON OFF OFF OFF OFF OFF OFF
boot time 13.00 00.00 00.00 00.00 00.00 00.00 00.00
power off setup ON OFF OFF OFF OFF OFF OFF
power off time 13.00 00.00 00.00 00.00 00.00 00.00 00.00

Hint:machine runs well

Description on setting parameters


Warm-up function: Can set a time for seven days a week in advance. The system controls the heating system
to heat through the set value of the intraday [on]/[off] time. The system heats automatically the hopper to
working temperature before operator comes to the office. The operator's waiting time for heating hopper
is decreased.
*[note]: The input value of time adopts the input value of 24 hours system. 00:00 is 12: 00 Midnight.

R
PORCHESON
34
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

22. Set mold data information

资 料
DATUM
Press key, enter the menu for setting mold data information, now the menu is as following:

2016-05-17 mold data setup 14:30:52

mold number 0 Read Save Delete initial sequence no 1


mold name A Cup englsih type-in up page Next

mold view
Mold number mold name saving date
0 A Cup 2016-6-10 14:38:52
1 B Cup 2016-6-07 13:39:52
2 C link 2016-6-06 13:30:52

Descriptions on setting parameters/ process/function mold

(1).Mold number: this system can store 10 mould numbers. The system can provide automatically
the information of the modified mold number after they have been modified.
(2).How to store mold: Move cursor to the box of mold numbers, key in the mold number; and than
move the cursor to the box of the name of the mold, key in the name of the mold; this system
provides the input mold with English/Chinese phonetic alphabet; move the cursor tobox of
storage after the name has been keyed in and than press [enter] to store the name.
(3).How to get mold: Move cursor to the box of mold numbers, key in the mold number that will
be read out, move the cursor to the box of reading out, press[enter]to read out. The functions
of getting mold is limited within manual mold to prevent accident occurs; in the semi-auto/auto
mold, the accident is caused by the influence of bad products, which comes from the sudden
varying of the set parameters in the menu.
(4).How to delete: Move cursor to box of mold number, key in the mold number that will be
deleted, and than move the cursor the box of deleting, press the [enter] to delete. The current
mold number can not be deleted.
(5). View method:a:move cursor to the up and down button to view,b,[initial sequence
no display] :to locate by initial sequence no.and then use the up and down key to view.
(6) Mold no.1 as standard mold parameter and this is system self-own so no need to be stored,
and when need to be stored change mold num ber

R
PORCHESON
35
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

23. Amendment history information

资 料
DATUM
Press key twice, ent er the menu for amend history information, now the menu is as following:

2016-04-17 amend ment history 14:30:52

record times 3 display initial sequnce no 3 up page down page del ete
No uder ID amend tim e amend picture amend project original value amend value
14:38:52 Mold close middle speed 0.00 9.00
13:38:52 Hold pressure low pressure 0.00 30.00
12:38:52 Mold open 3Level Pressure 0.00 20.00

Descriptions on setting parameters/ process/function mold

(1).Page number: This screen can keep at most 999 items of records,
(2). View method:a:move cursor to the up and down button to view,b,[initial sequence
no display] :to locate by initial sequence no.and then use the up and down key to view.

R
PORCHESON
36
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

24. Set special parameters information

Press 1 STU key , enter the menu for setting special parameters, now the menu is as following:

2016-04-17 special parameters setup 14:30:52

special parameter Machine maintenance schedule

language selection Machine parts information


Product problem analysis
Ethernet
Middle pump 30.0 %
user management
MC600+M K320[ 800X480]
user login list PS magic 3.19

Hint:set range:0.0~99.9

(1) Mid / big pump start: when the setup executive action flow value is bigger than the setup mid/
big pump flow output value, the mid/big pump output point will have output.
(2) Move the cursor to select the [special parameters>>] button, press the input button, a new page
will pop up. At this time, the screen displays as follows:

System menu Next


IP para State
special parameters setup sales log in scheme 1

LCD contras t Adjustm ent 30 sales log in scheme 2


LCD brig htness adjustm ent 80 Sales loading
LCD color setup Normal scheme slection
LCD backlight time 6 remove setup of machine halt function
Function of key sound Enable network connection status
sound volume adjustment 6 Current IP:192.168.0.1
TouchPanel Correction Test Current state:connect

(2a) Adjustment of LCD contrast: move the cursor to this place, input the data [adjustment range
"1-100%"]. Under appropriate brightness, the higher the contrast is, the richer the color will
be (Note: when LCD is the STN screen, it can be valid).

R
PORCHESON
37
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

(2b) LCD brightness adjustment: move the cursor to this place, input the data [adjustment range
"1-100%"] , the screen will display the darkness & brightness degree according to the data entered.
(2c) LCD color setup: the system can provide [normal/anti-color] two options, move your cursor
to this place, press [input] button to select LCD color display.
(2d) LCD backlight time: the system has the function of screen protection, the background light
time is adjustable, the setup scope is 1~6 minutes. If the keyboard is not pressed in the setup
time, the background light will be automatically turned OFF. (Note: if any button is pressed,
background light will be on)
(2e) Function of key sound: Select [use], you will hear a "tick" sound when the key is pressed, if
do not select, no sound.
(2f) Key sound scope: move your cursor to this place, input the data[scope "0-10"]to adjust voice
volume.
(2g) Correction of Touchscreen: click on the [Correction] button to enter the correction page (Note:
only if keyboard has the touch function, the correction can be valid)
(2h) Network connection status: the network connection status is indicated with colors.
(2i) Current IP: show the IP address of the machine.
(2j) Current connection state: show the network connection status: disconnect / connect.
(3) Move the cursor to select[language conversion>>]button, press the input button, a new page
will pop up. The screen displays as follows:

System language Return

Chinese English

Japanese Korean

Vietnamese Russian

Spanish Turkish

Italian The Arabic language

(4a) Language options: the system provides [Chinese / English / Russian /Japanese]the four language
options, move the cursor to this place, press the [input] button, you can carry out the conversion.
(Note: the language categories of the system can be set up by users)

R
PORCHESON
38
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

25. Set Ethernet information

Move the cursor to select [Ethernet] button, press the enter button to eject a new page, which
will display the following information:

Ethernet/ CAN-Bus Configurat ion Return

Ethernet Setup CAN Setup


Ethernet Use Own ID 1 500 Acceptance ID 1 600
Remote Update OPWIN Allow Acceptance ID 2
Own ID 2 0 0
IP 192.168.0.250
Own ID 3 0 Acceptance ID 3 0
Mask 255.255.255.0
Gateway 192.168.0.1 Own ID 4 0 Acceptance ID 4 0
MAC FF:FF:FF:FF:FF:FF Own ID 5 0 Acceptance ID 5 0
Revise Revise

Parameter Setup Instructions


(1) Ethernet: With the remote communication function, the user can prepare programs and change
different versions of software remotely. The network connection software provided by us allows
the network connection and management of 255 injection molding for production machines
by one PC host and the production of each machine can be calculated accurately and production
data can be printed and managed conveniently.
(2) Remote OPWIN Update: The update item can be respectively set as [Allow/Forbid], choose
[Allow] to prepare programs remotely and change different versions of software and conduct
system program updates.
(3)CAN_bus: Such setup can realize the function of one keyboard connecting with multiple hosts.
Note:
a. The above revised parameters will not come into effect unless the cursor moves to [Revise]
for confirmation and a restart is made.
Method for ethernet PLUG switch to aviation plug

0
J1 A+
J1 A+(salmon pink ) ETHER_D0_P
0 ETH_GND
J2 A- J2 A- ( orange ) I ETHER_D0_N ETH_GND
1 A+/TX+ 1 nETHER_D0_P
J3 B+ J3 B+(green-white ) ETHER_D1_P 2 nETHER_D0_N
J6 B- ( green ) ETHER_D1_N 7 A-/TX-
J4 C+ 2 B+/RX+ 3 nETHER_D1_P
J4 C+ ( blue ) ETHER_D2_P plug pin sequence --corresponding 8 6 nETHER_D1_N
B-/RX-
J5 C- J5 C- ( blue-white ) ETHER_D2_N
6 C+ 4 nETHER_D2_P
J6 B- J7 D+ ( browntong ) ETHER_D3_P 5 nETHER_D2_N
J8 D- ( brown ) ETHER_D3_N 3 C-
J7 D+ 7 nETHER_D3_P
D+ 8 nETHER_D3_N
4 5 D-
J8 D-

( 8 pin avation plug and PLUG definition )


( 8 pin avation plug and PLUG definition )
Wire requiremnt:0M/100M/1000M completely compatible
( Front Avation plug pin )

R
PORCHESON
39
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

(4)User management data setup:move cursor to press【user management】button and then


the page will be as below:

User manage Return


Add Modify Delete Login Record NO 1 Current user No user login in

Page NO OFF Muit-use Login Boot login OFF

SN User ID Card ID User name Level Save date Modify date

(4a)Multi-user function:There are 【close】【open】available,use password to log in when


select to close,and use magcard when select to open.
(4b)Listing:Show all users information:User ID
(4c)Add modification delete three functions available
(4d)Click add and then the following chart will be popup
Add new u ser Return

loading type Password Magcard Password+Magcard


user name Spell type-in
Authority level Operator

new account no ***** magcard card registration


input password ***** new magcard ID
password confirm *****
Confirm (Y) Confirm (Y)

Hint...loading... Hint...loading...

operation over

password to log in 【password】mode;and use cagcard to log in in 【cagcard】mode,and use


password or cagcard in 【password or cagcard】mode.
ab、User name:shows
、Loading type:There user
are information
【password】 【magcard】【password or cagcard】available,use
c、Authority level:There are 【operator】 【management】 【technician】 【dept manager】
【technical engineer】or【system management】options available which is to meet different
category peoples demand of management.

R
PORCHESON
40
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

d、 new account no: means the account no for log in


e、 input password:means the password no for log in
f、 Password confirmation:input the password again to confirm its accuracy
g、 New account no confirmation:after done data input press this button to be listed。
h、 Magcard card registration:use magcard to punch NFC(within 2cms)and hold 2 seconds,
punch again when heard the sound of Di and see the hint:punch again,please .
Then remove the card beyond 10cms over NFC and then move back punch again,the data
collection is finished when heard the sound of Di,finally move cursor to confirmation to
press it.
(4e) Press Enter button when password﹑

Modificati on u ser Return

loading type Password Magcard Password+Magcard


user name Spell type-in
authority level Operator

new account no ***** magcard card registration


input password ***** new magcard ID
password confirm *****
Confirm (Y) Confirm (Y)

Hint...loading... Hint...loading...

operation over

a、User serial number:input the serial number which need to revise,all user data can be changed
based on their actual need,and for how to input data please refer to Way of adding new user.
(4f) Click delete and then the following chart will be as below..

Delet e User Return

single operation lot operation

user sequence no 1234 user sequence no 0 0


user name

Confirm (Y) Confirm (Y)

Hint...loading... Hint...loading...

R
PORCHESON
41
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

a、User deletion:single operation﹑;continuous users will be deleted in bulk operation


mode(prudent operation)
5.user list
User manage Return

Page NO OFF Muit-use Login Boot login OFF

SN User name Level Enter date/time Log-on date/time Running time Output count

a、 Use to record all user data,user name,authority level,loading date,cancellation date,run


time and production during period.

