PRODUCT DATA SHEET

SikaQuick®-1000
RAPID HARDENING REPAIR MORTAR WITH EXTENDED WORKING TIME

PRODUCT DESCRIPTION CHARACTERISTICS / ADVANTAGES


SikaQuick®-1000 is a one-component, rapid hardening, ▪ Specially suited for hot weather applications when ex-
early strength gaining, cementitious, patching material tended working time is required
for concrete. ▪ Epoxy coatings can be applied as early as 6 hours. On
site testing is recommended for verification. Please
USES consult coatings manufacturer for recommendations
▪ Freeze/thaw resistant
▪ Use on grade, above, and below grade on concrete ▪ Easy to use, labor-saving material
▪ Highway overlays and repairs ▪ Not gypsum-based
▪ Structural repair material for concrete roadways, park- ▪ High early strength
ing structures, bridges, dams and ramps ▪ Open to foot traffic in 4 hours; to vehicle traffic in 6
▪ Full depth patching repairs hours (at 73 °F, 23 °C)
▪ Economical patching material for horizontal repairs of ▪ Easily applied to clean, sound substrate
concrete and mortar
APPROVALS / STANDARDS
▪ Rapid hardening as defined by ASTM C-928

PRODUCT INFORMATION
Packaging 50 lb. (22.7 kg) bag
Appearance / Color Gray powder
Shelf Life 12 months from date of production if stored properly in original, unopened
and undamaged sealed packaging
Storage Conditions Store dry at 40–95 °F (4–35 °C).
Protect from moisture. If damp, discard material

TECHNICAL INFORMATION
Compressive Strength 3 hours 1,250 psi (8.6 MPa) (ASTM C-109)
1 day 4,000 psi (27.6 MPa) 73 °F (23 °C)
7 days 5,000 psi (34.5 MPa) 50 % R.H.
28 days 7,000 psi (48.2 MPa)

Product Data Sheet


SikaQuick®-1000
May 2018, Version 01.01
020302040040000011

1/4
Modulus of Elasticity in Compression 28 days 4.6 x 106 psi (ASTM C-469)
73 °F (23 °C)
50 % R.H.

Flexural Strength 1 day 700 psi (4.8 MPa) (ASTM C-293)


7 days 900 psi (6.2 MPa) 73 °F (23 °C)
28 days 1,000 psi (6.9 MPa) 50 % R.H.

Splitting Tensile Strength 1 day 200 psi (1.4 MPa) (ASTM C-496)
7 days 300 psi (2.1 MPa) 73 °F (23 °C)
28 days 400 psi (2.8 MPa) 50 % R.H.

Tensile Adhesion Strength 28 days 300 psi (2.1 MPa) (ASTM C-1583)
substrate failure 73 °F (23 °C)
50 % R.H.

Shrinkage 28 days 0.06 % (ASTM C-157


modified per
ASTM C-928)
* 73 °F (23 °C) and 50 % R.H.

Abrasion Resistance 28 days 0.026* (ASTM C-779)


*Inches of Wear at 1 h (73 °F (23 °C) and 50 % R.H.)

Freeze thaw resistance 28 days 98 % (ASTM C-666)

Freeze Thaw De-Icing Salt Resistance 50 cycles 0.080 lb/ft2 (ASTM C-672)

Chloride Ion Diffusion Resistance 28 days < 1,000 Coulombs (ASTM C-1202
AASHTO T-277)

APPLICATION INFORMATION
Mixing Ratio 4.5–5 pts. (2.1–2.4 L)
Coverage Neat 0.42 ft3 (0.01 m3)
Extended with 25 lb (11.4 kg) of 3/8" 0.58 ft3 (0.01 m3)
(9.5 mm) gravel
(Coverage figures do not include allowance for surface profile and porosity or material waste)

Layer Thickness Min. Max.


