2.- COLUMNAS........................................................................................................................ 2
2.1.- C1............................................................................................................................ 2
2.2.- C2............................................................................................................................ 3
2.3.- C3............................................................................................................................ 4
2.4.- C4............................................................................................................................ 4
2.5.- C5............................................................................................................................ 5
2.6.- C6............................................................................................................................ 6
2.7.- C7............................................................................................................................ 7
2.8.- C8............................................................................................................................ 8
2.9.- C9............................................................................................................................ 9
2.10.- C10.......................................................................................................................... 10
2.11.- C11.......................................................................................................................... 11
2.12.- C12.......................................................................................................................... 12
2.13.- C13.......................................................................................................................... 13
2.14.- C14.......................................................................................................................... 14
2.15.- C15.......................................................................................................................... 15
2.16.- C16.......................................................................................................................... 16
2.17.- C17.......................................................................................................................... 17
2.18.- C18.......................................................................................................................... 18
2.19.- C19.......................................................................................................................... 19
2.20.- C20.......................................................................................................................... 20
2.21.- C21.......................................................................................................................... 21
2.22.- C22.......................................................................................................................... 22
2.23.- C23.......................................................................................................................... 23
2.24.- C24.......................................................................................................................... 24
2.25.- C25.......................................................................................................................... 25
2.26.- C26.......................................................................................................................... 26
2.27.- C27.......................................................................................................................... 27
2.28.- C28.......................................................................................................................... 28
2.29.- C29.......................................................................................................................... 29
2.30.- C30.......................................................................................................................... 30
2.31.- C31.......................................................................................................................... 30
2.32.- C32.......................................................................................................................... 31
2.- COLUMNAS