R
PORCHESON
42
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

26.MES---setup of injection molding workshop management system(optional)


MES
Press key four-time(MK310,MK320 and MK330)or press key(MK360)
and then MES--function page will be showed as below:
2016-05-17 MES functions selection 14:30:52
Selection of production type
Selection of Production order Number
Production finished
Selection of machine halt types
Quality management
Sub-order
MES function Enable
After selecting MES function,please select [Production type] and next
select [Production Order No. ] before enter into automatic production,
otherwise unable to enter into [Automatic Mode]
production types Production Order No Production finished machine halt types Quality management Sub-order Monitor

2016-04-17 MES Production type selection 14:30:52


production type 0 execute or not Not Current production types 1
Number Type
1 Production by orders
2 Production over machine adjustment
3 Production without orders
4 Production at abnormal status
5
6
7
8
9
Production type,Production Order No. are to proceed at manual mode.
production types Production Order No Production finished machine halt types Quality management Sub-order Monitor

Description on setting parameters

(1)MES function selection: [Enable], [Disable] option, machine is in MES management mode while
select [Enable],conversely,it is in Standard mode.
(2)Production type selection:[ Production by orders] [Production over machine adjustment] [Production
without orders] [Production at abnormal status].Opertional method:Please input production types of
sequence no. .in [Production types selection]based on actual situation,next select[YES] on [Execute
Or not ],.after successful execution,chosen,sequence will be displayed on [Current production type]
Notice:MES function is only available for keyboard with Ethernet function.

R
PORCHESON
43
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

2016-05-17 MES Production Order No selection 14:30:52


Production Order No 1 execute or not Not Current production Order No 1
Shift Order No production No Mould No
Number Status Start time Finish time Pre-Production Q. Produced q. Defected q.
Day shift PD-201305154-0001 QS196-CCF 1968-8-6
1 No P. 7000 0 0
Night shift
2 No P.
3 No P.
4 No P.
5 No P.
Hint:
production types Production Order No Production finished machine halt types Quality management Sub-order Monitor

2016-05-17 MES Production finished 14:30:52


current production type 1 advanced warning function Use
current production no 1 advanced warning mould 0
Pre-production quantity is reached,continue or stop Not === Warning time 0
continue to produce 0
Pre-production quantity is reached,continue or stop Not ===

Pre-Production mould NO(mould) MES Pre-Production quantity NO(number) Defected quantity NO(number)
2100 0 0
MES Pre-Production quantity NO(number)
Output number(mould) One mould (number) Produced quantity (number)
2100 5 0
This page is only valid when production is reached set qty and ?production by order

Hint:
production types Production Order No Production finished machine halt types Quality management Sub-order Monitor

Description on setting parameters

(1)、Selection of Production order No.: The choose of Production order No. Can not be empty when [Selection
Of production types] is [Production by orders].Please choose the order NO. That need to be produced according
to actual production situations ,and the operation method please refer to [Selection of production types.]
(2)、Production termination:When [Selection of production types] is [production by orders]and[output was
reached set pont] ,the following page will be automatically jump out while alarming such as: [finish this
order] or [continue to production] and [continue same production output ] ,choose one of the two.Please
choose[termination]when the set output of this order is being reached,and if want continue to production
then the needed produced output must be input first and next choose [continue to production].

R
PORCHESON
44
User's Manual for MK3XX V1.0 Chapter 3: Descriptions on setting parameters/functions

2016 -05- 17 MES machine halt types selection 14: 30: 52


machine halt types 1 execute or not Not Current machine halt types 1

Number Status of machine halt Number Status of machine halt


1 Arlam 11
2 change mould 12
3 change order 13
4 change material 14
5 adjust machine 15
6 Maintenance 16
7 Plan 17
8 Repair 18
9 19
10 20

production types Production Order No Production finished machine halt types Quality management Sub-order Monitor

2016 -05- 17 MES Quality management selection 14: 30: 52


Complement No. of order 1 execute or not Not Complement No. of order 1

Shift Order No
NO
NO Defected reasons NO Defected Qty Pre-set produced quantity inferior product
1 11
1
2 12
3 13
2
4 14
5 15
3
6 16
7 17
4
8 18
9 19
5
10 20

production types Production Order No Production finished machine halt types Quality management Sub-order Monitor

2016 -05- 17 Sub-order 14: 30: 52

NO 1 2
Sub-order no 0 0
production status to be in production to be in production
pre- product ion sub- order qty 0 0
completed sub-order qty 0 0
total finished mold 0 0
next sub-order pre-production qty 0 0

production types Production Order No Production finished machine halt types Quality management Sub-order Monitor

Description on setting parameters

(1) Selection of machine halt types: Please select reasons of machine halt by jumping out of this page when
changing automatic mode to manual mode under manual status.
(2) Quality management: ,input defected quantity into corresponding order form based on orders,so good
products quantity are able to supplement in time during production to insure pre-set good ones.

R
PORCHESON
45
User's Manual for MK3XX V1.0 Chapter 4 production management

Chapter 4 production management


1. Set production Imformation
生产管理

Press FLOW CHART key , enter the menu for setting production information, now the menu is as following:
2016-05-17 production management 14:30:52
Setup mold number one mold number Output number Good produ ct inferior product
4000 4 1000 3900 100
Qt y re se t Warning initial sequence no
OFF Disable 0 Next Return record clear

NO Date number Output number Good produ ct inferior product


1 08-15 10:16 4 1000 3900 100

Hint:0.OFF 1.ON
production management production monitor SPC Tracing record incident track back

Description on setting parameters

(1) The quality products equal to the number of the opened mold times the amount of one mold minus
rejects. The rejects are controlled through ejecting testing function. When ejecting testing function
is on, just like in stroke. When too much or too less stuff occurs, the rejects will increase amount
value of one mould, and [Failure of plastic] alarms.
(2). Set mold numbers: In the mold numbers setting of pre-production, the system starts alarming when
the number of mold opening arrives at the first 5 molds till it reacheded The set output .
(3). Warn Stop : [On] or [Off] can be selected. It will continue producing even arrives at the set mold
number if [Off] has been selected till an operator stops it.
(4). View method:a:move cursor to the up and down button to view,b,[initial sequence
no display] :to locate by initial sequence no.and then use the up and down key to view.
生产管理

Attention:Press FLOW CHART


key continuously to change production management page.

R
PORCHESON
46
User's Manual for MK3XX V1.0 Chapter 4 production management

2. The output statistics iformation


生产管理 射 出
INJECTION
Press FLOW CHART key to enter into flow chartand then Press key enter the output statistics ,
now the menu is as follows:
2016-05-17 Output statistics 14:30:52

Search/Delete
Last day Clear intra date
Seach date 2016-06-29
Total 102 Next day Clear all

00-01 0 06-07 0 12-13 0 18-19 0


01-02 0 07-08 0 13-14 0 19-20 0
02-03 0 08-09 0 14-15 0 20-21 0
03-04 0 09-10 0 15-16 0 21-22 0
04-05 0 10-11 0 16-17 0 22-23 0
05-06 0 11-12 0 17-18 0 23-24 0

Hint:setup :0~100
production management production monitor SPC Tracing record incident track back

Description on setting parameters

Computer provides function for production output statistics,system automatically record for
past 15 days(per hour/per day production)
(1) Inquiry/elimination: There are [Able]/[Disable] optional. Move cursor to [the day before],[the
next day] and press [ENTER]to check the production data of the the day before or the next day;
move cursor to [clear intraday output] and then press [ENTER] key to delete the query date output
data,move cursor to [clear all data]and press [ENTER] key to delete all production output data.

生产管理

Attention:Press FLOW CHART


key continuously to change production management page.

R
PORCHESON
47
User's Manual for MK3XX V1.0 Chapter 4 production management

3. SPC Tracing record imformation


生产管理

Press FLOW CHART key three times, enter the into SPC Tracing record page which be as following:
2016-07-17 SPC tracing record 14:30:52
intermittent cycle 0 cycle 999 record item number 1 Page up Page down clear
NO Date Number Cycle Hidtrans Hidtrans Hidplace Use Fed place Hid place Mid open pl

10:16 1 15.16 0.50 0.50 0.50 0.48 50.05 50.05 50.05 50.05

Clear record Max value


Min value
average value
Deviation
Hint:setup :0~100
production management production monitor SPC Tracing record incident track back

Description on setting parameters

(1). Record: the pagel has up to 999 pages, containing the consecutive information of the 999 modules.
The SPC Tracing record system can provide up to 7 important parameters of the latest 999 modules.
The operator can scroll up and down between page 1 and page 10 to manage the production of
The modules. By using the system, the operator will be able to have more insight of the actual
Variation of the important parameters and take specific and proper actions to adjust the system's
operation and improve the quality of the product as a result.
(2).Intermittent cycle: record the data once every several cycles.
(3). View method:a:move cursor to the up and down button to view,b,[initial sequence
no display] :to locate by initial sequence no.and then use the up and down key to view.
生产管理

Attention:Press FLOW CHART


key continuously to change production management page.

R
PORCHESON
48
User's Manual for MK3XX V1.0 Chapter 4 production management

4. The Incident track back page


生产管理
座台/调模
Press key to enter into flow chart and then press key to enter Incident track
NOZZ/ADJ.
FLOW CHART

back page which will be as below:

2016-07-17 SPC tracking record 14:30:52

record data 0 display initial sequence NO 1 Page up Page down record clear

NO User ID Alarm time Open mold Number Incident


10:16 1 15.16 1 500.1

Hint:setup :0~100
production management production monitor SPC Tracing record incident track back

Description on setting parameters

(1).Display: there are 999 alarm records to be checked which provides convenience For equipment
maintenance/repairing.
(2). View method:a:move cursor to the up and down button to view,b,[initial sequence
no display] :to locate by initial sequence no.and then use the up and down key to view.
生产管理

Attention:Press FLOW CHART


key continuously to change production management page.

R
PORCHESON
49
User's Manual for MK3XX V1.0 Chapter 4 production management

5. The injection curve page


曲 线
Press key to enter into flow chart and then press 开锁模 key to enter injection curve
CURVE M.PLT
page which will be as below:

Maxi mum 0 mm/s Injection curve 14:3 mm


Repeat 1 Max .pressure 6 Bar inject pressure setup curve Display inject speed setup curve Display
Clear Max.speed 140.0 Mm/s Real-time curve(pressure) Display inject speed real-time curve Display

Injection curve real time curve History curve tracking curve temperature monitor speed curve

Description on setting parameters

(1)Repetition times:accpetable to 1--4times.It will dispaly the latest curve data when selected one
time,and it will display the last 4 times? cruve data once 4 times is selected。
(2)max pressure:the setup curve that the max pressure of left Y axis
(3)max speed:the setup curve that the max speed of left Y axis
(4)Pressure setup:[displayed] 【not displayed】optional.Pressure curve will be displayed,not
displayed on the contrary,It can be displayed six curves at the same time.

曲 线

Attention:Press CURVE key continuously to change curve management page.

R
PORCHESON
50
User's Manual for MK3XX V1.0 Chapter 4 production management

6. The servo -real time curve page


射 出
Press key to enter into curve management,then Press INJECTION key enter the actual curve page ,
now the menu is as follows:
2016-05-17 Servo-real time curve 14:30:52
sampling cycle 0.1 amplification factor 6 Pressure set. Display flow setup Display Output Current Display
left axis max 0.1 Bar right axis max 140.0 % Pressure Feedback Display flow feedback Display motor speed Display
movement selection Injection Repeated times 4 % Clear

Injection curve real time curve History curve tracking curve temperature monitor speed curve

Description on setting parameters

(1)Movement selection:there are "injection,'feeding",mold-clamping,mold-opening"available.


When injection was chosen.
(2)Repetition times:accpetable to 1--4times.It will dispaly the latest curve data when selected one
time,and it will display the last 4 times? cruve data once 4 times is selected。
(3)Sampling cycle:the frequency that curve data adopts namely the interval time range:0.1s--1.0s)
(4)Left axis max:the setup curve that the max pressure of left Y axis
(5)Right axis max:the setup curve that the max percentage of right Y axis
(6)Pressure setup:[displayed] 【not displayed】optional.Pressure curve will be displayed,not
displayed on the contrary,It can be displayed six curves at the same time.
曲 线

Attention:Press CURVE key continuously to change curve management page.

