You are on page 1of 42

Page: 1 of 42

EMC TEST REPORT


Reference No. : WT09051209-E-E-E

Applicant : Cherub Technology Company Limited


Address : Unit D, 8/F, Nanshan Bldg, No.15 Industry Rd. shekou Shenzhen 518067
China.

Equipment Under Test (EUT) :

Product Name : Amplifier with digital effects and built-in tuner


Model No. : Mighty15

Standards : EN 55013: 2001+A1:2003+A2: 2006


EN 61000-3-2 : 2006
EN 61000-3-3 : 2008
EN 55020: 2007

Date of Test : July 21, 2009


Test Engineer : Zero.Zhou
Reviewed By :

Test Result : PASS *

Prepared By:
Waltek Services (Shenzhen) Co., Ltd.
1/F, Fukangtai Building, West Baima Rd., Songgang Street, Baoan District,
Shenzhen 518105, China

Tel :+86-755-27553488
Fax:+86-755-27553868

* The sample detailed above has been tested to the requirements of Council Directives 2004/108/EC. The
test results have been reviewed against the Directives above and found to meet their essential
requirements.

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:2 of 42

1 Test Summary
Test Test Requirement Test Method Class / Severity Result
Mains Terminal Disturbance EN55013:2001+A2:2 EN55013:2001+A2:20
Class B PASS
Voltage, 150kHz to 30MHz 006 06
Disturbance Power, EN55013:2001+A2:2 EN55013:2001+A2:20
Class B PASS
30MHz to 300MHz 006 06
Disturbance Voltage at the EN55013:2001+A2:2 EN55013:2001+A2:20
Class B N/A
Antenna Terminals 006 06
Radiation Emission, 30MHz EN55013:2001+A2:2 EN55013:2001+A2:20
Class B N/A
to 1000MHz 006 06
Harmonic Emission on AC, Clause 7 of EN61000-
EN 61000-3-2 : 2006 EN 61000-3-2 : 2006 N/A
100Hz to 2kHz 3-2
Clause 5 of EN61000-
Flicker Emission on AC EN 61000-3-3 :2008 EN 61000-3-3 :2008 PASS
3-3
EN61000-4-2 :1995 ±4 kV Contact
ESD EN55020:2007 PASS
+ A2:2001 ±8 kV Air
Electrical Fast Transients AC±1.0kV
EN55020:2007 EN61000-4-4 :2004 PASS
on AC

Test Project S1 S2a S2b S3 S4 S5


Result of Test N/A PASS N/A PASS N/A PASS

Remark:
A.M. Amplitude Modulation.
P.M. Pulse Modulation.
† D.M. – Differential Mode
* UT is the nominal supply voltage

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:3 of 42

2 Contents
Page
1 COVER PAGE ......................................................................................................................................................... 1

1 TEST SUMMARY .................................................................................................................................................. 2

2 CONTENTS............................................................................................................................................................. 3

3 GENERAL INFORMATION ................................................................................................................................ 5


3.1 CLIENT INFORMATION ........................................................................................................................................... 5
3.2 GENERAL DESCRIPTION OF E.U.T. ........................................................................................................................ 5
3.3 DETAILS OF E.U.T................................................................................................................................................. 5
3.4 DESCRIPTION OF SUPPORT UNITS .......................................................................................................................... 5
3.5 STANDARDS APPLICABLE FOR TESTING ................................................................................................................ 5
3.6 TEST FACILITY ...................................................................................................................................................... 7
3.7 TEST LOCATION .................................................................................................................................................... 7
4 EQUIPMENT USED DURING TEST .................................................................................................................. 8

5 EMISSION TEST RESULTS .............................................................................................................................. 11


