Industrial Hydraulic Valves

Directional Control, Pressure Control, Sandwich,


Subplates & Manifolds, Accessories
Catalog HY14-2500/US
Catalog HY14-2500/US Industrial Hydraulic Valves

WARNING – USER RESPONSIBILITY


FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.
• This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation
by users having technical expertise.
• The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance,
maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow
the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
• To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user
is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

OFFER OF SALE
The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are
governed by the provisions stated in the detailed “Offer of Sale” elsewhere in this document or available at www.parker.com/hydraulicvalve.

SAFETY GUIDE
For safety information, see Safety Guide SG HY14-1000 at www.parker.com/safety or call 1-800-CParker.

© Copyright 2011 Parker Hannifin Corporation, All Rights Reserved


Cat HY14-2500-frtcvr.indd, dd

II Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Contents

Introduction ....................................................................................................................................................B2 - B4
Series CM, ZRV
CM................................................ Check................................................................................................. B5 - B6
CM2.............................................. D03 Mounted, Check..........................................................................B7 - B8
CM3.............................................. D05 Mounted, Check........................................................................B9 - B10
CM6.............................................. D08 Mounted, Check......................................................................B11 - B12 B
ZRV.............................................. D03, D05 Mounted, Check..............................................................B60 - B62
Series CPOM, ZRE
CPOM........................................... Double Pilot Operated, Check.........................................................B13 - B14
CPOM2 Dimensions..................... D03 Mounted, Double Pilot Operated, Check.......................................... B15
CPOM3 Dimensions..................... D05 Mounted, Double Pilot Operated, Check.......................................... B16
CPOM6 Dimensions..................... D08 Mounted, Double Pilot Operated, Check......................................... B17
ZRE.............................................. D03, D05, D07 Mounted, Double Pilot Operated Check.................B57 - B59
Series FM, ZRD
FM................................................ Double Manapak, Flow Control.......................................................B18 - B20
FM2 Dimensions.......................... D03 Mounted, Double, Flow Control........................................................ B21
FM3 Dimensions.......................... D05 Mounted, Double, Flow Control........................................................ B22
FM6 Dimensions.......................... D08 Mounted, Double, Flow Control........................................................ B23
ZRD.............................................. D03, D05, D07 Mounted, Double Flow Control...............................B53 - B56
Series PRDM
PRDM........................................... Direct Operated, Pressure Reducing..............................................B24 - B27
PRDM2 Dimensions..................... D03 Mounted, Direct Operated, Pressure Reducing............................... B28
PRDM3 Dimensions..................... D05 Mounted, Direct Operated, Pressure Reducing............................... B28
Series PRM, ZDR
PRM............................................. Pressure Reducing.........................................................................B29 - B31
PRM3 Dimensions........................ D05 Mounted, Pressure Reducing..................................................B32 - B34
PRM6 Dimensions........................ D08 Mounted, Pressure Reducing........................................................... B35
ZDR.............................................. D03, D05, D07, Pilot Operated, Pressure Reducing.......................B42 - B44
Series RM, ZDV
RM................................................ Relief...............................................................................................B36 - B38
RM2 Dimensions.......................... D03 Mounted, Relief................................................................................ B39
RM3 Dimensions.......................... D05 Mounted, Relief................................................................................ B40
RM6 Dimensions.......................... D08 Mounted, Relief................................................................................ B41
ZDV.............................................. D03, D05, D07 Mounted, Relief......................................................B45 - B48
Series ZNS
ZNS ..............................................D03, D05 Mounted, Counterbalance Valve.....................................B49 - B52
Installation Information..............................................................................................................................B63 - B65
Mounting Pattern Dimensions..............................................................................................................B64 - B65

Parker Sandwich.indd, dd

B1 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Introduction Series CM, CPOM, FM, PRDM, PRM, RM, Z**

Sandwich valves provide a variety of check, flow con- The NFPA D03 Sandwich valves may also be used in
trol, pressure relief and pressure reducing functions in conjunction with Parker's Cartpak Series of sandwich
a compact NFPA D03, D05, D07 and D08 sandwich valves which offer a wide variety of additional func-
style valve. The NFPA D03 valve body conforms to tions including relief, pressure reducing/relieving, load
the ISO 40 mm (1.57") thickness. These valves are check, back pressure check, needle, flow control,
mounted between directional control valves and their pressure compensated flow control, crossover, relief
mounting surface. and directional valves.
B Check Valves
Series CM, ZRV
• Valve bodies are manufactured from steel which
provide extra strength and durability for longer life.
Internal hardened steel components also provide
longer life.
• Positive shut-off is provided by a fully guided CM*AA CM*AAF
poppet and allows full flow in the unchecked posi-
tion.
• Parker CM, ZRV sandwich style check valves can
be used either on the 'P', 'A', 'B', 'T' port or combi-
nation.
CM*BB CM*BBF
• Large internal flow paths allow high flow at low
pressure drop.

CM*DD CM*DDF

CM*PT CM*PP, ZRV-P CM*TT, ZRV-T

P.O. Check Valves


Series CPOM, ZRE
• Parker CPOM, ZRE sandwich style, pilot operated
check valves can be provided in either single or
double configurations.
• The pilot operated checks may be positioned in 'A'
port or 'B' port; or both 'A' and 'B' ports.
CPOM*AA, ZRE-A CPOM*BB, ZRE-B
• Valve bodies are manufactured from steel which
provide extra strength and durability for longer life.
Internal hardened steel components also provide
longer life.
• Large internal flow paths allow high flow at low CPOM*DD, ZRE-AB
pressure drop.

Parker Sandwich.indd, dd

B2 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Introduction Series CM, CPOM, FM, PRDM, PRM, RM, Z**

Flow Control Valves


Series FM, ZRD
• Parker FM, ZRD sandwich style flow control valves
can be provided in either single or double
configurations.
The flow controls may be positioned in 'P' port,
'A' port, 'B' port, or both 'A' and 'B' ports.
• Valve bodies are manufactured from steel which
FM*AA, ZRD-AA
(Meter Out)
B
provide extra strength and durability for longer life.
Internal hardened steel components also provide
longer life.
FM*BB, ZRD-BA
• Two step needles (standard) provide fine (Meter Out)
adjustment for the first three turns and course
adjustment for the last three turns. Fine metering
needles are available as an option on D03 and D05
valves.
FM*DD, ZRD-ABA
• Large bypass checks allow high flow at a low pres- (Meter Out)
sure drop.
• Reversible (invert 180°) for meter-in or meter-out
(D03 & D05 only).
FM*PP
(Meter Out)

Pressure Reducing Valves


Series PRDM
• PRDM sandwich valves may be selected to reduce
pressure in the 'P' port, 'A' port or 'B' port.
• The direct operated, cushioned piston design
results in fast response, low leakage and minimal
hysteresis.
• Up to nine pressure adjustment ranges are PRDM*PP
available with maximum pressure settings. T P A B

• Adjustment options include: internal hex screw, M


hand knob or internal hex with keylock.
• Fluorocarbon and nitrile seals are available for
multi-fluid compatibility. PRDM*AA
• Available gage port connections include SAE, NPT, T P A B

Metric and BSPP. M

PRDM*BB
T P A B

Parker Sandwich.indd, dd

B3 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Introduction Series CM, CPOM, FM, PRDM, PRM, RM, Z**

Pressure Reducing Valves


Series PRM, ZDR
• Parker PRM, ZDR sandwich style pressure reduc-
ing valves can be used to reduce pressure on the
'P' port, the 'A' port, or the 'B' port.
• Three pressure adjustment options available:
B slotted screw, knob and locking knob.
• Valve bodies are manufactured from steel which PRM*AA, ZDR-A
provide extra strength and durability for longer life.
Internal hardened steel components also provide
longer life.
PRM*BB, ZDR-B

PRM*PP, ZDR-P

Pressure Relief Valves


Series RM, ZDV
• Parker RM, ZDV sandwich style relief valve is a
'P' port to 'T' port relief.
• Valve bodies are manufactured from steel which
provide extra strength and durability for longer life.
Internal hardened steel components also provide
longer life. RM*PT, ZDV-P
• Three pressure adjustment options available:
slotted screw, knob and locking knob.

Parker Sandwich.indd, dd

B4 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series CM

General Description
Series CM check valves provide an integral, full flow
check valve in the pressure 'P' port, 'A' port, 'B' port, or
the tank 'T' port of the directional valve. Reverse flow is
blocked. The CM2 and CM3 sizes offer a combination
P&T check version.

Features B
• Valve bodies are manufactured from steel which provides
extra strength and durability for longer life. Internal hard-
ened steel components also provide longer life.
• Positive shut-off is provided by a fully guided poppet and
allows full flow in the unchecked position.
• Parker CM sandwich style check valves can be used
either on the 'P', 'A', 'B', 'T' ports, or combinations.
• Large internal flow paths allow high flow at low pressure
drop.

Specifications
CM2 CM3 CM6 PSI Bar CM3 Reverse Flow Check
500 34
Mounting NFPA D03, NFPA D05, NFPA D08, 75 PSI

Pattern CETOP 3, CETOP 5, CETOP 8,


NG6 NG10 NG25 400 27
45 PSI

Maximum 345 Bar 345 Bar 345 Bar


Pressure (5000 PSI) (5000 PSI) (5000 PSI) 300 20
Pressure

5 PSI
Maximum 76 LPM 113 LPM 340 LPM
Flow (20 GPM) (30 GPM) (90 GPM) 200 14

Cracking 0.3 Bar 0.3 Bar 0.3 Bar


Pressure (5 PSI), (5 PSI), (5 PSI) 100 7
3 Bar* 3 Bar*
(45 PSI), (45 PSI),
5 Bar* 5 Bar* 0
18.9 37.9 56.8 75.7 94.6 113.6
LPM 0
(75 PSI) (75 PSI) GPM 5 10 15 20 25 30
Flow
* Optional
PSI Bar CM6 Reverse Flow Check
500 34
Performance Curves
400 27
PSI Bar CM2 Reverse Flow Check
500 34

300 20
Pressure

75 PSI
400 27 75 PSI

200 14
45 PSI
300 20
Pressure

45 PSI

100 7
5 PSI
200 14 5 PSI

0
LPM 0 56.8 113.6 170.3 227.1 283.9 340.6
100 7 15 30 45 60 75 90
GPM
Flow
0 VISCOSITY CORRECTION FACTOR
LPM 0 18.9 37.9 56.8 75.7
GPM 5 10 15 20 Viscosity (SSU) 75 150 200 250 300 350 400
Flow % of P (Approx.) 93 111 119 126 132 137 141
Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure
Parker Sandwich.indd, dd drop will change per chart.

B5 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Ordering Information Series CM

CM *
Check Size Port Cracking Seal Design
Valve Pressure Series
NOTE:
Not required
when ordering.

B Code Description
2 NFPA D03
Code Description
PP* P Port Check
Code Type
Omit 5 PSI
Code Type
V Fluorocarbon
Subplate Mounting PT* P and T Port Checks Y 45 PSI* N Nitrile
3 NFPA D05 TT* T Port Check Z 75 PSI*
Subplate Mounting
DD A and B Port Checks * Not available
6 NFPA D08
Subplate Mounting AA A Port Check on 6 size.
BB B Port Check
AAF A Port Inverted
BBF B Port Inverted
DDF A and B Ports Inverted
* Not available on 6 size

Bold: Designates Tier I products and options.