2.1.- C1
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S Q S. 94.4 -74.1 52.9 -124.0 -197.2
(3)
Cumbrera Cubierta (6.6 - 9.47 m) 40x40 8.57 m Cumple Cumple 68.2 100.0 Cumple Cumple 100.0 G, S Q S.,N,M S. 106.0 110.1 -73.0 -124.0 -197.2 Cumple
(3)
7.1 m Cumple Cumple 95.3 100.0 Cumple Cumple 100.0 G, S Q S.,N,M S. 106.0 110.1 -73.0 -124.0 -197.2 Cumple
(3)
Pie Cumple Cumple 68.2 100.0 Cumple Cumple 100.0 G, S Q S.,N,M S. 106.0 110.1 -73.0 -124.0 -197.2 Cumple
(3)
6.6 m N.P. N.P. N.P. 100.0 N.P. Cumple 100.0 N,M S. 106.0 110.1 -73.0 -124.0 -197.2 Cumple
(1) (1) (2) (1)
G, S
(3)
Cabeza Cumple Cumple 40.7 21.7 Cumple Cumple 40.7 G, S Q S.,N,M S. -0.3 -7.7 23.6 -25.8 -18.7 Cumple
(5)
5.7 m Cumple Cumple 40.7 21.7 Cumple Cumple 40.7 G, S Q S.,N,M S. -0.3 -7.7 23.6 -25.8 -18.7 Cumple
(5)
Cimentación 40x40 Desplantes N.P. N.P. N.P. 98.9 N.P. Cumple 98.9 N,M S. 32.3 -118.0 9.7 12.8 140.3 Cumple
(1) (1) (2) (1)
G, S
(8)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM-0.3·SX1+SY1
(4)
1.2·PP+1.2·CM+0.5·Qa-0.3·SX1+SY1
(5)
0.9·PP+0.9·CM+0.3·SX1-SY1
(6)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX1-SY1
(7)
1.2·PP+1.2·CM+0.5·Qa-0.3·SX2+SY2
(8)
0.9·PP+0.9·CM+0.3·SX2-SY2
Página 2
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.2.- C2
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, CV, S Q S. 45.3 1.5 -29.7 89.4 4.7
(3)
Pie Cumple Cumple 45.5 92.6 Cumple Cumple 92.6 G, CV, S(3) Q S.,N,M S. 52.8 5.2 58.8 89.4 4.7 Cumple
G, S Q S. -11.3 5.2 -98.1 142.3 21.5
(5)
Página 3
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.3.- C3
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
Cabeza Cumple Cumple 41.1 52.4 Cumple Cumple 52.4 G, S (3)
Q S.,N,M S. -14.4 2.6 -26.8 85.1 7.2 Cumple
5.7 m Cumple Cumple 41.9 99.1 Cumple Cumple 99.1 G, CV, S Q S.,N,M S. 51.9 14.7 -55.8 -87.3 -14.4 Cumple
(4)
Pie Cumple Cumple 41.9 99.1 Cumple Cumple 99.1 G, CV, S(4) Q S.,N,M S. 51.9 14.7 -55.8 -87.3 -14.4 Cumple
Cabeza Cumple Cumple 54.5 90.1 Cumple Cumple 90.1 G, CV, S Q S.,N,M S. 41.1 -30.6 101.2 -144.2 -32.1 Cumple
(4)
2.3 m Cumple Cumple 54.5 94.4 Cumple Cumple 94.4 G, CV, S Q S.,N,M S. 56.2 30.2 -107.2 -144.2 -32.1 Cumple
(4)
Cimentación 35x35 Desplantes N.P. N.P. N.P. 94.4 N.P. Cumple 94.4 G, CV, S N,M S. 56.2 30.2 -107.2 -144.2 -32.1 Cumple
(1) (1) (2) (1) (4)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
0.9·PP+0.9·CM+SX1-0.3·SY1
(4)
1.2·PP+1.2·CM+0.5·Qa-SX1+0.3·SY1
2.4.- C4
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S Q S. 79.4 -33.9 -41.7 124.0 -15.2
(3)
Cumbrera Cubierta (6.6 - 9.992 m) 40x40 8.57 m Cumple Cumple 35.6 83.2 Cumple Cumple 83.2 G, S Q S.,N,M S. 91.0 -1.9 95.7 124.0 -15.2 Cumple
(3)
(3)
7.1 m Cumple Cumple 72.7 83.2 Cumple Cumple 83.2 G, S Q S.,N,M S. 91.0 -1.9 95.7 124.0 -15.2 Cumple
(3)
Pie Cumple Cumple 35.6 83.2 Cumple Cumple 83.2 G, S Q S.,N,M S. 91.0 -1.9 95.7 124.0 -15.2 Cumple
(1) (1) (2) (1) (3)
6.6 m N.P. N.P. N.P. 83.2 N.P. Cumple 83.2 G, S N,M S. 91.0 -1.9 95.7 124.0 -15.2 Cumple
(5)
G, S Q S. 64.3 -12.9 14.8 -19.5 -26.1
Cabeza Cumple Cumple 31.0 17.8 Cumple Cumple 31.0 (6) Cumple
G, S N,M S. 72.4 12.9 20.4 -13.3 13.2
(7)
Cubierta (3.4 - 6.6 m) 40x40 G, CV, S Q S. 104.4 24.3 -3.6 -19.7 -28.8
3.9 m Cumple Cumple 34.3 16.6 Cumple Cumple 34.3 (8) Cumple
G, CV N,M 121.2 24.1 7.0 -0.6 -9.3
(7)
G, CV, S Q S. 104.4 24.3 -3.6 -19.7 -28.8
Pie Cumple Cumple 34.3 16.6 Cumple Cumple 34.3 (8) Cumple
G, CV N,M 121.2 24.1 7.0 -0.6 -9.3
(9)
G, CV, S Q S. 240.5 -82.6 10.6 -39.5 -133.9
Cabeza Cumple Cumple 39.9 58.7 Cumple Cumple 58.7 (10) Cumple
G, CV, S N,M S. 269.1 -81.0 -28.2 43.8 -128.8
(9)
G, CV, S Q S. 260.3 122.6 -35.9 -39.5 -133.9
2.3 m Cumple Cumple 40.6 95.2 Cumple Cumple 95.2 (5) Cumple
G, S N,M S. 123.5 43.4 -116.0 -125.4 -45.0
Entrepiso (-1.2 - 3.4 m) 40x40 (9)
G, CV, S Q S. 260.3 122.6 -35.9 -39.5 -133.9
-0.5 m Cumple Cumple 81.7 95.2 Cumple Cumple 95.2 (5) Cumple
G, S N,M S. 123.5 43.4 -116.0 -125.4 -45.0
(9)
G, CV, S Q S. 260.3 122.6 -35.9 -39.5 -133.9
Pie Cumple Cumple 40.6 95.2 Cumple Cumple 95.2 (5) Cumple
G, S N,M S. 123.5 43.4 -116.0 -125.4 -45.0
(1) (1) (2) (1) (5)
Cimentación 40x40 Desplantes N.P. N.P. N.P. 95.2 N.P. Cumple 95.2 G, S N,M S. 123.5 43.4 -116.0 -125.4 -45.0 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM+SX1-0.3·SY1
(4)
1.2·PP+1.2·CM+0.5·Qa+SX1-0.3·SY1
(5)
0.9·PP+0.9·CM-SX1+0.3·SY1
(6)
1.2·PP+1.2·CM-0.3·SX2-SY2
(7)
1.2·PP+1.2·CM+0.5·Qa-SX1+0.3·SY1
(8)
1.2·PP+1.2·CM+1.6·Qa
(9)
1.2·PP+1.2·CM+0.5·Qa-0.3·SX1+SY1