5.1 MAINS TERMINALS DISTURBANCE VOLTAGE, 150KHZ TO 30MHZ..................................................................... 11
5.1.1 E.U.T. Operation ...................................................................................................................................... 11
5.1.2 Measurement Data.................................................................................................................................... 11
5.1.3 Conducted Emissions Test Data ............................................................................................................... 12
5.1.4 Photograph – Mains Terminal Disturbance Voltage on AC Test Setup ................................................... 14
5.2 RADIATED DISTURBANCE POWER: 30MHZ TO 300MHZ ..................................................................................... 15
5.2.1 E.U.T. Operation ...................................................................................................................................... 15
5.2.2 Measurement Data.................................................................................................................................... 15
5.2.3 Radiated Disturbance Power Quasi-peak & Average Data ..................................................................... 16
5.2.4 Photograph –Radiated Disturbance Power Setup.................................................................................... 18
5.3 HARMONICS TEST RESULTS ................................................................................................................................ 19
5.4 FLICKER TEST RESULT ........................................................................................................................................ 20
5.4.1 FlickerTest Data ....................................................................................................................................... 20
5.4.2 Photograph- FlickerTest Setup................................................................................................................. 21
6 IMMUNITY TEST RESULTS ............................................................................................................................ 22
6.1 PERFORMANCE CRITERIA DESCRIPTION .............................................................................................................. 22
6.2 ESD .................................................................................................................................................................... 22
6.2.1 E.U.T. Operation ...................................................................................................................................... 22
6.2.2 Direct Application Test Results ................................................................................................................ 23
6.2.3 Indirect Application Test Results .............................................................................................................. 23
6.2.4 Photograph - ESD Test Setup ................................................................................................................... 24
6.3 ELECTRICAL FAST TRANSIENTS .......................................................................................................................... 25
6.3.1 E.U.T. Operation ...................................................................................................................................... 25
6.3.2 Test Results On AC Cable......................................................................................................................... 25
6.3.3 Photograph - EFT Test Setup For EUT On AC Cable ............................................................................. 26
6.4 S2A MEASUREMENT ............................................................................................................................................ 27
6.4.1 Immunity requirements to RF voltages for AC mains power connectors ................................................. 27
6.4.2 E.U.T. Operation ...................................................................................................................................... 28
6.4.3 Test Data................................................................................................................................................... 28
6.4.4 Photograph -S2a Measurement ................................................................................................................ 30
6.5 S3 MEASUREMENT .............................................................................................................................................. 31
6.5.1 Limits of Immunity to ambient electromagnetic fields of equipment ........................................................ 31
WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:4 of 42

6.5.2 E.U.T. Operation ...................................................................................................................................... 32


6.5.3 Test Data................................................................................................................................................... 32
6.5.4 Photograph -S3 Measurement .................................................................................................................. 34
6.6 KEYED CARRIER S5 MEASUREMENT ................................................................................................................... 35
6.6.1 E.U.T. Operation ...................................................................................................................................... 35
6.6.2 Measurement Conditions .......................................................................................................................... 35
6.6.3 Test Data................................................................................................................................................... 36
ELECTROMAGNETIC FIELD ............................................................................................................................................ 36
KEY CARRIER ............................................................................................................................................................... 36
MAGNETIC FIELD .......................................................................................................................................................... 36
6.6.4 Photograph -Keyed Carrier S5 Measurement .......................................................................................... 37
7 PHOTOGRAPHS - CONSTRUCTIONAL DETAILS...................................................................................... 38
7.1 EUT -FRONT VIEW ............................................................................................................................................. 38
7.2 EUT - BACK VIEW .............................................................................................................................................. 38
7.3 EUT - OPEN VIEW............................................................................................................................................... 39
7.4 EUT-PCB1 - FRONT VIEW .................................................................................................................................. 39
7.5 EUT-PCB1 - BACK VIEW ................................................................................................................................... 40
7.6 EUT-PCB2- FRONT VIEW................................................................................................................................... 40
7.7 EUT-PCB2 - BACK VIEW ................................................................................................................................... 41
8 CE LABEL ........................................................................................................................................................... 42

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page: 5 of 42

3 General Information
3.1 Client Information
Applicant: Cherub Technology Company Limited
Address of Applicant: Unit D, 8/F, Nanshan Bldg, No.15 Industry Rd. shekou
Shenzhen 518067 China

Manufacturer: Cherub Technology Company Limited


Address of Manufacturer: Unit D, 8/F, Nanshan Bldg, No.15 Industry Rd. shekou
Shenzhen 518067 China

3.2 General Description of E.U.T.


Product Name: Amplifier with digital effects and built-in tuner
Model No.: Mighty15
.

3.3 Details of E.U.T.


Power Supply: 220V, 50Hz, 30W

3.4 Description of Support Units


The EUT has been tested as an independent unit.