Non-Bold: Designates Tier II products and options. These products will have longer lead times.

Manapak Bolt Kits


Size "2" Size "3"
Sandwich Sandwich D3W-30
No. of & Valve Bolt Bolt Length No. of & Valve D3DW & Bolt Length
Sandwich Combination Kit mm (in) Sandwich Combination D31*W* mm (in)

1 Sandwich & D1 BK243   73.2 (2.88) 1 Sandwich & D3 BK141   88.9 (3.50)
2 Sandwich & D1 BK225 111.3 (4.38) 2 Sandwich & D3 BK142 139.7 (5.50)
3 Sandwich & D1 BK244 152.4 (6.00) 3 Sandwich & D3 BK143 190.5 (7.50)
4 Sandwich & D1 BK245 190.5 (7.50)  Bolt Kits must be ordered separately. *D31VW with
internal pilot and internal drain only.
Size "6"
Unit Weight:
Sandwich & Valve Bolt Qty/ Torque CM2 0.8 kg (1.7 lbs.)
Combination Kit Description Kit IN-LBS
CM3 1.8 kg (3.9 lbs.)
Sandwich & D6*VW Valve BK121 1/2 - 13 x 5.25
1 6 80 CM6 7.7 kg (17 lbs.)
2 Sandwich & D6*VW Valve BK122 1/2 - 13 x 8.00 6 80
3 Sandwich & D6*VW Valve BK123 1/2 - 13 x 10.75 6 80
4 Sandwich & D6*VW Valve BK124 1/2 - 13 x 13.50 6 80
Note: Bolt Kits must be ordered separately.

Schematics

AA Option AAF Option BB Option BBF Option

DD Option DDF Option PP Option TT Option PT Option


Parker Sandwich.indd, dd

B6 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series CM2

Inch equivalents for millimeter dimensions are shown in (**)

14.5
7.0 (0.57)
(0.28)

B
T

45.0 A B
(1.77)

Top View

70.0
(2.76)

40.0 38.8
(1.57) (1.53)

3.2
(0.13)

3.2
(0.13)

Face View

A B

SHOWN WITHOUT O-RING PLATE

Bottom View

Note: Transfer the locating pin to the hole on the opposite side of the valve body for 'T' port option.
(Invert body 180°)

Parker Sandwich.indd, dd

B7 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Surface Patterns Series CM2

Bottom Views Top Views

P T

A B B
A

B
T P

TT PP/PT

P T

A B
A B

T P

DD DDF

P T

A B A B

T P

BB BBF

P T

A B A B

P
T

AA AAF
Parker Sandwich.indd, dd

B8 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series CM3

Inch equivalents for millimeter dimensions are shown in (**)

69.9 T T
B
(2.75)
B A

11.9
(0.47)
19.1
(0.75)
Top View

50.0 48.8
(1.97) (1.92)

92.1
(3.63)

Face View

SHOWN WITHOUT O-RING PLATE

Bottom View

Parker Sandwich.indd, dd

B9 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Surface Patterns Series CM3

Bottom Views Top Views

B A
T

B
T
T
T
B A

TT PP/PT

B A

T T
T T

B A

DD DDF

B
A
T T
T T
B A

AA AAF

B A
T T
T T
B A

BB BBF
Parker Sandwich.indd, dd

B10 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series CM6

Inch equivalents for millimeter dimensions are shown in (**)

Top View

Face View

Bottom View

Parker Sandwich.indd, dd

B11 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Surface Patterns Series CM6

Bottom Views Top Views

B T P Y
X A B

A B
T P Y X

DD DDF

T P Y
X A B

A B
T P Y
X

AA AAF

T P Y
X A B

A B
T P Y
X

BB BBF

Parker Sandwich.indd, dd

B12 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series CPOM

General Description
Series CPOM double pilot operated check valves block
leakage from the actuator ports to tank when the direc-
tional valve is in the center position.
NOTE: For max. response and shut off, a directional valve with both
cylinder ports drained to tank in the center position is recommend-
ed for use with sandwich double pilot operated check valves.

Features
• Parker CPOM sandwich style, p.o. check valves can be
B
provided in either single or double configurations.
• The p.o. checks may be positioned in 'A' port or 'B' port;

or both 'A' and 'B' ports.
• Valve bodies are manufactured from steel providing extra

strength and durability for longer life. Internal hardened
steel components also provide longer life.
• Positive shut-off is provided by a hardened poppet
and cage assembly.
• Large internal flow paths allow high flow at low
pressure drop.

Performance Curves Specifications


PSI Bar CPOM2 CPOM2 CPOM3 CPOM6
116 8
Mounting NFPA D03, NFPA D05, NFPA D08,
Pattern CETOP 3, CETOP 5, CETOP 8,
NG 6 NG 10 NG 25
Pressure Differential

87 6
Maximum 345 Bar 345 Bar 205 Bar
Pressure (5000 PSI) (5000 PSI) (3000 PSI)
free flow
58 4 Maximum 53 LPM 76 LPM 227 LPM
Flow (14 GPM) (20 GPM) (60 GPM)
@ 21 Bar @ 11 Bar @ 24 Bar
piloted open (305 PSI) (155 PSI) (350 PSI)
29 2 Pressure Drop Pressure Drop Pressure Drop
Cracking 1.0 Bar 0.3 Bar 0.4 Bar
Pressure (15 PSI) (5 PSI) (6 PSI)
0
LPM 0 12.5 25 37.5 50 Pilot Ratio
3:1 3:1 3:1
GPM 3.3 6.6 9.9 13.2
Flow Leakage 5 DPM 5 DPM 5 DPM

PSI Bar CPOM3 PSI Bar CPOM6


150 10.2
300 20.5
Pressure Differential

Pressure Differential

100 6.8
200 13.6
free flow
free flow

piloted open
50 3.4 100 6.8
piloted open

0 0
LPM 0 18.9 37.9 56.8 75.7 LPM 0 37.9 75.7 113.6 151.4 189.3 227.2
GPM 5 10 15 20 GPM 10 20 30 40 50 60
Flow Flow
Viscosity Correction Factor
Curves were generated using 100 SSU hy-
draulic oil. For any other viscosity, pressure Viscosity (SSU) 75 150 200 250 300 350 400
drop will change as per chart.
Percentage of ∆P (Approx.) 93 111 119 126 132 137 141
Parker Sandwich.indd, dd

B13 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Ordering Information Series CPOM

CPOM *
Pilot Size Poppet Cracking Seal Design
Operated Style Pressure Series
Check Valve NOTE:
Not required
when ordering.

B Code Description
2 NFPA D03
Code Description
DD Double Poppet
Code Type
Omit** 5 PSI
Code Type
N Nitrile
Subplate Mounting A and B Ports V Fluorocarbon
Y* 45 PSI
3 NFPA D05 AA A Port Only
Subplate Mounting Z* 75 PSI
BB B Port Only
* Available in
6 NFPA D08
Subplate Mounting size 2 only.
** 15 PSI on
CPOM2

Bold: Designates Tier I products and options.


Non-Bold: Designates Tier II products and options. These products will have longer lead times.

Bolt Kits
Size "2" Size "3"
Sandwich Sandwich D3W-30
No. of & Valve Bolt Bolt Length No. of & Valve D3DW & Bolt Length
Sandwich Combination Kit mm (in) Sandwich Combination D31*W* mm (in)

1 Sandwich & D1 BK243   73.2 (2.88) 1 Sandwich & D3 BK141   88.9 (3.50)
2 Sandwich & D1 BK225 111.3 (4.38) 2 Sandwich & D3 BK142 139.7 (5.50)
3 Sandwich & D1 BK244 152.4 (6.00) 3 Sandwich & D3 BK143 190.5 (7.50)
4 Sandwich & D1 BK245 190.5 (7.50) * D31VW with internal pilot and internal drain only.
Size "6"
No. of Sandwich & Valve Bolt Bolt Length Unit Weight:
Sandwich Combination Kit mm (in)
CPOM2D 0.8 kg (1.7 lbs.)
1 Sandwich & D6 BK121 133.4 (5.25) CPOM3D 4.4 kg (9.6 lbs.)
2 Sandwich & D6 BK122 203.2 (8.00) CPOM6D 9.5 kg (21.0 lbs.)
3 Sandwich & D6 BK123 273.1 10.75)
4 Sandwich & D6 BK124 342.9 (13.5)
Bolt Kits must be ordered separately.

Schematics

AA Option BB Option DD Option

Parker Sandwich.indd, dd

B14 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series CPOM2

Inch equivalents for millimeter dimensions are shown in (**)

33.5
(1.32)
B
T
7.0
(0.28) A
B
P

Top View 45.0


(1.77)
22.5
(0.89)

18.0
(0.71)
40.0
(1.57)
3.2
(0.13)

3.2
(0.13) End View
111.5
(4.39)

129.1
(5.08)

Face View

A B

Bottom View

Parker Sandwich.indd, dd

B15 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series CPOM3

Inch equivalents for millimeter dimensions are shown in (**)

46.0
(1.81)

B 11.9 P
(0.47)
A B
T T

Top View

69.9
(2.75)
38.2
(1.50)

50.0
(1.97) 28.7
(1.13)

146.1
(5.75) End View
165.1
(6.50)

Face View

Bottom View

Parker Sandwich.indd, dd

B16 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series CPOM6

Inch equivalents for millimeter dimensions are shown in (**)

B A
x

B
Y
P T

11.1
Top View (0.44) 114.3
11.1
(4.50)
(0.44)
63.5
(2.50)

23.8
(0.94)

69.5
(2.74)

6.4 6.4 (0.25) Locating pins


(0.25) (2 Places)
168.3
(6.62)
200.6 End View
(7.90)

Face View

Bottom View

Parker Sandwich.indd, dd

B17 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series FM

General Description
Series FM double flow control valves permit free flow
from the directional valve to the actuator and adjustable
independent flow regulation in each return line from the
actuator (meter-out). The FM2 and FM3 have a seal
plate and can be inverted for meter-in applications (see
installation drawing for flow direction).

