TESCO

CORPORATION

Copyright 2011 Tesco Corporation


ECI Top Drives
Level I Training
Overview

Copyright 2011 Tesco Corporation


Tesco Top Drive
system

Copyright 2011 Tesco Corporation


Power Module

Copyright 2011 Tesco Corporation


Power Module
Houses all control
and distribution
power for the Tesco
Top Drive system.

Copyright 2011 Tesco Corporation


Main Components
of the Power Module
 TVSS.
 Control Panel.
 MD-500.
 System Control Module.
 PLC.
 Lab View.
 Motor starters.
 Braking resistors.
 Heat pump.
 Dehumidifier.
 Control distribution.
 Power distribution.
Copyright 2011 Tesco Corporation
TVSS

 The TVSS, or
Transient Voltage
Surge Suppressor,
reduces incoming
power issues such as
spikes or surges.

 The TVSS is designed


to fail before any
damage can be
sustained by the
MD500 Drive system.
Copyright 2011 Tesco Corporation
TVSS

Copyright 2011 Tesco Corporation


Control
Panel

Copyright 2011 Tesco Corporation


Control Panel Meters
 The Raw Bus and V Bus
meters are “Line Voltage
Meters”. They are not step
down meters and as such
have the actual voltage shown
present at the back terminals.

 Caution must be exercised


when checking these meters
as potentially harmful voltages
are present between 0 – 850
VDC ( they are rated for 0 to
1000 VDC)
Copyright 2011 Tesco Corporation
MD-500

Copyright 2011 Tesco Corporation


MD-500

 Supplies power for the


Top Drive motor.
 Converts both voltage
and frequency through
PWM technology.
 Works in conjunction
with the CCB (SCM).
 Designed for
synchronous operation.

Copyright 2011 Tesco Corporation


System Control Module
( Commercial Control Board )

Copyright 2011 Tesco Corporation


System Control Module
( Commercial Control Board )

 The System Control


Module is the interface
between the MD-500
and the outside world.

 Converts speed and


torque signals to
operate the inverter.

Copyright 2011 Tesco Corporation


PLC
( Programmable Logic Controller )

Copyright 2011 Tesco Corporation


PLC
( Programmable Logic Controller )

Copyright 2011 Tesco Corporation


PLC
( Programmable Logic Controller )

 Remote controller.
 Processes information
at high rate of speed.
 Located in main control
cabinet.

Copyright 2011 Tesco Corporation


PLC
( Programmable Logic Controller )

 Replaces multi conductor


cables from the Power
Module to the Drillers
Panel.
 Utilizes a communication
cable for the processing of
Inputs/Outputs rather than
24Volt relay logic.

Copyright 2011 Tesco Corporation


Lab View

Copyright 2011 Tesco Corporation


Lab View
 Interface between the
MD-500 and the real
world.
 Displays status of the
MD-500 and the Top
Drive.
 Includes temperatures,
voltages, current, and
fault codes.

Copyright 2011 Tesco Corporation


Lab View

 Used as a diagnostic
tool for the MD-500
and the Top Drive.
 Can be used to
manipulate the
operation of the Top
Drive system.

Copyright 2011 Tesco Corporation


Motor Starters

 Starters located
behind doors of the
starter panel.
 Used for the starting
of all the motors and
the setting of their
respective overloads
located on the
mechanical module.

Copyright 2011 Tesco Corporation


Braking resistors
 Enabled during a fault
condition that requires an
immediate shutdown or
to control over voltage
situations during unwind.

 All voltage present on the


MD-500 and produced
from the spinning Top
Drive is dissipated
immediately through the
brake resistors.

Copyright 2011 Tesco Corporation


Copyright 2011 Tesco Corporation
Copyright 2011 Tesco Corporation
Heat Pump

Copyright 2011 Tesco Corporation


Heat Pump

 Used for the cooling of


the Drive and control
cabinets.
 Cools air using glycol
from the chiller, located
in the mechanical
module, and circulates
this cooled air through
the cabinets.

Copyright 2011 Tesco Corporation


Dehumidifier

 The Building
Dehumidifier maintains
the humidity in the
power module at
approximately 30%. The
Dehumidifier is a
complete external unit,
it is not tied into the
control system.

Copyright 2011 Tesco Corporation


Control Distribution

24VDC Control UPS 120VAC

Copyright 2011 Tesco Corporation


UPS 120 VAC

 Un-interrupted Power
Supply.
 Provides back up
control power for the
System Controller in
the event of a rig
blackout.

Copyright 2011 Tesco Corporation


24VDC Control
 Main distribution for
robotics and sensors.
 Utilizes both 24VDC and
4-20 mA control
systems.
 Each terminal strip has
its own designation.
They are labeled MPA,
MPB, MPT, etc. as per
the actual Tesco
electrical schematic.
Copyright 2011 Tesco Corporation
Power Distribution

Copyright 2011 Tesco Corporation


Power Distribution

 Distributes main power


(600VAC) through out the
Top Drive system.
 Contains main breakers
for the MD-500 system.
 Voltage supplied from
incoming rig power or
stand alone generator.