(10)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX2+SY2
Página 4
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.5.- C5
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, CV, S (3)
Q S. 107.2 59.4 -12.6 53.3 193.1
Cabeza Cumple Cumple 71.5 52.1 Cumple Cumple 71.5 Cumple
G, CV, S N,M S. 102.7 54.2 -20.5 78.7 176.7
(4)
G, CV, S (3)
Q S. 116.1 -105.2 33.0 53.3 193.1
8.57 m Cumple Cumple 74.7 99.7 Cumple Cumple 99.7 Cumple
G, CV, S(4) N,M S. 111.6 -96.9 46.1 78.7 176.7
Cumbrera Cubierta (6.6 - 9.532 m) 35x35
G, CV, S Q S. 116.1 -105.2 33.0 53.3 193.1
(3)
G, S
(5)
Q S. 107.0 -53.1 -0.1 0.7 -119.1
Cabeza Cumple Cumple 42.5 42.8 Cumple Cumple 42.8 Cumple
G, CV, S N,M S. 136.9 49.6 16.0 -14.0 117.4
(3)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX2-SY2
(4)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX1-SY1
(5)
0.9·PP+0.9·CM-0.3·SX2+SY2
(6)
1.2·PP+1.2·CM+0.5·Qa-0.3·SX2+SY2
(7)
1.2·PP+1.2·CM+0.5·Qa-0.3·SX2-SY2
Página 5
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.6.- C6
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S Q S. 59.4 0.4 11.4 -20.5 -1.8
(3)
Cabeza Cumple Cumple 57.2 84.5 Cumple Cumple 84.5 G, CV, S Q S.,N,M S. 139.5 12.3 -79.2 158.0 24.5 Cumple
(4)
5.7 m Cumple Cumple 57.2 84.7 Cumple Cumple 84.7 G, CV, S Q S.,N,M S. 146.9 -11.4 79.2 158.0 24.5 Cumple
(4)
Pie Cumple Cumple 57.2 84.7 Cumple Cumple 84.7 G, CV, S Q S.,N,M S. 146.9 -11.4 79.2 158.0 24.5 Cumple
(4)
Cabeza Cumple Cumple 46.5 75.8 Cumple Cumple 75.8 G, CV, S Q S.,N,M S. 179.1 20.7 -97.0 135.5 31.7 Cumple
(4)
Cimentación 35x35 Desplantes N.P. N.P. N.P. 83.2 N.P. Cumple 83.2 G, CV, S N,M S. 432.4 23.5 -92.1 -128.2 -31.3 Cumple
(1) (1) (2) (1) (6)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
0.9·PP+0.9·CM-SX1+0.3·SY1
(4)
1.2·PP+1.2·CM+0.5·Qa+SX1-0.3·SY1
(5)
1.2·PP+1.2·CM+SX1-0.3·SY1
(6)
1.2·PP+1.2·CM+0.5·Qa-SX1+0.3·SY1
(7)
0.9·PP+0.9·CM+SX1-0.3·SY1
Página 6
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.7.- C7
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S Q S. 51.6 0.5 -13.1 20.1 2.2
(3)
Cumbrera Cubierta (6.6 - 12.068 m) 35x35 10.812 m Cumple Cumple 33.8 26.2 Cumple Cumple 33.8 G, S Q S.,N,M S. 61.6 -3.9 23.1 20.1 2.2 Cumple
(3)
7.442 m Cumple Cumple 33.8 26.2 Cumple Cumple 33.8 G, S Q S.,N,M S. 61.6 -3.9 23.1 20.1 2.2 Cumple
(3)
Pie Cumple Cumple 33.8 26.2 Cumple Cumple 33.8 G, S Q S.,N,M S. 61.6 -3.9 23.1 20.1 2.2 Cumple
(3)
Pie Cumple Cumple 55.1 79.1 Cumple Cumple 79.1 G, CV, S Q S.,N,M S. 128.7 10.9 -74.3 -152.0 -26.9 Cumple
(5)
Cimentación 35x35 Desplantes N.P. N.P. N.P. 87.9 N.P. Cumple 87.9 G, CV, S N,M S. 434.8 -26.6 90.8 126.5 34.1 Cumple
(1) (1) (2) (1) (4)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
0.9·PP+0.9·CM+SX1-0.3·SY1
(4)
1.2·PP+1.2·CM+0.5·Qa+SX1-0.3·SY1
(5)
1.2·PP+1.2·CM+0.5·Qa-SX1+0.3·SY1
(6)
0.9·PP+0.9·CM-SX1+0.3·SY1
(7)
1.2·PP+1.2·CM+0.5·Qa-SX1-0.3·SY1
Página 7
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.8.- C8
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo (cm) Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
Disp. Arm. (%) (%) Disp. S. Cap. (%) Naturaleza Comp. (kN) (kN·m) (kN·m) (kN) (kN)
Cabeza Cumple Cumple 42.5 58.4 Cumple Cumple 58.4 G, CV, S Q S.,N,M S. 93.9 2.7 33.0 -88.0 -11.1 Cumple
(3)
Cimentación 30x30 Desplantes N.P.(1) N.P.(1) N.P.(2) 78.6 N.P.(1) Cumple 78.6 G, CV, S(6) N,M S. 341.0 -50.8 18.1 20.1 69.1 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM+0.5·Qa-SX1+0.3·SY1
(4)
0.9·PP+0.9·CM-SX1+0.3·SY1
(5)
0.9·PP+0.9·CM-0.3·SX1+SY1
(6)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX1-SY1
(7)
0.9·PP+0.9·CM+0.3·SX1-SY1
Página 8
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.9.- C9
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, CV, S Q S. 105.5 -70.3 18.0 -62.0 -249.4
(3)
6.6 m N.P. N.P. N.P. 96.8 N.P. Cumple 96.8 N,M S. 88.4 136.7 -30.7 -62.4 -247.7 Cumple
(1) (1) (2) (1)
G, S
(4)
Cubierta (3.4 - 6.6 m) 40x40 5.7 m Cumple Cumple 46.5 25.3 Cumple Cumple 46.5 Cumple
G, CV, S N,M S. 140.7 29.1 22.7 -22.2 42.4
(6)
Pie Cumple Cumple 32.6 18.3 Cumple Cumple 32.6 G, CV, S Q S.,N,M S. 153.9 -24.5 -12.0 -22.2 42.4 Cumple
(6)
Cimentación 40x40 Desplantes N.P. N.P. N.P. 86.3 N.P. Cumple 86.3 G, CV, S N,M S. 323.1 -46.8 -117.4 -127.9 48.6 Cumple
(1) (1) (2) (1) (8)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM+0.5·Qa-0.3·SX2+SY2
(4)
0.9·PP+0.9·CM-0.3·SX2+SY2
(5)
0.9·PP+0.9·CM+0.3·SX2-SY2
(6)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX2-SY2
(7)
1.2·PP+1.2·CM+0.5·Qa-0.3·SX2-SY2
(8)
1.2·PP+1.2·CM+0.5·Qa-SX1-0.3·SY1