B Features
• FM style flow control valves can be provided in either
single or double configurations.
• The flow controls may be positioned in 'A' port, 'B' port,
both 'A' and 'B' ports or 'P' port.
• Valve bodies are manufactured from steel providing extra
strength and durability for longer life. Internal hardened
steel components also provide longer life.
• Two step needles provide fine adjustment for the first
few turns and course adjustment for the last few turns.
Standard and fine adjustment needles available.
• Large bypass checks allow high flow at a low pressure
drop.
• Valve is reversible (invert 180°) for meter-in or
meter-out applications (FM2 and FM3 only). Specifications
• Adjustment options include Allen hex or hand knob. FM2 FM3 FM6
Performance Curves Mounting NFPA D03, NFPA D05, NFPA D08,
Pattern CETOP 3, CETOP 5, CETOP 8,
PSI Bar FM2 Reverse Flow Check NG 6 NG 10 NG 25
500 34
Maximum 345 Bar 345 Bar 205 Bar
400 27 Pressure (5000 PSI) (5000 PSI) (3000 PSI)
Maximum 76 LPM 113 LPM 341 LPM
Reverse Flow
Pressure

300 20
Check
Flow (20 GPM) (30 GPM) (90 GPM)
Cracking 0.3 Bar 0.3 Bar 0.3 Bar
200 14 Pressure (5 PSI) (5 PSI) (5 PSI)
P
100 7 2 Pressure Drop P A B T
Reference PP ✽ 2 2 1 ✽ See specific
1
0
7.6 15.1 22.7 30.3 37.9 45.4 53.0 60.6 68.1 75.7
Chart DD 1 ✽ ✽ 1 flow vs. turns
LPM 0
GPM 2 4 6 8 10 12 14 16 18 20 AA 1 ✽ 1 1
Flow BB 1 1 ✽ 1
Turns from Turns from
PSI Bar FM2 Standard Needle Closed PSI Bar FM2**D Fine Needle Closed
1500 102 1500 102 2 4 6 8 10
1 2 4 6

1200 80 1200 80
8
Pressure
Pressure

900 60 900 60

10
600 40 12 600 40
Full Full
Open Open
300 20 300 20

0 0
LPM 0 7.6 15.1 22.7 30.3 37.9 45.4 53.0 60.6 68.1 75.7 LPM 0 7.6 15.1 22.7 30.3 37.9 45.4 53.0 60.6 68.1 75.7
GPM 2 4 6 8 10 12 14 16 18 20 GPM 2 4 6 8 10 12 14 16 18 20
Flow Flow

Curves were generated using 100 SSU Viscosity Correction Factor


hydraulic oil @49°C (120°F). For any other Viscosity (SSU) 75 150 200 250 300 350 400
viscosity, pressure drop will change as per
chart. Percentage of ∆P (Approx.) 93 111 119 126 132 137 141
Parker Sandwich.indd, dd

B18 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Ordering Information Series FM

FM *
Flow Valve Size Meter Needles Adjustment Seal Design
Control Option Series
NOTE:
Not required
when ordering.
Code Description Code Type
2

NFPA D03
Subplate Mounting
N Nitrile
V Fluorocarbon
B
3 NFPA D05 Code Type
Subplate Mounting
*6 NFPA D08 S Allen Hex
Subplate Mounting K Knob
* FM6 - Meter out only

Code Description Code Description


AA Single Function Omit Standard
A Port Only D* Fine Meter
BB Single Function * D needle is the stan-
B Port Only dard needle in valves
DD A and B Ports used as pilot chokes.
Dual Function Not available on size 6.
PP** Single Function
P Port
** Not availabe on size 6.

Bold: Designates Tier I products and options.


Non-Bold: Designates Tier II products and options. These products will have longer lead times.

Bolt Kits
Size "2" Size "3"
Sandwich Sandwich D3W-30
No. of & Valve Bolt Bolt Length No. of & Valve D3DW & Bolt Length
Sandwich Combination Kit mm (in) Sandwich Combination D31*W* mm (in)
1 Sandwich & D1 BK243   73.2 (2.88) 1 Sandwich & D3 BK141   88.9 (3.50)
2 Sandwich & D1 BK225 111.3 (4.38) 2 Sandwich & D3 BK142 139.7 (5.50)
3 Sandwich & D1 BK244 152.4 (6.00) 3 Sandwich & D3 BK143 190.5 (7.50)
4 Sandwich & D1 BK245 190.5 (7.50) * D31VW with internal pilot and internal drain only.
Size "6"
No. of Sadnwich & Valve Bolt Bolt Length
Sandwich Combination Kit mm (in)
Unit Weight:
1 Sandwich & D6 BK121 133.4 (5.25)
FM2 1.7 kg (3.8 lbs.)
2 Sandwich & D6 BK122 203.2 (8.00)
FM3 2.4 kg (5.2 lbs.)
3 Sandwich & D6 BK123 273.1 (10.75)
FM6 7.9 kg (17.5 lbs.)
4 Sandwich & D6 BK124 342.9 (13.5)
Bolt Kits must be ordered separately.

Schematics

AA Option BB Option DD Option PP Option


Parker Sandwich.indd, dd

B19 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Performance Curves Series FM

Pressure Drop Reference Chart


PSI Bar FM3 Reverse Flow Check P A B T
500 34
PP ✽ 2 2 1
DD 1 ✽ ✽ 1
400 27 2 AA 1 ✽ 1 1

B
BB 1 1 ✽ 1
300 20
Pressure

✽ See specific flow vs. turns chart

200 14
Reverse
Flow
Check
100 7

P
1
0
LPM0 18.9 37.9 56.8 75.7 94.6 113.6
GPM 5 10 15 20 25 30
Flow

Turns
PSI Bar FM3 Standard Needle from Closed PSI Bar FM6 Reverse Flow Check
1500 102 500 34
1 2 4 6

1200 80 8 400 27

900 60 300 20
Pressure

Pressure

600 40 10 200 14
12
Full
300 20 Open 100 7

0 0
LPM0 18.9 37.8 56.8 75.7 94.6 113.6 LPM 0 38 76 114 151 189 227 265 303 341
GPM 5 10 15 20 25 30 GPM 10 20 30 40 50 60 70 80 90
Nominal Flow Flow

Turns Turns
PSI Bar FM3**D Fine Needle from Closed PSI Bar FM6 Standard Needle from Closed
1500 102 1500 102 1 2 3 4
1 2 3 4 6 8 5

1200 80 10
1200 80
6
12
900 60
Pressure

14
Full 900 60
Pressure

600 40 Open 8

300 20 10
600 40
12
14
0 16
LPM 0 18.9 37.9 56.8 75.7 94.6 113.6 Full
GPM 5 10 15 20 25 30 300 20 Open
Flow

0
LPM0 38 76 114 151 189 227 265 303 341
GPM 10 20 30 40 50 60 70 80 90
Nominal Flow
Parker Sandwich.indd, dd

B20 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series FM2

Inch equivalents for millimeter dimensions are shown in (**)

Note: For meter-in option, invert body 180°.


Parker Sandwich.indd, dd

B21 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series FM3

Inch equivalents for millimeter dimensions are shown in (**)

Note: For meter-in option, invert body 180°.


Parker Sandwich.indd, dd

B22 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series FM6

Inch equivalents for millimeter dimensions are shown in (**)

Parker Sandwich.indd, dd

B23 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series PRDM

General Description
Series PRDM are direct operated pressure reducing
valves that are used to regulate pressure in one area
of a hydraulic circuit at a predetermined level below
normal system pressure. Additionally, an integral
pressure relieving function for the secondary reduced

B pressure circuit is incorporated into the design.

Operation
These valves are “normally open” devices that allow
fluid to flow through the controlled port during their
non-actuated or “at rest” condition. When downstream
pressure exceeds the value set by the spring force,
the control piston moves off its seat, closing off the
flow path and thus reducing the fluid passing through
from the main system. The cushioned piston
modulates to maintain the preset pressure in this
branch of the hydraulic circuit. If, due to external
forces, the pressure continues to rise in this branch
circuit, the piston will keep moving against the spring
force allowing fluid to be drained to tank, thereby limit-
ing maximum pressure to the valve’s setting. Specifications
PRDM2 PRDM3
Features Mounting NFPA D03, NFPA D05,
• PRDM sandwich valves may be selected to Pattern CETOP 3, NG6 CETOP 5, NG10
reduce pressure in the 'P' port, 'A' port or 'B' port. Maximum
Operating
• The direct operated, cushioned piston design results in Pressure
fast response, low leakage and minimal hysteresis. P, A, B 350 Bar (5000 PSI) 315 Bar (4560 PSI)

• Up to nine pressure adjustment ranges are available with T 10 Bar (145 PSI) 10 Bar (145 PSI)
maximum pressure settings. Max. Flow 40 LPM (10.5 GPM) 80 LPM (21 GPM)
Maximum
• Adjustment options include: internal hex screw, hand Leakage
knob or internal hex with keylock. P-A 15 ml/min (1.0 cu. in.)
Pressure Code Range
• Fluorocarbon seals are available. Range 01 1.0 to 14 Bar (15 to 200 PSI)
02* 1.5 to 25 Bar (22 to 363 PSI)
• Available gage port connections include SAE, NPT, 05** 2 to 50 Bar (29 to 725 PSI)
Metric and BSPP. 06* 1.5 to 64 Bar (22 to 928 PSI)
10** 4 to 100 Bar (58 to 1450 PSI)
15** 6 to 150 Bar (87 to 2175 PSI)
16* 3 to 160 Bar (44 to 2320 PSI)
21 8 to 210 Bar (116 to 3045 PSI)
35* 10 to 315 Bar (147 to 4560 PSI)
Viscosity
Range 12 to 230 cSt / mm²/s (56 to 1066 SSU)
Filtration ISO Code 18/16/13 or Better
* PRDM2 only
** PRDM3 only.

Parker Sandwich.indd, dd

B24 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Ordering Information Series PRDM

PRDM
Pressure Size Port Pressure Adjustment Seal Gage Design
Reducing/ Reduction Range Port Series
Relieving NOTE:
Not required
when ordering.

B
Code Description
2 NFPA D03 Code Type
Code Type
Subplate Mounting N 1/4” NPT
3 NFPA D05 N Nitrile
S SAE #4 (UNF-2B 7/16-20)
Subplate Mounting V Fluorocarbon Adapter in PRDM3
M Metric
Code Type G 1/4" BSPP
Code Description
L Hex w/Key Lock
PP P Port Only
S Internal Hex
AA A Port Only Screw Adj.
BB B Port Only K Knob

Code Description
01 1 to 14 Bar (15 to 200 PSI)
02* 1.5 to 25 Bar (22 to 363 PSI) Bold: Designates Tier I products and options.
05** 2 to 50 Bar (29 to 725 PSI)
06* 1.5 to 64 Bar (22 to 928 PSI) Non-Bold: Designates Tier II products and options.
10** 4 to 100 Bar (58 to 1450 PSI) These products will have longer lead times.
15** 6 to 150 Bar (87 to 2175 PSI)
16* 3 to 160 Bar (44 to 2320 PSI)
21 8 to 210 Bar (116 to 3045 PSI)
35* 10 to 315 Bar (147 to 4560 PSI)
* PRDM2 only.
** PRDM3 only.

Bolt Kits
Size "2" Size "3"
Sandwich Sandwich D3W-30
No. of & Valve Bolt Bolt Length No. of & Valve D3DW & Bolt Length
Sandwich Combination Kit mm (in) Sandwich Combination D31*W* mm (in)

1 BK243   73.2 (2.88)


Sandwich & D1 1 Sandwich & D3 BK141   88.9 (3.50)
2 Sandwich & D1
BK225 111.3 (4.38) 2 Sandwich & D3 BK142 139.7 (5.50)
3 Sandwich & D1
BK244 152.4 (6.00) 3 Sandwich & D3 BK143 190.5 (7.50)
4 Sandwich & D1
BK245 190.5 (7.50) * D31VW with internal pilot and internal drain only.
Bolt Kits must be ordered separately.

Weights:
PRDM2 1.3 kg (2.9 lbs.)
PRDM3 2.6 kg (5.8 lbs.)

Schematics
T P A B T P A B T P A B

M M M

PP Option AA Option BB Option


Parker Sandwich.indd, dd

B25 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Performance Curves Series PRDM

NOTE: Lowest pressure setting dependent upon system resistance.

Parker Sandwich.indd, dd

B26 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Performance Curves Series PRDM

NOTE: Lowest pressure setting dependent upon system resistance.