R
PORCHESON
51
User's Manual for MK3XX V1.0 Chapter 4 production management

7.the History curve page of servo page


储 料
FEEDING
Press key to enter into curve management and then press key to enter the curve
page of servo history which the page will be as below:
2016-05-17 The servo historyCurve 14:30:52
Sampling cycle 1 Magnifica 1 Pressure Display Flow rate Display Output current Display
Left axis max 1 Bar Right axis max 1 Feedback Display Pre.feed Display Motor speed Display
Data collection Start Clear record

Injection curve real time curve History curve tracking curve temperature monitor speed curve

Description on setting parameters

(1)Data collection:There are 【start】,【stop】available.Data collection be started,when selects


【start】,on the contrary,data collection will be stopped.
(2)Sampling cycle:the frequency that curve data adopts namely the interval time range:0.1s--1.0s)
(3)Left axis max:the setup curve that the max pressure of left Y axis
(4)Right axis max:the setup curve that the max percentage of right Y axis
(5)Pressure setup:[displayed] 【not displayed】optional.Pressure curve will be displayed,not
displayed on the contrary,It can be displayed six curves at the same time.
曲 线

Attention:Press CURVE key continuously to change curve management page.

R
PORCHESON
52
User's Manual for MK3XX V1.0 Chapter 4 production management

8.the temperature tracking curve page


座台/调模
NOZZ/ADJ.
Press key to enter into curve management,then Press key enter the tracking curve page ,
now the menu is as follows:
2016-05-17 Temp. tracking curve 14:30:52
Selection of display Nozzle

Injection curve real time curve History curve tracking curve temperature monitor speed curve

Description on setting parameters


(1) Selection of display which is the historical tracking curve for checking on certain sections of temperature,
temperature historical tracking record function of the system can provide the first 6 hours historical parameters
for 6 sections of temperature and that enable operators master the change of machine actual inspection
temperature better that lead to operators are able to make a comparison and analysis of affect to product quality
by temperature.
(2) Interval of sampling record: the time for sampling record interval ,5 minus.
曲 线

Attention:Press CURVE key continuously to change curve management page.

R
PORCHESON
53
User's Manual for MK3XX V1.0 Chapter 4 production management

9.the temperature monitor page


托模/中子
Pres s key to ent er into curve managem ent and then pres s EJE/CORE key to ent er the tempera ture
monit or which the page will be as bel ow:
2016-05-17 temperature monitor 14:30:52

Eject Seg1 Seg2 Seg3 Seg4 Seg5


Meas 31.8 31.8 31.8 31.8 ****** ******
Set 5.0 5.0 5.0 5.0 ****** ******
State Well Well Well Well ****** ******
Set 300
Meas
200

100

5.0
Eject Seg1 Seg2 Seg3 Seg4 Seg5
Hint:setup :0~100
Injection curve real time curve History curve tracking curve temperature monitor speed curve

Description on setting parameters

parameter setup instruction:


(1) . use bar chart to show the relationship between actual temperature and setup temperature
(2). show the heating output situation ,actual value ,setup value and status of every section of
temperature
曲 线

Attention:Press CURVE key continuously to change curve management page.

R
PORCHESON
54
User's Manual for MK3XX V1.0 Chapter 4 production management

10.the injcetion speed curve page


时 间
TIME
Pres s key to ent er into curve managem ent and then pres s key to ent er inject ion speed
curve the page will be as bel ow:
2016-05-17 Injection Curve 14:30:52
Action selection Injection Sampling cycle 0.02 sec Max. Speed Injection mm/s Injection speed 0 mm/s
Manificatio n 1 Max. press 250.0 bar max. Press 1 sec Max num. 0.0 bar
Left Y axis max 1 % Right Y axis max 800.0 mm screw position 14.3 mm

Injection curve real time curve History curve tracking curve temperature monitor speed curve

Description on setting parameters

(1).Mov ement selection:there are "injection,'feeding",mold-clamping,mold-opening"available.


When injection was chosen.
(2). Sampling cycle:the frequency that curve data adopts namely the interval time(range:0.1
s--1.0s)
(3).Left Y axis max:the setup curve that the max pressure of left Y axis
(4).Right Y axis max:the setup curve that the max percentage of right Y axis
(5). max speed: max speed of linear scale variation,this percentage data which is use current collected
vary speed of to compare with max speed, range 1---60000
(6).max speed: max displayed pressure value,this percentage data which is use current collected
actual pressure to compare with max pressure,range 0---250
(7).X axis is the biggest;setup the longest time for curve X axis
曲 线

Attention:Press CURVE key continuously to change curve management page.

R
PORCHESON
55
User's Manual for MK3XX V1.0 Chapter 4 production management

11. USB setting page (for options)

PC连接

Press PC LINK key; enter USB setting page. and it is as follows:

USB set RETURN ENGINEER


System USB up/download option
Data operation: download data area:system program
Update area : Upload Download start D: 0 Upda te OPW IN.PS6 : Update
System: Upload Download Finsh D: 0 Upda ta autobuild file : Update
Host burner: Burner System-v: 5.3.26 update start background file : Update Update
Opwi n-v: 5.28 Progr am Factory Standard
Movable deposit dist (USB)
.. PS860.PIN
OPWIN.PS6

Parameter setting introduction


(1) Formula downloading: download the mold data from control system of jet injection machine
to the USB of moveable disc.
(2) Formula uploading: upload the mould data from the USB of moveable disc to control system of
jet injection machine; at the same time the data will overlay previous data correspondingly.
(3) System downloading: download the mold data from control system of jet molding machine
to the USB of moveable disc.
(4) System uploading: upload the mould data from the USB of moveable disc to control system of
jet moulding machine; at the same time the data will overlay previous data correspondingly.
(5).Start/End D: when you are downloading the material of [formula] and [system], please designate
the scope of the downloading data .
(6).Mainframe replication: means updating the host procedures. First, press the stop button on the
keyboard, then move the cursor to [replication], press the enter button and move the cursor to
select [. Pin] files and update it.
(7).Update OPWIN.PS6: means updating the keyboard procedures. Move the cursor to [update],
press the enter button and move the cursor to select [. PS6] files and update it.
(8).System value backups:【factory value】【standard value】.factory value comes from system
backups(can be backuped based on customer’s demand).Standard value comes from system self
-own parameters(fixed parameters can not be modified)
(9). Frames activated setup as below:
(a).Picture play function:【Disable】【Able】optional.Normalpage will be displayed after
system booting when selects【disable】;and photo will be played after system booting when
selects 【Able】

R
PORCHESON
56
User's Manual for MK3XX V1.0 Chapter 4 production management

Selects 【addition】 ;new photo will be added after deleted all exist photos when selects
(b) photo uploading:【addition】、【replacement】optional.Only new photo will be added when
【replacement】
(c) Entering into normal page: 【counting reached】 、 【input】optional.One photo will be
automatically displayed after every interval time in [counting reach] mode;photos will be
automatically played in turn after every interval time in [input] mode and then press [input] key
to enter into normal page.
(D)photo message
Limit number:maximum 5 pieces of photo
Picture format:bmp only at present
Upload:the photo number which has been uploaded
Upload balance:the photo number which uploaded balance
LCD resolution ratio:max resolution ratio of photo

Picture setup Return

photo functi on setup


Picture play function Disable Able
photo uploading Addi tion Replacement
enter into normal page Count ing Input
Loop playback times 1 interval time 1
photo message

Limit number: 2 Pictu re format: BMP


Upload: 2 Upload balan ce:2
LCD reso lution :1024*768

R
PORCHESON
57
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

Chapter 5 Instructions for the System Commissioning Settings


1. Engineer Setting Page

Press 0 [ ]/-. Key the Main Page to enter the Engineer Setting , and the following will be displayed:

2016-05-17 Engineer setup 14:30:52

F1 delay setup
cancellatin of log in
F2 Pressure /flux slope
Machine NO
F3 Pressure/Flow/Back pressure pre-adjustment Ma300
F4 Electronic ruler Controller NO
F5 sepcial Function setup PS860AM MK310

F6 Standby Function / Programmable Standby Software version


V2.0
F7 Temperature Parameter
F8 Machine No / Ex-FactoryValue Setting

Enter the password * * * *.If the password entered is correct, you can enter the system parameter
setting page. It is not Necessaryfor the equipment end-user to adjust the system parameters.
Please consult the equipment manufacturer for any query. Any parameter adjustment disorder
may result in damage to equipment capability,unstable performance or failure to operate.
After the correct password is entered, the cursor jumps automatically to the first item from
the right. The cursorcan be moved to different items and then Key is pressed to enter

the corresponding pages. Alternatively, you can press the following keys 输 入 to enter directly
ENTER
the corresponding pages:

Key Entering Page Key Entering Page

开锁模 托模/中子
<Delay Setup> <Standby Function Setting>
M.PLT EJE/CORE

射 出 <Pressure/Flow Setting I> 时 间 <Programmable Standby


INJECTION
<Pressure/Flow Setting II> TIME Points>

储 料 <Pressure Pre-Adjustment> 温 度
<Temperature Parameter>
FEEDING <Flow Pre-Adjustment> TEMP.

座台/调模 资 料 <Machine No./Ex-Factory


<Special Function Options>
NOZZ/ADJ. DATUM Value Setting/Time Setting>

R
PORCHESON
58
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

2. Delay Setting Page


开锁模
M.PLT
Entering Engineer Setting Page, press Key enter the Delay Setting Page. The following is
displayed:
Next Action delay Setup Return Engineer
screw speed 0.1 RPM output current 0.1 mA
Begin Action End Begin Action End Begin Action End
0.1 Mold close 0.1 0.1 Ejector advance 0.1 0.1 Core B in 0.1
0.1 Nozzle advance 0.1 0.1 Ejector return 0.1 0.1 Core B out 0.1
0.1 Inject 0.1 0.1 Mold thin 0.1 0.1 Core C in 0.1
0.1 Feed 0.1 0.1 Mold thick 0.1 0.1 Core C out 0.1
0.1 suck back 0.1 0.1 Core A in 0.1 0.1 Core D in 0.1
0.1 Nozzle return 0.1 0.1 Core A out 0.1 0.1 Core D out 0.1
0.1 Mold open 0.1 0.1 Differential 0.1

Hint:set range:0.0~0.5
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

开锁模
Entering Engineer Setting Page, press M.PLT Key twice to enter the Delay Setting Page.The following
is displayed:
Next Time Delay Setup Return Engineer

Mold close delay 0.1 Core A in delay 0.1


Nozzle advance delay 0.1 Core A out delay 0.1
Injection delay 0.1 Core B in delay 0.1
Feed delay 0.1 Core B out delay 0.1
Suck back delay 0.1 Core C in delay 0.1
Nozzle return delay 0.1 Core C out delay 0.1
Mold open delay 0.1 Core D in delay 0.1
Mold open to ejector 0.1 Core D out delay 0.1

Hint:set range:0.0~2.0
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Setting delay between actions


delay time T1 → pressure output ON
(1) The meaning of Start Delay: the
corresponding action valve ON →
flow output ON
pressure output OFF
(2) The meaning of End Delay: the
→ → delay time T2→ action valve OFF
corresponding action valve
flow output OFF

R
PORCHESON
59
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

3. Pressure/Flow Slope Setting Page


射 出
Entering Engineer Setting Page, press Key INJECTION once to enter Pressure/Flow Slope Page I.
The following is displayed:
Next Flow Slope Setup 1 Return Engineer

slope master calibration Action P F Action P F


slow mold close 16.0 16.0 ejector return 16.0 16.0
slow mold close Fast mold close 16.0 16.0 Core A in 16.0 16.0
2.0 S Low mold close 16.0 16.0 Core A out 16.0 16.0
high pressure mold close 16.0 16.0 Core B in 16.0 16.0
Slow mold open 16.0 16.0 Core B out 16.0 16.0
Fast mold open 16.0 16.0 1 Level Injection 16.0 16.0
Middle mold open 16.0 16.0 2 Level Injection 16.0 16.0
Low mold open 16.0 16.0 3 Level Injection 16.0 16.0
Ejector advance Fast 16.0 16.0 4 Level Injection 16.0 16.0
Ejector advance slow 16.0 16.0 5 Level Injection 16.0 16.0

Hint:set range:1.0~16.0
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

射 出
Entering Engineer Setting Page, press Key twice to enter Pressure/Flow Slope Page II.
INJECTION
The following is displayed:

Next Flow Slope Setup 2 Return Engineer

Action P F Action P F
1 Level hold pressure 16.0 16.0 Mold thin 16.0 16.0
2 Level hold pressure 16.0 16.0 Mold thick 16.0 16.0
3 Level hold pressure 16.0 16.0 Core C in 16.0 16.0
4 Level hold pressure 16.0 16.0 Core C out 16.0 16.0
Front Suck back 16.0 16.0 Core D in 16.0 16.0
1 Level feed 16.0 16.0 Core D out 16.0 16.0
2 Level feed 16.0 16.0 Standby
Back Suck back 16.0 16.0 Standby 1.0 1.0
Nozzle advance 16.0 16.0 Standby 1.0 1.0
Nozzle return 16.0 16.0 Standby 1.0 1.0

Hint:set range:1.0~16.0
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Description on setting parameters


The Pressure/Flow Slope refers to the steep degree of rise or fall when the pressure/flow
changes from one value to the next value. "0.1 stands for the slowest change and "16.0 stands
for the fastest change. The setting range is .[0.1-16.0].