Neat 1/4" (6 mm) 1" (25 mm)
Extended 1" (25 mm) 6" (152 mm)
▪ Do not feather edge
▪ Do not exceed 7" (178 mm) slump when extended
Product Temperature 65–75 °F (18–24 °C)
Ambient Air Temperature 40–86 °F (4–30 °C)
Substrate Temperature 40–86 °F (4–30 °C)
Pot Life ~ 30 minutes
As the temperature will affect the pot life, application temperature:
▪ Above 73 °F (23 °C) will reduce the pot life and slump
▪ Below 73 °F (23 °C) will extend the pot life and slump
Initial Set Time 35–85 minutes (ASTM C-266)

Final Set Time > 120 minutes (ASTM C-266)

Product Data Sheet


SikaQuick®-1000
May 2018, Version 01.01
020302040040000011

2/4
APPLICATION INSTRUCTIONS ated surface dry, have low absorption and high density,
and comply with ASTM C-33 size number 8 per Table 2.
SUBSTRATE QUALITY / PRE-TREATMENT ▪ Variances in aggregate may result in different
strengths.
Surface preparation ▪ The addition rate is 25 lb. (11.4 kg) of aggregate per
▪ Surface must be clean and sound. Remove all deterior- bag. It is approximately 2.0 gallons (7.6 L) by loose
ated concrete, dirt, oil, grease, and other bond-inhibit- volume of aggregate.
ing materials from the area to be repaired. ▪ Do not exceed a slump of 7" (178 mm). This may cause
▪ Be sure repair area is not less than 1/4" (6.3 mm) deep. excessive bleeding and retardation and will reduce the
▪ Preparation work should be done by appropriate strength and performance of the material.
means. Obtain an exposed aggregate surface with a
minimum surface profile of ± 1/8" (3 mm) (CSP-6) on APPLICATION
clean, sound concrete.
▪ To ensure optimum repair results, the effectiveness of ▪ The prepared mortar must be scrubbed into substrate.
decontamination and preparation should be assessed Be sure to fill all pores and voids. Force material against
by a pull-off test. edge of repair, working toward center.
▪ Saw cutting of edges is preferred and a dovetail is re- ▪ After filling repair, screed off excess.
commended. ▪ Allow concrete to set to desired stiffness, then finish.
▪ Substrate should be Saturated Surface Dry (SSD) with ▪ If a smoother finish is desired, a magnesium float
clean water prior to application. No standing water should be used.
should remain during application. ▪ Mixing, placing, and finishing should not exceed 30
minutes maximum. To control setting times, cold wa-
Priming ter should be used in hot weather and hot water used
▪ Reinforcing steel: Steel reinforcement should be thor- in cold weather.
oughly prepared by mechanical cleaning to remove all CURING TREATMENT
traces of rust. Where corrosion has occurred due to the
presence of chlorides, the steel should be high pres- ▪ As per ACI recommendations for portland cement con-
sure washed with clean water after mechanical clean- crete, curing is required.
ing. For priming of reinforcing steel use Sika® Armatec® ▪ Moist cure with wet burlap and polyethylene,a fine
110 EpoCem (consult PDS). mist of water or a curing compound meeting ASTM C-
▪ Concrete Substrate: prime the prepared substrate with 309.
a scrub coat of SikaQuick®-1000 prior to placement of ▪ Moist cure should commence immediately after finish-
the mortar. The repair mortar has to be applied into ing. If necessary, protect newly applied material from
the wet scrub coat before it dries. rain.
▪ To prevent from freezing, cover with insulating materi-
MIXING al.
▪ Mechanically mix in an appropriately sized mortar mix-
er. Wet down all tools and mixer to be used. LIMITATIONS
▪ With water: Start with 4.5 pints (2.1 L) of water added ▪ Use only potable water
to the mixing vessel. Add 1 bag of SikaQuick®-1000 ▪ As with all cement based materials, avoid contact with
while continuing to mix. Add up to another 1/2 pint aluminum to prevent adverse chemical reaction and
(0.2 L) of water to achieve desired consistency. Do not possible product failure. Insulate potential areas of
over-water. contact by coating aluminum bars, rails, posts etc. with
an appropriate epoxy such as Sikadur® Hi-Mod 32.
▪ With SikaLatex® R: Pour 4.5 pints (2.1 L) of SikaLatex® ▪ Bonding agents like Sika® Armatec® 110 EpoCem and
R into the mixing container. Slowly add powder, mix others, which cure at a slower rate than SikaQuick®-
and adjust as above. 1000, should not be used. If bonding agents are used,
follow cure times for the bonding agents used as a
▪ With diluted SikaLatex® R: SikaLatex® R may be diluted guide prior to putting SikaQuick®-1000 in service. As-
up to 5:1 (water: SikaLatex® R) for projects requiring sure suitability with the manufacturer of the bonding
minimal polymer modification. Pour 4.5 pints (2.1 L) of agent.
the mixture into the mixing container. Slowly add ▪ Not a vapor barrier
powder, mix and adjust as above.
BASIS OF PRODUCT DATA
Extension with aggregates:
Results may differ based upon statistical variations de-
▪ For applications greater than 1" (25 mm) in depth, add
pending upon mixing methods and equipment, temper-
3/8" (9.5 mm) coarse aggregate.
ature, application methods, test methods, actual site
▪ The aggregate must be non-reactive (reference ASTM
conditions and curing conditions.
C-1260, C-227 and C-289), clean, well graded, satur-