Parker Sandwich.indd, dd

B27 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series PRDM

PRDM2
Inch equivalents for millimeter dimensions are shown in (**)

PRDM3
Inch equivalents for millimeter dimensions are shown in (**)

Parker Sandwich.indd, dd

B28 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series PRM

General Description
Series PRM reducing valves are used to regulate
pressure, in one area of a circuit, below normal sys-
tem pressure. This style valve is well suited to perform
this function as it mounts directly below the directional
control valve.

Operation B
These are "normally open" valves that allow fluid to
pass through the controlled port during typical opera-
tion. When downstream pressure rises above the
value set by an adjustable spring force, the control
pilot opens and allows the main spool to move from
a full open position. The main spool modulates to
maintain the desired "reduced pressure" downstream
of the valve. The PRM3 also has a relieving mode.

Features
• PRM sandwich style pressure reducing valves can be
used to reduce pressure on the 'P' port, the 'A' port, or
the 'B' port.
• Three pressure adjustment options are available: slotted
screw, knob and locking knob. (PRM6 only)
• Valve bodies are manufactured from steel which provide
extra strength and durability for longer life. Internal hard-
ened steel components also provide longer life.

Specifications
PRM3 PRM6 PRM3/PRM6
Mounting NFPA D05, NFPA D08, Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638:7)
Pattern CETOP 5, NG 10 CETOP 8, NG 25
Venting Connecting the vent port to tank allows the
Minimum 10 Bar (150 PSI) with rated flow, 150 SSU reducing valve to divert flow at minimum
Pressure oil, and fluid temperature of 38°C (100°F).1 pressure.
Maximum 345 Bar 345 Bar Remote Remote control valve connected to the vent
Pressure (5000 PSI) (5000 PSI) Control port can be used to control the pressure.2
Min. 3.78 LPM 3.78 LPM
Flow (1 GPM) (1 GPM) Drain Drain line from pilot valve is internally
Line connected to the tank port. Tank line
Maximum 64 LPM 189 LPM pressure is thus added to the valve setting.3
Flow (17 GPM) (50 GPM) 1 Change in flow, temperature or fluid (SSU) rating will affect valve
Pressure Code Pressure Range minimum pressure.
Range 07 10 to 70 Bar (150 - 1000 PSI) 2 Set main valve pressure 10 Bar (150 PSI) higher than remote pilot.
17 10 to 175 Bar (150 - 2500 PSI) 3 It is important that the drain line connection be taken into consideration
25 10 to 250 Bar (150 - 3500 PSI) when determining the minimum valve setting.
35 10 to 350 Bar (150 - 5000 PSI)

Parker Sandwich.indd, dd

B29 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Ordering Information Series PRM

PRM *
Pressure Size Port Pressure Adjustment Seal Gauge Port Drain Design
Reducing Reduction Range Series
Valve NOTE:
Not required
Code Type when ordering.

B
Code Description Omit* SAE
3 NFPA D05 S† SAE
Subplate Mounting N† NPT
6 NFPA D08 M† Metric
Subplate Mounting Code Type
G 1/4 BSPP
N Nitrile * PRM6 only.
Available Models
Code Description PRM3 PRM6 V Fluorocarbon † PRM3 only.

PP P Port Only ✓ Code Type


Code Type
AA A Port Only ✓ Omit Internal
BB B Port Only ✓ ✓ K Knob
Y External
PA P Port Reduced/Convertible ✓ L* Locking Knob
to A Port Reduced S Screw Adj.
AP A Port Reduced/Convertible ✓ * PRM6 only.
to P Port Reduced Unit Weight:
PRM3 3.0 kg (6.6 lbs.)
Code Description PRM6 5.6 kg (12.5 lbs.)
07 10 to 70 Bar (150 to 1000 PSI)
Bold: Designates Tier I products and options.
17 10 to 175 Bar (150 to 2500 PSI)
25 10 to 250 Bar (150 to 3500 PSI) Non-Bold: Designates Tier II products and options.
35 10 to 345 Bar (150 to 5000 PSI) These products will have longer lead times.

Bolt Kits
Size "3" Size "6"

Sandwich D3W-30 Sandwich


No. of & Valve D3DW & Bolt Length No. of & Valve Bolt Bolt Length
Sandwich Combination D31*W* mm (in) Sandwich Combination Kit mm (in)

1 Sandwich & D3 BK141   88.9 (3.50) 1 Sandwich & D6 BK121 133.4 (5.25)
2 Sandwich & D3 BK142 139.7 (5.50) 2 Sandwich & D6 BK122 203.2 (8.00)
3 Sandwich & D3 BK143 190.5 (7.50) 3 Sandwich & D6 BK123 273.1 (10.75)
* D31VW with internal pilot and internal drain only. 4 Sandwich & D6 BK124 342.9 (13.5)
Bolt Kits must be ordered separately.

Schematics
VALVE SIDE VALVE SIDE VALVE SIDE

PRM3

SUBPLATE SIDE SUBPLATE SIDE SUBPLATE SIDE

AA Option BB Option PP Option


‘A’ Port Reduced ‘B’ Port Reduced ‘P’ Port Reduced

PRM6

PA Option AP Option
Parker Sandwich.indd, dd

B30 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series PRM3

Performance Curves
Valve will not function in this region
PSI Bar PSI Bar
500 35 5000
1
300
30
400 4000

B
25 250

Pressure Drop
Pressure Drop

300 3000
20 200

15 150
200 2000
10 100
2 Minimum
100 1000 Setting
3
5 5 50
4
0 0
LPM 30 60 RELIEVING REDUCING
0
GPM 3 6 9 12 15 18 LPM 20 10 0 10 20 30
GPM 75 38 0 38 75 113
Flow Rate
Flow Rate

Mode Flow Path Viscosity Correction Factor


Viscosity (SSU) 75 150 200 250 300 350 400
P → P A → A B → B T→T
% of ∆P (approx.) 93 111 119 126 132 137 141
PP 1 2 3 4
AA 1 2 3 5 Curves were generated using 100 SSU hydraulic oil.
BB 1 2 3 5 For any other viscosity, pressure drop will change per chart.

NOTE: Lowest pressure setting dependent upon system resistance.

Parker Sandwich.indd, dd

B31 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series PRM3

PRM3AA
Inch equivalents for millimeter dimensions are shown in (**)

Parker Sandwich.indd, dd

B32 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series PRM3

PRM3BB
Inch equivalents for millimeter dimensions are shown in (**)

Parker Sandwich.indd, dd

B33 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series PRM3

PRM3PP
Inch equivalents for millimeter dimensions are shown in (**)

Parker Sandwich.indd, dd

B34 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series PRM6

Inch equivalents for millimeter dimensions are shown in (**)

Top View

Face View End View

Bottom View

Parker Sandwich.indd, dd

B35 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series RM

General Description
Series RM relief valves limit system pressure by
opening to tank when system pressure reaches the
valve setting. With D03 size, they can also be config-
ured to limit the 'A' or 'B' work port pressures indepen-
dently.

B Features
• RM sandwich style relief valves can be used to limit pres-
sure in the 'P' port, 'A' port, or 'B' port.
• Valve bodies are manufactured from steel which provide

extra strength and durability for longer life. Internal hard-
ened steel components also provide longer life.
• Three pressure adjustment options are available: slotted
screw, knob and locking knob.
• SAE Gage Port

Specifications
RM2 RM3 RM6
Mounting NFPA D03, NFPA D05, NFPA D08, Performance Curves
Pattern CETOP 3, CETOP 5, CETOP 8,
NG 6 NG 10 NG 25
Minimum 10 Bar (150 PSI) with rated flow, 150 SSU
PSI Bar RM2 Override Characteristics
5000 341
Pressure oil, and fluid temperature of 38°C (100°F).1
35 spring
Maximum 350 Bar 350 Bar 350 Bar
4000 273
Pressure (5000 PSI) (5000 PSI) (5000 PSI)
25 spring
Minimum 3.78 LPM 3.78 LPM 3.78 LPM
Flow (1 GPM) (1 GPM) (1 GPM) 3000 205
Pressure

Maximum 53 LPM 76 LPM 341 LPM 17 spring


Flow (14 GPM) (20 GPM) (90 GPM) 2000 136
Pressure Code Pressure Range 07 spring
Range 07 10 to 70 Bar (150 - 1000 PSI)
1000 68
17 10 to 175 Bar (150 - 2500 PSI)
25 10 to 250 Bar (150 - 3500 PSI) Min setting
35 10 to 350 Bar (150 - 5000 PSI) 0
LPM 0 18.9 37.9 56.8
Filtration ISO 4406 (1999); 18/16/13 GPM 5 10 15
(meet NAS 1638:7) Flow
Venting Connecting the vent port to tank allows
the relief valve to divert flow at minimum
VISCOSITY CORRECTION FACTOR
pressure.2
Viscosity (SSU) 75 150 200 250 300 350 400
Remote Remote control valve connected to the vent % of ∆P (Approx.) 93 111 119 126 132 137 141
Control port can be used to control the pressure.3 Curves were generated using 100 SSU hydraulic oil. For any other viscosity,
1 Change in flow, temperature or fluid (SSU) rating will affect valve pressure drop will change per chart.

minimum pressure.
2 Not available on Model RM2.
3 Set main valve pressure 10 Bar (150 PSI) higher than remote
pilot.

Parker Sandwich.indd, dd

B36 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Ordering Information Series RM

RM *
Relief Valve Size Port Pressure Adjustment Seal Design
Option Range Series
NOTE:
Not required
when ordering.
Code Description

B
Code Type
2 NFPA D03
N Nitrile
Subplate Mounting
V Fluorocarbon
3 NFPA D05
Subplate Mounting
Code Type
6 NFPA D08
Subplate Mounting K Knob
L Locking Knob
Code Description S Slotted Screw
with Jam Nut
PT Relief P to T
AT* Relief A to T Code Description Unit Weight:
BT* Relief B to T 07 10 to 70 Bar (150 to 1000 PSI) RM2 .95 kg (2.1 lbs.)
17 10 to 175 Bar (150 to 2500 PSI) RM3 3.0 kg (6.6 lbs.)
* RM2 only.
RM6 5.9 kg (13.0 lbs.)
25 10 to 250 Bar (150 to 3500 PSI)
35 10 to 350 Bar (150 to 5000 PSI)

Bold: Designates Tier I products and options.


Non-Bold: Designates Tier II products and options. These products will have longer lead times.

Bolt Kits
Size "2" Size "3"
Sandwich Sandwich D3W-30
No. of & Valve Bolt Bolt Length No. of & Valve D3DW & Bolt Length
Sandwich Combination Kit mm (in) Sandwich Combination D31*W* mm (in)

1 Sandwich & D1 BK243   73.2 (2.88) 1 Sandwich & D3 BK141   88.9 (3.50)
2 Sandwich & D1 BK225 111.3 (4.38) 2 Sandwich & D3 BK142 139.7 (5.50)
3 Sandwich & D1 BK244 152.4 (6.00) 3 Sandwich & D3 BK143 190.5 (7.50)
4 Sandwich & D1 BK245 190.5 (7.50) * D31VW with internal pilot and internal drain only.
Size "6"
No. of Sandwich & Valve Bolt Bolt Length
Sandwich Combination Kit mm (in)

1 Sandwich & D6 BK121 133.4 (5.25)


2 Sandwich & D6 BK122 203.2 (8.00)
3 Sandwich & D6 BK123 273.1 (10.75)
4 Sandwich & D6 BK124 342.9 (13.5)
Bolt Kits must be ordered separately.