Página 9
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.10.- C10
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. (%) (%) Disp. S. Cap. (%) Naturaleza Comp. (kN) (kN·m) (kN·m) (kN) (kN)
G, S
(3)
Q S. 34.2 0.0 10.7 -20.5 -2.0
Cabeza Cumple Cumple 31.7 14.2 Cumple Cumple 31.7 Cumple
G, S(4) N,M S. 112.6 -0.2 -12.9 22.0 2.0
G, S(5) Q S. 101.4 -3.2 25.2 21.7 2.0
10.709 m Cumple Cumple 35.5 26.8 Cumple Cumple 35.5 Cumple
G, S
(4)
N,M S. 125.7 -3.2 25.9 22.0 2.0
Cumbrera Cubierta (6.6 - 11.974 m) 35x35
G, S
(5)
Q S. 101.4 -3.2 25.2 21.7 2.0
7.442 m Cumple Cumple 35.5 26.8 Cumple Cumple 35.5 Cumple
G, S
(4)
N,M S. 125.7 -3.2 25.9 22.0 2.0
G, S
(5)
Q S. 101.4 -3.2 25.2 21.7 2.0
Pie Cumple Cumple 35.5 26.8 Cumple Cumple 35.5 Cumple
G, S
(4)
N,M S. 125.7 -3.2 25.9 22.0 2.0
G, CV, S Q S. 92.4 14.2 -77.0 154.7 27.0
(6)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
0.9·PP+0.9·CM-SX1+0.3·SY1
(4)
1.2·PP+1.2·CM+SX1-0.3·SY1
(5)
0.9·PP+0.9·CM+SX1-0.3·SY1
(6)
1.2·PP+1.2·CM+0.5·Qa+SX1-0.3·SY1
(7)
1.2·PP+1.2·CM+0.5·Qa-SX1-0.3·SY1
Página
1010
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.11.- C11
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, CV, S Q S. 42.7 -0.3 -19.3 28.0 2.9
(3)
5.7 m Cumple Cumple 76.7 97.0 Cumple Cumple 97.0 G, CV, S Q S.,N,M S. 83.1 20.1 -106.6 -212.9 -39.3 Cumple
(5)
Cubierta (3.4 - 6.6 m) 35x35
3.9 m Cumple Cumple 88.1 97.0 Cumple Cumple 97.0 G, CV, S Q S.,N,M S. 83.1 20.1 -106.6 -212.9 -39.3 Cumple
(5)
Pie Cumple Cumple 76.7 97.0 Cumple Cumple 97.0 G, CV, S Q S.,N,M S. 83.1 20.1 -106.6 -212.9 -39.3 Cumple
(5)
3.4 m N.P. N.P. N.P. 95.8 N.P. Cumple 95.8 N,M S. 52.2 18.8 -102.8 -210.2 -38.6 Cumple
(1) (1) (2) (1)
G, S
(6)
Cabeza Cumple Cumple 45.3 81.3 Cumple Cumple 81.3 G, CV, S Q S.,N,M S. 121.4 -21.7 85.7 -122.2 -31.1 Cumple
(5)
Pie Cumple Cumple 45.5 91.1 Cumple Cumple 91.1 G, CV, S Q S.,N,M S. 136.6 25.3 -94.9 -122.2 -31.1 Cumple
(5)
Cimentación 35x35 Desplantes N.P. N.P. N.P. 91.1 N.P. Cumple 91.1 G, CV, S N,M S. 136.6 25.3 -94.9 -122.2 -31.1 Cumple
(1) (1) (2) (1) (5)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM+0.5·Qa+SX1-0.3·SY1
(4)
0.9·PP+0.9·CM+SX1-0.3·SY1
(5)
1.2·PP+1.2·CM+0.5·Qa-SX1+0.3·SY1
(6)
0.9·PP+0.9·CM-SX1+0.3·SY1
(7)
1.2·PP+1.2·CM-SX1+0.3·SY1
Pie Cumple Cumple G(1) 97.7 -0.9 3.1 1.1 0.1 Cumple
Cabeza Cumple Cumple G 135.1 -0.8 6.7 -6.2 -1.5 Cumple
(1)
Pie Cumple Cumple G(1) 146.9 3.5 -10.7 -6.2 -1.5 Cumple
Cabeza Cumple Cumple G 287.2 -3.3 9.3 -3.5 -1.2 Cumple
(1)
Cimentación 35x35 - - - - - - - - - -
Notas:
(1)
1.4·PP+1.4·CM
Página
1111
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.12.- C12
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo (cm) Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
Disp. Arm. (%) (%) Disp. S. Cap. (%) Naturaleza Comp. (kN) (kN·m) (kN·m) (kN) (kN)
Cabeza Cumple Cumple 42.8 55.6 Cumple Cumple 55.6 G, CV, S Q S.,N,M S. 94.1 2.5 31.7 -88.8 -10.3 Cumple
(3)
5.7 m Cumple Cumple 43.5 70.6 Cumple Cumple 70.6 G, CV, S Q S.,N,M S. 149.0 42.7 -13.2 18.2 86.2 Cumple
(5)
G, S
(6)
Q S. 205.3 67.0 -21.0 29.1 106.7
Cabeza Cumple Cumple 37.0 75.3 Cumple Cumple 75.3 Cumple
G, CV, S N,M S. 297.2 67.3 -24.1 30.3 107.1
(5)
G, S
(6)
Q S. 216.7 -82.6 26.6 29.1 106.7
2.3 m Cumple Cumple 37.3 93.2 Cumple Cumple 93.2 Cumple
G, CV, S(5) N,M S. 312.4 -83.0 28.3 30.3 107.1
Entrepiso (-1.2 - 3.4 m) 35x35
G, S(6) Q S. 216.7 -82.6 26.6 29.1 106.7
-0.5 m Cumple Cumple 68.2 93.2 Cumple Cumple 93.2 Cumple
G, CV, S(5) N,M S. 312.4 -83.0 28.3 30.3 107.1
G, S
(6)
Q S. 216.7 -82.6 26.6 29.1 106.7
Pie Cumple Cumple 37.3 93.2 Cumple Cumple 93.2 Cumple
G, CV, S(5) N,M S. 312.4 -83.0 28.3 30.3 107.1
Cimentación 35x35 Desplantes N.P.(1) N.P.(1) N.P.(2) 93.2 N.P.(1) Cumple 93.2 G, CV, S(5) N,M S. 312.4 -83.0 28.3 30.3 107.1 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM+0.5·Qa-SX1+0.3·SY1
(4)
0.9·PP+0.9·CM-SX1+0.3·SY1
(5)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX1-SY1
(6)
0.9·PP+0.9·CM+0.3·SX1-SY1
Página
1212
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.13.- C13
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo (cm) Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
Disp. Arm. (%) (%) Disp. S. Cap. (%) Naturaleza Comp. (kN) (kN·m) (kN·m) (kN) (kN)
G, S
(3)
Q S. 79.9 33.1 -8.1 28.5 121.1
Cabeza Cumple Cumple 52.9 39.8 Cumple Cumple 52.9 Cumple
G, S
(4)
N,M S. 94.1 -32.8 9.3 -28.4 -120.4
Cumbrera Cubierta (6.6 - 9.47 m) 30x30 8.57 m Cumple Cumple 56.2 79.8 Cumple Cumple 79.8 G, CV, S Q S.,N,M S. 111.3 -68.3 15.9 28.7 121.9 Cumple
