Professional Documents
Culture Documents
PROJECT TITLE:
TEST PILE/
FOUNDATION
CONSTRUCTION OF RAILWAY OVERBRIDGE AT Pile Type: Date: 2/3/2018
CONSULTANTS LTD.
SERVICE PILE
JURAIN.
PILE DATA
2
Pile diameter, B = 1.20 m Pile Base Area, A b = 1.131 m Length of Test Pile-03 [Near Pier 11] = 35 m
Borehole Level = +6.1 RL.m Perimeter = 3.770 m Desired Ultimate Capacity of Pile = 6000 kN
Cut-off Level of Pile = +4.1 m Ignored top friction = 2.00 m Attained Ultimate Capacity at Static Load
4500.00 kN
Ignored bottom friction = 1.00 m Test =
ADOPTED DESIGN PARAMETERS
GWT: +6.1 RL.m Max. ultimate end bearing(Limiting Value) = 4.0 ksf (191.52 kPa) Co-efficient for Skin Friction = 0.48
γw: 3
9.8 kN/m Depth of Liquefiable Strata Considered = 0 m Co-efficient for End Bearing= 0.2
DESIGN SUMMARY
Pile Head Level = +4.1 RL.m Pile Toe Level = -42.90 RL.m Pile Compression Capacity = 5990.25 kN
Total Length = 47.05 m G.W.T = 0.00 m Pile Tension Capacity = N/A kN
Resistance, qpr
Allowable Safe
Allowable Skin
Resistance, fs
Pile Capacity,
Allowable Tip
Ultimate Skin
Ultimate Pile
Ultimate Tip
Eff. Vertical
Resistance
Resistance
Resistance
Resistance
Sandy (S)/
Thickness
Depth (R.L m)
Clayey(C)
Field SPT
Capacity,
Qu Ultimate
Unit Skin
Qp Ultimate
Factored
Factored
Unit Tip
Qu safe
Stress
Layer
Layer
Depth
of Mid
(R.L m)
(R.L m)
Start
End
# (m) (m) Type (kPa) N (kPa) (kN) (kPa) (kN) (kN) (kN) (kN) (kN)
1 +6.1 4.15 1.95 0.975 S 7.02 7 5.5 0.0 536.7 0.0 0.0 0.0 0.0 0.0
2 4.15 2.65 1.5 2.7 S 19.44 8 15.2 0.0 613.3 0.0 0.0 0.0 0.0 0.0
3 2.65 1.15 1.5 4.2 S 30.24 7 18.8 88.8 536.7 607.0 695.7 48.6 121.4 170.0
4 1.15 -0.35 1.5 5.7 S 41.04 10 33.5 246.7 766.7 867.1 1113.8 135.2 173.4 308.6
5 -0.35 -1.85 1.5 7.2 S 51.84 7 27.3 375.4 536.7 607.0 982.3 205.7 121.4 327.1
6 -1.85 -3.35 1.5 8.7 C 62.64 16 77.9 742.6 0.0 0.0 742.6 406.9 0.0 406.9
7 -3.35 -3.90 0.55 9.725 C 70.02 16 77.9 877.2 0.0 0.0 877.2 480.7 0.0 480.7
8 -3.90 -4.85 0.95 10.475 C 75.42 29 126.7 1255.3 0.0 0.0 1255.3 687.9 0.0 687.9
9 -4.85 -6.35 1.5 11.7 C 84.24 39 146.3 1944.9 0.0 0.0 1944.9 1065.8 0.0 1065.8
10 -6.35 -7.85 1.5 13.2 C 95.04 33 144.3 2624.9 0.0 0.0 2624.9 1438.5 0.0 1438.5
11 -7.85 -9.35 1.5 14.7 C 105.84 55 187.1 3506.5 0.0 0.0 3506.5 1921.5 0.0 1921.5
12 -9.35 -10.85 1.5 16.2 S 116.64 59 60.6 3792.2 2900.0 3279.8 7072.1 2078.2 656.0 2734.1
13 -10.85 -12.35 1.5 17.7 S 127.44 78 60.6 4077.9 2900.0 3279.8 7357.7 2234.7 656.0 2890.6
14 -12.35 -13.85 1.5 19.2 S 138.24 100 59.9 4360.0 2900.0 3279.8 7639.8 2389.3 656.0 3045.2
15 -13.85 -15.35 1.5 20.7 S 149.04 94 58.4 4635.4 2900.0 3279.8 7915.2 2540.2 656.0 3196.2
16 -15.35 -16.85 1.5 22.2 S 159.84 86 56.4 4901.1 2900.0 3279.8 8180.9 2685.8 656.0 3341.8
17 -16.85 -18.35 1.5 23.7 S 170.64 61 53.7 5154.1 2900.0 3279.8 8433.9 2824.4 656.0 3480.4
18 -18.35 -19.85 1.5 25.2 S 181.44 53 50.4 5391.5 2900.0 3279.8 8671.3 2954.5 656.0 3610.5
19 -19.85 -21.35 1.5 26.7 S 192.24 62 46.5 5610.5 2900.0 3279.8 8890.3 3074.6 656.0 3730.5
20 -21.35 -22.85 1.5 28.2 S 203.04 63 42.0 5808.5 2900.0 3279.8 9088.4 3183.1 656.0 3839.0
21 -22.85 -24.35 1.5 29.7 S 213.84 69 40.6 6000.0 2900.0 3279.8 9279.8 3288.0 656.0 3944.0
22 -24.35 -25.85 1.5 31.2 S 224.64 78 42.7 6201.1 2900.0 3279.8 9480.9 3398.2 656.0 4054.2
23 -25.85 -27.35 1.5 32.7 S 235.44 74 44.7 6411.9 2900.0 3279.8 9691.8 3513.7 656.0 4169.7
24 -27.35 -28.90 1.55 34.225 S 246.42 91 46.8 6639.9 2900.0 3279.8 9919.7 3638.7 656.0 4294.6
25 -28.90 -30.35 1.45 35.725 S 257.22 38 48.9 6862.5 2900.0 3279.8 10142.4 3760.7 656.0 4416.6
26 -30.35 -31.85 1.5 37.2 S 267.84 44 50.9 7102.4 2900.0 3279.8 10382.2 3892.1 656.0 4548.1
27 -31.85 -32.90 1.05 38.475 C 277.02 28 122.3 7505.7 0.0 0.0 7505.7 4113.1 0.0 4113.1
28 -32.90 -33.35 0.45 39.225 C 282.42 28 122.3 7678.6 0.0 0.0 7678.6 4207.9 0.0 4207.9
29 -33.35 -36.35 3 40.95 C 294.84 27 117.9 8789.5 0.0 0.0 8789.5 4816.7 0.0 4816.7
30 -36.35 -42.90 6.55 45.725 S 329.22 27 62.6 10076.7 2070.0 2341.1 12417.8 5522.0 468.2 5990.2
Total Length = 47.05 m
NOTES:
» Sub soil up to depth (10 x diameter of pile) below pile tip consistency and composition shall be compatible and confirmed by test.
» End bearing shall be considered if mud, debris etc. from pile tip is properly cleaned and compatible to in-situ condition.
» Where Factor of Safety against Liquefaction is less than one, skin resistance is ineffective.
» The top 2.0 m of the shaft sides are considered noncontributing due to cyclic lateral movements that separate the shaft from the soil as well as potential desiccation
separation of the surficial soil. Additionally, the bottom 1D of the shaft side shear is disregarded to account for lateral stresses that develop radially as the end bearing
mobilizes.