R
PORCHESON
60
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

4. Pressure Pre-Adjustment Page


储 料
Entering Engineer Setting Page, press FEEDING Key once to enter the Pressure Pre-Adjustment
Page.The following is displayed:
Next Pressure Pre-adjustment Return Engineer

minimum current Pre-adjust Disable 80 23993 OFF


1000 OFF
1 1 90 26992 OFF
Flow pre-adjust
10 3000 OFF 100 29991 OFF
90.0 %
initial data 20 5999 OFF 110 31199 OFF
OFF 30 8998 OFF 120 33128 OFF
output current 40 11997 OFF 130 39997 OFF
0 mA 50 14996 OFF 140 44996 OFF
60 17995 OFF 150 47995 OFF
70 20994 OFF 160 48000 OFF

Hint:set range:0~65535
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Description on setting parameters

The pressure pre-adjustment is the linear adjustment of pressure output. In general, the standard
pressure is 0-800mA and the standard output impedance is 10-20Ω,unless the manufacturer
has specific requirements since different manufactures' overall oil piping designs and the
capabilities of the pressure proportional valve being used are different.
Pressure Adjustment Method:
The parameters on this page have been set before ex-factory. If the capability of the proportional
valves being used by the user is different, and the normal proportion and linear proportion cannot
be achieved, the parameters on this page can be adjusted. First set the pre-adjustment to be
[Activated], and then set the pre-adjustment item to be [ON]. For example, for the 50 bar
Pressure position of Item 50, if the reading on the pressure meter is 45 bar, the parameter of
this item should be increased until the pressuremeter reading reaches 50 bar. Make adjustments
On all parameters which need adjusting and make the0-160 bar pressures being set correspond
to the pressures being shown on the oil pressure meter respectively.After the adjustments are
completed, the computer executes automatically linear processing and takes the processing
results as the subsequent normal D/A proportional output values.
Initial data:
First, pre-adjust the needed maximum pressure data in 160bar, and then move the cursor to
[initial data], press the enter key and select [ON], the system will automatically distribute
average data to 10bar---160bar.

R
PORCHESON
61
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

5. Flow Pre-Adjustment Page


储 料
Entering Engineer Setting Page, press Key FEEDING twice to enter the Flow Pre-Adjustment
Page.The following is displayed:
Next Flux Pre-adjustment Return Engineer

minimum current Pre-adjust Disable 70 25200 OFF


1000
1 1 OFF 80 28800 OFF
Pressure pre-adjust
10 3600 OFF 90 32400 OFF
80.0 bar
initial data 20 7200 OFF 99 36000 OFF
OFF 30 10800 OFF
Initial data 40 14400 OFF
OFF 50 18000 OFF
pre-adjustment feeding 60 21600 OFF
OFF

Hint:0.OFF 1.ON
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Description on setting parameters

The flow pre-adjustment is the linear adjustment of flow output. In general, the standard value
is 0- 800mAand the output impedance is 40Ω,unless the manufacturer has specific requirements
since different manufactures' overall oil piping designs and the capabilities of the pressure
proportional valve being used are different.
Flow Adjustment Method:
The parameters on this page have been set before ex-factory. If the capability of the proportional
valves being used by the user is different, and the normal proportion and linear proportion
cannot be achieved, the parameters on this page can be adjusted. As for the speed adjustment,
different manufacturershave different measuring methods. Some manufacturers use the melt
tachometer to measure the rotation speed. First heat the barrel until the barrel temperature
reaches normal melt temperature. Set the melt speed to be 1, 10, 20, 30, and more until 99 and
check the actual values. Make adjustments on all parameters whichneed adjusting and make
the 0-99% speeds being set correspond to the proportional coefficients being shown on the
tachometer respectively. After the adjustments are completed, the computer executes
automatically linear processing and takes the processing results as the subsequent normal D/A
proportional outputvalues.
Initial data:
First, pre-adjust the needed maximum flow data in 99%, and then move the cursor to [initial
data], press the enter key and select [ON], the system will automatically distribute average data
to 10%---90%.

R
PORCHESON
62
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

6. Back Pressure Pre-Adjustment Page


储 料
Entering Engineer Setting Page, press Key FEEDING third to enter the Back Pressure Pre-Adjustment
Page. The following is displayed:
Next Back pressure Pre-adjustment Return Engineer

coil resistance Pre-adjust Disable 80 23993 OFF


12
1000 Ω 1 1 OFF 90 26992 OFF
minimum current 10 3000 OFF 100 29991 OFF
80.0 20 5999 OFF 110 31199 OFF
Maximum current 30 8998 OFF 120 33128 OFF
OFF 40 11997 OFF 130 39997 OFF
initial data 50 14996 OFF 140 44996 OFF
OFF 60 17995 OFF 150 47995 OFF
70 20994 OFF 160 48000 OFF

Hint:set range:0~65535
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Description on setting parameters

The back pressure pre-adjustment is the linear adjustment of back pressure output. In general,
the standard pressure is 0-800mA and the standard output impedance is 10-20Ω,unless the
Manufacturer has specific requirements since different manufactures' overall oil piping designs
and the capabilities of the pressure proportional valve being used are different
.Back Pressure Adjustment Method:
The parameters on this page have been set before ex-factory. If the capability of the proportional
valves being used by the user is different, and the normal proportion and linear proportion
cannot beachieved, the parameters on this page can be adjusted. First heat the barrel until the
barrel temperaturereaches normal melt temperature. Set the melt back pressure to be 1, 10, 20,
30, and more until 160 and check the actual values. Make adjustments on all parameters which
need adjusting and make the 0-160bar back pressures being set correspond to the back pressures
being shown on the back pressure meter respectively. After the adjustments are completed, the
computer executes automatically linear processing and takes the processing results as the
subsequent normal D/A proportional output values.
Initial data:
First, pre-adjust the needed maximum pressure data in 160bar, and then move the cursor to
[initial data], press the enter key and select [ON], the system will automatically distribute
average data to 10bar---160bar.

R
PORCHESON
63
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

7. Electronic Ruler.Pressure text Setting Page


座台/调模
Entering Engineer Setting Page, press Key NOZZ/ADJ. onec/twice enter the Electronic Ruler/
Pressure Setting Page. The following is displayed:
Next Electronic ruler 1 Return Engineer Next pressure test setup Return Engineer

Ruler Function measure value Total limit position set zero


AD1/2 Moveable Enable 593.9 600.00 600.00 OFF Ruler Function value Maximum up limit set zero 0 12V 24V

Mold close Enable ***** ***** ***** OFF


AD3/4 Screw Enable 235.75 600.00 600.00 OFF
0 12V 24V
AD5/6 Ejector Disable ***** ***** ***** OFF Screw Disable 235.75 300.00 200.00 OFF
AD7/8 Nozzle Disable ***** ***** ***** OFF
0 2.5V 0 2.5V

AD1/2 AD3/4
0 2.5V 0 2.5V

AD5/6 AD7/8
Hint:0.disable 1.enable Hint:0.OFF 1.ON
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Next Electronic ruler 2 Return Engineer Next Electronic ruler 3 Return Engineer

Ruler Function measure value Total limit position set zero Ruler Function measure value Total limit position set zero
AD1 Moveable Enable 593.9 600.00 600.00 OFF A1/B1 Moveable Enable 593.9 600.00 600.00 OFF
AD3 Screw Enable 235.75 600.00 600.00 OFF A2/B2 Screw Enable 235.75 600.00 600.00 OFF
AD5 Ejector Disable ***** ***** ***** OFF A3/B3 Ejector Disable ***** ***** ***** OFF
AD7 Nozzle Disable ***** ***** ***** OFF A4/B4 Nozzle Disable ***** ***** ***** OFF
0 2.5V 0 2.5V 0 2.5V 0 2.5V

Ad1 Ad2 A1/B1 A2/B2


0 2.5V 0 2.5V 0 2.5V 0 2.5V

Ad3 Ad4 A3/B3 A4/B4

Hint:0.disable 1.enable Hint:0.disable 1.enable


Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Description on setting parameters

(1) Electronic Ruler Function: If the equipment needs to use the electronic ruler, choose [Enable]. If
the equipment adopts stroke switch control, choose [Disable].
(2) Measurement Values: indicating the actual dynamic positions of the electronic rulers for the
moving mould, the screw and the ejector.
(3) Total Length: referring to the actual lengths of the electronic rulers for the moving mould, the
screw and the ejector.
(4) Limit Position: It refers to the maximum value set for the position. This parameter is subject to
the maximum position setting. For example , if the parameter set is bigger than the limit position
value, the system will not accept the parameter set and will retain the original setting.
(5) Zeroing: When the equipment choose [Enable] for the Electronic Ruler Function and uses the
Electronic ruler, it may appear that the mechanic movement stroke is in place and yet the actual
positions of the electronic rulers for the clamping unit, the injection unit and the ejector do not
Indicate "0". In such case, the corresponding ruler should be zeroed. Move the cursor to the
Zeroing button for [movable mold ruler], [ screw ruler] and [ejector ruler], and then
press 输ENTER入 Key to make zero clearing for the corresponding electronic ruler.
(6) Sensor function﹑maglev ruler﹑double-ruler setup:setup method same as electronic ruler。
Special instruction:maglev ruler (unit:m/s)is one signal of transmission speed in waveguide
tube,each pieces of maglev ruler’s transmission speed is different,please fill with correct data
from the magleve ruler‘s sticker so not to affect its accuracy. Attention:strongly recommends
double-channel of ruler(refer to appendix)

R
PORCHESON
64
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

8. Special Function Options Page


托模/中子
Entering Engineer Setting Page, press EJE/CORE Key to enter the Special Function 1 Options Page.
The following is displayed:
Next Chose special function 1 Return Engineer

motor idle auto stop Disable mold open stop ran ge 5.0
motor idle time limit 1 M Core start method travel
motor Y-△conversi on Disable Ejector end method Timel
motor Y-△conversion time 2.0 Mold adjust drive Hydraulic
motor △forw ard delay 0.1 Blow begin travel
Motor start delay 3.0 Heater limit Disable
Manual Nozzle advance limit Disable Feed single ring teeth number
1
Feed with mold open Disable High Temperature alarm Disable
Feed with key lock Disable injector Protective cover Enabl e

Hint:0.disale 1.enable
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Descriptions on setting parameters function mode

(1) Mot or Idle Running & Automatic Stop: When [Enable] is chosen, time setting is effective and the setting range
is2-99minutes. If the equipment has no operation within the set time period after the motor starts up, the motor
is turned off automatically to protect the motor life and to save electricity charge.
(2) Motor Y- Conversion: If [Enable] is chosen, the system converts from star output to delta output when
the motor starts up. The conversion time period can be set and the setting range is 2.0-99.9seconds.
(3) Motor Startup Delay: After the motor starts, no manual/auto operation can be conducted until the set
time is delayed.
(4) Manual Base Advance Limit: If deactivated, the injection base advance is not subject to stroke control.
If activated, the injection base advance position is subject to the control of the limit switch X06.
(5) Mould Opening with Melt: If activated, the mould opening can be done as soon as the cooling time expires,
even if the melt has not finished taking out.
(6) Melt Key Locking: If activated, press the melt key once and then the melting continues and will stop when
the melt position is reached or the time expires. Or press the melt key once more to stop the melting.
(7). Neutron beginning methods: select [travel] or [position], select [position] to set the position value, and the
Movements when the dynamic mode arrives; select [travel], select the starting movements from the four
options of dynamic mode trip.
(8). The Core start method: select [position] or [travel], start the blowing work at the dynamic mode position
or the trip conditions in automatic state.
(9) Ejector Stop Type: [Stroke] or [Time] can be chosen. If [Stroke] is chosen, the stop is subject to the stroke.
If [Time] is chosen, the stop is subject to the set time.