Schematics

AT Option BT Option PT Option

Parker Sandwich.indd, dd

B37 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Performance Curves Series RM

PSI Bar RM3 Override Characteristics PSI Bar RM6 Override Characteristics
25 spring 25 spring
3000 205 3000 205

B 17 spring 17 spring
Pressure

Pressure
2000 136 2000 136

07 spring 07 spring
1000 68 1000 68

Min setting Min setting

0 0
LPM 0 18.9 37.9 56.8 75.7 LPM 0 95 189 284 379
GPM 5 10 15 20 GPM 25 50 75 100
Flow Flow

PSI Bar RM3 Vent Flow PSI Bar RM6 Vent Press vs. Flow
70 4.8

60 4.1 150 10.2

50 3.4
Pressure

Pressure

40 2.7 100 6.8

30 2.1

20 1.4 50 3.4

10 .7

0 0
LPM0 18.9 37.9 56.8 LPM 0 25 189 284 379
GPM 5 10 15 GPM 25 50 75 100
Flow Flow

VISCOSITY CORRECTION FACTOR


Viscosity (SSU) 75 150 200 250 300 350 400
% of ∆P (Approx.) 93 111 119 126 132 137 141
Curves were generated using 100 SSU hydraulic oil. For any other viscosity,
pressure drop will change per chart.

Parker Sandwich.indd, dd

B38 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series RM2

Inch equivalents for millimeter dimensions are shown in (**)

169.4
(6.49) 41.4

9.0
(1.63)
@Low Pressure
34.8
(1.37)
B
(0.35)
@Max. Pressure
7.0 T
(0.28) A B
P

3.5
(0.14)
Top View

45.0
(1.77)

SAE 4
40.0
(1.57)

PT Body Shown 3.2 3.2 Pilot Cartridge Is Located


Gage Port Location (0.13) (0.13) 128.0 On The Right Side
Varies from AT Body (5.04) For PT Body And BT Body
and BT Body 170.3 (6.70) @ Max. Pressure
177.0 (6.97) @ Low Pressure
End View
Face View

88.0
(3.46)
45.2 (1.78)
P
Needed for 26.2
key removal (1.31)
A B
T

Bottom View

Parker Sandwich.indd, dd

B39 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series RM3

Inch equivalents for millimeter dimensions are shown in (**)

186.6
(7.35) 41.4
(1.63)
@ Low Pressure
34.8
(1.37)
@ Max.
Pressure

B T
B A
T

72.2 11.9
(2.84) (0.47)
69.9
Top View (2.75)
45.6
(1.80)
15.9
(0.63)
21.4 VENT
27.8
(0.84)
50.0 (1.09)
(1.97)

145.3 End View


(5.71)
187.6 (7.39) @Max. Pressure
194.2 (7.65) @Low Pressure

Face View

45.2 (1.78)
Needed for
key removal 26.2
(1.31)

88.0
(3.46)
Bottom View

GAGE

93.7 SAE 4
19.8 (3.69)
(0.78)
Back View

Parker Sandwich.indd, dd

B40 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series RM6

Inch equivalents for millimeter dimensions are shown in (**)

Top View

End View
Face View

Bottom View

Parker Sandwich.indd, dd

B41 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZDR

General Description
Series ZDR pilot operated pressure reducing valves
are designed for maximum flow rates.

The reducing function can be located in the ports P, A


or B. The sizes NG06 and NG10 are equipped with an

B integral return flow check valve (reducing function in A


or B).
ZDR-P01 ZDR-B01

Features
• High flow capacity.
• Sizes::
– ZDR01 – NFPA D03 / NG6 / CETOP 3
– ZDR02 – NFPA D05 / NG10 / CETOP 5

• With integral return flow check valve.


ZDR-B02

Specifications
General
Size NG6 NG10
Mounting Interface DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05
CETOP RP 121 CETOP RP 121
Mounting Position Unrestricted
Ambient Temperature Range -20°C to +50°C (-4°F to +122°F)
Hydraulic
Maximum Operating Pressure up to 350 Bar (5075 PSI); ZDR-AR / BR up to 315 Bar (4568 PSI)

Nominal Flow 80 LPM (21.2 GPM) 120 LPM (31.7 GPM)


Pilot Oil 0.2 LPM (0.1 GPM) 0.3 LPM (0.1 GPM)
Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20°C to +80°C (-4°F to +176°F)
Viscosity   Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)

Denison Sandwich.indd, dd

B42 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZDR

Ordering Information
ZDR S0 D
Pressure Port Size Pressure Hexagon Screw Design Seal
Reducing Option Range with Lock Nut Series
Valve

B
Code Description Code Description Code Description
01 NFPA D03 / NG6 1 up to 100 Bar (1450 PSI) 1 Nitrile
02 NFPA D05 / NG10 5* up to 350 Bar (5075 PSI) 5 Fluorocarbon

* AR/BR 325 Bar (4568 PSI)


Code Size Description
P 01/02 Pressure reducing in P
with pressure gauge port M
AR 01/02 Pressure reducing in A
with check valve
Weight: ZDR-P ZDR-AR/BR
BR 01/02 Pressure reducing in B
ZDR*01 1.6 kg (3.5 lbs.) 1.8 kg (4.0 lbs.)
with check valve
ZDR*02 2.9 kg (6.4 lbs.) 3.0 kg (6.6 lbs.)

ZDR01 ZDR02

Performance Curves
ZDR-P/AR/BR01 ZDR-P/AR/BR02

Denison Sandwich.indd, dd

B43 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series ZDR

ZDR01 – Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code
1 098-91184-0
5 098-91185-0
Complete Cartridge
Seal Order Code
1 098-91102-0
5 098-91103-0

ZDR02 – Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code
1 098-91182-0
5 098-91183-0
Complete Cartridge
Seal Order Code
1 098-91102-0
5 098-91103-0

Denison Sandwich.indd, dd

B44 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZDV

General Description
Series ZDV pilot operated pressure relief valves are
designed for maximum flow rates.
The relief function can be located between P and T,
A and T, B and T or A and T + B and T for typical pres-
sure relief functions.
For a pre-charge function the ZDV can be ordered with B
pressure function between A and B + B and A. ZDV-P01 ZDV-B01

Features
• High flow capacity.
• Pressure function in P, A, B or A + B.
• Sizes:
– ZDV01 – NFPA D03 / NG6 / CETOP 3
– ZDV02 – NFPA D05 / NG10 / CETOP 5
ZDV-B02

Ordering Information

ZDV S0 D
Pressure Port Size Pressure Hexagon Screw Design Seal
Relief Option Range with Lock Nut Series
Valve

Code Description Code Description Code Description


01 NFPA D03 / NG6 1 up to 70 Bar (1015 PSI) 1 Nitrile
02 NFPA D05 / NG10 5* up to 350 Bar (5075 PSI) 5 Fluorocarbon

* ABS 315 Bar (4568 PSI)


Code Size Description
P 01/02 P–T
A 01/02 A–T
B 01/02 B–T
AB 01/02 A–T&B–T Weight: One Cartridge Two Cartridges
ABS 01/02 A–B&B–A ZDV*01 1.6 kg (3.5 lbs.) 2.5 kg (5.5 lbs.)
ZDV*02 3.0 kg (6.6 lbs.) 3.7 kg (8.2 lbs.)

Denison Sandwich.indd, dd

B45 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZDV

Ordering Information
ZDV01

ZDV02

Specifications
General
Size NG6 NG10
Mounting DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05
CETOP RP 121 CETOP RP 121
Mounting Position Unrestricted
Ambient Temperature Range -20° to +50°C (-4°F to +122°F)
Hydraulic
Maximum Operating Pressure up to 350 Bar (5075 PSI); ZDV*ABS up to 315 Bar (4568 PSI)

Nominal Flow 80 LPM (21.2 GPM) 140 LPM (37.0 GPM)


Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20° to +80°C (-4°F to +176°F)
Viscosity Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Denison Sandwich.indd, dd

B46 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Performance Curves Series ZDV

ZDV-P/A/B/ABS01 ZDV-AB01

ZDV-P/A/B/AB02 ZDV-ASB02

Denison Sandwich.indd, dd

B47 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series ZDV

ZDV01 – Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code
1 098-91182-0
5 098-91183-0
Complete Cartridge
Seal Order Code
1 098-91116-0
5 098-91117-0

ZDV02 – Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code
1 098-91076-0
5 098-91077-0
Complete Cartridge
Seal Order Code
1 098-91116-0
5 098-91117-0

Denison Sandwich.indd, dd

B48 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZNS

General Description
Series ZNS counterbalance valve controls the actuator
movement at overrunning loads.
The return flow from the actuator is piloted and con-
trolled by the inlet flow to the actuator, ensuring a
cavitation-free lowering of the load.
The counterbalance valve operates as a pressure relief B
valve. The setting pressure is lowered by the pressure ZNS-AB01 ZNS-B01
in the inlet line. To ensure safe load holding the setting
pressure should be approximately 30% higher than the
max. load pressure.

Features
• Controlled movement loads.
• Load holding via leak-free poppet valve.
• Secondary relief protection for the actuator.
• Sizes:
ZNS-B01
ZNS*01 – NFPA D03 / NG6 / CETOP 3
ZNS*02 – NFPA D05 / NG10 / CETOP 5

Ordering Information
ZNS S0 D
Counterbalance Port Size Pressure Hexagon Screw Design Seal
Valve Option Range with Lock Nut Series

Code Description Code Description Code Description Code Description


A in A 01 NFPA D03 / NG6 2 70 to 175 Bar (1015 to 2538 PSI) 1 Nitrile
B in B 02 NFPA D05 / NG10 5 1) 140 to 350 Bar (2030 to 5075 PSI) 5 Fluorocarbon
AB in A and B 1)
ZNS02 to 315 Bar (4568 PSI)

Weight: 1 cartridge 2 cartridges


ZNS*01 1.3 kg (2.9 lbs.) 3.0 kg (6.6 lbs.)
ZNS*02 1.6 kg (3.5 lbs.) 3.9 kg (8.6 lbs.)

ZNS01 ZNS02

Denison Sandwich.indd, dd

B49 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Specifications Series ZNS

Specifications
General
Size NG6 NG10
Mounting Interface DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05

B Mounting Position Unrestricted


Ambient Temperature Range -20°C to +50°C (-4°F to +122°F)
Hydraulic
Maximum Operating Pressure 350 Bar (5075 PSI) 315 Bar (4568 PSI)

Pressure Range 175 Bar (2538 PSI), 350 Bar (5075 PSI)
Pilot Ratio 4.5 : 1
Leakage On request
Nominal Flow 60 LPM (15.9 GPM) 120 LPM (31.7 GPM)
Opening Pressure 0.3 LPM (0.1 GPM) 0.3 LPM (0.1 GPM)
Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20°C to +80°C (-4°F to +176°F)
Viscosity Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)

Denison Sandwich.indd, dd

B50 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Performance Curves Series ZNS

ZNS01

ZNS02

All characteristic curves measured with HLP46 at 50°C (122°F).