(5)
7.1 m Cumple Cumple 64.1 79.8 Cumple Cumple 79.8 G, CV, S Q S.,N,M S. 111.3 -68.3 15.9 28.7 121.9 Cumple
(5)
Pie Cumple Cumple 56.2 79.8 Cumple Cumple 79.8 G, CV, S Q S.,N,M S. 111.3 -68.3 15.9 28.7 121.9 Cumple
(5)
6.6 m N.P.(1) N.P.(1) N.P.(2) 77.0 N.P.(1) Cumple 77.0 G, CV, S(5) N,M S. 111.3 -68.3 15.9 28.7 121.9 Cumple
Cabeza Cumple Cumple 33.5 45.2 Cumple Cumple 45.2 G, CV, S Q S.,N,M S. 123.1 -40.0 8.3 -12.4 -73.2 Cumple
(6)
Pie Cumple Cumple 33.4 47.8 Cumple Cumple 47.8 G, CV, S Q S.,N,M S. 130.6 39.9 -11.5 -12.4 -73.2 Cumple
(6)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
0.9·PP+0.9·CM+0.3·SX2-SY2
(4)
1.2·PP+1.2·CM-0.3·SX2+SY2
(5)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX2-SY2
(6)
1.2·PP+1.2·CM+0.5·Qa-0.3·SX2+SY2
(7)
1.2·PP+1.2·CM+0.5·Qa-SX2+0.3·SY2
Página
1313
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.14.- C14
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S Q S. 55.6 0.0 9.5 -17.7 -2.0
(3)
Cabeza Cumple Cumple 41.7 71.9 Cumple Cumple 71.9 G, CV, S Q S.,N,M S. 127.0 -31.8 -81.2 118.3 -37.0 Cumple
(7)
Cimentación 35x35 Desplantes N.P. N.P. N.P. 78.5 N.P. Cumple 78.5 G, CV, S N,M S. 346.1 29.1 -84.7 -114.8 -34.4 Cumple
(1) (1) (2) (1) (8)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
0.9·PP+0.9·CM-SX1+0.3·SY1
(4)
1.2·PP+1.2·CM+SX1-0.3·SY1
(5)
0.9·PP+0.9·CM+SX1-0.3·SY1
(6)
1.2·PP+1.2·CM+0.5·Qa+SX1-0.3·SY1
(7)
1.2·PP+1.2·CM+0.5·Qa+SX1+0.3·SY1
(8)
1.2·PP+1.2·CM+0.5·Qa-SX1+0.3·SY1
Página
1414
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.15.- C15
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S Q S. 40.0 0.0 -10.8 17.2 2.1
(3)
Cumbrera Cubierta (6.6 - 12.068 m) 35x35 10.812 m Cumple Cumple 28.9 21.9 Cumple Cumple 28.9 G, S Q S.,N,M S. 50.1 -3.6 19.3 17.2 2.1 Cumple
(3)
7.442 m Cumple Cumple 28.9 21.9 Cumple Cumple 28.9 G, S Q S.,N,M S. 50.1 -3.6 19.3 17.2 2.1 Cumple
(3)
Pie Cumple Cumple 28.9 21.9 Cumple Cumple 28.9 G, S Q S.,N,M S. 50.1 -3.6 19.3 17.2 2.1 Cumple
(3)
3.4 m N.P. N.P. N.P. 74.4 N.P. Cumple 74.4 G, CV, S N,M S. 100.2 -14.3 -72.1 -140.7 28.3 Cumple
(1) (1) (2) (1) (7)
Cimentación 35x35 Desplantes N.P. N.P. N.P. 56.4 N.P. Cumple 56.4 N,M S. 85.1 13.5 -53.5 -72.3 -18.6 Cumple
(1) (1) (2) (1)
G, S
(6)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
0.9·PP+0.9·CM+SX1-0.3·SY1
(4)
1.2·PP+1.2·CM+SX1-0.3·SY1
(5)
1.2·PP+1.2·CM+0.5·Qa-SX1+0.3·SY1
(6)
0.9·PP+0.9·CM-SX1+0.3·SY1
(7)
1.2·PP+1.2·CM+0.5·Qa-SX1-0.3·SY1
(8)
0.9·PP+0.9·CM-SX1-0.3·SY1
Página
1515
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.16.- C16
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo (cm) Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
Disp. Arm. (%) (%) Disp. S. Cap. (%) Naturaleza Comp. (kN) (kN·m) (kN·m) (kN) (kN)
G, CV, S Q S. 92.5 2.5 28.8 -80.2 -10.4
(3)
5.7 m Cumple Cumple 45.0 71.5 Cumple Cumple 71.5 G, CV, S Q S.,N,M S. 144.3 43.4 -13.0 16.1 89.4 Cumple
(7)
Entrepiso (-1.2 - 3.4 m) 35x35 2.3 m Cumple Cumple 38.2 93.2 Cumple Cumple 93.2 G, S(8) Q S.,N,M S. 218.5 -84.1 24.6 26.4 109.8 Cumple
-0.5 m Cumple Cumple 69.9 93.2 Cumple Cumple 93.2 G, S(8) Q S.,N,M S. 218.5 -84.1 24.6 26.4 109.8 Cumple
Pie Cumple Cumple 38.2 93.2 Cumple Cumple 93.2 G, S
(8)
Q S.,N,M S. 218.5 -84.1 24.6 26.4 109.8 Cumple
Cimentación 35x35 Desplantes N.P. N.P. N.P. 93.2 N.P. Cumple 93.2 G, S(8) N,M S. 218.5 -84.1 24.6 26.4 109.8 Cumple
(1) (1) (2) (1)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM+0.5·Qa-SX1+0.3·SY1
(4)
1.2·PP+1.2·CM-SX1-0.3·SY1
(5)
0.9·PP+0.9·CM-SX1+0.3·SY1
(6)
1.2·PP+1.2·CM+0.5·Qa-SX2-0.3·SY2
(7)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX1-SY1
(8)
0.9·PP+0.9·CM+0.3·SX1-SY1
Página
1616
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.17.- C17
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S
(3)
Q S. 72.2 30.7 -7.2 25.0 111.0
Cabeza Cumple Cumple 48.5 39.3 Cumple Cumple 48.5 Cumple
G, CV, S N,M S. 112.7 -11.9 29.3 -96.1 -41.8
(4)
6.6 m N.P. N.P. N.P. 70.8 N.P. Cumple 70.8 G, CV, S N,M S. 106.3 58.5 19.5 34.4 -106.6 Cumple
(1) (1) (2) (1) (6)
G, S
(3)
Q S. 87.0 37.1 -0.6 8.0 83.5
Cabeza Cumple Cumple 37.7 45.4 Cumple Cumple 45.4 Cumple
G, CV, S N,M S. 144.7 -36.9 11.5 -18.0 -82.7
(5)
Página
1717
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.18.- C18
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S
(3)
Q S. 73.9 31.9 -6.1 20.5 113.3
Cabeza Cumple Cumple 49.2 41.6 Cumple Cumple 49.2 Cumple
G, CV, S N,M S. 105.2 30.3 13.5 -44.0 106.6
(4)
G, S (5)
Q S. 84.7 -59.6 -21.4 -40.7 108.3