R
PORCHESON
65
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

(10) Mould Adjustment Activation: [Hydraulic] or [Electric] can be chosen. When [Hydraulic] is chosen,
mould adjustment pressure and speed do not participate in the mould adjustment job.
(11) Begin Blowing: Choose [Location] or [Travel], then the machine will blow in the mold moving
location or travel conditions in automatic mode.
(12) Electric Heating Restrict: Choose [Disable] or [Enable], in [Enable], the electric heating will
not be started in the process of motor start, but will in [Disable].
(13) Stock Single Ring Gear No.: The number of the gears around the screw.
(14) High Temperature Alarm Function: Choose [Disable] or [Enable], when in [Enable] and the actual
temperature is beyond the upper limit; ? in the automatic state, alarm [High Temperature]
and ejection, stock and withdrawal will not act; ? in manual state, ejection, stock and withdrawal
will continue working. In [Disable], all actions will not be affected by temperature upper limit.
(15) Ejection Protective Boot Fun ction: Choo se [Disable] or [Ena ble], when in [Ena ble] and the ejection,
stock and withdrawal act and X02 is OFF, the system will alarm with [Ejection Protective Boot
not Closed] and there is no action output; on the contrary, the action will not be affected by Xo2
state.
托模/中子
Entering Engineer Setting Page, press EJE/CORE Key twice to enter the Special Function 2 Options
Page.The following is displayed:
Next Chose special function2(upper limit) Return Engineer

mold clamping pressure 30.0 Nozzle pressure 160.0 injection pressure 160.0
mold clam ping flow 20.0 Nozzle flux 99.0 Injection flux 99.0
mold opening pressure 160.0 Mold adjust pressure 160.0 Feed pressure 160.0
mold opening flow 99.0 Mold adjust flux 99.0 Feed flux 99.0
mold clamping high pressure 160.0 Eject or pressure 160.0 Back pressure 160.0
mold clamping high pressure flow 99.0 Eject or fl ux 99.0 Temperature upper limit 600.0
open/close mold pressure 30.0 core pressure 160.0 Temperature Percent 100.0
open/close mold flow 20.0 Core flux 99.0 Standby ****

Hint:set range:0.0~160.0
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Function parameter setting introduction

(1) Pressure/flux upper limit: the setting value in this page will lie on the upper limit range for
setting values of mold parameter in every page.
(2). Maximum temperature / percentage: the scope of maximum temperature setup value.

R
PORCHESON
66
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

托模/中子
EJE/CORE
Entering Engineer Setting Page, press Key third time to enter the Special Function 3
Options Page.The following is displayed:

Next Chose special function 3 Return Engineer

first mold lubrication function Disable base forward valve of manual injection Disable
lubricate intermittent Enabl e servo function Enabl e
Lubricate mold number upper limit 200 ejector finish in sensor mode Times
Lubricate timing lower limit 3.0 electric heat auto off once temp exceeds limit Enabl e
oil lack output lim it Disable Injection failure switching to manual automatically Disable
oil lack delay alarm 2.0 nitrogen function Disable
Cool water Disable nitroge n recharing delay 0
Cool water delay 1.0 lubricat again function Enabl e
safe door contro l mode Mode 1
rear safe door close motor motor stop
Hint:0.disale 1.enable
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Function parameter setting introduction

(1) First mold lubrication: select [Enable], lubricate once when the motor is from close to open and
first molding. or it will not lubricate.
(2) Interval lubrication: can select [Enable] or [Disable] , it will lubricate no intervals when select
[Disable], it will lubricate intervals when select[Enable]
(3) Maximum lubricating mold number: The maximum number of lubricating mold ,it is used to
control lubricating cycle
(4) Minimum lubricating time :The minimum time of lubricating
(5) lack of oil delay alarm: select [Enable] it will alarm when the input time in the lack of oil delay
alarm X32 is up
(6) Water cooling: select [Enable], the cooling water switch is ON in normal state, and it will alarm "
the switch of cooling water is not open "until setting time is up
(7) safety door control mode: can select [mode 1] or [mode 2] , select [mode 1] front safety door :
X00,X01, back safety door :X15,X16(back safety door control motor), select [mode 2] front
safety door : X0, back safety door :X15 (please refer to safety door diagram I ,II)
(8) Back Safety Door Open: Choose [Stop Motor] or [Disable]. If the [Safety Door Control Mode]
chooses [Mode 1], the [Back Safety Door] function will be valid. When [Stop Motor] is chosen,
if the rear safety door X15 or X16 is OFF, the system will alarm with [Rear Safety Door Not
Closed] and the motor will stop; on the contrary, only alarm without stopping the motor.
(9) Base forward valve of Manual injection :there are [Enable] or [Disable] can be selected,when select manual
state is [Enable],signal of base forward-stop is on,Y1 is outputted and there is injection movement,
conversely no output.
(10) Servo function: there are [Enable] or [Disable] can be selected,the relevance pages will be displayed
when selecting [Enable],conversely no display.

R
PORCHESON
67
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

(11) Electric hea ting off whenT emper ature exce eds uppper limit:ther e are 【enabl e】and 【disabl e】
available.Under enable status,when the actual detection temperature is above its upper
limit,turn off heating function and alarms:temp detection exceeds set upper limit,otherwise
no need to do it.
(12) Ejector finsished under sensor status:thre are 【sensor detection finished】and 【times
of ejector reached】available.When under sensor auto mode and when choosing【sernsor
detection finished】times of ejector not reached but sensor detection okay,system will go
to next cycle by ejector finished;and when choosing【times of ejector reached】namely even
sensor detectin okay,it have to wait for times of ejector finshed and then go to next cycle.
(13) Nitrogen function:there are 【enable】and 【disable】available.When choosing 【enable】,
turn on motor and motor delayed time reached----nitrogen charing delay?---time---time is
up--proceed to charing/releasing nitrogen.
(14) Injection failure switching to manual mode:there are 【enable】and 【disable】available。
When choosing 【enable】 ,under auto mode,if injection failure alarms and switch to
manual mode;otherwise only alarms no switching to manual mode.
(15) Relubricating function:there are [enable]and [disable] availale.When choosing [enable],
while lubricating failure alarms ( malfunction elimination ) please lubricate again,it stops
alarming when detection signal from relubricating movement.

托模/中子
Entering into engineer page and then press EJE/CORE 4 times for specialfunction page 4 which will
be as following:

Next Chose special function 4 Return Engineer

auto door functio n Disable manual key lock automatically Disable


safe door drives Hydraulic open-door position Front
door open automatically dealy 0.00 s
open -door stop mode Time
door open automatically 0.00 s
safe door open pressure 160. 0 bar
safe door open flo w rate 99. 0 %
safe door close pressure 160. 0 bar
safe door close flo w rate 99 %

Hint:0.disale 1.enable
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

(1) Aut o safe door function:there are 【enbale】and 【disable】available. When choosing 【enable】,
the open or close action is being done by actuator,conversely,need manual.
(2) Safe door drives:there are [hydraulic] and [motor-driven] available,when choosing [motor-driven]
to adjust pressure,speed not participate in the door open/close movement;conversely working.

R
PORCHESON
68
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

(3) Door-opening stop mode:there are 【time】and 【distance】available,when choosing【time】,


one of the time or distance to open-stop completed and then safe door open movement;when
choosing【distance】,use distance to finish and safe door open movement
(4) Safe door key lock automatically:there are 【enbale】and 【disable】available,when choosing
【enable】inching keys of open door or close door for door opening or door closing,and press
again for movement sotp;otherwise press for movment and release for movement stop.
(5) Door open starting position:there are 【pre-mold opening】【mold open stop】and 【ejector
Finisheed】available.When choosing 【pre-mold opening】under semi-atuo mdoe and mold
open movement,s door open,same to others.
(6) Door open start delay:time begin to count before safe door runs,and when time is up then
proced to door open.
9. Servo Driver monitor Setup Page
监 视

Press MONITOR key to enter the servo driver setup page with the display as follows:
2012-02-09 Servo Driver Monitoring Parameters 12:02:09

Servo Driver NO AG2011RA


Operation Status Normal
servo connection status servo driver is off line
Driver Temperature 35.6 ℃ Motor Temperature 36.1 ℃

Pressure Setup 140.0 Bar Output Current 2.5 A


Pressure Feedback 20.0 Bar Output Torque 7 Nm
Flow Setup 99.9 % Motor rated Speed 140 Rpm
Flow Output 30.0 % power output 300 Kw

Hint:0.disale 1.enable
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

R
PORCHESON
69
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

10. Servo Driver Setting Page

托模/中子
Enter the engineer page, press EJE/CORE key to enter the setup page with the display as follows:

Next On-Line Parameters Return Engineer

on- line mode selection On-line Operation Hint Ready

No. of pump while on-line machine 2 mini speed of sub-machine 1


displacement of main machine pump 5 mL/r displacement of sub-machine pump 5 1 mL/r
displacement of sub-machine pump 1 1 mL/r displacement of sub-machine pump 6 1 mL/r
displacement of sub-machine pump 2 1 mL/r displacement of sub-machine pump 7 1 mL/r
displacement of sub-machine pump 3 1 mL/r displacement of sub-machine pump 8 1 mL/r
displacement of sub-machine pump 4 1 mL/r displacement of sub-machine pump 9 1 mL/r

Hint:0CAN 1.0~10V
F1 Delay F2 Slope

Next Selection V-Type Selection Parameters Return Engineer

Base Pressure 2.0 System Response Proportion 75


Base Flow 2.0 System Response Integral 5
Pressure Adjustment Slope 30 System Response Differential 90
Flow Adjustment Slope 30 System Response Time 10
Torque Overload Multiple 50 Pressure Discharge Reverse Speed Limit 5.0
Pump Swash Plate Switching Value 100 Reverse Max. Torque 10

Hint:set range:0.0~20.0
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

R
PORCHESON
70
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

Next multi- group PID selection Return Engineer

Mold closing slowly/fastly 0 storing 1 0


low pressure mold closing 0 storing 2 0
high pressure mold closing 0 injection retreat 0
Mold opening slowly 0 ejector forward 0
level 1 injectio n 0 ejector return 0
level 2 injection 0 Core 0
pressure maintaining 0 mold adjustment 0

Hint:set range:0.0~20.0
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

时 间
TIME
Press key to enter into diagnose then Press key enter the Servo alarm record,now the
menu is as follows:
2016-07-17 Servo alarm record 14:30:52

record data 0 display initial sequence NO 1 Page up Page down record clear

sequnce no Alarm time NO Alarm sequnce no NO Current Speed


10:16 1 15.16 1

Hint:setup :0~100
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Note: The above is the page of the related parameters of the servo driver. Please refer to [User
Manual of Servo Driver] for details.

