Professional Documents
Culture Documents
MDS
SD Series
Long Range IP/Ethernet & Serial
TM
MDS SD4 & MDS SD9 TM
g imagination at work
SD Series
The SD optimizes the use of narrow radio channels and increases the 4790 Master Station SDA with 4790 Master Station
throughput available for data traffic. This results in a higher usable
data speed that benefits Ethernet SCADA applications.
Fixed Remote
Tank Level
Pressure
Data Control
Temperature Center
Fixed Remote
Alarm
Metering
Master Station
Security
Fixed Remote
22 www.GEDigitalEnergy.com
SD Series
An SD Series remote radio can be used as a master. Full-Duplex Radio with redundancy option
Antenna Port
COM2 Serial Port (RS232/485,
Serial-to-Serial, IP-to-Serial)
COM1 Serial Port (Data & Local
Configuration)
10/100BaseT Ethernet Port
DC Power Port
(Data & Firmware Load)
www.GEDigitalEnergy.com 23
SD Series
Specifications
GENERAL Receiver Electrical
Frequency Type Double Conversion Tx Current 2.2A Typical at 5 Watts
Configurable Superheterodyne Rx Current <125 mA
Programmability
Operational modes Simplex, half-duplex Bit Error Rate 1x10-6 @ -112 dBm typical Sleep mode 9 mA nominal
Modulation Digital / CPFSK Selectivity >70dB SD4
Range Up to 50 miles Adjacent Channel Primary power 10.5 Vdc to 16 Vdc
Rejection 40 dB nominal SD9
SD4
Interfaces Primary power 10 Vdc to 30 Vdc
RF data rate & 4800 bps @ 6.25 kHz
bandwidth 9600 bps @ 12.5 kHz Serial COM1 RS-232, DB-9 Mechanical
19200 bps @ 25 kHz Serial COM2 RS-232, RS-485 DB-9 Case Rugged die-cast aluminum
Frequency bands 350 - 400 MHz Ethernet 10/100 BaseT, RJ 45 Dimensions 5.08 H x 14.29 W x 18.4 D cm.
400 - 450 MHz Antenna TNC Female (2.0 H x 5.625 W x 7.25 D in.)
450 - 512 MHz Management Weight 1 kg (2.2 lb.)
SD9 MDS InSite software Agency Approvals
RF data rate & 9,600 & 19,200 bps @ 12.5 kHz MDS NetView software CSA Class 1 Div 2 for hazardous locations
bandwidth 19200 bps @ 25 kHz MDS Radio Configuration software IEEE 1613 substation environment
Frequency bands 928-960 MHz Environmental FCC Part 90
Transmitter Temperature -40°C to +70°C (-40°F to Industry Canada & ENTELA
Frequency Stability +/- 0.5 ppm +158°F) SD4: ETSI, EMC, CE MARK (ETSI: ETS 300 113, EMC:
Carrier power 0.1 to 5 Watts Programmable Humidity 95% at 40C (104°F) non- EN 300 279)
Carrier power condensing SD9: Pending FCC Approval
Normal +/- 1.5 dB
Accuracy
Duty Cycle Continuous
Output Impedance 50 Ohms
Ordering
SD4 Remote
SD04MD- * ** -NNSNN
Sub -band A 350-400 MHz
B 400-450 MHz Order Code Example
C 450-512 MHz SD04MD-CSS-NNSNN
Model SS Serial
• Remote radio
ES Ethernet and Serial
• 450 - 512 MHz
MS 4710 Emulation
• Serial only communication
• Standard mounting brackets
• No special assembly
SD9 Remote
SD09MD- * ** -NNSNN
Sub -band C 928-960 MHz
Model SS Serial Order Code Example
ES Ethernet and Serial SD09MD-CES-NNSNN
MS 9710 Emulation
• Remote radio
• Ethernet and Serial
• Standard mounting brackets
• No special assembly
090209-v05