You are on page 1of 10

Tensar software output

TensarSoil® Version 2.07

Calculations in accordance with: 2-part wedge method - Bautechnik (seismic loading)

Client: BINA MARGA DAN PENGAIRAN KERAWANG


Project: JEMBATAN TARUM BARAT MBRW

Tensar
Structural Systems

TW1 Wall System

This Tensar Software Output which has been prepared by PT Multibangun Rekatama Patria on a confidential basis, to enable the application of Tensar geogrids to be
evaluated. The Tensar Software Output is merely illustrative and is not a detailed design. It is specific to the unique characteristics of the Tensar geogrids which are
referenced within the calculations.

Copyright in this document belongs to Tensar International Limited. It may not be reproduced in whole or in part without the prior written permission of Tensar International.
It must not be disclosed other than for the purpose of evaluating its commercial application for the use of geogrids.

This Tensar Software Output does not form the whole or any part of a contract. Its suitability for any project is the sole responsibility of the user and its professional advisors.
Neither Tensar International Limited nor PT Multibangun Rekatama Patria are responsible for any application of the Tensar Software Output other than in conjunction with
the sale of Tensar.

Tensar is a registered trademark.

Method of The calculation method used to create this Tensar software output is the two-part wedge reinforced soil
analysis retaining wall designmethod as defined originally in Deutsches Institut für Bautechnik Certificate No
Z20.1-102 adapted to take into account facing connectionstrength and serviceability for static loading and
seismic loading.

Reference Date 9 Jun 2015 Page 1 of 10

Design analysis PT Multibangun Rekatama Patria Jakarta


prepared by
Wisma Sejahtera Room 204
Tel: +62 21 5490011 Jalan Letjen S Parman Kav 75
Fax: +62 21 5324322 Jakarta 11410
E-mail: mrpatria@multibangunpatria.com Indonesia
www.multibangunpatria.com
Tensar software output
TensarSoil® Version 2.07

Calculations in accordance with: 2-part wedge method - Bautechnik (seismic loading)

Input data and Section Project: JEMBATAN TARUM BARAT MBRW

1, 15.00 kN/m², LL

6.80

Datum

90° 90°
0.40
5.30

Tensar Structural Systems TW1 Wall System

Seismic loading case All dimensions in metres Scale 1:100

Fill/foundation Soil zone Drained/ c' ϕ' γ bulk


properties
Design soil undrained (kN/m²) (°) (kN/m³)
strength
Reinforced fill Drained 0.0 27.0 18.0
parameters are
constant Retained fill Drained 0.0 27.0 18.0
volume values
Foundation soil Undrained 80.0 0.0 18.0

Seismic Input External mechanisms Internal mechanisms


design data A h = 0.2g k h (ext) = 0.1g k h (int) = 0.25g
g=
acceleration A v = 0.1g k v (ext) = 0.05g k v (int) = 0.135g
due to gravity
Vertical accelerations may act either downwards or upwards

Surcharges No Load acts from x (m) To x (m) Load (kN/m²) Temporary/Permanent


1 1.00 100.56 15 Temporary
x coordinates are measured from the toe of the reinforced fill block.

Reference Date 9 Jun 2015 Page 2 of 10


Tensar software output
TensarSoil® Version 2.07

Calculations in accordance with: 2-part wedge method - Bautechnik (seismic loading)

Water Location Height of water level above datum (m) ru


pressure data
In front of structure No water pressures
Within fill No water pressures NA

Verificaton Mechanism Result Max/Min Critical case OK?


of external
stability Eccentricity e = 0.41 m 0.88 m max Static check only, Max. OT OK
Sliding on base 2.19 1.5 min Static OK
Bearing 2.17 2.0 min Static, A OK

Verification Mechanism OK? Mechanism OK?


of internal
stability Wedge check OK Internal sliding OK
Post-construction strain < 1.0%
(wedges)

Reinforcement Tensar No of Starting Vertical Finishing Coverage fb


layout Geogrid layers level (m) spacing (m) level (m) (%)
Starting and
finishing levels RE520 16 0.60 0.40 6.60 100 0.85
are related to
datum RE520 1 0.20 - - 100 0.85