Denison Sandwich.indd, dd

B51 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series ZNS

ZNS01 – Inch equivalents for millimeter dimensions are shown in (**)

B
Seal Kit
Seal Order Code
1 098-91153-0
5 098-91154-0
Complete Cartridge
Seal Order Code
1 517-01017-2
5 517-00448-8

ZNS02 – Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code
1 098-91155-0
5 098-91183-0
Complete Cartridge
Seal Order Code
1 517-00449-8
5 517-00450-8

Denison Sandwich.indd, dd

B52 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZRD

General Description
Series ZRD throttle check valves are designed for
maximum flow rates.
The throttle check function can be located in port A or
B as well as in A + B. Meter-in or meter-out functional-
ity can be selected by model code.
A low flow / high resolution version in NFPA 03 / NG6 B
for sensitive shifting time adjustment of pilot operated ZRD-ABZ01 ZRD-AA02
directional control valves is available on request.

Features
• High flow capacity.
• Various functional arrangements.
• Sizes:
– ZRD01 – NFPA D03 / NG6 / CETOP 3
– ZRD02 – NFPA D05 / NG10 / CETOP 5
ZRD-AA02
Ordering Information
ZRD S0 D
Throttle Valve Meter Size Hexagon Design Seal
with Check Option Screw with Series
Lock Nut
Code Description Code Description
AA Meter-out 1 Nitrile
Code Description
Control in A 5 Fluorocarbon
01 NFPA D03 / NG6
AZ Meter-in
Control in A 02 NFPA D05 / NG10
BA Meter-out
Control in B
BZ Meter-in
Control in B
ABA Meter-out
Control in A and B Weight: 1 Cartridge 2 Cartridges
ABZ Meter-in ZRD*01 1.2 kg (2.6 lbs) 1.3 kg (2.9 lbs)
Control in A and B ZRD*02 2.8 kg (6.2 lbs.) 2.9 kg (6.4 lbs.)

ZRD01

ZRD02
(continued on
next page)
Denison Sandwich.indd, dd

B53 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Ordering Information Series ZRD

Ordering Information
ZRD02

Specifications
General
Size NG6 NG10
DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
Mounting
NFPA D03 NFPA D05
CETOP RP 121 CETOP RP 121 5
Mounting Position Unrestricted
Ambient Temprature -20°C to +50°C (-4°F to +122°F)
Hydraulic
Max. Operating Pressure 350 Bar (5075 PSI)
Nominal Flow 80 LPM (21.2 GPM) 160 LPM (42.3 GPM)
Leakage — —
Cracking Pressure — —
Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20°C to +80°C (-4°F to +176°F)
Viscosity
  Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
 Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)

Denison Sandwich.indd, dd

B54 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Performance Curves Series ZRD

p/Q Performance Curves


ZRD01

ZRD02

* Throttle closed
Fluid Viscosity 30 cSt @ 50°C (122°F)

Denison Sandwich.indd, dd

B55 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series ZRD

ZRD01
Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code

B
1 098-91096-0
5 098-91097-0
Complete Cartridge
Order Code
098-91119-0
O-ring Plate
Order Code
S26-27553-0

ZRD02
Inch equivalents for millimeter dimensions are shown in (**)
Seal Kit
Seal Order Code
1 098-91098-0
5 098-91099-0
Complete Cartridge
Order Code
098-91120-0
O-ring Plate
Order Code
S16-85742-0

Denison Sandwich.indd, dd

B56 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZRE

General Description.
Series ZRE pilot operated check valves are designed
for maximum flow rates and long life time.
The valves are typically used in combination with spool
type directional control valves to ensure leak free posi-
tioning of the actuator.
The inlet flow is free while the outlet flow is blocked. B
Pressure in the inlet line opens the check valve and ZRE-B01 ZRE-A02
allows free outlet flow.

Features
• High life time.
• Check function in A, B or A + B.
• Sizes:
– ZRE01 – NFPA D03 / NG6 / CETOP 3
– ZRE02 – NFPA D05 / NG10 / CETOP 5

ZRE-A02
Ordering Information

ZRE
Pilot Operated Port Size Design Seal
Check Valve Option Series

Code Description Code Description Code Description Code Description


A Blocked in A 01 NFPA D03 / NG6 D Size 01 1 Nitrile
B Blocked in B 02 NFPA D05 / NG10 E Size 02 5 Fluorocarbon
AB Blocked in A
and B Weight:
ZRE*01 1.2 kg (2.6 lbs)
ZRE*02 3.1 kg (6.8 lbs.)
ZRE01

ZRE02

Denison Sandwich.indd, dd

B57 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZRE

Specifications
General
Size NG6 NG10
DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
Mounting Interface
NFPA D03 NFPA D05
B Mounting Position Unrestricted
CETOP RP 121 CETOP RP 121 5

Ambient Temprature -20°C to +50°C (-4°F to +122°F)


Hydraulic
Max. Operating Pressure 350 Bar (5075 PSI)
Nominal Flow 60 LPM (15.9 GPM) 120 LPM (31.7 GPM)
Opening Ratio
1:6 1:6
(Pilot Cone/Main Cone)
Cracking Pressure 1.2 Bar (17.4 PSI) 2.0 Bar (29.0 PSI)
Fluid Hydraulic oil in accordance with DIN 51524 ... 51525
Fluid Temperature -20°C to +80°C (-4°F to +176°F)
Viscosity
 Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
 Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)

Performance Curves
p/Q
ZRE01 ZRE02

Fluid Viscosity 30 cSt at 50°C (122°F).

Denison Sandwich.indd, dd

B58 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series ZRE

ZRE01
Inch equivalents for millimeter dimensions are shown in (**)

Seal
Seal Kit
Order Code
B
1 098-91088-0
5 098-91089-0

ZRE02
Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code
1 098-91090-0
5 098-91091-0

Denison Sandwich.indd, dd

B59 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZRV

General Description
Series ZRV direct operated check valves have a car-
tridge type insert to provide zero leakage and high life
time.
The check function can be located in the P-port or in
the T-port.
B
ZRV-P02 ZRV-P02

Features
• Leakage-free seat.
• High life time.
• Cracking pressure 0.5 Bar (7.25 PSI).
• Sizes:
– ZRV01 – NFPA D03 / NG6 / CETOP 3
– ZRV02 – NFPA D05 / NG10 / CETOP 5

ZRV-P02

Ordering Information

ZRV
Direct Operated Port Size
Check Valve Option

Code Description Code Description


P Blocked in P 01 NFPA D03 / NG6
T Blocked in T 02 NFPA D05 / NG10

Weight:
ZRV*01 0.7 kg (1.5 lbs)
ZRV*02 2.0 kg (4.4 lbs.)

ZRV01 ZRV02

Denison Sandwich.indd, dd

B60 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZRV

Specifications
General
Size NG6 NG10
DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
Mounting Interface
NFPA D03 NFPA D05

Mounting Position Unrestricted


CETOP RP 121 CETOP RP 121 5
B
Ambient Temprature -20°C to +50°C (-4°F to +122°F)
Hydraulic
Max. Operating Pressure 350 Bar (5075 PSI)
Nominal Flow 40 LPM (10.6 GPM) 100 LPM (26.5 GPM)
Cracking Pressure 0.5 Bar (7.25 PSI) 0.5 Bar (7.25 PSI)
Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20°C to +80°C (-4°F to +176°F)
Viscosity
Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
    Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)

p/Q Performance Curves


ZRV P/T01 ZRV P/T02

Denison Sandwich.indd, dd

B61 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series ZRV

ZRV01 – Inch equivalents for millimeter dimensions are shown in (**)

ZRV02 – Inch equivalents for millimeter dimensions are shown in (**)

Denison Sandwich.indd, dd

B62 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Installation Information Series CM, CPOM, FM, PRDM, PRM, RM, Z**

CAUTION: System Cleanliness


Sandwich Installation Any hydraulic system that includes Parker valves
Prior to installation of Sandwich valves, please review should be carefully protected against dirt and fluid
flow paths. Due to the reversibility of the DO3 size, in- contamination. Life of the valves, as well as of all other
correct installation will alter the hydraulic circuit. Care components, will be greatly lengthened. Operation will
must be taken during installation to insure that the be smoother and more precise. Maintenance and re-
Sandwich is installed in compliance with the hydraulic
schematic. Please consult with your Parker represen-
pairs will be reduced. Lost production because of low
pressure and flow will be minimized. Fluid contamina- B
tative with any questions that may arise. tion should be maintained to less than 500 particles
larger than 10 micrometers per milliliter of fluid (SAE
class 4 or better/ISO Code 16/13).

Hydraulic Fluids
Parker recommends using top-quality hydraulic
fluids having a viscosity range of 32 to 54 cSt
(150 to 250 SSU) at 38°C (100°F). The absolute
Pressure Ratings viscosity range should be 16 to 220 cSt (80 to 1000
Unless otherwise specified, all Parker Sandwich SSU). Fluids should have highest anti-wear character-
valves have continuous duty pressure rating as shown istics and be treated to avoid rust and oxidation.
in this catalog.
Seals
Special Requirements When used with water-glycol, water/oil emulsions, and
Consult your Parker representative for factory recom- high-grade petroleum base hydraulic fluids, Parker
mendations on such situations as: standard nitrile seals are suitable.
When using phosphate ester fluids or their blends,
• Installations that will operate at pressures higher than specify Parker optional seals made of fluorocarbon.
published catalog ratings.
Synthetic fire-resistant fluids require special seal ma-
• Use of hydraulic fluids which do not meet our recom- terials which your Parker representative can recom-
mended specifications. mend.

• Operations where fluid temperature will exceed 121°C Torque Specifications


(250°F).
The recommended torque valves are for the bolts
Recommended Mounting Surface which mount the valve to the manifold or subplate are
as follows:
Surface must be flat within .0004 inch T.I.R. and
smooth with 32 micro-inch. Size Torque Valve
D03 5.7 N.m. (50 in.-lbs.)
D05 16.3 N.m. (12 ft.-lbs.)
D07 63.0 N.m. (46.5 ft.-lbs.)
D08 108.5 N.m. (80 ft.-lbs.)

Denison Sandwich.indd, dd

B63 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Installation Information Series CM, CPOM, FM, PRDM, PRM, RM, Z**

Mounting Pattern – NFPA D03, CETOP 3 & NG6


Inch equivalents for millimeter dimensions are shown in (**)

51.00
(2.000) M5-0.8 (10-24) UNC-2B thread
min. x 10.40 (.410) min. thread depth
40.50
(1.594) 4-holes
0.28
33.00 S A B

B
(1.300) (0.011)

30.20
5.10 (1.190)
(0.200)
21.50
(0.850)
0.75
(0.030) B
O 7.5 (.295) max.
A P.A.B. & T ports
T 0.56
15.50 (0.022)
L A B
31.00 (0.610)
43.00 (1.220)
(1.70) A
min.
25.90
(1.020) O 3.86/4.27 (.152/.168)
31.75 B x 4.00 (.160) min. depth
(1.250)
0.28
(0.011) S A B
P

12.70
(0.500)
4.80 (0.190) R. max. typ.
4 places

Mounting Pattern – NFPA D05, CETOP 5 & NG10


Inch equivalents for millimeter dimensions are shown in (**)

91.2
(3.62)
-B-
54.0
(2.13)
50.8
(2.00)
37.3
(1.47)
27.0
(1.06) 16.7
(0.66)
21.4 6.4 3.2
(0.84) (0.25) (0.13)

O 11.2 (0.441) max.


