5002 5002

Changing the Specifications

Changes to Power Supply Specifications

Be sure to turn off the circuit breakers of the machine and the main power source before operation.

All power supply specifications can be changed by changing connections of the power supply terminal in the
control box, connecting terminal, and terminal TA1 on power PCB 1 and changing connectors (J66 and J67).

V30 V50

V30,V50,V100 Changing the Specifications


TA1
Power PCB 1

TA1
Power PCB 1

Connecting Power TR Connecting Power TR


terminal supply terminal terminal supply terminal

1/6
5002 5002
Changing the Specifications

V100

TR Connecting

V30,V50,V100 Changing the Specifications


terminal

TA1
Power PCB 1

Power
supply terminal

2/6
5002 5002
Changing the Specifications

1. Wiring changes

Wire Single-phase, two-wires Three-phase, three-wires Three-phase, four-wires


No. (AC 200V-AC 240V) (AC 200V-AC 240V) (AC 346V-AC 415V)
A R-T1 R-T1 R-T1
B S-T2 R-T3 S-T3
C R-T3 S-T2 N-T2
D S-T4 T-T4 N-T4
F T3-T5 T2-T5 T-T5
H T4-T6 T4-T6 T4-T6

2. Changing the connection of connectors (J66 and J67)

3. Changing the rating plate

V30 V50,V100

V30,V50,V100 Changing the Specifications


Rating plates

3/6
5002 5002
Changing the Specifications

Single-phase, two-wires (AC200V - AC240V)

TA1 J/P60
A
R T1
P67 P67 P67 200-210V 220-240V
B
S T2 200 220 240V P66 P66
C 208V 230V
R T3
D 0
S T4
F
T5
J67 J66 200/208
H
T6
E TR
220/230

U AC100V 240
P65
V

P65
J65

V30,V50 Power PCB 1 (J340008)

TA1 J/P60

V30,V50,V100 Changing the Specifications


A
R T1
P67 P67 P67 220-240V 200-210V
B
S T2 200 220 240V P66 P66
C 208V 230V
R T3
D 0
S T4
F
T5
J67 J66 200/208
H
T6
E J65 TR
220/230

U 240
V

AC100V
P65 P65

V100 Power PCB 1 (J340038)

Memo

Be careful that the positions of P66 (200-210V) and P66 (220-240V) in V30/50
(J340008) are opposite to the positions in V100 (J340038).

A
T1
L C
L1(L) R T3
B
T2
N D
L2(N) S T4

L3 T

N N

E Connecting terminal

Power supply terminal

( Wiring changes not required.)

4/6
5002 5002
Changing the Specifications

Three-phase, three-wires (AC200V - AC240V)

TA1 J/P60
A
R T1
P67 P67 P67 200-210V 220-240V
C
S T2 200 220 240V P66 P66
B 208V 230V
R T3
D 0
T T4
F
T5 J67 J66 200/208
H
T6
E TR
220/230

U 240
P65 AC100V
V

P65
J65

V30,V50 Power PCB 1 (J340008)

TA1 J/P60

V30,V50,V100 Changing the Specifications


A
R T1
P67 P67 P67 220-240V 200-210V
C
S T2 200 220 240V P66 P66
B 208V 230V
R T3
D 0
T T4
F
T5 J67 J66 200/208
H
T6
E J65 TR
220/230

U 240
V

AC100V
P65 P65

V100 Power PCB 1 (J340038)

Memo

Be careful that the positions of P66 (200-210V) and P66 (220-240V) in V30/50
(J340008) are opposite to the positions in V100 (J340038).

A
T1
L1 B
L1(L) R T3

L2 C
L2(N) S T2

L3 D
T4
L3 T

N N

E Connecting terminal

Power supply terminal

( Wiring changes not required.)

5/6
5002 5002
Changing the Specifications

Three-phase, four-wires (AC346V - AC415V)

TA1 J/P60
A
R T1
P67 P67 P67 200-210V 220-240V
C
N T2 200 220 240V P66 P66
B 208V 230V
S T3
D 0
N T4
F
T T5
J67 J66 200/208
H
T6
E TR
220/230

U AC100V 240
P65
V

P65
J65

V30,V50 Power PCB 1 (J340008)

TA1 J/P60

V30,V50,V100 Changing the Specifications


A
R T1
P67 P67 P67 220-240V 200-210V
C
N T2 200 220 240V P66 P66
B 208V 230V
S T3
D 0
N T4
F
T T5
J67 J66 200/208
H
T6
E J65 TR
220/230

U 240
V

AC100V
P65 P65

V100 Power PCB 1 (J340038)

Memo

Be careful that the positions of P66 (200-210V) and P66 (220-240V) in V30/50
(J340008) are opposite to the positions in V100 (J340038).

L1 A
L1(L) R T1

L2 B
L2(N) S T3
L3 F
L3 T T5
C
N T2
N N D
T4

E Connecting terminal

Power supply terminal

( Wiring changes not required.)

6/6
5011 5011
Changing the Specifications

Changing the Frequency

Do not put your hand close to the gear. Your hand may be trapped. If your hand or something is trapping,
ask someone near by to turn off the circuit breaker of this machine as soon as possible.

• Change the direction of the drive transfer gear.


• Change the wiring of the dryer fan connector J/P130 only for V100.

1. Remove the drive motor.

Refer to 2301 and 2302.

2. Change the direction of the drive transfer gear. (Two screws)

Screws

V30,50,V100 Changing the Specifications


Drive motor

Drive transfer gear

50 Hz

(V30,V100: 30T
V50: 24T ) 60 Hz

( V30,V100: 25T
V50: 20T )
Reducer

A key is attached to V50 and V100.

Memo
The above figure shows the drive transfer gear direction for 60 Hz.

3. Reassemble the drive motor as it was.

4. Adjust the backlash of the drive transfer gear.

Refer to 2301 and 2302.

5. Write the new frequency on the rating plate.

1/2
5011 5011
Changing the Specifications

6. The connector wiring of the dryer fan only for V100 must be changed.

6.1 Open the dryer cover.


Refer to 1002.

6.2 Open the wiring cover. (2 screws)

Wiring cover

Screws

V30,50,V100 Changing the Specifications


6.3 Change the wiring of connector J/P130 according to the frequency.

To power PCB 1

J130

P130 P130

50Hz 60Hz

Dryer fan

6.4 Reassemble the parts as they were.