Further Further information, specifications and bill of System overview


information quantities descriptions for this TensarTechEarth Installation guide
relevent to Retaining Structure are given in the following Case histories
this documents which form part of this Design
Tensar Analysis
Earth
Retention
System The current versions of these documents may be found by following the website link
to "Tensar Documentation" in the Help menu of the TensarSoil® program

For program users who do Tensar International Limited


not have a link to the internet Tel: +44 (1254) 262431
contact your nearest Tensar Fax: +44 (1254) 266867
representative or distributor E-mail: info@tensar.co.uk
Web: www.tensar.co.uk

Reference Date 9 Jun 2015 Page 3 of 10


Tensar software output
TensarSoil® Version 2.07

Calculations in accordance with: 2-part wedge method - Bautechnik (seismic loading)

Detailed calculation results


The following tables provide the detailed results from the design Analysis, including geogrid design data, together with both
external and internal analysis results.

External stability - characteristic (unfactored) calculated forces


Note: negative forces are upwards and to the right

Loading direction Units Vertical Horizontal


Characteristic static force components
Forces in or above reinforced block:
Soil mass kN/m 623.628 0.000
Facing kN/m 29.175 0.000
Dead loads kN/m 0.000 0.000
Live loads kN/m 64.500 0.000
From water pressure on base kN/m 0.000 0.000
From water pressure on face kN/m 0.000 0.000

Forces behind reinforced block:


From soil kN/m 42.948 132.181
From dead loads kN/m 0.000 0.000
From live loads kN/m 10.527 32.397
From water pressure kN/m 0.000 0.000
Additional characteristic static force components due to seismic loading
Forces in or above reinforced block:
Soil mass kN/m 19.553 39.107
Facing kN/m 1.459 2.917
Dead loads kN/m 0.000 0.000
Live loads kN/m 0.000 0.000
From water pressure on base kN/m 0.000 0.000
From water pressure on face kN/m 0.000 0.000

Forces behind reinforced block:


From soil kN/m 5.762 17.735
From dead loads kN/m 0.000 0.000
From live loads kN/m 0.000 0.000
From water pressure kN/m 0.000 0.000

Verification of external stability - sliding


Sliding resistance is verified for Load combination B.
Loads given below are design values (factored).
Calculation Units Static loading Seismic loading

Design horizontal driving force kN/m 164.578 185.519


Design horizontal resisting force kN/m 359.866 345.670
Sliding on base 2.187 1.863

Requirement > 1.50 > 1.125

OK? OK OK

Reference Date 9 Jun 2015 Page 4 of 10


Tensar software output
TensarSoil® Version 2.07

Calculations in accordance with: 2-part wedge method - Bautechnik (seismic loading)

Verification of external stability - bearing resistance check


Calculations carried using Meyerhof load distribution to take into account eccentricity.
Characteristic bearing resistance is calculated using unfactored loads.
Bearing resistance is verified for Load combination A, Load combination A (max overturning) and Load combination B.
Static load case:
Calculation Units Load comb. LCA max Load comb.
A overturning B
Total vertical load on base (unfactored) kN/m 771 731 706
Total horizontal load on base (unfactored) kN/m 165 165 165
Total moment on base (unfactored) kNm/m 246 299 278
Factor Nc 5.142 5.142 5.142
Factor Nq 1.000 1.000 1.000
Factor Nb 0.000 0.000 0.000
Factor ic 0.874 0.868 0.869
Factor iq 0.000 0.000 0.000
Factor iγ 0.000 0.000 0.000
Effective length L' m 4.661 4.482 4.511
Characteristic ultimate bearing capacity kN/m² 359 357 357

Design bearing resistance kN/m 1675 1600 1612


Design applied load kN/m 771 731 706
F (bearing resistance) 2.173 2.189 2.283

Requirement > 2.00 > 2.00 > 2.00

OK? OK OK OK

Seismic load case (vertical acceleration downwards):