Copyright 2011 Tesco Corporation


PA44-5W Motor

Copyright 2011 Tesco Corporation


PA44-5W Motor

 450 HP continuous.
 Synchronous.
 Liquid cooled.
 Continuous stall
torque of 1250 lb-ft.
in Connect mode.

Copyright 2011 Tesco Corporation


Resolver

Copyright 2011 Tesco Corporation


Resolver
 Mounted on the shaft, top side
of the PA44 motor.
 Determines absolute
positioning of the rotor in
relation to the stator.
 Signal sent to the CCB and
used to fire the MD-500 for
synchronous operation.
 Acts as bearing retainer for
upper motor bearing (old
style).
 Newer Resolvers come as 2
piece components so the
bearing retainer stays in
position while the Resolver is
replaced.
Copyright 2011 Tesco Corporation
Resolver

Copyright 2011 Tesco Corporation


Mechanical Module

Copyright 2011 Tesco Corporation


Mechanical Module

 Supplies all cooling and hydraulics for


the Top Drive and the power module.

Copyright 2011 Tesco Corporation


Main Components
of the Mechanical Module

 Chiller.  Flow switches.


 Top Drive pump.  Tank heater.
 Drive pump.  Oil level switch.
 Chiller by-pass pump.  Top drive temp switch.
 Auxiliary pump.  Auxiliary pressure
 Top drive cooling fan. switch.

Copyright 2011 Tesco Corporation


Chiller

Copyright 2011 Tesco Corporation


Chiller

 Used for the cooling of


the MD-500 drive system
only. When not
cooling, the
 10 or 25ton depending on
suction and
the amount of drives to discharge lines
be cooled. should be
 Set within 5 degrees of equal.
the Heat Pump setting to
prevent condensation.

Copyright 2011 Tesco Corporation


Top Drive Pump

Copyright 2011 Tesco Corporation


Top Drive Pump

 Circulates 50/50 glycol


through the Top Drive
cooling loop.
 Controlled from the
power module.
 Top Drive Motors need
7 GPM (3.5 per stator)
each.

Copyright 2011 Tesco Corporation


Drive Pump

Copyright 2011 Tesco Corporation


Drive Pump

 Supplies glycol to the


MD-500 system only.
 Must be running at all
times for the Top Drive
to operate.
 Each MD-500 Drive
requires 15 GPM.

Copyright 2011 Tesco Corporation


By-pass Pump

Copyright 2011 Tesco Corporation


By-pass Pump

 Used as a reserve
pump for the MD-500.
 Routes glycol through
the Top Drive fan via
an adjustable
manifold system.
 By-passes the chiller
in the case of failure
or service.

Copyright 2011 Tesco Corporation


COOLING SYSTEM
ECI 900

3SV

1SV

1SV

Copyright 2011 Tesco Corporation


Auxiliary Pump

Copyright 2011 Tesco Corporation


Auxiliary Pump

 Supplies all hydraulic oil


for the robotic functions
of the Top Drive.
 Controlled from either
the power module or
the drillers panel.
 10 HP motor coupled to
a P-30 pump supplying
7 GPM @ 2300 psi.

Copyright 2011 Tesco Corporation


SET @
2000 PSI

SET @ 2300 PSI

UNIT 337 AND BELOW Copyright 2011 Tesco Corporation


GRABBER LIFT ELEVATOR EXTEND GRABBER P.H. LOCK MUDSAVER UNLOADER TILT FLOAT

a A B b a A B b a A B b a A B b a A B b a A B b a A B b a A B b a A B b

P T P T P T P T P T P T P T P T P T

SET AT SET AT SET AT SET AT


1500 PSI 1500 PSI 1850 PSI 1850 PSI
2.8:1
T

P
SET AT SET AT
1850 PSI 1850 PSI

A1 P1 T1 A2 P2 B2 A3 B3 A4 B4 A5 B5 A6 B6 A7 B7 A8 B8 A9 B9 A10 B10

SET AT 0-3000 PSI


1500 PSI
T3 A2 B2 GP1 P2 P3
GL
P1 P
RM MR
SV
T2 T1 T
P.H. LOCK A1 B1 SET AT GP2 SET AT
600 PSI 2000 PSI

PRECHARGE PRECHARGE
1000 PSI 800 PSI

0-5000 PSI 0-5000 PSI


EXTEND

INNER CONN. 7A 7B 1A 1B 11A 11B 10A 10B 2A 2B 4A 4B 3A 3B 5A 5B 6A 6B 8A 8B 9A 9B 12A 12B

ROTARY SEAL

OUTER CONN. 7C 7D 1D 1C 11C 11D 10C 10D 2D P 2C 4D 4C 3C 3D 5C 5D 6C 6D 8C 8D 9C 9D 12C 12D


SET SEQ. VALVE
SET TO OBTAIN
SV TO 1000 PSI
4800 PSI AT
GAUGE "M" T
(APPROX. 800 PSI) PV
P1
SET AT
2000 PSI
PRECHARGE
PRECHARGE 1200 PSI
1200 PSI T INLET

MUDSAVER VALVE

6.5:1 TILT

COUNTER BALANCE HP P
ASSEMBLY

N.C.