3.5 Standards Applicable for Testing


The customer requested EMC tests for an Amplifier with digital effects and built-in tuner.
The standards used were EN55013, EN61000-3-2, EN61000-3-3 for emissions & EN55020
for
immunity.

Table 1 : Tests Carried Out EN55013:2001+A2:2006


Standard Status
EN55013:2001+A2:2006 Mains Terminal Disturbance Voltage √
EN55013:2001+A2:2006 Disturbance Power √
EN55013:2001+A2:2006 Antenna Terminal Disturbance Voltage ×
EN55013:2001+A2:2006 Wanted Signal & Disturbance at RF Output Terminals of
×
Video Recorder
EN55013:2001+A2:2006 Radiation Emission, 30MHz to 1000MHz ×

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:6 of 42

Table 2 : Tests Carried Out Under EN 61000-3-2: 2006& EN61000-3-3: 2008

EN61000-3-2: 2006 Harmonic Emissions on AC ×


EN61000-3-3: 2008 Flicker Emissions on AC √
√ Indicates that the test is applicable
× Indicates that the test is not applicable
Table 3 : Tests Carried Out Under EN55020:2007
Standard Status
EN61000-4-2:1995 + A2:2001 Electro-static discharge √
EN61000-4-4:2004 Fast transients √

Test Project S1 S2a S2b S3 S4 S5


Result of Test × √ × √ × √

√ Indicates that the test is applicable


× Indicates that the test is not applicable

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:7 of 42

3.6 Test Facility


The test facility is recognized, certified, or accredited by the following organizations:

• IC – Registration No.:7760A
Waltek Services(Shenzhen) Co., Ltd. has been registered and fully described in a report filed
with the Industry Canada. The acceptance letter from the Industry Canada is maintained in our
files. Registration No.:7760A, July 24, 2008.

• FCC – Registration No.: 880581


Waltek Services(Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the (FCC) Federal Communications Commission. The
acceptance letter from the FCC is maintained in our files. Registration No.: 880581, June 24,
2008.

3.7 Test Location


Some Emission tests and some Immunity tests were performed at:-
Waltek Services(Shenzhen) Co., Ltd. at 1/F, Fukangtai Building, West Baima Rd.,Songgang
Street, Baoan District, Shenzhen, China.

The test items Antenna Terminal Disturbance Voltage ,S1,S2a,S2b,S3,S4,S5 were performed
at:-
Solid Industrial (Shenzhen) Co., Ltd. at 333 Bulong Highway Buji Longgang, Shenzhen,
Guangdong, China.

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:8 of 42

4 Equipment Used during Test


Equipment Manufacturer Equipment Cal. Due
Internal No Specification Cert. No Uncertainty
Name Model No Date Date
EMC Agilent/ MY45114 Wws200
W2008001 9k-26.5GHz Aug-08 Aug-09 ±1dB
Analyzer E7405A 943 81596
Trilog SCHWARZB 336
Broadband ECK MESS-
W2008002 30-3000 MHz Aug-08 Aug-09 ±1dB
Antenne 30- ELEKTROM/
3000 MHz VULB9163
Broad-band SCHWARZB 667 f<10 GHz:
Horn ECK MESS- ±1dB
Antenna 1- ELEKTROM/ W2008003 1-18GHz Aug-08 Aug-09 10GHz<f<
18 GHz VULB9163 18 GHz:
±1.5dB
Broadband SCHWARZB 9718-148
Preamplifier ECK MESS-
W2008004 0.5-18GHz Aug-08 Aug-09 ±1.2dB
0.5-18 GHz ELEKTROM/
BBV 9718
10m Coaxial SCHWARZB -
Cable with ECK MESS-
N-male ELEKTROM/
- - Aug-08 Aug-09 -
Connectors AK 9515 H
usable up to
18GHz,
10m 50 Ohm SCHWARZB
Coaxial ECK MESS-
Cable with ELEKTROM/
N- AK 9513
plug,individ
Aug-08 Aug-09
ual
length,usabl
e up to
3(5)GHz,
Connector
Positioning C&C LAB/
N/A N/A
Controller CC-C-IF
Color SUNSPO/ SP-
N/A N/A
Monitor 14C
Test ROHDE&SC 101155
Wws200
Receiver HWARZ/ W2005001 9k-3GHz Aug-08 Aug-09 ±1dB
80942
ESPI
EMI Beijingkehuan KH3931
9k-1GHz Aug-08 Aug-09
Receiver
Two-Line ROHDE&SC 100115
Wws200
V-Network HWARZ/ W2005002 50Ω/50μΗ Aug-08 Aug-09 ±10%
80941
ENV216
V-LISN SCHWARZB NSLK 8128-259
9k-30MHz
ECK MESS 8128
- Aug-08 Aug-09
ELEKTRONI
K