Calculation Units Load comb. LCA max Load comb.
A overturning B
Total vertical load on base (unfactored) kN/m 723 723 723
Total horizontal load on base (unfactored) kN/m 192 192 192
Total moment on base (unfactored) kNm/m 416 416 416
Factor Nc 5.142 5.142 5.142
Factor Nq 1.000 1.000 1.000
Factor Nb 0.000 0.000 0.000
Factor ic 0.825 0.825 0.825
Factor iq 0.000 0.000 0.000
Factor iγ 0.000 0.000 0.000
Effective length L' m 4.147 4.147 4.147
Characteristic ultimate bearing capacity kN/m² 339 339 339

Design bearing resistance kN/m 1407 1407 1407


Design applied load kN/m 723 723 723
F (bearing resistance) 1.947 1.947 1.947

Requirement > 1.50 > 1.50 > 1.50

OK? OK OK OK

Reference Date 9 Jun 2015 Page 5 of 10


Tensar software output
TensarSoil® Version 2.07

Calculations in accordance with: 2-part wedge method - Bautechnik (seismic loading)

Seismic load case (vertical acceleration upwards):


Calculation Units Load comb. LCA max Load comb.
A overturning B
Total vertical load on base (unfactored) kN/m 678 678 678
Total horizontal load on base (unfactored) kN/m 186 186 186
Total moment on base (unfactored) kNm/m 355 355 355
Factor Nc 5.142 5.142 5.142
Factor Nq 1.000 1.000 1.000
Factor Nb 0.000 0.000 0.000
Factor ic 0.837 0.837 0.837
Factor iq 0.000 0.000 0.000
Factor iγ 0.000 0.000 0.000
Effective length L' m 4.253 4.253 4.253
Characteristic ultimate bearing capacity kN/m² 344 344 344

Design bearing resistance kN/m 1464 1464 1464


Design applied load kN/m 678 678 678
F (bearing resistance) 2.159 2.159 2.159

Requirement > 1.50 > 1.50 > 1.50

OK? OK OK OK

Verification of external stability - eccentricity


Eccentricity is verified for Load combination A, Load combination A (max overturning), Load combination B , and
serviceability.
Static load case:
Calculation Units Load comb. LCA max Load comb.
A overturning B
Design vertical load on base kN/m 771 731 706
Design moment on base about centreline kNm/m 246 299 278
Eccentricity m 0.319 0.409 0.394
Maximum permitted m 0.883 0.883 0.883
OK? OK OK OK

Verification of external stability - overturning


Safety against overturning about the toe is verified for Load combination B
Seismic load case (vertical acceleration downwards):
Calculation Units Load comb. B
Total overturning moments about toe kNm/m 515
Total restoring moments about toe kNm/m 2013
F (overturning) 3.910

Requirement > 1.50

OK? OK

Reference Date 9 Jun 2015 Page 6 of 10


Tensar software output
TensarSoil® Version 2.07

Calculations in accordance with: 2-part wedge method - Bautechnik (seismic loading)

Verification of external stability - overturning


Safety against overturning about the toe is verified for Load combination B
Seismic load case (vertical acceleration upwards):
Calculation Units Load comb. B
Total overturning moments about toe kNm/m 489
Total restoring moments about toe kNm/m 1931
F (overturning) 3.952

Requirement > 1.50

OK? OK

Geogrid reinforcement design data


Geogrid design strength is calculated using the strengths and factors given below
Strength values quoted are per metre width of geogrid, and do not take into account percentage coverage
Design temperature (°C) 30 Design life (years) 120 Limit state ULS
Tensar Creep Installation Calculated Permissible Sliding
geogrid rupture damage safety factor working load coefficient
strength (kN/m) factor at 30°C (kN/m)

F B/A1 A2 γ f ds
RE520 22.76 1.0 1.75 13.0 0.85

Geogrid reinforcement design data


Geogrid design strength is calculated using the strengths and factors given below
Strength values quoted are per metre width of geogrid, and do not take into account percentage coverage
Design temperature (°C) 30 Design life (years) Seismic Limit state ULS
Tensar Tensile Installation Calculated Permissible Sliding
geogrid strength damage safety factor working load coefficient
(kN/m) factor at 30°C (kN/m)
A2 γ f ds
RE520 47.87 1.0 1.75 27.36 0.85