R
PORCHESON
71
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

11. Standby Function Setting Page


时 间
After entering the correct password, press TIME
Key to enter the Standby Function Setting
Page. The following is displayed:

Next Standby Function Return Engineer

Y 6 Y 26 ON
Y 0 Y 0 OFF
Y 0 Y 0 OFF
Y 0 Y 0 OFF

X 25 X 0 ON
X 5 X 10 ON
X 0 X 0 OFF
X 0 X 0 OFF

Hint:0.OFF 1.ON
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Descriptions on setting parameters function mode

(1) Output Point Transfer Function: This function can be enable or disable. If enable , the o utput
point executes immediately transfer operation. In case that mal-function or damage occurs
to a certain point, the control can be transferred to another point by activating this function.
For example, in case that failure occurs to the mould opening output point and the knockout
core function is disable, the Y06 mould opening point can be transferred to Y26 and then the
output wires should be exchanged. The system is equipped with the function of simultaneously
transferring two output points. Once this function is enable, the system makes judgment on the
two selected items. If the item is [ON], the transfer of the pre-set conditions of the item will
be executed.
(2) Input Point Transfer Function: This function can be enable or disable . If enable, the input point
Executes immediately transfer operation. In case that mal-function or damage occurs to a certain
point, the control can be transferred to another point by activating this function. For example, in
case that failure occurs to the front safety door input point and the knockout core function is
disable, the X00 front safety door input point can be transferred to X25 and then the input wires
should be exchanged. The system is equipped with the function of simultaneously transferring
two input points.once this function is enab le, the system makes judgment on the two selected
items. If the item is[ON], the transfer of the pre-set conditions of the item will be executed.

R
PORCHESON
72
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

12. Programmable Standby Function Page


时 间
After entering the correct password, press TIME
Key to enter the Programmable Page. The
following is displayed:

Next Programmable Standby Function Return Engineer

Enabl e Y 4 AT CD Segment out


Enabl e Y 6 AT FH Segment out
Disable Y 0 AT Segment out
Disable Y 0 AT Segment out
Disable Y 0 AT Segment out

A=fast mold close B=low pressure C=high pressure D=mold close stop
E=nozzle adv anc e F=inject ion adv ance G=hold pressure H=feed
I=inj ecti on ret urn J=nozzle ret urn K=mold open slow L=fast mold open
M=low mold open N=ejector O=core P=mold adject e

Hint:set range :0~77


Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Descriptions on setting parameters function mode

In order to meet diversified application needs and provide an innovative product, we take the
Initiative to offer the programmable standby function page so that the users can define and
revise by themselves the functions and the action sequence.
Example 1: For a certain mould injection machine, due to the different design of the oil piping,
it is required that a point is output while clamping at high pressure and the power will not be
interrupted until the melt finishes taking out. To achieve such a special function, choose an item
and have it activated,and then specify an output point (i.e. this function is output through Y 01),
and then set the action sequence [CD].
Notes: Regarding the output scope of Sequence D Clamping Stop, in automatic mode, the
Clamping switch is contacted during the process of mould close at high pressure, and this
sequence output starts until the melting finishes; in manual mode, the clamping switch is contacted
during the process of mould close at high pressure, and this sequence output starts until the mould
opening key or the reset key is pressed.
Example 2: For a certain mould injection machine, due to the different design of the oil piping,
it is required that a point is output while injecting and melting. To achieve such a special function,
Choose an item and have it activated, and then specify an output point (i.e. this function is
output through Y22),and then set the action sequence [FH].

R
PORCHESON
73
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

13. Temperature ParameterSetting Page


温 度
After entering the correct password, press Key TEMP.
to enter the Temperature Parameter
Setting Page. The following is displayed:

Next temp contr ol param eter Return Engineer


Function P D Function P D
Ejector Enabl e 100 200 EK0 Enable 0 0
EK1 Enable 0 0
1 Segment Enabl e 100 200 EK2 Enable 0 0
2 Segment Enabl e 100 200 EK3 Enable 0 0
EK4 Enable 0 0
3 Segment Enabl e 100 200 EK5 Enable 0 0
4 Segment disable 100 200 EK6 Enable 0 0
EK7 Enable 0 0
5 Segment Disabl e 100 200 EK8 Enable 0 0
K 6 Oil Temperature Alarm Disabl e EK9 Enable 0 0
EK10 Enable 0 0
Oil Temperature upper limit 60. 0 EK11 Enable 0 0

Hint:set range :0~300


Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

function Description on setting parameters

(1) Ejector Fun ction、1Se gment 、2Se gment 、3Se gment 、4Se gment 、5Se gment function、[Activated]or
[Deactivated] can be chosen. If deactivated, the system will not execute inspectionand control on
this sequence.
(2) Oil Temperature Alarm: [Activated] or [Deactivated] can be chosen. If deactivated, once it is detected
(3) Pd Setting: Pd has been set before ex-factory. It is recommended that the user should not revise this
parameter under normal circumstance.
(4) Proportion control: proportion control is one of the simplest way for controlling, in which the input
error signals are in proportion relation with output signals. There are steady-state errors when
proportion control is the only way to be utilized.
(5) Different coefficient control: in different coefficient control, output error signals of controller form
direct proportion relationship with input error signals of controller Fluctuation even destabilization
may appear in automatic control system during the course of getting over and adjusting errors. The
reason is: the existing heavier inert (links) or lagging assemblies can constrain errors, and its changing
is always behind the changing of errors.The solution is to make the changing of errors constraint effect
become advancing, i.e., the errors constraint effect should be zero when errors become close to zero.
That is, it is not efficient enough to introduce proportion into controller merely. The function of
Proportion can only enlarge the amplitude value of errors. But at present time it is necessary toin
crease different coefficient , which can forecast the changing directions of the errors. Thecontroller
combined proportion with different coefficient can cause errors constraint effect to be zero, even
to be negative,thereby severe over adjusting of proportion under controlling can be avoided. So for
Assemblies under controlling with heavier inertia or lagging, PD controller can improve dynamic
behaviors of system during adjustment.

R
PORCHESON
74
User's Manual for MK3XX V1.0 Chapter 5 Instructions for the System Commissioning Settings

14. Machine No./Ex-Factory Value/Time Setting Page


资 料
After entering the correct password, press Key DATUM
to enter the Machine No./Ex-Factory Value/
Time Setting Page. The following is displayed:

Machine No./Ex-Factory Value Return Engineer

Machine No Input conversion ABC enter


M3 timer to zero Confirm
Controller No System Backup value Confirm
PS860A M/MK310
Ex-Factory Value Restoration Confirm
Soft ware version
V2.2 Password management enter
Super password

TUE 2016-04-25 15:30:40

Hint:1-12
Delay Slope Pre-adj. Ruler. Funtion. I/O transfer temp control factory setup

Descriptions on setting parameters function mold

(1) Machine No: The system is equipped with the function of setting NO.for the mould injection
machine so that the manufacturer can set the No. for easy sales management and after-sales
service record.
(2) Ex-Factory Value Restoration: During the modifying process of password pages, if normal
operation cannot be achieved due to too much deviations of the modified parameters, press
Key Enter and choose Confirm, and then all the contents and all the parameters will be restored
to the standards values set before ex-factory.
(3) System Backup value:standard values backup are provided for resetting when machines leave
factory;
(4).Time setup: to set up the time, after the setup, press the [input] key, and then press [OK], the
update is successfully set up.

R
PORCHESON
75
User's Manual for MK3XX V1.0 Chapter 6 Input/Output Mode Inspection

Chapter 6 Input/Output Mode Inspection


1. Alarm history page
诊 断

Press DIAGNOSE key , to enter the alarm history page, and it is as follows:
2016-05-17 Alarm history 14:30:52

record item number 2 Display start number 20 page up page down record clear

sequence no Alarm Time Number Alarmmatter


16 10:06 16 10:06 64 Temperature highter
16 10.13 16 10.13 21 cycle time over

Alarm Input Output Key test AD test Servo alarm

Description on setting parameters

(1). Display: the system stores at most 999 pieces of alarm records for inspection, it will be helpful
for the maintenance of the equipments.
(2). View method:a:move cursor to the up and down button to view,b,[initial sequence
no display] :to locate by initial sequence no.and then use the up and down key to view.

R
PORCHESON
76
User's Manual for MK3XX V1.0 Chapter 6 Input/Output Mode Inspection

2. Input Inspection Page

(1) Press 2 VWX Key on the Main Page to enter Input Inspection Page 1 and the following will
be displayed:
2016-05-28 Input check 1 16:33:30

X00 front door 1 X10 lubricating oil is low


X01 front door 2 X11 lubricating press is low
X02 injector Protective cover X12 safe valve detection
X03 mold close stop X13 Ejection before stop *
X04 Electric Eye enter X14 Ejection return stop
*
X05 feed rotation speed X15 back door1
X06 before nozzle stop X16 back door 2
*
X07 after nozzle stop X17 safe door realy
*
Machine run well mold close slow
Alarm Input Output Key test AD test Servo alarm

(2) Press 3 YZ Key on the Main Page to enter Input Inspection Page 2 and the following will
be displayed:

2016-05-28 Input check 2 16:33:30

X20 fine adjust teeth number X30 core A advance /Count


X21 front mold adject stop X31 core A return
X22 back mold adject stop X32 core B advance /Count
X23 mechanic hand mold close X33 core B return
X24 mechanic hand ejector X34 core C advance /Count
X25 mold area X35 core C return
X26 door open stop X36 core D advance /Count
X27 motor fault X37 core D return
X40 nitrogen uppper limit X42 Cooling water
X41 nitrogen down limit

Machine run well mold close slow


Alarm Input Output Key test AD test Servo alarm

R
PORCHESON
77
User's Manual for MK3XX V1.0 Chapter 6 Input/Output Mode Inspection

3. Key Inspection Page

(1) Press 4 JKL Key on the Main Page to enter Key Inspection Page I and the following
will bedisplayed:

2016-05-28 Key check 1 16:33:30

M00 manual M08 charge


M01 Semi-automatic M09 auto purge
M02 Electric Eye auto M10 mold chose
M03 time auto M11 injection manual
M04 heater on/off M12 injection suck back
M05 motor on/off M13 blow male manual
M06 open mold manual M14 blow female manual
M07 close mold manual M15 mold thick manual

Machine run well mold close slow


Alarm Input Output Key test AD test Servo alarm

(2) Press 5 MNO Key on the Main Page to enter Key Inspection Page 2 and the following will
be displayed:

2016-04-28 Key check 2 16:33:30

M16 mold thin manual M24 ejector manual


M17 ejector return manual M25 core C in manual
M18 ejector advance manual M26 core C out manual
M19 lubricate manual M27 core B in manual
M20 ejector manual M28 core B out manual
M21 core A in manual M29 data lock
M22 core A out manual M30 emergency stop
M23 lubricate manual M31

Machine run well mold close slow


Alarm Input Output Key test AD test Servo alarm

R
PORCHESON
78
User's Manual for MK3XX V1.0 Chapter 6 Input/Output Mode Inspection

(3) Press 6 PQR Key on the Main Page enter A/Dcheck and the following will be displayed:

2016-05-18 A/D check 16:33:30

K0 eject temperture
K1 1Segment temperture
K2 2Segment temperture
K3 3Segment temperture
K4 4Segment temperture
K5 5Segment temperture
K6 oil 1 temperture

Machine run well mold close slow


Alarm Input Output Key test AD test Servo alarm

4. Output Inspection Page

(1) Press 7 ABC Key on the Main Page to enter Output Inspection Page 1 and the following will
be displayed:

2016-05-18 Output check 1 16:33:30

Y00 mold close Y10 ejector return


Y01 nozzle advance Y11 mold thin
Y02 injector Y12 different ial mold locki ng
Y03 feed Y13 mold thick
Y04 suck back Y14 mold open buff er
Y05 nozzle return Y15 fault alarm
Y06 mold open Y16 low pressure mold close
Y07 ejector advance Y17 high pressure mold close