8.57 m Cumple Cumple 52.2 77.2 Cumple Cumple 77.2 Cumple
G, S
(6)
N,M S. 111.7 -58.7 -23.0 -44.1 106.5
Cumbrera Cubierta (6.6 - 9.47 m) 30x30
G, S
(5)
Q S. 84.7 -59.6 -21.4 -40.7 108.3
7.1 m Cumple Cumple 59.5 77.2 Cumple Cumple 77.2 Cumple
G, S
(6)
N,M S. 111.7 -58.7 -23.0 -44.1 106.5
G, S
(5)
Q S. 84.7 -59.6 -21.4 -40.7 108.3
Pie Cumple Cumple 52.2 77.2 Cumple Cumple 77.2 Cumple
G, S(6) N,M S. 111.7 -58.7 -23.0 -44.1 106.5
6.6 m N.P. N.P. N.P. 74.5 N.P. Cumple 74.5 N,M S. 111.7 -58.7 -23.0 -44.1 106.5 Cumple
(1) (1) (2) (1)
G, S
(6)
G, S
(7)
Q S. 106.0 -37.1 10.9 -17.6 -80.2
Cabeza Cumple Cumple 36.7 46.7 Cumple Cumple 46.7 Cumple
G, CV, S N,M S. 139.7 -37.4 12.6 -19.2 -80.6
(8)
Página
1818
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.19.- C19
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S
(3)
Q S. 81.7 -32.4 -11.8 47.6 -111.0
Cabeza Cumple Cumple 51.2 47.1 Cumple Cumple 51.2 Cumple
G, S
(4)
N,M S. 127.8 -15.6 33.9 -105.7 -45.8
G, S (3)
Q S. 86.6 61.1 25.5 47.6 -111.0
8.57 m Cumple Cumple 54.5 83.3 Cumple Cumple 83.3 Cumple
G, CV, S(5) N,M S. 121.5 -58.3 -30.1 -55.5 106.2
Cumbrera Cubierta (6.6 - 9.47 m) 30x30
G, S
(3)
Q S. 86.6 61.1 25.5 47.6 -111.0
7.1 m Cumple Cumple 62.1 83.3 Cumple Cumple 83.3 Cumple
G, CV, S N,M S. 121.5 -58.3 -30.1 -55.5 106.2
(5)
G, S
(3)
Q S. 86.6 61.1 25.5 47.6 -111.0
Pie Cumple Cumple 54.5 83.3 Cumple Cumple 83.3 Cumple
G, CV, S N,M S. 121.5 -58.3 -30.1 -55.5 106.2
(5)
6.6 m N.P. N.P. N.P. 80.3 N.P. Cumple 80.3 G, CV, S N,M S. 121.5 -58.3 -30.1 -55.5 106.2 Cumple
(1) (1) (2) (1) (5)
G, S
(6)
Q S. 124.6 -38.8 12.6 -20.7 -86.4
Cabeza Cumple Cumple 39.3 50.0 Cumple Cumple 50.0 Cumple
G, CV, S N,M S. 159.9 -38.9 14.2 -22.4 -86.9
(7)
Página
1919
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.20.- C20
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S
(3)
Q S. 71.2 20.1 46.8 -117.3 34.3
Cabeza Cumple Cumple 54.3 65.4 Cumple Cumple 65.4 Cumple
G, CV, S N,M S. 79.3 36.6 33.5 -69.0 94.6
(4)
G, S (3)
Q S. 77.8 -20.2 -70.3 -117.3 34.3
8.57 m Cumple Cumple 55.5 90.9 Cumple Cumple 90.9 Cumple
G, S
(5)
N,M S. 85.9 -53.6 -43.9 -69.0 94.7
Cumbrera Cubierta (6.6 - 9.47 m) 30x30
G, S
(3)
Q S. 77.8 -20.2 -70.3 -117.3 34.3
7.1 m Cumple Cumple 63.3 90.9 Cumple Cumple 90.9 Cumple
G, S
(5)
N,M S. 85.9 -53.6 -43.9 -69.0 94.7
G, S
(3)
Q S. 77.8 -20.2 -70.3 -117.3 34.3
Pie Cumple Cumple 55.5 90.9 Cumple Cumple 90.9 Cumple
G, S(5) N,M S. 85.9 -53.6 -43.9 -69.0 94.7
6.6 m N.P. N.P. N.P. 87.5 N.P. Cumple 87.5 N,M S. 85.9 -53.6 -43.9 -69.0 94.7 Cumple
(1) (1) (2) (1)
G, S
(5)
G, S
(6)
Q S. 31.5 -16.2 10.6 -20.8 -37.0
Cabeza Cumple Cumple 76.9 28.8 Cumple Cumple 76.9 Cumple
G, CV, S N,M S. 129.6 21.0 -9.3 17.4 45.4
(7)
Página
2020
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.21.- C21
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo (cm) Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
Disp. Arm. (%) (%) Disp. S. Cap. (%) Naturaleza Comp. (kN) (kN·m) (kN·m) (kN) (kN)
G, S
(3)
Q S. 59.8 -0.2 16.4 -27.9 2.7
Cabeza Cumple Cumple 43.0 18.2 Cumple Cumple 43.0 Cumple
G, S
(4)
N,M S. 115.5 0.1 -17.6 29.0 -2.7
Cumbrera Cubierta (6.6 - 11.985 m) 35x35 10.718 m Cumple Cumple 47.7 34.2 Cumple Cumple 47.7 G, S
(5)
Q S.,N,M S. 103.8 4.5 31.7 28.8 -2.7 Cumple
7.444 m Cumple Cumple 47.7 34.2 Cumple Cumple 47.7 G, S
(5)
Q S.,N,M S. 103.8 4.5 31.7 28.8 -2.7 Cumple
Pie Cumple Cumple 47.7 34.2 Cumple Cumple 47.7 G, S(5) Q S.,N,M S. 103.8 4.5 31.7 28.8 -2.7 Cumple
Cabeza Cumple Cumple 69.4 90.3 Cumple Cumple 90.3 G, CV, S(6) Q S.,N,M S. 99.7 18.9 -96.0 192.7 38.5 Cumple
5.7 m Cumple Cumple 69.3 91.4 Cumple Cumple 91.4 G, CV, S Q S.,N,M S. 109.8 -18.2 97.7 192.7 38.5 Cumple
(6)
Pie Cumple Cumple 69.3 91.4 Cumple Cumple 91.4 G, CV, S Q S.,N,M S. 109.8 -18.2 97.7 192.7 38.5 Cumple
(6)
3.4 m N.P.(1) N.P.(1) N.P.(2) 89.0 N.P.(1) Cumple 89.0 G, CV, S(6) N,M S. 109.8 -18.2 97.7 192.7 38.5 Cumple
G, S
(7)
Q S. 65.4 21.4 -77.6 115.0 33.1
Cabeza Cumple Cumple 43.2 76.6 Cumple Cumple 76.6 Cumple
G, CV, S N,M S. 154.9 22.0 -80.9 116.5 33.4
(6)
G, S
(8)
Q S. 146.2 -26.2 90.3 116.1 33.3
Pie Cumple Cumple 43.4 87.9 Cumple Cumple 87.9 Cumple
G, CV, S N,M S. 170.0 -26.4 91.0 116.5 33.4
(6)
Cimentación 35x35 Desplantes N.P. N.P. N.P. 87.9 N.P. Cumple 87.9 G, CV, S N,M S. 170.0 -26.4 91.0 116.5 33.4 Cumple
(1) (1) (2) (1) (6)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
0.9·PP+0.9·CM-SX2-0.3·SY2
(4)
1.2·PP+1.2·CM+SX2+0.3·SY2
(5)
0.9·PP+0.9·CM+SX2+0.3·SY2
(6)
1.2·PP+1.2·CM+0.5·Qa+SX2-0.3·SY2
