The heat load duration curve, showing the cumulative III. RESULTS
duration for different loads in the system within a full year, can According to the part 2.B. the heat load duration curve for a
be cconstructed using the calculated hourly loads. reference city was constructed based on real data for the years
2009-2010 (Figure 1). The optimal capacity was defined. The
D.Comparing of alternatives solid line shows the heat load duration curve.
A district heating system consisting of cogeneration plant and As it can be seen from the Figure 1, the maximum heat load is
thermal energy storage has been compared with a system 7300 KW. The dash line shows the optimal capacity defining
including only cogeneration plant without any thermal energy process. The optimal capacity calculated by formula (1) is 2,58
storage. MW, which is 0,353 from the maximal heat load.
Fig. 1 Heat load duration curve and optimal cogeneration capacity defining
For simulation of district heating system operating, including The parameters used for calculations are shown in Table 1
cogeneration plant coupled with thermal storage the following As it can be seen from the Figure 2A, the heat load during
assumptions were made: winter days is always higher than the maximum cogeneration
-Losses of thermal energy storage are equal to 0.5% per hour; plant heat capacity. The heat load is covered by the heat
-Thermal energy maximum storage heat capacity is 5 MWh. produced by cogeneration and peak boiler. It means that
during winter months the thermal energy storage utilities are
TABLE 1 not used.
THE PARAMETERS OF COGENERATION PLANT AND PEAK BOILER The Figure 2B shows typical spring/autumn day, when the heat
USED FOR SIMULATION
load during the day becomes little higher or lower, than the
Cogeneration plant Peak boiler installed cogeneration plant capacity. Using the thermal energy
(gas engine) storage capacity it is possible to supply the required heat
Capacity 2,18 MWel ;2,58 MWth 5 MWth without the peak boilers. In this case the produced heat is used
Efficiency ηel=39%, ηtotal=85% 90% by heat consumers but actually later, than it has been
Fuel natural gas natural gas produced.
ISBN: 978-1-61804-022-0 73
Recent Researches in Geography, Geology, Energy, Environment and Biomedicine
A B
Fig. 2 Simulation for heat load, cogeneration plant , thermal energy storage and peak boilers
A.Winter day B. Spring/autumn day
Using equation (4) the new heat load duration curve has As it can be seen, the cogeneration plant coupled with
been constructed. The Figure 3 shows this curve (the solid thermal energy storage equipment can operate during longer
line). The dash line shows heat, produced by cogeneration. period that without it, and it can produce more heat and
electricity.
Fig. 3 Heat load duration curve taking into account thermal energy storage
The different indicators were analysed for evaluating the in comparison with separate power and heat production by
thermal energy storage use in district heating system with 22.67 %, which is by 2.51% larger than in cogeneration
cogeneration plant. The results of the evaluation are shown in without the thermal energy storage use. Despite the additional
Table 2. heat losses from the thermal energy storage unit this
According to this table, the heat and electricity amount technology makes operation of cogeneration plant more
produced by cogeneration can be increased by more than 26% effective.
by using the thermal energy storage. The thermal energy Besides, the reduction of CO2 emissions is larger by 26%
storage use provides the primary energy efficiency increasing with the thermal energy storage, than without it.
ISBN: 978-1-61804-022-0 74
Recent Researches in Geography, Geology, Energy, Environment and Biomedicine
TABLE 2
COMPARISON OF INDICATORS FOR COGENERATION WITH AND WITHOUT ACCUMULATOR TANK