ARMflo Circulators
FILE NO: 10.16
DATE: Feb. 17, 2006
SUPERSEDES: 10.16
DATE: Oct. 27, 2005
E Series
The smaller,
more efficient
ARMflo E Series
dry motor circulator.
The E Series circulators deliver outstanding value
to designers and specifiers, installing contractors,
wholesalers, OEM’s and building owners:
f Efficiency Breakthrough
Highly efficient dry motor design and hydraulics make E Series
circulators up to 74% more efficient than competitive pumps of
similar power!
f Excellent Value
With higher performance ratings than competitive pumps and a
comparable price, E Series circulators will save money right out of
the box. From installation and beyond, they will save building owners
money with reduced operating costs year after year.
f Environmentally Friendly
Never throw away another pump. E Series circulators are designed
to be economically repaired in less than 5 minutes by simply
replacing the mechanical seal, putting the pump back in operation
in no time!
fPerformance Curves
fTechnical Data
Model E7 E8 E9 E10 E11 E12* E13 E14* E15 E16 E17 E18 E19 E21 E22 E23 E24 E28 E29 E30 E33
Max. Flow 38.0 38.0 38.0 43.0 45.0 50.0 54.0 52.0 58 68.0 65 68 90 90 88 83 105 117.0 128 130.0 143.0
(2.4) (2.4) (2.4) (2.7) (2.8) (3.1) (3.4) (3.3) (3.7) (4.3) (4.1) (4.3) (5.7) (5.7) (5.6) (5.2) (6.6) (7.4) (8.1) (8.2) (9.0)
Max. Head 26.0 34.0 42.4 28.0 31.9 56.0 19.7 61.0 24.5 16.8 27.0 12.5 23.0 26.5 39.5 35.5 30.0 17.0 19.0 22.0 26.0
(7.9) (10.4) (12.9) (8.5) (9.7) (17.0) (6.0) (18.6) (7.5) (5.1) (8.2) (3.8) (7.0) (8.1) (12.0) (10.8) (9.1) (5.2) (5.8) (6.7) (7.9)
Max. Fluid Temperature: 230°F (110°C)
Max. Ambient Temperature: 122°F (50°C)
Max. Working Pressure: 150 psi (1034 kPa)
Notes: Flow in USgpm (L/s) and Head in feet (m). *Maximum fluid temperature for E12-TE and E14-TE is 150°F (65°C).
fMotor Data†
Model E7 E8 E9 E10 E11 E12 E13 E14 E15 E16 E17 E18 E19 E21 E22 E23 E24 E28 E29 E30 E33
Speed 3400 3250 3250 3300 3300 3300 3400 3300 3500 3400 3500 3500 3450 3450 3350 3400 3400 3450 3400 3350 3300
1 1/6 1/6 1/6 1/6 2/5 1/6 2/5 2/5 1/6 2/5 2/5 2/5 2/5 2/5 2/5 2/5 2/5 2/5 2/5 2/5
/6
Nominal Power
(125) (125) (125) (125) (125) (298) (125) (298) (298) (125) (298) (298) (298) (298) (298) (298) (298) (298) (298) (298) (298)
120 V 2.0 2.0 2.0 2.0 2.0 4.8 2.0 4.8 2.5 2.0 3.0 2.5 3.4 3.8 5.7 5.0 5.0 3.3 3.9 4.7 5.7
Full Load 208 V 1.0 1.0 1.0 -- -- 2.4 -- 2.4 1.8 -- 1.6 1.8 1.8 2.0 3.0 2.6 2.6 1.7 2.0 2.4 3.1
Amp Draw 240 V 1.0 1.0 1.0 1.0 1.0 2.4 1.0 2.4 1.8 1.0 1.6 1.8 1.8 2.0 3.0 2.6 2.6 1.7 2.0 2.4 3.1
277 V -- -- -- -- -- 2.4 -- 2.4 1.8 -- 1.6 1.8 1.8 2.0 3.0 2.6 2.6 1.7 2.0 2.4 3.1
Note: Speed in rpm, Nominal Power in hp (W) and Full Load Amp draw in Amps. † All motors are 2 pole, single phase. F
A
E
C
fMaterials of Construction
Pump Body: Cast Iron or Bronze Impeller: 30% Glass-filled Noryl
D
Face Plate & Shaft: Stainless Steel Seal: Silicon Carbide EnviroSeal
Gasket: EPDM Bearings: Permanently lubricated Stainless Steel B
IN-LINE Circulators
FILE NO: 1-3
DATE: December 2004
SUPERSEDES: K2.100
DATE: March 1998
S & H Series
In-Line Circulators
Design Features
The Series S & H in-line circulators are built using a standard three-piece design that features a
radially-split split body, oversized shaft, centrifugal impeller, positive mechanical seal and modular
construction.