Geogrid reinforcement design data


Geogrid design strength is calculated using the strengths and factors given below
Strength values quoted are per metre width of geogrid, and do not take into account percentage coverage
Design temperature (°C) 30 Design life (years) 120 Limit state SLS
Tensar Creep Installation Calculated Permissible Sliding
geogrid rupture damage safety factor working load coefficient
strength (kN/m) factor at 30°C (kN/m)

F B/A1 A2 γ f ds
RE520 9.88 1.0 1.0 9.88 0.85

Reference Date 9 Jun 2015 Page 7 of 10


Tensar software output
TensarSoil® Version 2.07

Calculations in accordance with: 2-part wedge method - Bautechnik (seismic loading)

Connection strength
T c for each layer of reinforcement is determined for ULS as follows:
For modular block facings, T c is determined on the basis of block properties and connection test results as follows:

Modular block parameters Geogrid parameters

Block length Lu 0.400 (m) Type T uu A cs λ cs T cmax


Block height Hu 0.200 (m) (kN/m) (kN/m) (º) (kN/m)
Block width Wu 0.205 (m)
RE520 45.020 36.990 0.0 36.990
Weight incl. infill Gu 35.0 kg
Dist to CoG Du 0.100 (m)
Inclination of face αu 0.0 º
Max. grid spacing 0.400 (m)

Note that a partial factor of 1.75 is applied to the connection strength

Grid coordinates and serviceability results


Levels are measured from the datum and horizontal location is measured from the toe of the wall

Tensar Level Left Right Length Coverage Pullout Post


geogrid end end interaction construction
factor strain
fb

(m) (m) (m) (m) % %


RE520 6.60 0.20 5.30 5.09 100 0.85 0.18
RE520 6.20 0.20 5.30 5.09 100 0.85 0.49
RE520 5.80 0.20 5.30 5.09 100 0.85 0.61
RE520 5.40 0.20 5.30 5.09 100 0.85 0.67
RE520 5.00 0.20 5.30 5.09 100 0.85 0.72
RE520 4.60 0.20 5.30 5.09 100 0.85 0.76
RE520 4.20 0.20 5.30 5.09 100 0.85 0.79
RE520 3.80 0.20 5.30 5.09 100 0.85 0.82
RE520 3.40 0.20 5.30 5.09 100 0.85 0.85
RE520 3.00 0.20 5.30 5.09 100 0.85 0.85
RE520 2.60 0.20 5.30 5.09 100 0.85 0.85
RE520 2.20 0.20 5.30 5.09 100 0.85 0.79
RE520 1.80 0.20 5.30 5.09 100 0.85 0.68
RE520 1.40 0.20 5.30 5.09 100 0.85 0.53
RE520 1.00 0.20 5.30 5.09 100 0.85 0.38
RE520 0.60 0.20 5.30 5.09 100 0.85 0.23
RE520 0.20 0.20 5.30 5.09 100 0.85 0.07

Reference Date 9 Jun 2015 Page 8 of 10


Tensar software output
TensarSoil® Version 2.07

Calculations in accordance with: 2-part wedge method - Bautechnik (seismic loading)

Internal stability results


For static conditions:

Level: Inclined wedges Sliding between Sliding on


geogrids geogrids

θ c rit R Z R/Z θu F F

6.2 59.0 15.5 1.2 12.747 4.489 6.72 8.705


5.8 44.0 27.8 4.0 7.043 4.489 4.799 6.871
5.4 47.0 41.4 8.8 4.717 4.489 4.078 5.795
5.0 50.0 54.7 14.9 3.659 4.489 3.64 5.049
4.6 53.0 68.0 22.3 3.048 4.489 3.323 4.491
4.2 53.0 81.2 30.9 2.63 4.489 3.075 4.053
3.8 53.0 94.4 40.5 2.33 4.489 2.871 3.7
3.4 56.0 107.9 51.4 2.101 4.489 2.699 3.408
3.0 53.0 120.2 62.9 1.911 4.489 2.55 3.162
2.6 53.0 132.0 75.7 1.744 4.489 2.42 2.952
2.2 53.0 143.7 89.5 1.605 4.489 2.305 2.77
1.8 53.0 155.5 104.4 1.489 4.489 2.202 2.611
1.4 50.0 162.5 117.3 1.386 4.489 2.109 2.471
1.0 41.0 140.4 110.5 1.27 4.489 2.025 2.347
0.6 41.0 142.6 125.4 1.138 4.489 1.949 2.236
0.2 41.0 144.9 141.2 1.026 4.489 1.879 2.136
0.0 41.0 153.0 149.5 1.023 2.248 2.109 -