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:9 of 42

Equipment Manufacturer Equipment Cal. Due


Internal No Specification Cert. No Uncertainty
Name Model No Date Date
Absorbing ROHDE&SC 100205 W2005003 impandance50
Clamp HWARZ/ Ω Wws200
MDS-21 Aug-08 Aug-09 ±1dB
loss 80943
:17 dB
10m 50 Ohm SCHWARZB
Coaxial ECK MESS-
Cable with ELEKTROM/
N- AK 9514
plug,individ
Aug-08 Aug-09
ual
length,usabl
e up to
3(5)GHz,
Connectors
Power:
2000VA
Digital Em Test
V07451 Vol-range:0- Voltage
Power AG/Switzerlan W2008012
03095 300V distinguish:0
Analyzer d/ DPA 500
Freq_range: Wwd200 .025%
Aug-08 Aug-09
10-80Hz 81185 Power_freq
Vol-range:0- distinguish:0
Em Test
Power V07451 300V .02Hz
AG/Switzerlan W2008013
Source 03096 Power_freq:
d/ ACS 500
10-80Hz
Contact
discharge: 7.5A current
Electrostatic Em Test
V07451 500V-10KV Wwc200 will be
Discharge AG/Switzerlan W2008005 Aug-08 Aug-09
03094 Air 82400 changed in
Simulator d/DITO
diacharge: Vm=1.5V
500V-16.5KV
RF TESEQ 25781 Power_freq
Fraq-range:
Generator GmbH/ distinguish0.
9K-1GHz
NSG4070 Wws200 1Hz
W2008008 RF voltage:- Aug-08 Aug-09
81890 RFeletricity
60 dBm-
distinguish
+10dBm
0.1B
CDN M- TESEQ 25112 150K-
Type GmbH/ CDN 80MHz:
Voltage
M016 Wwc200 ±1dB
W2008009 correct factor Aug-08 Aug-09
82396 80-
9.5 dB
230MHz:-2-
+3dB
EM-Clamp TESEQ 25453 0.3-400
GmbH/ Freq_range: MHz:
Wwc200
KEMZ 801 W2008010 0.15-1000 Aug-08 Aug-09 ±4dB
82397
MHz Other freq:
±5dB
Attenuator TESEQ 25365
Wws200
6dB GmbH/ Aug-08 Aug-09
81597
ATN6050
All Modules SCHAFFNER 34579 W2008006 voltage:200V- Aug-08 Aug-09 Wwc200 voltage:
WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:10 of 42

Equipment Manufacturer Equipment Cal. Due


Internal No Specification Cert. No Uncertainty
Name Model No Date Date
Generator /6150 4.4KV 82401 ±10%
Pulse Pulse
current: current:
100A-2.2KA ±10%
Capacitive SCHAFFNER 25311
Wwc200
Coupling / CDN 8014 Aug-08 Aug-09 -
82398
Clamp
Signal and SCHAFFNER 25627
Data Line / CDN 117 1.2/50μS Wwc200
W2008011 Aug-08 Aug-09 -
Coupling 82399
Network
AC Power TONGYUN/ Wws200
Aug-08 Aug-09 -
Supply DTDGC-4 80944
Test
uncertainly

Narda Safety
Exposure Test freq 1-
TEST
Level Tester M-0155 w2008022 range:1- 120kHz:±1.
Solutions/230
ELT-400 400kHz 83%,
4/03
120 kHz-
400 kHz:
±4.06%
Magnetic Narda Safety M-1070 Wwd200 Test
Aug-08 Aug-09
Field Probe TEST 81191 uncertainly
100cm2 Solutions/230 :
0/90.10 1Hz-10Hz:
Test freq ±16.2%,
w2008021 range:1- 10Hz -
400kHz 120kHz:±2.
2%,
120 kHz-
400 kHz:
±4.7%
Active Loop
Antenna
Beijing Dazhi 10kHz-
Charger - - Aug-08 Aug-09 ±1dB
/ ZN30900A 30MHz
10kHz-
30MHz