▲
Body
The radially-split body can be left in the line while servicing the pump, eliminating cumbersome
disconnecting of pipes.
▲
Oversized Shaft
Armstrong circulating pumps have oversized shafts made from special alloy steel, machined to exacting
tolerances. Shafts have integral thrust collars, heat-treated to provide long life under severe duty
conditions.
▲
Centrifugal Impeller
The balanced, centrifugal-design impeller ensures maximum water delivery in the HVAC system.
▲
Modular Construction
Models S-25 through S-57 and H-32 through H-54 feature a unique Armstrong shaft and bearing
module which fits all of these models for ease of serviceability and reduced inventory costs
2
Standard three phase design
Pump and Motor Details
▲
Notes:
1. Dimensions given are for reference only. For exact dimensional data, contact factory.
2. All single phase motors are equipped with built-in thermal overload protection. Three
phase motors require external overload protection.
3. Companion flanges not furnished as standard on S-25, S-45 and H-32.
4. Conduit box not supplied on 1/2 hp or. greater
5. For other design characteristics, consult your Armstrong Representative.
3
▲
Materials of Construction
Iron Body Pump
Part Name Bronze Body Pump
Bronze-Fitted Construction
Volute Cast Iron Bronze
Impeller S-25 to S-57 Non-Ferrous Non-Ferrous
Impeller H-32 to H-54 Non-Ferrous Non-Ferrous
Impeller S-69 Brass-Stamped Brass-Stamped
Impeller H-63 to H-68 Cast Bronze Cast Bronze
Shaft Alloy Steel-Copper Sleeve Alloy Steel-Copper Sleeve
Mechanical Seal Assembly Carbon Brass Trim - Ceramic Seat
▲
Design Information
Iron Body Pump Bronze Body Pump
Bronze-Fitted Construction
Maximum Operating Temp. 225°F (107°C) 225°F (107°C)
Maximum S-25 to S-69, H-32, H-41 125 psi (862 kPa) 125 psi (862 kPa)
Working
Pressure H-51 to H-54, H-63 to H-68 175 psi (1207 kPa) 175 psi (1207 kPa)
Notes:
1. All circulators are to be mounted with pump and shaft in horizontal position. 2. For domestic hot water or fresh water systems, always specify bronze body pumps.
3. For temperatures over 225°F (107°C) consult your Armstrong Representative.
▲
Typical Specification
Furnish and install as shown on the plans, Armstrong Holden Brooke Pullen “S” or “H” Series Circulating Pump, designed for quiet
operation and guaranteed by the manufacturer for the intended application. The pump shall have a capacity of _____ L/s, handling (state
liquid and temperature) against a total head of ____ m. Pump shall be equipped with a ____ kW, ____ Volt, ____ phase,
_____ Hz, 1425 rpm drip-proof mounted motor.
Pump shall be ______ construction, three-piece design featuring the Armstrong shaft and bearing module which shall fit all models S-25
through S-57 and H-32 through H-54. The shaft shall have an integral thrust collar and shall be supported by oil-lubricated bronze sleeve
bearings. Pump to be equipped with a watertight, long-life ARMseal mechanical seal and be suitable for _____ kPa working pressure.
Experience Building...
Export Sales UK HVAC Sales North UK HVAC Sales South/Service
Peartree Road, Stanway Wenlock Way 21-23 Ormside Way
Colchester, Essex Manchester Holmethorpe Industrial Estate
United Kingdom, C03 0LP United Kingdom, M12 5JL Redhill, Surrey, RH1 2NT
T +44 (0)1206 579491 T +44 (0) 1612 232223 T +44 (0) 1737 378100
F +44 (0)1206 760532 F +44 (0) 1612 209660 F +44 (0) 1737 378140
E export@armlink.com E salesuk@armlink.com E salesuk@armlink.com