Requirement ≥ 1.0 ≥ 1.50 ≥ 1.50

For dynamic conditions, vertical acceleration acting downwards:


Level: Inclined wedges Sliding between Sliding on
geogrids geogrids

θ c rit R Z R/Z θu F F

6.2 44.0 15.7 2.0 7.854 4.489 4.488 6.844


5.8 47.0 38.3 5.6 6.875 4.489 3.718 5.445
5.4 44.0 61.7 10.9 5.66 4.489 3.305 4.628
5.0 44.0 87.6 18.0 4.86 4.489 3.012 4.059
4.6 41.0 111.7 26.7 4.184 4.489 2.783 3.632
4.2 41.0 135.8 37.3 3.641 4.489 2.594 3.295
3.8 41.0 157.3 49.5 3.176 4.489 2.434 3.021
3.4 41.0 177.3 62.7 2.829 4.489 2.297 2.794
3.0 44.0 202.9 79.0 2.568 4.489 2.176 2.601
2.6 38.0 201.7 86.7 2.327 4.489 2.07 2.436
2.2 32.0 178.4 86.8 2.056 4.489 1.975 2.293
1.8 29.0 162.7 90.7 1.793 4.489 1.89 2.167
1.4 29.0 165.5 105.4 1.571 4.489 1.812 2.056
1.0 29.0 168.4 121.3 1.388 4.489 1.742 1.957
0.6 26.0 150.1 122.6 1.225 4.489 1.678 1.868
0.2 26.0 150.7 139.6 1.079 4.489 1.62 1.788
0.0 29.0 186.6 166.6 1.12 2.248 1.797 -

Requirement ≥ 1.0 ≥ 1.125 ≥ 1.125

Reference Date 9 Jun 2015 Page 9 of 10


Tensar software output
TensarSoil® Version 2.07

Calculations in accordance with: 2-part wedge method - Bautechnik (seismic loading)

For dynamic conditions, vertical acceleration acting upwards:


Level: Inclined wedges Sliding between Sliding on
geogrids geogrids

θ c rit R Z R/Z θu F F

6.2 38.0 13.5 1.7 7.799 4.489 4.405 6.559


5.8 35.0 31.0 4.8 6.486 4.489 3.637 5.223
5.4 38.0 53.2 9.4 5.635 4.489 3.229 4.447
5.0 29.0 74.2 14.7 5.032 4.489 2.942 3.907
4.6 32.0 96.3 22.6 4.267 4.489 2.718 3.501
4.2 35.0 119.7 31.9 3.751 4.489 2.534 3.18
3.8 35.0 139.3 41.3 3.373 4.489 2.378 2.919
3.4 35.0 154.3 51.3 3.009 4.489 2.244 2.702
3.0 32.0 155.7 57.7 2.698 4.489 2.126 2.518
2.6 29.0 148.5 62.9 2.359 4.489 2.023 2.36
2.2 26.0 136.8 66.5 2.056 4.489 1.93 2.223
1.8 26.0 139.9 78.4 1.784 4.489 1.847 2.102
1.4 26.0 143.1 91.5 1.564 4.489 1.772 1.995
1.0 23.0 126.6 93.1 1.36 4.489 1.704 1.9
0.6 23.0 127.6 107.3 1.189 4.489 1.641 1.815
0.2 17.0 89.4 87.1 1.027 4.489 1.584 1.738
0.0 20.0 121.8 113.3 1.075 2.248 1.752 -

Requirement ≥ 1.0 ≥ 1.125 ≥ 1.125


Notes:
(1) Elevation measured from base of reinforced fill block.
(2) For wedge checks, Z is the resultant of all applied forces and R is the resistance provided by the reinforcement.
(3) For sliding on grid, Z is the sum of the activating forces and R is the sum of the resisting forces.
(4) For sliding between grids, forces are calculated for the steepest plane between the grid at the given elevation and the
grid immediately above.

Reference Date 9 Jun 2015 Page 10 of 10