-A-
P.A.B. & T ports
0.56
P (0.022)
L A B
32.5
(1.28)
75.0 46.0
(2.95) (1.81) A B
¼ – 20 UNC – 2B (M6 x 1) th'd
x 9.7 (0.38) min. th'd depth
T T 4 places
0.28
(0.011) S A B

Denison Sandwich.indd, dd

B64 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Installation Information Series CM, CPOM, FM, PRDM, PRM, RM, Z**

Mounting Pattern – NFPA D07, CETOP 7 & NG16


Inch equivalents for millimeter dimensions are shown in (**)

Mounting Pattern – NFPA D08, CETOP 8 & NG25


Inch equivalents for millimeter dimensions are shown in (**)

152.4
(6.00)

-B-
130.2
(5.13) 112.7
(4.44)
100.8
(3.97) 94.5
(3.72)
½ – 13 UNC – 2B x 22.22 min th'd dp.
77.0 (M12) (0.875)
(3.03) 53.2 6 holes
(2.09)
29.4 0.28
17.5 4.8 (1.16) A B
17.5 (0.011) S
(0.69) (0.19)
(0.69)

-A- O 11.2 (0.441) max.


3 holes
0.56
(0.022)
L A B
74.6 73.0
130.0 92.1 (2.94) (2.88)
(3.63) O 23.42 (0.922) max.
(5.12)
4 holes
0.56
(0.022)
L A B

O 0.288 / 272 x 0.31 min dp.


(7.32 / 6.91) (8)
2 holes
0.28
(0.011)
L A B

Denison Sandwich.indd, dd

B65 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZDR

General Description
Series ZDR pilot operated pressure reducing valves
are designed for maximum flow rates.

The reducing function can be located in the ports P, A


or B. The sizes NG06 and NG10 are equipped with an

B integral return flow check valve (reducing function in A


or B).
ZDR-P01 ZDR-B01

Features
• High flow capacity.
• Sizes::
– ZDR01 – NFPA D03 / NG6 / CETOP 3
– ZDR02 – NFPA D05 / NG10 / CETOP 5

• With integral return flow check valve.


ZDR-B02

Specifications
General
Size NG6 NG10
Mounting Interface DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05
CETOP RP 121 CETOP RP 121
Mounting Position Unrestricted
Ambient Temperature Range -20°C to +50°C (-4°F to +122°F)
Hydraulic
Maximum Operating Pressure up to 350 Bar (5075 PSI); ZDR-AR / BR up to 315 Bar (4568 PSI)

Nominal Flow 80 LPM (21.2 GPM) 120 LPM (31.7 GPM)


Pilot Oil 0.2 LPM (0.1 GPM) 0.3 LPM (0.1 GPM)
Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20°C to +80°C (-4°F to +176°F)
Viscosity   Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)

Denison Sandwich.indd, dd

B42 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZDR

Ordering Information
ZDR S0 D
Pressure Port Size Pressure Hexagon Screw Design Seal
Reducing Option Range with Lock Nut Series
Valve

B
Code Description Code Description Code Description
01 NFPA D03 / NG6 1 up to 100 Bar (1450 PSI) 1 Nitrile
02 NFPA D05 / NG10 5* up to 350 Bar (5075 PSI) 5 Fluorocarbon

* AR/BR 325 Bar (4568 PSI)


Code Size Description
P 01/02 Pressure reducing in P
with pressure gauge port M
AR 01/02 Pressure reducing in A
with check valve
Weight: ZDR-P ZDR-AR/BR
BR 01/02 Pressure reducing in B
ZDR*01 1.6 kg (3.5 lbs.) 1.8 kg (4.0 lbs.)
with check valve
ZDR*02 2.9 kg (6.4 lbs.) 3.0 kg (6.6 lbs.)

ZDR01 ZDR02

Performance Curves
ZDR-P/AR/BR01 ZDR-P/AR/BR02

Denison Sandwich.indd, dd

B43 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series ZDR

ZDR01 – Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code
1 098-91184-0
5 098-91185-0
Complete Cartridge
Seal Order Code
1 098-91102-0
5 098-91103-0

ZDR02 – Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code
1 098-91182-0
5 098-91183-0
Complete Cartridge
Seal Order Code
1 098-91102-0
5 098-91103-0

Denison Sandwich.indd, dd

B44 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZDV

General Description
Series ZDV pilot operated pressure relief valves are
designed for maximum flow rates.
The relief function can be located between P and T,
A and T, B and T or A and T + B and T for typical pres-
sure relief functions.
For a pre-charge function the ZDV can be ordered with B
pressure function between A and B + B and A. ZDV-P01 ZDV-B01

Features
• High flow capacity.
• Pressure function in P, A, B or A + B.
• Sizes:
– ZDV01 – NFPA D03 / NG6 / CETOP 3
– ZDV02 – NFPA D05 / NG10 / CETOP 5
ZDV-B02

Ordering Information

ZDV S0 D
Pressure Port Size Pressure Hexagon Screw Design Seal
Relief Option Range with Lock Nut Series
Valve

Code Description Code Description Code Description


01 NFPA D03 / NG6 1 up to 70 Bar (1015 PSI) 1 Nitrile
02 NFPA D05 / NG10 5* up to 350 Bar (5075 PSI) 5 Fluorocarbon

* ABS 315 Bar (4568 PSI)


Code Size Description
P 01/02 P–T
A 01/02 A–T
B 01/02 B–T
AB 01/02 A–T&B–T Weight: One Cartridge Two Cartridges
ABS 01/02 A–B&B–A ZDV*01 1.6 kg (3.5 lbs.) 2.5 kg (5.5 lbs.)
ZDV*02 3.0 kg (6.6 lbs.) 3.7 kg (8.2 lbs.)

Denison Sandwich.indd, dd

B45 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZDV

Ordering Information
ZDV01

ZDV02

Specifications
General
Size NG6 NG10
Mounting DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05
CETOP RP 121 CETOP RP 121
Mounting Position Unrestricted
Ambient Temperature Range -20° to +50°C (-4°F to +122°F)
Hydraulic
Maximum Operating Pressure up to 350 Bar (5075 PSI); ZDV*ABS up to 315 Bar (4568 PSI)

Nominal Flow 80 LPM (21.2 GPM) 140 LPM (37.0 GPM)


Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20° to +80°C (-4°F to +176°F)
Viscosity Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Denison Sandwich.indd, dd

B46 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Performance Curves Series ZDV

ZDV-P/A/B/ABS01 ZDV-AB01

ZDV-P/A/B/AB02 ZDV-ASB02

Denison Sandwich.indd, dd

B47 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series ZDV

ZDV01 – Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code
1 098-91182-0
5 098-91183-0
Complete Cartridge
Seal Order Code
1 098-91116-0
5 098-91117-0

ZDV02 – Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code
1 098-91076-0
5 098-91077-0
Complete Cartridge
Seal Order Code
1 098-91116-0
5 098-91117-0

Denison Sandwich.indd, dd

B48 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZNS

General Description
Series ZNS counterbalance valve controls the actuator
movement at overrunning loads.
The return flow from the actuator is piloted and con-
trolled by the inlet flow to the actuator, ensuring a
cavitation-free lowering of the load.
The counterbalance valve operates as a pressure relief B
valve. The setting pressure is lowered by the pressure ZNS-AB01 ZNS-B01
in the inlet line. To ensure safe load holding the setting
pressure should be approximately 30% higher than the
max. load pressure.

Features
• Controlled movement loads.
• Load holding via leak-free poppet valve.
• Secondary relief protection for the actuator.
• Sizes:
ZNS-B01
ZNS*01 – NFPA D03 / NG6 / CETOP 3
ZNS*02 – NFPA D05 / NG10 / CETOP 5

Ordering Information
ZNS S0 D
Counterbalance Port Size Pressure Hexagon Screw Design Seal
Valve Option Range with Lock Nut Series

Code Description Code Description Code Description Code Description


A in A 01 NFPA D03 / NG6 2 70 to 175 Bar (1015 to 2538 PSI) 1 Nitrile
B in B 02 NFPA D05 / NG10 5 1) 140 to 350 Bar (2030 to 5075 PSI) 5 Fluorocarbon
AB in A and B 1)
ZNS02 to 315 Bar (4568 PSI)

Weight: 1 cartridge 2 cartridges


ZNS*01 1.3 kg (2.9 lbs.) 3.0 kg (6.6 lbs.)
ZNS*02 1.6 kg (3.5 lbs.) 3.9 kg (8.6 lbs.)

ZNS01 ZNS02

Denison Sandwich.indd, dd

B49 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Specifications Series ZNS

Specifications
General
Size NG6 NG10
Mounting Interface DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
NFPA D03 NFPA D05

B Mounting Position Unrestricted


Ambient Temperature Range -20°C to +50°C (-4°F to +122°F)
Hydraulic
Maximum Operating Pressure 350 Bar (5075 PSI) 315 Bar (4568 PSI)

Pressure Range 175 Bar (2538 PSI), 350 Bar (5075 PSI)
Pilot Ratio 4.5 : 1
Leakage On request
Nominal Flow 60 LPM (15.9 GPM) 120 LPM (31.7 GPM)
Opening Pressure 0.3 LPM (0.1 GPM) 0.3 LPM (0.1 GPM)
Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20°C to +80°C (-4°F to +176°F)
Viscosity Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO Class 4406 (1999) 18/16/13 (acc. NAS 1638: 7)

Denison Sandwich.indd, dd

B50 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Performance Curves Series ZNS

ZNS01

ZNS02

All characteristic curves measured with HLP46 at 50°C (122°F).

Denison Sandwich.indd, dd

B51 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series ZNS

ZNS01 – Inch equivalents for millimeter dimensions are shown in (**)

B
Seal Kit
Seal Order Code
1 098-91153-0
5 098-91154-0
Complete Cartridge
Seal Order Code
1 517-01017-2
5 517-00448-8

ZNS02 – Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code
1 098-91155-0
5 098-91183-0
Complete Cartridge
Seal Order Code
1 517-00449-8
5 517-00450-8

Denison Sandwich.indd, dd

B52 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZRD

General Description
Series ZRD throttle check valves are designed for
maximum flow rates.
The throttle check function can be located in port A or
B as well as in A + B. Meter-in or meter-out functional-
ity can be selected by model code.
A low flow / high resolution version in NFPA 03 / NG6 B
for sensitive shifting time adjustment of pilot operated ZRD-ABZ01 ZRD-AA02
directional control valves is available on request.

Features
• High flow capacity.
• Various functional arrangements.
• Sizes:
– ZRD01 – NFPA D03 / NG6 / CETOP 3
– ZRD02 – NFPA D05 / NG10 / CETOP 5
ZRD-AA02
Ordering Information
ZRD S0 D
Throttle Valve Meter Size Hexagon Design Seal
with Check Option Screw with Series
Lock Nut
Code Description Code Description
AA Meter-out 1 Nitrile
Code Description
Control in A 5 Fluorocarbon
01 NFPA D03 / NG6
AZ Meter-in
Control in A 02 NFPA D05 / NG10
BA Meter-out
Control in B
BZ Meter-in
Control in B
ABA Meter-out
Control in A and B Weight: 1 Cartridge 2 Cartridges
ABZ Meter-in ZRD*01 1.2 kg (2.6 lbs) 1.3 kg (2.9 lbs)
Control in A and B ZRD*02 2.8 kg (6.2 lbs.) 2.9 kg (6.4 lbs.)