AUXILIARY 0-10000 PSI


MANIFOLD
N.C.

A J L
0-5000 PSI M
SET AT
3000 PSI
G DRILLERS SIDE OFF DRILLERS SIDE

B N
K

1 C 3:1
NOTES:
N.C. GRABBER LIFT 1. ROTARY SEAL CONNECTIONS: "A" - INNER DRILLER SIDE
3 E F D H "B" - INNER OFF DRILLER SIDE
"C" - OUTER DRILLER SIDE
2
PRECHARGE "D" - OUTER OFF DRILLER SIDE
SET SO THAT
ELEVATOR DOORS FULLY CLOSE 2000 PSI
BEFORE LATCH BEGINS TO FUNCTION GRABBER
ELEVATOR SET @
2300 PSI

UNIT 338 AND ABOVE


Copyright 2011 Tesco Corporation
Top Drive Cooling Fan

Copyright 2011 Tesco Corporation


Top Drive Cooling Fan

 Cools glycol returning


from the Top Drive.
 Thermostatically or
“hand” controlled.
 10 HP 600 VAC motor
is mounted to an M-12
Modine heat
exchanger.

Copyright 2011 Tesco Corporation


Flow Switches

Copyright 2011 Tesco Corporation


Flow Switches

 Used as an interlock
for the Top Drive
system.
 Located on the return
side of the Drive and
the Top Drive cooling
loops.
 Wired in series.
 “No Flow, No Go”

Copyright 2011 Tesco Corporation


Oil Level Switch

Copyright 2011 Tesco Corporation


Oil Level Switch

 Low oil shutdown.


 Locks out aux.
Pump in a low oil
condition and when
the Drillers panel
ESD is depressed.

Copyright 2011 Tesco Corporation


Tank Heater

Copyright 2011 Tesco Corporation


Tank Heater

 Maintains operating
temperature of the
hydraulic fluid used for
the robotics system.

 Set for 30 C or 86 F.

Copyright 2011 Tesco Corporation


Top Drive Temperature
Switch

Copyright 2011 Tesco Corporation


Top Drive Temperature
Switch

 Controls the Top Drive


cooling fan.
 Set at 32 C or 90 F.
 Mounted on the Top
Drive cooling tank.

Copyright 2011 Tesco Corporation


Aux. Pressure Switch

Copyright 2011 Tesco Corporation


Aux. Pressure Switch

 Set at 800psi.
 Indicates pressure, by way of
an amber light on the Drillers
Panel, being produced by the
Aux. Pump during use of the
robotics.
 Normal circulating Pressure
should be approximately 300-
400 psi.

Copyright 2011 Tesco Corporation


Service Reel

Copyright 2011 Tesco Corporation


Service Reel

 Holds all electrical


cables, cooling lines,
and the hydraulic lines
for robotics.
 Commonly called the
service loop.

Copyright 2011 Tesco Corporation


Drillers Panel

Copyright 2011 Tesco Corporation


Drillers Panel

 Drillers interface with the Top Drive.


 Provides control for all robotic, speed, and
torque functions.
 Displays Set and Delivered speeds and
torques.
 Different coloured lights provide warnings
and status indication.

Copyright 2011 Tesco Corporation


Main Components
of the Drillers Panel

 Remote I/O (extension of main PLC).


 Drive set control functions.
 Set and Delivered Meters
 Draw works interlock.
 Mud pump interlock.

Copyright 2011 Tesco Corporation


Top Drive

Copyright 2011 Tesco Corporation


Top Drive

 Responsible for all the pipe handling


functions during the drilling operation.
 Pipe handling functions include
rotational and robotics.

Copyright 2011 Tesco Corporation


Main Components
of the Top Drive

 Robotics.
 PA44 motor.
 Resolver.
 Temperature sensors.
 Top Drive junction box.

Copyright 2011 Tesco Corporation


Robotics
 Pipe Handler lock.  Mud Saver open.
 Pipe Handler unlock.  Mud Saver close.
 Elevators open.  Grabber open.
 Elevators close.  Grabber close.
 Link Tilt forward.  Grabber Lift up.
 Link Tilt back.  Grabber Lift down.
 Extend in.  Pipe Handler Rotate.
 Extend out.

Copyright 2011 Tesco Corporation


Top Drive
Junction
Box

Copyright 2011 Tesco Corporation


Temperature Sensors

Copyright 2011 Tesco Corporation


Stator Temperature
 Two temperature sensors
for monitoring stator
windings (upper and Stator
lower).
 Thermistor type imbedded
into the stator windings
(cannot be field replaced).
 All rotor sensors are Rotor : Not Used
removed and capped. The
signal is “masked” with a
2.5 KΩ resistor.

Copyright 2011 Tesco Corporation