Ipod 5K85004U
MP3 Player Aug-08 Aug-09 ±1dB
Player/A1285 3R0

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:11 of 42

5 Emission Test Results


5.1 Mains Terminals Disturbance Voltage, 150kHz to 30MHz
Test Requirement: EN 55013 Class B
Test Method: EN 55013 Class B
Test Result: PASS
Frequency Range: 150kHz to 30MHz
Class/Severity: Table 1 of EN55013
Detector: Peak for pre-scan (9kHz Resolution Bandwidth)
Quasi-Peak & Average if maximised peak within 6dB of Average
Limit

5.1.1 E.U.T. Operation

Operating Environment:
Temperature: 25.5°C
Humidity: 51 % RH
Atmospheric Pressure: 1012 mbar

EUT Operation :

The EUT was placed on the test table working in INPUT mode,CD/MP3 mode and LINE
IN mode, the worst case mode was tested in CD/MP3 mode,and playing with 1KHz signal.
so the data were shown as follow.
The maximised peak emissions from the EUT was scanned and measured for both the Live
and Neutral Lines. Quasi-peak & average measurements were performed if peak emissions
were within 6dB of the average limit line.

5.1.2 Measurement Data

An initial pre-scan was performed on the live and neutral lines.


No futher quasi-peak or average measurements were performed since no peak emissions were
detected within 10dB line below the average limit.
Please refer to the following peak scan graph for reference.

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:12 of 42

5.1.3 Conducted Emissions Test Data


Live Line:

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:13 of 42

Neutral Line:

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:14 of 42

5.1.4 Photograph – Mains Terminal Disturbance Voltage on AC Test Setup

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:15 of 42

5.2 Radiated Disturbance Power: 30MHz to 300MHz


Test Requirement: EN 55013 Class B
Test Method: EN 55013 Class B
Test Result: PASS
Frequency Range: 30MHz to 300MHz
Class/Severity: Table 4 of EN55013
Detector: Peak for pre-scan (120kHz resolution bandwidth)
Quasi-Peak & average if pre-scan peak within 15dB of average
limit.

5.2.1 E.U.T. Operation

Operating Environment:
Temperature: 25.5 °C
Humidity: 52 % RH
Barometric Pressure: 1012 mbar

EUT Operation:
The EUT was placed on the test table working in INPUT mode,CD/MP3 mode and LINE
IN mode, the worst case mode was tested in CD/MP3 mode,and playing with 1KHz signal.
so the data were shown as follow.

If any maximised peak emissions are detected within 15dB of the average limit line, then:
• Extend the lead to at least 6.2m (i.e. half wavelength at 30MHz plus twice the length
of the absorbing clamp) length or keep the original lead length (if no other lead can
is connected to the unit at the end of the lead).
• Maximise all peak emissions by moving clamp along cable.
• Perform Quasi-Peak and Average measurements on all maximised peak emissions
within 6dB of the average limit line.

5.2.2 Measurement Data


Extending the cable to 6 meters, performed quasi-peak & average measurements since peak
emissions from the EUT were detected within 15dB of the limit line.Average measurements
were only performed if the quasi-peak measurements were within 15dB of the average limit
line.
Please refer to the following peak scan graph for reference.

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:16 of 42

5.2.3 Radiated Disturbance Power Quasi-peak & Average Data


AC line

EARPHONE line

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:17 of 42

LINE IN line

INPUT line

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:18 of 42

5.2.4 Photograph –Radiated Disturbance Power Setup

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:19 of 42

5.3 Harmonics Test Results


Test Requirement: EN 61000-3-2
Test Method: EN 61000-3-2
Frequency Range: 100Hz to 2kHz
Test Result: N/A
There is no need for Harmonics test to be performed on this product (rated power is less than
75W) in accordance with EN61000-3-2 (2006).
For further details, please refer to Clause 7, Note 3 of EN61000-3-2 which states:-

“For the following categories of equipment limits are not specified in this edition of the
standard.
Note 1: Equipment with a rated power of 75W or less, other than lighting equipment.”