(7)
0.9·PP+0.9·CM+SX2-0.3·SY2
(8)
1.2·PP+1.2·CM+SX2-0.3·SY2
Página
2121
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.22.- C22
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S Q S. 41.2 0.0 -11.4 18.7 -2.2
(3)
Cumbrera Cubierta (6.6 - 12.068 m) 35x35 10.812 m Cumple Cumple 31.5 24.2 Cumple Cumple 31.5 G, S Q S.,N,M S. 51.3 3.5 21.2 18.7 -2.2 Cumple
(3)
7.442 m Cumple Cumple 31.5 24.2 Cumple Cumple 31.5 G, S Q S.,N,M S. 51.3 3.5 21.2 18.7 -2.2 Cumple
(3)
Pie Cumple Cumple 31.5 24.2 Cumple Cumple 31.5 G, S Q S.,N,M S. 51.3 3.5 21.2 18.7 -2.2 Cumple
(3)
3.4 m N.P. N.P. N.P. 78.2 N.P. Cumple 78.2 G, CV, S N,M S. 79.2 -14.1 -74.7 -146.8 30.4 Cumple
(1) (1) (2) (1) (5)
Cimentación 35x35 Desplantes N.P. N.P. N.P. 59.9 N.P. Cumple 59.9 N,M S. 50.3 13.4 -55.5 -75.2 -18.0 Cumple
(1) (1) (2) (1)
G, S
(8)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
0.9·PP+0.9·CM+SX2+0.3·SY2
(4)
1.2·PP+1.2·CM+SX2+0.3·SY2
(5)
1.2·PP+1.2·CM+0.5·Qa-SX2-0.3·SY2
(6)
0.9·PP+0.9·CM-SX2-0.3·SY2
(7)
1.2·PP+1.2·CM+0.5·Qa-SX2+0.3·SY2
(8)
0.9·PP+0.9·CM-SX2+0.3·SY2
Página
2222
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.23.- C23
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo (cm) Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
Disp. Arm. (%) (%) Disp. S. Cap. (%) Naturaleza Comp. (kN) (kN·m) (kN·m) (kN) (kN)
Cabeza Cumple Cumple 39.4 48.6 Cumple Cumple 48.6 G, CV, S Q S.,N,M S. 92.9 -3.6 30.5 -84.6 12.8 Cumple
(3)
8.57 m Cumple Cumple 40.3 85.2 Cumple Cumple 85.2 G, CV, S Q S.,N,M S. 99.5 -14.7 -47.9 -84.6 12.8 Cumple
(3)
Pie Cumple Cumple 40.3 85.2 Cumple Cumple 85.2 G, CV, S Q S.,N,M S. 99.5 -14.7 -47.9 -84.6 12.8 Cumple
(3)
6.6 m N.P.(1) N.P.(1) N.P.(2) 66.8 N.P.(1) Cumple 66.8 G, CV, S(3) N,M S. 99.5 -14.7 -47.9 -84.6 12.8 Cumple
G, S
(4)
Q S. 109.7 42.5 -10.9 13.0 87.7
Cabeza Cumple Cumple 42.0 61.3 Cumple Cumple 61.3 Cumple
G, CV, S N,M S. 143.7 42.8 -13.2 15.0 88.2
(5)
G, S
(4)
Q S. 109.7 42.5 -10.9 13.0 87.7
5.7 m Cumple Cumple 47.8 61.3 Cumple Cumple 61.3 Cumple
G, CV, S N,M S. 143.7 42.8 -13.2 15.0 88.2
(5)
Cubierta (3.4 - 6.6 m) 30x30
G, S(4) Q S. 109.7 42.5 -10.9 13.0 87.7
3.9 m Cumple Cumple 42.0 61.3 Cumple Cumple 61.3 Cumple
G, CV, S N,M S. 143.7 42.8 -13.2 15.0 88.2
(5)
G, S
(4)
Q S. 203.9 69.6 -18.7 24.3 109.6
Cabeza Cumple Cumple 39.6 70.3 Cumple Cumple 70.3 Cumple
G, CV, S N,M S. 295.2 70.0 -22.0 25.6 110.1
(5)
G, S
(4)
Q S. 215.3 -84.0 22.7 24.3 109.6
2.3 m Cumple Cumple 40.0 83.4 Cumple Cumple 83.4 Cumple
G, CV, S(5) N,M S. 310.4 -84.5 24.4 25.6 110.1
Entrepiso (-1.2 - 3.4 m) 35x35
G, S(4) Q S. 215.3 -84.0 22.7 24.3 109.6
-0.5 m Cumple Cumple 72.7 83.4 Cumple Cumple 83.4 Cumple
G, CV, S(5) N,M S. 310.4 -84.5 24.4 25.6 110.1
G, S
(4)
Q S. 215.3 -84.0 22.7 24.3 109.6
Pie Cumple Cumple 40.0 83.4 Cumple Cumple 83.4 Cumple
G, CV, S(5) N,M S. 310.4 -84.5 24.4 25.6 110.1
Cimentación 35x35 Desplantes N.P.(1) N.P.(1) N.P.(2) 83.4 N.P.(1) Cumple 83.4 G, CV, S(5) N,M S. 310.4 -84.5 24.4 25.6 110.1 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM+0.5·Qa-SX2-0.3·SY2
(4)
0.9·PP+0.9·CM+0.3·SX1-SY1
(5)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX1-SY1
Página
2323
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.24.- C24
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S Q S. 45.0 0.1 10.7 -20.7 2.3
(3)
Cumbrera Cubierta (6.6 - 11.974 m) 35x35 10.727 m Cumple Cumple 35.8 26.0 Cumple Cumple 35.8 G, S Q S.,N,M S. 90.8 3.5 25.1 21.6 -2.2 Cumple
(5)
7.425 m Cumple Cumple 35.8 26.0 Cumple Cumple 35.8 G, S Q S.,N,M S. 90.8 3.5 25.1 21.6 -2.2 Cumple
(5)
Pie Cumple Cumple 35.8 26.0 Cumple Cumple 35.8 G, S Q S.,N,M S. 90.8 3.5 25.1 21.6 -2.2 Cumple
(5)
Cabeza Cumple Cumple 48.0 78.3 Cumple Cumple 78.3 G, CV, S Q S.,N,M S. 100.7 21.9 -98.3 138.0 34.2 Cumple
(6)
Cimentación 35x35 Desplantes N.P. N.P. N.P. 87.0 N.P. Cumple 87.0 G, CV, S N,M S. 445.2 25.8 -94.7 -131.4 -34.0 Cumple
(1) (1) (2) (1) (8)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
0.9·PP+0.9·CM-SX2-0.3·SY2
(4)
1.2·PP+1.2·CM+0.5·Qa+SX2+0.3·SY2
(5)
0.9·PP+0.9·CM+SX2+0.3·SY2
(6)
1.2·PP+1.2·CM+0.5·Qa+SX2-0.3·SY2
(7)
0.9·PP+0.9·CM+SX2-0.3·SY2
(8)
1.2·PP+1.2·CM+0.5·Qa-SX2+0.3·SY2
Página
2424
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.25.- C25
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
Cabeza Cumple Cumple 49.4 23.5 Cumple Cumple 49.4 G, S Q S.,N,M S. 33.3 0.2 -20.0 30.1 -2.9 Cumple
(3)
Cumbrera Cubierta (6.6 - 12.077 m) 35x35 G, CV, S Q S. 68.1 4.7 33.3 30.4 -2.9
(4)