Machine run well mold close slow


Alarm Input Output Key test AD test Servo alarm

R
PORCHESON
79
User's Manual for MK3XX V1.0 Chapter 6 Input/Output Mode Inspection

(2) Press 8 DEF Key on the Main Page to enter Output Inspection Page 2 and the following
will be displayed:
2016-05-28 Output check 2 16:33:30
Y20 mold open finished Y30 core A out
Y21 ejector finished Y31 core B in
Y22 fully auto Y32 core B out
Y23 nitrogen recharge Y33 core C in
Y24 nitrogen release Y34 core C out
Y25 blow male Y35 core D in
Y26 blow female Y36 core D out
Y27 core A in Y37 big pump
Y40 door open Y42 middle pump
Y41 door close
Machine run well mold close slow
Alarm Input Output Key test AD test Servo alarm

(3) Press 9 GHI Key on the Main Page to enter Output Inspection Page 3 and the following
will be displayed:
2016-05-28 Output check 3 16:33:30

T0 ejector temperture Manual indicate


T1 1Segment temperture Semi-automatic
T2 2Segment temperture Electric Eye auto
T3 3Segment temperture time auto
T4 4Segment temperture Heater ON/OFF
T5 5Segment temperture Motor ON
Oil lubricate Auto run
S11△ motor S12 Y Motor

Machine run well mold close slow


Alarm Input Output Key test AD test Servo alarm
(6) Above delivery inspection pages are used for monitoring signals. If you want to inspect whether
the delivery valve is ok or not manually without any actions, you can move the cursor to the
delivery name which is waiting for your inspection, pressure enter button,then the delivery valve
will come to work. Meanwhile the solid block in the scene shows the delivery of the signals.

Special explaination

All the input and output point pages in this instruction manual are subject to changes without
notice. The inspection pages displayed on the computer should be correct and final.

R
PORCHESON
80
User's Manual for MK3XX V1.0 Reference & Appendices

Appendix 1:MK310 keyboard installation dimension Layout

210.00

194.00

14.00
180.50
8.00
227.00

394.50

470.00
227.00

19.50
8.00

47.00

R
PORCHESON
81
User's Manual for MK3XX V1.0 Reference & Appendices

Appendix 2:MK320/330 keyboard installation dimension Layout

260.00

244.50
212.00

14.00
7.50
227.50

388.00

470.00
227.50

24.00
7.50

46.65

R
PORCHESON
82
User's Manual for MK3XX V1.0 Reference & Appendices

Appendix 3:Mk360 keyboard installation dimension Layout

35
9 1 6. 8

180

422

162

6-M4X12 screw

R
PORCHESON
83
User's Manual for MK3XX V1.0 Reference & Appendices

Appendix 4:External dimensions for power supply case and transformer


215
150

4,4
114,8
135,5

POWER PACK

220,00
151,00 46,50

PS660AM
MC600AM
170,00
180,00
190,00

7,50
15,00

300.00

34.50 231.00 34.50 47.50

PS860AM
MC800AM
190.00

210.00

8.00
5.00

15.00

Exterior dimensions and installation hole position drawings for main controller
R
PORCHESON
84
Orange Back Yellow Gray
RS232
AC180-260V

0V
GND

CGND
485B
485A

+10V
CAH
CAL
24VG
+24V

+10V
+24V
+24V
24VG
+24V
24VG
+ 5 V(3 A) N L
+ 2 4 V(3 A)
+ 2 4 V(8 A)
RUN + 3 8 V(3 A)

2010-03-28 *Manual* 20:38:08


Nozzle 1Segment 2Segment 3Segment 4Segment 5Segment oil temperature Mold number: 2512
+ +24V - Pressure Proportional Valve
X00 front door 1 pressure P
34.2 34.3 34.1 34.1 34.1 34.3 **** G-18CUP 0
Setup: 50.00 S Operate: 2.14 S Cycle: 216.90 S
X01 front door 2 +
1 - Speed Proportional Valve
Pressure: 20.0 Bar Flux: 20.0 % back pressure: 0.0 Bar X02 injection Protective cover Speed S
Temperture.OK 2 + Back pressure Proportional Valve
X03 mold close stop
3 Back pressure F -
4 X04 Electric Eye enter Standby Y 3 3 3
33 66
5 X05 feed rotation speed 2
0 99
7.6 %
Standby Y 3 2
33 66

0 99
7.6 %

6 X06 before nozzle stop blow female Y 3 1 1


Move mold: 593.9 MM Ejector: **** MM estimate production: 0 MM 7 X07 after nozzle stop 0
User's Manual for MK3XX V1.0

Screw: 6.15 MM Screw speed: **** RPM current production: 0 MM


blow male Y 3 0
Machine Run Well mold close slow - XCOM YCOM +
0 X10 Standby core B out Y27 7
1 X11 Standby core B in Y26 6
2 X12 Ejection return Fender core A out Y25 5
Appendix 5:MC800AM system drawing

3 X13 Ejection before stop core A in Y24 4


4 mold open buffer Y23 3
X14 Ejection return stop
5 X15 back door 1 middle pump Y22 2
6 X16 back door 2 big pump Y21 1
7 X17 motor start fault alarm Y20 0
- XCOM YCOM +
0 X20 fine adjust teeth number high pressure mold close Y17 7
1 X21 front mold adject stop low pressure mold close Y16 6
2 X22 back mold adject stop machine eject stop Y15 5
3 X23mechanic hand mold close machine mold open stop Y14 4
4 X24 mechanic hand eject mold thick Y13 3 P2 P1
5 X25 core A in /Count Poor dynamic mold close Y12 2
6 X26 core A out /Count mold thin Y11 1
7 X27 motor fault eject return Y10 0

PORCHESON
- XCOM YCOM +

R
0 X30 core B advance /Count eject advance Y07 7
1 X31 core B return /Count mold open Y06 6
nozzle return Y05 5
suck back Y04 4
feed Y03 3
2 X32 oil short inject Y02 2
+ REF+ nozzle advance Y01 1
1 AD4 mold close Y00 0
PW350

2 AD5

85
pressure test
3 AD6
- A DG 220V(L)
2 Mold close
Power pack

2 Inject
2 Eject
REF+

Electronic ruler
+ FireWire L 1 2
oil temperature - K6 oil temperature
+ M 11 M oil motor
Segment5 - K5 Segment5 Y 10 Y
+ 9
Segment4 - K4 Segment4
+ OIL 8 Lubricate motor
- T5 7 HC5 Segment5
Segment3 K3 Segment3
+ T4 6 HC4 Segment4
Segment2 - K2 Segment2 Segment3
+ T3 5 HC3
- T2 4 HC2 Segment2
Segment1 K1 Segment1
+ T1 3 HC1 Segment1
Nozzle - K0 Nozzle Nozzle
+ T0 2 HC0
Motor Electric-Heating Wiring Diagram (for reference only)

zero value N 1
220V(N)

PORCHESON
MC800AM
Reference & Appendices
User's Manual for MK3XX V1.0 Reference & Appendices

Appendix 6:MC600AM input and outputWiring Diagram

Yellow Gray

Communication power supply


E-ruler /Magnetic railling ruler Analog out

P1 Pressure Pressure Proportional Valve


core D return
core D advance /Count
F1 Speed Speed Proportional Valve
core C return
core C advance /Count Back pressure Proportional Valve
P2 Back pressure
core B return
core B advance /Count core B out
core A return core B in
core A advance /Count core A out
servo interface
motor fault core A in
door open stop blow female
mold area blow male
mechanic hand ejector nitrogen release
mechanic hand mold close nitrogen recharge
back mold adject stop fully auto
front mold adject stop ejector finished
fine adjust teeth number mold open finishe d

safe door realy high pressure mold close


back door 2 Low pressure mold close
back door1 fault alarm
Eject ion ret urn stop mold open buff er
Ejectio n befo re stop mold thick
safe valve detecti on differential mold locking
lubricating press is low mold thin
lubric atin g oil is low Ejector return

after nozzle stop ejector advance


before nozzle stop mold open
feed rotation speed nozzle return
Electric Eye enter suck back
mold close stop feed
injector Protective cover injector
front door 2 nozzle advance
front door 1 mold close
1Segment

2Segment

3Segment

4Segment
Nozzle

Oil

Motor Electric-Heating Wiring Diagram (for reference only)


R8
R9
R10
R11
R4

R6
R2
R3

R5
R1
1Segment

2Segment

3Segment

4Segment

Oil
Nozzle

1Segment
2Segment
3Segment
4Segment
5Segment
Nozzle

Lubricate

Y
M

motor

R
PORCHESON
86
User's Manual for MK3XX V1.0 Reference & Appendices

Appendix 7:MC800AM input and outputWiring Diagram

Yellow Gray
Analog out Power
E-ruler /Magnetic railling ruler pressure check

Nozzle P1 Pressure Pressure Proportional Valve

P2 Pressure Back pressure Proportional Valve

F1 Speed Speed Proportional Valve


Ejector
injector

F2 Speed Speed Proportional Valve


mold close

manipulator use

manipulator use
manipulator emergency stop servo interface Dfeects
mold closed allowable auto mode
mould area ejector forward finished
ejec tor allo wable mold opened finished
Cooling water middle position of mold opened
nitro gen uppper lim it big pump
nitrogen down limit middle pump

X37 core D return big pump


X36 core D advance /Count core D out
X35 core C return core D in
X34 core C advance /Count core C out
X33 core B return core C in
X32 core B advance /Count core B out
X31 core A return core B in
X30 core A advance /Count core A out

X27 motor fault core A in


X26 door open stop blow female
X25 mold area blow male

X24 mechanic hand ejector nitrogen release


X23 mechanic hand mold close nitrogen recharge
X22 back mold adject stop fully auto
X21 front mold adject stop ejector finished
X20 fine adjust teeth number mold open finished

X17 safe door realy high pressure mold close


X16 back door 2 Low pressure mold close
X15 back door1 fault alarm
X14 Eject ion ret urn stop mold open buff er
X13 Ejectio n befo re stop mold thick
X12 safe valve detecti on differential mold locking
X1 1 lubricating press is low mold thin
X10 lubric atin g oil is low Ejector return

X07 after nozzle stop ejector advance


X06 before nozzle stop mold open
X05 feed rotation speed nozzle return
X04 Electric Eye enter suck back
X03 mold close stop feed
X02 injector Protective cover injector
X01 front door 2 nozzle advance
X00 front door 1 mold close
1Segment

2Segment

3Segment

4Segment

5Segment

6Segment
Nozzle

1Segment
2Segment
3Segment
4Segment
5Segment
6Segment
Nozzle
Oil

R2
R3
R1

R5
R6
R7
R8
R9
R10
R11
R4
1Segment

2Segment

3Segment

4Segment

5Segment

6Segment

Oil
Nozzle

Lubricate
1Segment
2Segment
3Segment
4Segment
5Segment
6Segment
Nozzle

Y
M

motor

R
Lubricate motor

PORCHESON
87
User's Manual for MK3XX V1.0 Reference & Appendices

Appendix 8:PS660AM input and outputWiring Diagram

+10VS
10VG
CGND
+10VP

CAL/B-
CAH/A+

+24V

24VG
24VG
GND
+24V

+24V
+24V
OIL
RS232

T1
T3
T2
T4

T0
M
Y
Analog out CAN/485 Motor Electric-Heating Wiring Diagram Orange Brown Yellow Gray

+5 V(3 A)
+ 24 V(4 A)
+ 24 V(8 A)
RUN + 38 V(2 A)