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:20 of 42

5.4 Flicker Test Result


Test Requirement: EN 61000-3-3
Test Method: EN 61000-3-3
Test Result PASS
Compliance test was performed in working mode and ‘on/off’ once during the test.

Short time (Pst): 10 min


Observation time: 10 min (1 Flicker measurement)

5.4.1 FlickerTest Data

Maximum Flicker results

EUT values Limit Result


Pst 0.028 1.00 PASS
dc [%] 0.004 3.30 PASS
dmax [%] 0.163 4.00 PASS
dt [s] 0.000 0.50 PASS

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:21 of 42

5.4.2 Photograph- FlickerTest Setup

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:22 of 42

6 Immunity Test Results


6.1 Performance Criteria Description

Criterion A: The apparatus shall continue to operate as intended. No degradation of


performance or loss of function is allowed below a performance level specified
by the manufacturer, when the apparatus is used as intended.
Criterion B: The apparatus shall continue to operate as intended after the test. No degradation
of performance or loss of function is allowed below a performance level
specified by the manufacturer, when the apparatus is used as intended.
Criterion C: Temporary loss of function is allowed, provided the function is self recoverable
or can be restored by the operation of the controls.
For further details, please refer to EN 55020.

6.2 ESD
Test Requirement: EN 55020
Test Method: EN 61000-4-2
Test Result: PASS
Discharge Impedance: 330 Ω / 150 pF
Discharge Voltage: Air Discharge: +/-8 kV
Contact Discharge: +/-4 kV
HCP & VCP: +/-4 kV
Polarity: Positive & Negative
Number of Discharge: Minimum 10 times at each test point
Discharge Mode: Single Discharge
Discharge Period: 1 second minimum

6.2.1 E.U.T. Operation

Operating Environment:
Temperature : 24.0 °C
Humidity : 52 % RH
Barometric Pressure : 1012 mbar
EUT Operation:
The EUT was placed on the test table in working mode and playing with 1KHz signal.

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:23 of 42

6.2.2 Direct Application Test Results


Observations : Test points : 1. All Exposed Surface & Seams;
2. All metallic part
Direct Application Test Results
Discharge Level (kV) Polarity (+/-) Test Point Contact Discharge Air Discharge
8 +/- 1 N/A A
4 +/- 2 A N/A

Results
A: No degradation in the performance of the E.U.T. was observed.
N/A: Not applicable.

6.2.3 Indirect Application Test Results


Observations : Test points : 1. All sides.
Indirect Application Test Results
Discharge Level (kV) Polarity (+/-) Test Point Horizontal Coupling Vertical Coupling
4 +/- 1 A A

Results:

A: No degradation in the performance of the E.U.T. was observed.

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:24 of 42

6.2.4 Photograph - ESD Test Setup

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:25 of 42

6.3 Electrical Fast Transients


Test Requirement: EN 55020
Test Method: EN 61000-4-4
Test Result: PASS
Test Level: 1.0kV on AC
Polarity: Positive & Negative
Repetition Frequency: 5kHz
Burst Duration: 300ms
Test Duration: 2 minutes per level & polarity

6.3.1 E.U.T. Operation


Operating Environment:
Temperature: 25.5 °C
Humidity: 52 % RH
Barometric Pressure: 1012 mbar
EUT Operation:
The EUT was placed on the test table in working mode and playing with 1KHz signal.

6.3.2 Test Results On AC Cable

Lead Level Observations


Coupling
under EUT operating mode
(±kV) Direct/Clamp (Performance Criterion)
Test
±1.0
AC Live Direct ON and Idle mode No loss of function
±0.5
AC ±1.0
Direct ditto ditto
Neutral ±0.5
AC Live & ±1.0
Direct ditto ditto
Neutral ±0.5

Results:

A: No degradation in the performance of the E.U.T. was observed.

