You are on page 1of 1

EVALUATION OF GEOTECHNICAL Location:

NEAR Analysed PRIODEEP


PIER# 11 By: CHOWDHURY
CAPACITY OF BORED R.C.C PILE BASED
ON STATIC LOAD TEST RESULTS & SUBSOIL Checked
Borehole: BH-03
PARAMETERS. By:

PROJECT TITLE:
TEST PILE/
FOUNDATION
CONSTRUCTION OF RAILWAY OVERBRIDGE AT Pile Type:
SERVICE PILE
Date: 2/3/2018
CONSULTANTS LTD.
JURAIN.

PILE DATA
Pile diameter, B = 1.20 m Pile Base Area, A b = 1.131 m2 Length of Test Pile-03 [Near Pier 11] = 35 m
Borehole Level = +6.1 RL.m Perimeter = 3.770 m Desired Ultimate Capacity of Pile = 6000 kN
Cut-off Level of Pile = +4.1 m Ignored top friction = 2.00 m Attained Ultimate Capacity at Static Load
4500.00 kN
Ignored bottom friction = 1.00 m Test =
ADOPTED DESIGN PARAMETERS
GWT: +6.1 RL.m Max. ultimate end bearing(Limiting Value) = 4.0 ksf (191.52 kPa) Co-efficient for Skin Friction = 0.48
γw: 3
9.8 kN/m Depth of Liquefiable Strata Considered = 0 m Co-efficient for End Bearing= 0.2

DESIGN SUMMARY
Pile Head Level = +4.1 RL.m Pile Toe Level = -42.90 RL.m Pile Compression Capacity = 5990.25 kN
Total Length = 27.00 m G.W.T = 0.00 m Pile Tension Capacity = N/A kN

Allowable Safe
Resistance, qpr

Allowable Skin
Resistance, fs

Pile Capacity,
Allowable Tip
Ultimate Skin

Ultimate Pile
Ultimate Tip
Eff. Vertical

Resistance

Resistance

Resistance

Resistance
Sandy (S)/
Thickness

Depth (R.L m)
Clayey(C)

Field SPT

Capacity,
Unit Skin

Qp Ultimate

Qu Ultimate

Factored

Factored
Unit Tip
Stress

Qu safe
Layer

Layer

Depth
of Mid
(R.L m)

(R.L m)
Start

End

# (m) (m) Type (kPa) N (kPa) (kN) (kPa) (kN) (kN) (kN) (kN) (kN)
1 +6.1 4.15 1.95 0.975 S 7.02 7 5.5 0.0 536.7 0.0 0.0 0.0 0.0 0.0
2 4.15 2.65 1.5 2.7 S 19.44 8 15.2 0.0 613.3 0.0 0.0 0.0 0.0 0.0
3 2.65 1.15 1.5 4.2 S 30.24 7 18.8 88.8 536.7 607.0 695.7 48.6 121.4 170.0
4 1.15 -0.35 1.5 5.7 S 41.04 10 33.5 246.7 766.7 867.1 1113.8 135.2 173.4 308.6
5 -0.35 -1.85 1.5 7.2 S 51.84 7 27.3 375.4 536.7 607.0 982.3 205.7 121.4 327.1
6 -1.85 -3.35 1.5 8.7 C 62.64 16 77.9 742.6 0.0 0.0 742.6 406.9 0.0 406.9
7 -3.35 -3.90 0.55 9.725 C 70.02 16 77.9 877.2 0.0 0.0 877.2 480.7 0.0 480.7
8 -3.90 -4.85 0.95 10.475 C 75.42 29 126.7 1255.3 0.0 0.0 1255.3 687.9 0.0 687.9
9 -4.85 -6.35 1.5 11.7 C 84.24 39 146.3 1944.9 0.0 0.0 1944.9 1065.8 0.0 1065.8
10 -6.35 -7.85 1.5 13.2 C 95.04 33 144.3 2624.9 0.0 0.0 2624.9 1438.5 0.0 1438.5
11 -7.85 -9.35 1.5 14.7 C 105.84 55 187.1 3506.5 0.0 0.0 3506.5 1921.5 0.0 1921.5
12 -9.35 -10.85 1.5 16.2 S 116.64 59 60.6 3792.2 2900.0 3279.8 7072.1 2078.2 656.0 2734.1
13 -10.85 -12.35 1.5 17.7 S 127.44 78 60.6 4077.9 2900.0 3279.8 7357.7 2234.7 656.0 2890.6
14 -12.35 -13.85 1.5 19.2 S 138.24 100 59.9 4360.0 2900.0 3279.8 7639.8 2389.3 656.0 3045.2
15 -13.85 -15.35 1.5 20.7 S 149.04 94 58.4 4635.4 2900.0 3279.8 7915.2 2540.2 656.0 3196.2
16 -15.35 -16.85 1.5 22.2 S 159.84 86 56.4 4901.1 2900.0 3279.8 8180.9 2685.8 656.0 3341.8
17 -16.85 -18.35 1.5 23.7 S 170.64 61 53.7 5154.1 2900.0 3279.8 8433.9 2824.4 656.0 3480.4
18 -18.35 -19.85 1.5 25.2 S 181.44 53 50.4 5391.5 2900.0 3279.8 8671.3 2954.5 656.0 3610.5
19 -19.85 -21.35 1.5 26.7 S 192.24 62 46.5 5610.5 2900.0 3279.8 8890.3 3074.6 656.0 3730.5
20 -21.35 -22.85 1.5 28.2 S 203.04 63 42.0 5808.5 2900.0 3279.8 9088.4 3183.1 656.0 3839.0
Total Length = 27 m
NOTES:
» Sub soil up to depth (10 x diameter of pile) below pile tip consistency and composition shall be compatible and confirmed by test.
» End bearing shall be considered if mud, debris etc. from pile tip is properly cleaned and compatible to in-situ condition.
» Where Factor of Safety against Liquefaction is less than one, skin resistance is ineffective.
» The top 2.0 m of the shaft sides are considered noncontributing due to cyclic lateral movements that separate the shaft from the soil as well as potential
desiccation separation of the surficial soil. Additionally, the bottom 1D of the shaft side shear is disregarded to account for lateral stresses that develop radially as
the end bearing mobilizes.