ZRD01

ZRD02
(continued on
next page)
Denison Sandwich.indd, dd

B53 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Ordering Information Series ZRD

Ordering Information
ZRD02

Specifications
General
Size NG6 NG10
DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
Mounting
NFPA D03 NFPA D05
CETOP RP 121 CETOP RP 121 5
Mounting Position Unrestricted
Ambient Temprature -20°C to +50°C (-4°F to +122°F)
Hydraulic
Max. Operating Pressure 350 Bar (5075 PSI)
Nominal Flow 80 LPM (21.2 GPM) 160 LPM (42.3 GPM)
Leakage — —
Cracking Pressure — —
Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20°C to +80°C (-4°F to +176°F)
Viscosity
  Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
 Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)

Denison Sandwich.indd, dd

B54 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Performance Curves Series ZRD

p/Q Performance Curves


ZRD01

ZRD02

* Throttle closed
Fluid Viscosity 30 cSt @ 50°C (122°F)

Denison Sandwich.indd, dd

B55 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series ZRD

ZRD01
Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code

B
1 098-91096-0
5 098-91097-0
Complete Cartridge
Order Code
098-91119-0
O-ring Plate
Order Code
S26-27553-0

ZRD02
Inch equivalents for millimeter dimensions are shown in (**)
Seal Kit
Seal Order Code
1 098-91098-0
5 098-91099-0
Complete Cartridge
Order Code
098-91120-0
O-ring Plate
Order Code
S16-85742-0

Denison Sandwich.indd, dd

B56 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZRE

General Description.
Series ZRE pilot operated check valves are designed
for maximum flow rates and long life time.
The valves are typically used in combination with spool
type directional control valves to ensure leak free posi-
tioning of the actuator.
The inlet flow is free while the outlet flow is blocked. B
Pressure in the inlet line opens the check valve and ZRE-B01 ZRE-A02
allows free outlet flow.

Features
• High life time.
• Check function in A, B or A + B.
• Sizes:
– ZRE01 – NFPA D03 / NG6 / CETOP 3
– ZRE02 – NFPA D05 / NG10 / CETOP 5

ZRE-A02
Ordering Information

ZRE
Pilot Operated Port Size Design Seal
Check Valve Option Series

Code Description Code Description Code Description Code Description


A Blocked in A 01 NFPA D03 / NG6 D Size 01 1 Nitrile
B Blocked in B 02 NFPA D05 / NG10 E Size 02 5 Fluorocarbon
AB Blocked in A
and B Weight:
ZRE*01 1.2 kg (2.6 lbs)
ZRE*02 3.1 kg (6.8 lbs.)
ZRE01

ZRE02

Denison Sandwich.indd, dd

B57 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZRE

Specifications
General
Size NG6 NG10
DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
Mounting Interface
NFPA D03 NFPA D05
B Mounting Position Unrestricted
CETOP RP 121 CETOP RP 121 5

Ambient Temprature -20°C to +50°C (-4°F to +122°F)


Hydraulic
Max. Operating Pressure 350 Bar (5075 PSI)
Nominal Flow 60 LPM (15.9 GPM) 120 LPM (31.7 GPM)
Opening Ratio
1:6 1:6
(Pilot Cone/Main Cone)
Cracking Pressure 1.2 Bar (17.4 PSI) 2.0 Bar (29.0 PSI)
Fluid Hydraulic oil in accordance with DIN 51524 ... 51525
Fluid Temperature -20°C to +80°C (-4°F to +176°F)
Viscosity
 Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
 Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)

Performance Curves
p/Q
ZRE01 ZRE02

Fluid Viscosity 30 cSt at 50°C (122°F).

Denison Sandwich.indd, dd

B58 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series ZRE

ZRE01
Inch equivalents for millimeter dimensions are shown in (**)

Seal
Seal Kit
Order Code
B
1 098-91088-0
5 098-91089-0

ZRE02
Inch equivalents for millimeter dimensions are shown in (**)

Seal Kit
Seal Order Code
1 098-91090-0
5 098-91091-0

Denison Sandwich.indd, dd

B59 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZRV

General Description
Series ZRV direct operated check valves have a car-
tridge type insert to provide zero leakage and high life
time.
The check function can be located in the P-port or in
the T-port.
B
ZRV-P02 ZRV-P02

Features
• Leakage-free seat.
• High life time.
• Cracking pressure 0.5 Bar (7.25 PSI).
• Sizes:
– ZRV01 – NFPA D03 / NG6 / CETOP 3
– ZRV02 – NFPA D05 / NG10 / CETOP 5

ZRV-P02

Ordering Information

ZRV
Direct Operated Port Size
Check Valve Option

Code Description Code Description


P Blocked in P 01 NFPA D03 / NG6
T Blocked in T 02 NFPA D05 / NG10

Weight:
ZRV*01 0.7 kg (1.5 lbs)
ZRV*02 2.0 kg (4.4 lbs.)

ZRV01 ZRV02

Denison Sandwich.indd, dd

B60 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Technical Information Series ZRV

Specifications
General
Size NG6 NG10
DIN 24340 A6 DIN 24340 A10
ISO 4401 ISO 4401
Mounting Interface
NFPA D03 NFPA D05

Mounting Position Unrestricted


CETOP RP 121 CETOP RP 121 5
B
Ambient Temprature -20°C to +50°C (-4°F to +122°F)
Hydraulic
Max. Operating Pressure 350 Bar (5075 PSI)
Nominal Flow 40 LPM (10.6 GPM) 100 LPM (26.5 GPM)
Cracking Pressure 0.5 Bar (7.25 PSI) 0.5 Bar (7.25 PSI)
Fluid Hydraulic oil as per DIN 51524 ... 51525
Fluid Temperature -20°C to +80°C (-4°F to +176°F)
Viscosity
Permitted 10 to 650 cSt / mm2/s (46 to 3013 SSU)
    Recommended 30 cSt / mm2/s (139 SSU)
Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)

p/Q Performance Curves


ZRV P/T01 ZRV P/T02

Denison Sandwich.indd, dd

B61 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Dimensions Series ZRV

ZRV01 – Inch equivalents for millimeter dimensions are shown in (**)

ZRV02 – Inch equivalents for millimeter dimensions are shown in (**)

Denison Sandwich.indd, dd

B62 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Installation Information Series CM, CPOM, FM, PRDM, PRM, RM, Z**

CAUTION: System Cleanliness


Sandwich Installation Any hydraulic system that includes Parker valves
Prior to installation of Sandwich valves, please review should be carefully protected against dirt and fluid
flow paths. Due to the reversibility of the DO3 size, in- contamination. Life of the valves, as well as of all other
correct installation will alter the hydraulic circuit. Care components, will be greatly lengthened. Operation will
must be taken during installation to insure that the be smoother and more precise. Maintenance and re-
Sandwich is installed in compliance with the hydraulic
schematic. Please consult with your Parker represen-
pairs will be reduced. Lost production because of low
pressure and flow will be minimized. Fluid contamina- B
tative with any questions that may arise. tion should be maintained to less than 500 particles
larger than 10 micrometers per milliliter of fluid (SAE
class 4 or better/ISO Code 16/13).

Hydraulic Fluids
Parker recommends using top-quality hydraulic
fluids having a viscosity range of 32 to 54 cSt
(150 to 250 SSU) at 38°C (100°F). The absolute
Pressure Ratings viscosity range should be 16 to 220 cSt (80 to 1000
Unless otherwise specified, all Parker Sandwich SSU). Fluids should have highest anti-wear character-
valves have continuous duty pressure rating as shown istics and be treated to avoid rust and oxidation.
in this catalog.
Seals
Special Requirements When used with water-glycol, water/oil emulsions, and
Consult your Parker representative for factory recom- high-grade petroleum base hydraulic fluids, Parker
mendations on such situations as: standard nitrile seals are suitable.
When using phosphate ester fluids or their blends,
• Installations that will operate at pressures higher than specify Parker optional seals made of fluorocarbon.
published catalog ratings.
Synthetic fire-resistant fluids require special seal ma-
• Use of hydraulic fluids which do not meet our recom- terials which your Parker representative can recom-
mended specifications. mend.

• Operations where fluid temperature will exceed 121°C Torque Specifications


(250°F).
The recommended torque valves are for the bolts
Recommended Mounting Surface which mount the valve to the manifold or subplate are
as follows:
Surface must be flat within .0004 inch T.I.R. and
smooth with 32 micro-inch. Size Torque Valve
D03 5.7 N.m. (50 in.-lbs.)
D05 16.3 N.m. (12 ft.-lbs.)
D07 63.0 N.m. (46.5 ft.-lbs.)
D08 108.5 N.m. (80 ft.-lbs.)

Denison Sandwich.indd, dd

B63 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Installation Information Series CM, CPOM, FM, PRDM, PRM, RM, Z**

Mounting Pattern – NFPA D03, CETOP 3 & NG6


Inch equivalents for millimeter dimensions are shown in (**)

51.00
(2.000) M5-0.8 (10-24) UNC-2B thread
min. x 10.40 (.410) min. thread depth
40.50
(1.594) 4-holes
0.28
33.00 S A B

B
(1.300) (0.011)

30.20
5.10 (1.190)
(0.200)
21.50
(0.850)
0.75
(0.030) B
O 7.5 (.295) max.
A P.A.B. & T ports
T 0.56
15.50 (0.022)
L A B
31.00 (0.610)
43.00 (1.220)
(1.70) A
min.
25.90
(1.020) O 3.86/4.27 (.152/.168)
31.75 B x 4.00 (.160) min. depth
(1.250)
0.28
(0.011) S A B
P

12.70
(0.500)
4.80 (0.190) R. max. typ.
4 places

Mounting Pattern – NFPA D05, CETOP 5 & NG10


Inch equivalents for millimeter dimensions are shown in (**)

91.2
(3.62)
-B-
54.0
(2.13)
50.8
(2.00)
37.3
(1.47)
27.0
(1.06) 16.7
(0.66)
21.4 6.4 3.2
(0.84) (0.25) (0.13)

O 11.2 (0.441) max.


-A-
P.A.B. & T ports
0.56
P (0.022)
L A B
32.5
(1.28)
75.0 46.0
(2.95) (1.81) A B
¼ – 20 UNC – 2B (M6 x 1) th'd
x 9.7 (0.38) min. th'd depth
T T 4 places
0.28
(0.011) S A B

Denison Sandwich.indd, dd

B64 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog HY14-2500/US Sandwich Valves
Installation Information Series CM, CPOM, FM, PRDM, PRM, RM, Z**

Mounting Pattern – NFPA D07, CETOP 7 & NG16


Inch equivalents for millimeter dimensions are shown in (**)

Mounting Pattern – NFPA D08, CETOP 8 & NG25


Inch equivalents for millimeter dimensions are shown in (**)

152.4
(6.00)

-B-
130.2
(5.13) 112.7
(4.44)
100.8
(3.97) 94.5
(3.72)
½ – 13 UNC – 2B x 22.22 min th'd dp.
77.0 (M12) (0.875)
(3.03) 53.2 6 holes
(2.09)
29.4 0.28
17.5 4.8 (1.16) A B
17.5 (0.011) S
(0.69) (0.19)
(0.69)

-A- O 11.2 (0.441) max.


3 holes
0.56
(0.022)
L A B
74.6 73.0
130.0 92.1 (2.94) (2.88)
(3.63) O 23.42 (0.922) max.
(5.12)
4 holes
0.56
(0.022)
L A B

O 0.288 / 272 x 0.31 min dp.


(7.32 / 6.91) (8)
2 holes
0.28
(0.011)
L A B

Denison Sandwich.indd, dd

B65 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA

You might also like