+ +2 4V
Pressure
+P + Pressure Proportional Valve
0 X 00 front door 1 -
1 X 01 front door 2
Speed
+S + Speed Proportional Valve
2 X 02 injector Protective cover -
3 X 03 mold close stop core B out Y 27 7
4 X 04 Inductive switch core B in Y26 6
5 X 05 feed rotation speed core A out Y25 5
6 X 06 nozzle adv. Stop core A in Y 24 4
7 X 07 nozzle ret. Stop mold open buffer Y23 3
- XCO M air blst.mov. Y22 2
0 X 10 fine adjust teeth number air blst.stn. Y2 1 1
1 X 11 lub rica ting oil is low fault alarm Y20 0
2 X 12 Standby Y CO M +
3 X 13 Ejector adv. Stop high pressure mold close Y 17 7
4 X 14 Ejector ret. Stop low pres sure mold clo se Y 1 6 6
5 X 15 back door machine ejector stop Y 1 5 5
6 X 16 robot mol d close machine mold open sto p Y 14 4
7 X 17 robot eject mold thick Y 1 3 3
- XCO M Differenti al mold close Y 1 2 2
0 X 20 lubricating pressure is low mold thin Y1 1 1
1 X 21 Front mold adjust stop Ejector ret. Y 1 0 0
2 X 22 Back mold adjust stop Y CO M +
3 X 23 core B in stop Ejector adv. Y 07 7
4 X 24 core B out stop mold open Y 0 6 6
5 X 25 core A in stop nozzle ret. Y 0 5 5
6 X 26 core A out stop suck back Y 04 4
7 X 27 motor fault charge Y 0 3 3
- XCO M Injector Y 0 2 2
- nozzle adv. Y0 1 1
thermocouple input

K4
4Segment + mold close Y 0 0 0
- K3
Y CO M +
3Segment + -2
Electronic ruler

ADG
- K2
Ejector
2Segment + Injector 2
- K1
mold close 2
1Segment + RE F + +

PORCHESON
PS660AM

R
PORCHESON
88
User's Manual for MK3XX V1.0 Reference & Appendices

Appendix 9:PS860AM input and outputWiring Diagram

+10VP
+10VS
10VG

24VG
24VG
CGND

GND

GND
CAH/A-

+24V
CAL/B+

+24V

+24V
+24V
RS232
Analog out CA N/ 48 5 Orange Brown Yellow Gray

+ 5 V(3 A)
+ 2 4 V(4 A)
+ 2 4 V(8 A)
RUN + 3 8 V(2 A)

+24V Pressure Proportional Valve


Pressure P
X 0 0 front door 1
X 0 1 front door 2 Speed Proportional Valve
Speed S
X 0 2 injector Protective cover Back pressure Proportional Valve
X 0 3 mold close stop Back pressure F
X 0 4 Inductive switch Standby Y33
X 0 5 feed rotation speed Standby Y32
X 0 6 Nozzle adv. Stop Female mold blow Y31
X 0 7 nozzle ret. Stop Male mold blow Y30
XCOM YCOM
X 1 0 Standby core B out Y27
X 1 1 Standby core B in Y26
X 1 2 Ejector back Fender core A out Y25
X 1 3 Ejector adv. Stop core A in Y24
X 1 4 Ejector ret. Stop mold open buffer Y23
X 1 5 back door 1 Middle pump Y22
X 1 6 back door 2 big pump Y21
X 1 7 Motor start over fault alarm Y20
XCOM YCOM
X 2 0 fine adjust teeth number high pressure mold close Y17
X 2 1 Front mold adjust stop low pressure mold close Y16
X 2 2 Back mold adjust stop machine ejector stop Y15
X 2 3 robot mold close machine mold open stop Y14
X 2 4 robot eject mold thick Y13
X 2 5 core A in stop Differential mold close Y12
X 2 6 core A out stop mold thin Y11
X 2 7 motor fault Ejector ret. Y10
XCOM YCOM
X 3 0 core B in stop Ejector adv. Y07
X 3 1 core B out stop mold open Y06
nozzle ret. Y05
suck back Y04
charge Y03
2 X 3 2 Oil short alarm Injector Y02
+ REF+ nozzle adv. Y01
Electronic ruler Pressure testing

1 AD4 mold close Y00


2 AD5
3 AD6
- ADG 220V(L)
2 Mold close
2 Inject
2 Eject
+ REF+
Fire Wire
oil temperature +
K6 oil temperature oil motor
Motor Electric-Heating Wiring Diagram (for reference only)

5Segment +
K5 5zone

4Segment +
K4 4zone Lubricate motor
5Segment
3Segment +
K3 3zone
4Segment
Danger
2Segment +
K2 2zone 3Segment
2Segment
1Segment +
K1 1zone
1Segment
Nozzle +
K0 Nozzle Nozzle
zero value
220V(N)

PORCHESON
PS860AM

PS860AM input and outputWiring Diagram


R
PORCHESON
89
3
3 80 V / 5 0 Hz POWER
MCB
R R1
S S1
T T1
N
User's Manual for MK3XX V1.0

RC Filter CB0 CB1 CB2 CB3 CB4 CB5


MC M
M Y M
O.L
M MC

PORCHESON
R
PUMP MY HC0 HC1 HC2 HC3 HC4 HC5
MOTOR

90
MC MY M H0 H1 H2 H3 H4 H5

O.L
Appendix 10:Motor Electric-Heating Wiring Diagram (for reference only)

MY

1SEGMENT 3SEGMENT 5SEGMENT


N
EJECOR 2SEGMENT 4SEGMENT
Reference & Appendices
User's Manual for MK3XX V1.0 Reference & Appendices

Appendix 11:Introduction of new type of patent double channel compensation linear sensor

Linear sensor wiring diagram seechart1

V
V1
SENSOR V2
COM

图一

OUTPUT OUTPUT

V V V1/V2
9
90% V1 10%-90%V 9 (100%,9/1)
8
7
6
5
4
3
2 (75 %,7/ 3)
(0%,1/ 9) (25 %,3/ 7)
10% V2 90%-10% 1 (5 0 %,1 )
STROKE
25 % 50 % 75 % 10 0%
STROKE

The reason for digital bounce of traditional potentiometer type of displacement sensor is actual caused by
fluctuations of supply voltage or measurement reference voltage or by these two elements.Traditional linear
scale now can not solve the digital bounce problem generated by servo systems,but the double-path compensation
type of displacement sensor is just designed for this prolem.
And when input voltage of displacement sensor is rised or falled,this v1/v2 value remain unchanged,namely
this curve is unchanged.Then this curve which not change with voltage variation(in this example,voltage rise
to 1 vdc or fall to 1vdc is still reliable) and this decides the displacement sensor's shift.Even in a situation like
voltage change causing by interference,can still reach 0.015mm stability.(take 350mm stroke as example)when
stroke reach 250mm,the stability can still reach 0.10mm.These performances are two order of magnitudes
higher than traditional displacement sensor which is first choice for precision injection molding machine.
Use the new type of displacment sensor can solve once for all the problems such as injection measurement
not correct, inaccurate of mold opening position or even cause damage to machine.As injection molding machine
manufacturer to adopt the new type of displacement sensor can greatly reduce frequences of malfunction and
maintenance so as to lower maintenance service charge and to improve brand image.
This patent displacement sensor is with analog signal, simple structure,mechanical compatibility,high
reliability,cheap cost and good adoptive to power supply,strong anti-interference to servo system.

R
PORCHESON
91
User's Manual for MK3XX V1.0 Reference & Appendices

Appendix 12:Magnetic suspension displacement sensor

Digital impulse output is the most economic


can reach effect of anti-interference digital
signal output.First controller will send start
pulse to sensor.Sensor will issue stop pulse
correspondingly based on magnetic pitch
position,And controller can calculate the time
difference between two groups pulses and
then calculate the precision displacement
value.

Installation of floating magnetic is very


simple,Compare with captive magnetic,
floating magnetic can demonstrate the
advantage of non-contact sensing and
eliminate wear of captive magnetic socket
(Working distance between magnetic and
working surface is 0.1--10mm)

R
PORCHESON
92
User's Manual for MK3XX V1.0 Reference & Appendices

开始/停止
控制模块 传感器

output
digital pulse output
(IP65 4pins connector)

mounting
1=42.5mm mounting
2=42.5mm isolation mounting
3=50mm mounting

Magnetic type
1=captive 3=die-casting
2=suspension 4=large suspension
effective stroke(mm)

Accept custom

R
PORCHESON
93
User's Manual for MK3XX V1.0 Reference & Appendices

Appendix 13:Product selection table


Mainframe selection chart
Mainframe model specification MC600AM MC800AM
Outline size 180X220 202X300
Input/output ports 32/27 39/40
Relay output ports 10 11
Temperature input 6 8
AD analog quantity input 8 8
AD analog quantity input 4 8
magnetic suspension ruler 4 4
DAC 0-1Aoutput 3+2(PWM) 4+2(PWM)
DAC 0-10Vout put 3 4
I/Oextension 8/22 8/22
Communication pattern RS232/RS485/CAN RS232/RS485/CAN
AD Sensor 0 4
Notice:E-ruler,magnetic suspension ruler use same AD input,while use it for magnetic suspension ruler,the E-ruler can
not be used,same to double-path ruler.
Keyboard selection chart

Outline size MK310 MK320 MK330 MK360


Model specification 210X470 260X470 260X470 300X510
CPU specific atio n A8/300M A8/300M A8/300M A8/800M
L C D screen 7寸 80 0X480 7寸 80 0 X 4 80 8寸 10 2 4X600 1 0寸 1 024X 6 0 0
Communication interface RS232 RS232 RS232 RS232
Working temperature -10~50℃ -10~50℃ -10~50℃ - 1 0~5 0℃
Ethern et interfac e 100M 100M 100M 100M
Storag e interfac e USB USB USB USB
Key life 200000times 200000times 200000times 200000times

R
PORCHESON
94
User's Manual for MK3XX V1.0 Reference & Appendices

Appendix 14:Product Guarantee Terms

Product Guarantee Terms


I. Our guarantee services are provided by our after-sale service center of all offices all over
China and cover all products sold by us.
II.Our products carry out one-month 3-R service and two-year (one year for LCD screen)
free repair service. Except otherwise specified by both parties, these periods shall start
as of the date where the products are sold.
III. Provided that they are used normally, in case of failures due to quality reason of the
products, within the 3-R or free repair period, we will provide free repair or replacement
for you.
IV. Within the 3-R or free repair period, in any of the following circumstances,you will not
be able to enjoy the 3-R service and free repair service:
1.When the product is defective or damaged due to human factor or force majeure;
2.When the product is damaged due to the installation and operation not conforming to
the related regulations;
3.When the product is damaged due to peripheral electric leakage or short during use;
4.When the product is damaged due to being bumped by external force during use;
5.When the product is repaired without permission or its bar code or serial number is tore
or altered;
6.When the product is used in the environment with high temperature and humidity and
thus it is burnt due to overheat or damaged due to high damp.
V. We undertake hereby that, if the domestic user needs after-sale services due to product
quality, based on our service offices everywhere, we will repair the product within 24h
if in the same city, within 48h if in the same province or not later than 72h if out of the
same province to reach your place; if the overseas user needs such service, he can send
the product back to us at its own cost and we will provide the desired repair.
VI.In order to satisfy the individualized demand of the user, our products can provide
software development package for secondary development; however, the user should
bear all risks therefrom.
VII. In case of failures during use, the user should inform us as soon as possible and then
we will display our professional technicians for repair. It is not allowed to dismantle
the product by the user without our permission; otherwise, it will be deemed that the
user waives the right for free repair and any loss or product damage will be assumed by
the user.
VIII. The repair out of the free maintenance period will be charged. The failure of the same
feature can enjoy 3-month free maintenance as of the completion of the first maintenance;
howev er, the six circumstances mentione d in IV above will be exclude d for free maintenance.
IX. These Terms shall come into effect as of June 1, 2009. In the case where any terms before
are inconsistent with these Terms, the latter shall prevail.
X. We reserve the final right to interpret these Terms.

R
PORCHESON
95

You might also like