Product Data Sheet


SikaQuick®-1000
May 2018, Version 01.01
020302040040000011

3/4
LOCAL RESTRICTIONS LEGAL NOTES
Prior to each use of any Sika product, the user must al- Prior to each use of any Sika product, the user must al-
ways read and follow the warnings and instructions on ways read and follow the warnings and instructions on
the product’s most current Product Data Sheet, product the product’s most current Product Data Sheet, product
label and Safety Data Sheet which are available online at label and Safety Data Sheet which are available online at
http://usa.sika.com/ or by calling Sika's Technical Ser- http://usa.sika.com/ or by calling Sika’s Technical Ser-
vice Department at 800.933.7452 nothing contained in vice Department at 800-933-7452. Nothing contained in
any Sika materials relieves the user of the obligation to any Sika materials relieves the user of the obligation to
read and follow the warnings and instructions for each read and follow the warnings and instruction for each
Sika product for each Sika product as set forth in the cur- Sika product as set forth in the current Product Data
rent Product Data Sheet, product label and Safety Data Sheet, product label and Safety Data Sheet prior to
Sheet prior to product use. product use. SIKA warrants this product for one year
from date of installation to be free from manufacturing
ECOLOGY, HEALTH AND SAFETY defects and to meet the technical properties on the cur-
rent Product Data Sheet if used as directed within shelf
Keep container tightly closed. Keep out of reach of chil- life. User determines suitability of product for intended
dren. Not for internal consumption. For industrial use use and assumes all risks. Buyer’s sole remedy shall be
only. For professional use only. For further information limited to the purchase price or replacement of product
and advice regarding transportation, handling, storage exclusive of labor or cost of labor. No other warranties
and disposal of chemical products, users should refer to express or implied shall apply including any warranty of
the actual Safety Data Sheets containing physical, ecolo- merchantability or fitness for a particular purpose. Sika
gical, toxicological and other safety related data. Read shall not be liable under any legal theory for special or
the current actual Safety Data Sheet before using the consequential damages. Sika shall not be responsible for
product. In case of emergency, call CHEMTREC at 1-800- the use of this product in a manner to infringe on any
424-9300, International 703-527-3887. patent or any other intellectual property rights held by
others. Sale of Sika products are subject to Sika's terms
DIRECTIVE 2004/42/CE - LIMITATION OF EMISSIONS OF and conditions of sale available at http://usa.sika.com/
VOC or by calling 201-933-8800.
0 g/L (EPA Method 24)

Sika Corporation Sika Canada Inc. Sika Mexicana S.A. de C.V.


201 Polito Avenue 601 Delmar Avenue Carretera Libre Celaya Km. 8.5
Lyndhurst, NJ 07071 Pointe Claire Fracc. Industrial Balvanera
Phone: 800-933-7452 Quebec H9R 4A9 Corregidora, Queretaro
Fax: 201-933-6225 Phone: 514-697-2610 C.P. 76920
Fax: 514-694-2792 Phone: 52 442 2385800
Fax: 52 442 2250537