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:26 of 42

6.3.3 Photograph - EFT Test Setup For EUT On AC Cable

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:27 of 42

6.4 S2a Measurement


Test Requirement: EN 55020
Test Method: EN 55020
Test Result: PASS
Test Part: AC Mains 、Audio input and output

6.4.1 Immunity requirements to RF voltages for AC mains power connectors

Limits of immunity to RF voltages of mains, loudspeaker and headphone terminals


Frequency Level
MHz dB(μV) (e.m.f.)
0.15 to 30 130
30 to 100 120
100 to 150 120-110a
a
Decreasing linearly with the logarithm of the frequency

Limits of immunity to RF voltages of audio input and output terminals

Frequency Level
MHz dB(μV) (e.m.f.)
0.15 to 1.6 80-90 a
1.6 to 20 90-120 a
20 to 100 120
b
100 to 150 120-110
a
Increasing linearly with the logarithm of the frequency
b
Decreasing linearly with the logarithm of the frequency

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:28 of 42

6.4.2 E.U.T. Operation

Operating Environment:
Temperature : 23.0 °C
Humidity : 52 % RH
Barometric Pressure : 1012 mbar
EUT Operation:
The EUT was placed on the test table in working mode.

6.4.3 Test Data

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:29 of 42

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:30 of 42

6.4.4 Photograph -S2a Measurement

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:31 of 42

6.5 S3 Measurement
Test Requirement: EN 55020
Test Method: EN 55020
Test Result: PASS

6.5.1 Limits of Immunity to ambient electromagnetic fields of equipment

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:32 of 42

6.5.2 E.U.T. Operation

Operating Environment:
Temperature : 23.0 °C
Humidity : 52% RH
Barometric Pressure : 1012 mbar
EUT Operation:
The EUT was placed on the test table in working mode,and the worse terminal were recorded.

6.5.3 Test Data

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:33 of 42

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:34 of 42

6.5.4 Photograph -S3 Measurement

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:35 of 42

6.6 Keyed Carrier S5 Measurement


Test Requirement: EN 55020
Test Method: EN 61000-4-3
Test Result: PASS
Test Specification: 900MHz, 3V/m,
duty cycle 1/8,
217Hz repetition frequency

6.6.1 E.U.T. Operation

Operating Environment:
Temperature : 24.0 °C
Humidity : 52 % RH
Barometric Pressure : 1012 mbar
EUT Operation:
The EUT was placed on the test table in working mode.

6.6.2 Measurement Conditions


The Equipment shall be placed on a non-conducting table with a height of 80cm. Test shall
be done with a vertical polarised field with the equipment in one position.

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:36 of 42

6.6.3 Test Data

Immunity Immunity to Ambient


Enclosure EN 61000-4-3
Electromagnetic Fields
(Keyed Carrier)
Criterion: A Total: PASS
Ambient: 25ºC 52% RH 1012mbar
Operation Mode: working

Electromagnetic Field Key Carrier Magnetic Field

Freq. Range: Frequency: 900MHz Frequency:

Field Strength: V/m Field 3V/m Field Strength: A/m


Strength:

Modulation Modulation

none AM Pulse % kHz Duty cycle: 1/8


Repetion time: 217Hz

Front Vertical PASS Front Horizontal PASS


Left Vertical PASS Left Horizontal PASS
Back Vertical PASS Back Horizontal PASS
Right Vertical PASS Right Horizontal PASS

Comments:
A: No degradation in the performance of the E.U.T. was observed.

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:37 of 42

6.6.4 Photograph -Keyed Carrier S5 Measurement

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:38 of 42

7 Photographs - Constructional Details

7.1 EUT -Front View

7.2 EUT - Back View

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:39 of 42

7.3 EUT - Open View

7.4 EUT-PCB1 - Front View

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:40 of 42

7.5 EUT-PCB1 - Back View

7.6 EUT-PCB2- Front View

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:41 of 42

7.7 EUT-PCB2 - Back View

WALTEK SERVICES
Reference No.: WT09051209-E-E-E
Page:42 of 42

8 CE Label
1. The CE conformity marking must consist of the initials‘CE’taking the following form:
If the CE marking is reduced or enlarged, the proportions given in the above graduated
drawing must be respected.
2. The CE marking must have a height of at least 5 mm except where this is not possible on
account of the nature of the apparatus.
3. The CE marking must be affixed to the product or to its data plate. Additionally it must be
affixed to the packaging, if any, and to the accompanying documents.
4. The CE marking must be affixed visibly, legibly and indelibly.
It must have the same height as the initials‘CE’

Proposed Label Location on EUT


EUT Bottom View/proposed CE Mark Location

WALTEK SERVICES
Reference No.: WT09051209-E-E-E

You might also like