Cabeza Cumple Cumple 75.0 96.9 Cumple Cumple 96.9 G, CV, S Q S.,N,M S. 68.0 -16.7 101.5 -209.0 -33.6 Cumple
(5)
5.7 m Cumple Cumple 86.1 96.9 Cumple Cumple 96.9 G, CV, S Q S.,N,M S. 68.0 -16.7 101.5 -209.0 -33.6 Cumple
(5)
3.9 m Cumple Cumple 75.0 96.9 Cumple Cumple 96.9 G, CV, S Q S.,N,M S. 68.0 -16.7 101.5 -209.0 -33.6 Cumple
(5)
Cubierta (3.4 - 6.6 m) 35x35
G, CV, S Q S. 78.0 13.9 -105.9 -209.0 -33.6
(5)
3.4 m N.P. N.P. N.P. 96.7 N.P. Cumple 96.7 N,M S. 46.3 14.1 -101.7 -206.1 -33.6 Cumple
(1) (1) (2) (1)
G, S
(6)
Cabeza Cumple Cumple 48.0 88.9 Cumple Cumple 88.9 G, CV, S Q S.,N,M S. 93.7 -17.3 92.9 -131.5 -28.7 Cumple
(5)
Entrepiso (-1.2 - 3.4 m) 35x35 -0.5 m Cumple Cumple 55.4 96.6 Cumple Cumple 96.6 Cumple
G, CV, S N,M S. 111.4 -24.2 -98.9 -127.4 30.5
(7)
Cimentación 35x35 Desplantes N.P. N.P. N.P. 96.6 N.P. Cumple 96.6 G, CV, S N,M S. 111.4 -24.2 -98.9 -127.4 30.5 Cumple
(1) (1) (2) (1) (7)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
0.9·PP+0.9·CM+SX2+0.3·SY2
(4)
1.2·PP+1.2·CM+0.5·Qa+SX2+0.3·SY2
(5)
1.2·PP+1.2·CM+0.5·Qa-SX2+0.3·SY2
(6)
0.9·PP+0.9·CM-SX2+0.3·SY2
(7)
1.2·PP+1.2·CM+0.5·Qa-SX2-0.3·SY2
Pie Cumple Cumple G(1) 98.6 -0.7 2.1 0.8 0.2 Cumple
Cabeza Cumple Cumple G 137.1 0.3 7.4 -7.1 0.4 Cumple
(1)
Pie Cumple Cumple G(1) 148.9 -0.8 -12.4 -7.1 0.4 Cumple
Cabeza Cumple Cumple G 270.7 0.6 10.3 -3.9 0.2 Cumple
(1)
Cimentación 35x35 - - - - - - - - - -
Notas:
(1)
1.4·PP+1.4·CM
Página
2525
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.26.- C26
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo (cm) Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
Disp. Arm. (%) (%) Disp. S. Cap. (%) Naturaleza Comp. (kN) (kN·m) (kN·m) (kN) (kN)
Cabeza Cumple Cumple 43.9 53.8 Cumple Cumple 53.8 G, CV, S Q S.,N,M S. 92.1 -3.7 33.3 -94.3 13.6 Cumple
(3)
G, S
(5)
Q S. 205.2 -83.8 20.8 22.8 109.0
Pie Cumple Cumple 39.8 86.0 Cumple Cumple 86.0 Cumple
G, CV, S N,M S. 362.0 30.1 79.7 91.0 -39.8
(8)
Cimentación 35x35 Desplantes N.P.(1) N.P.(1) N.P.(2) 86.0 N.P.(1) Cumple 86.0 G, CV, S(8) N,M S. 362.0 30.1 79.7 91.0 -39.8 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM+0.5·Qa-SX2-0.3·SY2
(4)
1.2·PP+1.2·CM-SX2-0.3·SY2
(5)
0.9·PP+0.9·CM+0.3·SX1-SY1
(6)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX1-SY1
(7)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX1+SY1
(8)
1.2·PP+1.2·CM+0.5·Qa+SX2+0.3·SY2
Página
2626
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.27.- C27
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S Q S. 61.8 -0.5 12.1 -21.9 1.8
(3)
Pie Cumple Cumple 53.7 78.6 Cumple Cumple 78.6 G, CV, S Q S.,N,M S. 133.8 -10.1 73.5 148.2 24.9 Cumple
(6)
Cabeza Cumple Cumple 54.6 85.0 Cumple Cumple 85.0 G, CV, S Q S.,N,M S. 156.2 20.3 -103.8 146.2 34.3 Cumple
(6)
Cimentación 35x35 Desplantes N.P. N.P. N.P. 96.8 N.P. Cumple 96.8 G, CV, S N,M S. 449.2 27.8 -100.9 -139.4 -35.9 Cumple
(1) (1) (2) (1) (8)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
0.9·PP+0.9·CM-SX2-0.3·SY2
(4)
1.2·PP+1.2·CM+0.5·Qa+SX2+0.3·SY2
(5)
1.2·PP+1.2·CM+SX2+0.3·SY2
(6)
1.2·PP+1.2·CM+0.5·Qa+SX2-0.3·SY2
(7)
0.9·PP+0.9·CM+SX2-0.3·SY2
(8)
1.2·PP+1.2·CM+0.5·Qa-SX2+0.3·SY2
Página
2727
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.28.- C28
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, S Q S. 46.9 -0.3 -13.3 21.9 -2.2
(3)
Cumbrera Cubierta (6.6 - 12.068 m) 35x35 10.812 m Cumple Cumple 36.9 28.1 Cumple Cumple 36.9 G, S Q S.,N,M S. 56.9 3.6 24.5 21.9 -2.2 Cumple
(3)
7.442 m Cumple Cumple 36.9 28.1 Cumple Cumple 36.9 G, S Q S.,N,M S. 56.9 3.6 24.5 21.9 -2.2 Cumple
(3)
Pie Cumple Cumple 36.9 28.1 Cumple Cumple 36.9 G, S Q S.,N,M S. 56.9 3.6 24.5 21.9 -2.2 Cumple
(3)
Cabeza Cumple Cumple 54.6 80.3 Cumple Cumple 80.3 G, CV, S Q S.,N,M S. 128.8 -12.6 74.4 -150.5 -25.7 Cumple
(5)
5.7 m Cumple Cumple 89.0 80.3 Cumple Cumple 89.0 G, CV, S Q S.,N,M S. 128.8 -12.6 74.4 -150.5 -25.7 Cumple
(5)
Pie Cumple Cumple 54.5 79.0 Cumple Cumple 79.0 G, CV, S Q S.,N,M S. 136.2 12.5 -74.1 -150.5 -25.7 Cumple
(5)
Cabeza Cumple Cumple 55.6 89.0 Cumple Cumple 89.0 G, CV, S Q S.,N,M S. 160.8 -22.9 107.1 -149.0 -32.8 Cumple
(5)
2.3 m Cumple Cumple 55.7 94.9 Cumple Cumple 94.9 G, CV, S Q S.,N,M S. 175.9 25.2 -113.4 -149.0 -32.8 Cumple
(5)
Pie Cumple Cumple 55.7 94.9 Cumple Cumple 94.9 G, CV, S Q S.,N,M S. 175.9 25.2 -113.4 -149.0 -32.8 Cumple
(5)
Cimentación 35x35 Desplantes N.P. N.P. N.P. 94.9 N.P. Cumple 94.9 G, CV, S N,M S. 175.9 25.2 -113.4 -149.0 -32.8 Cumple
(1) (1) (2) (1) (5)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
0.9·PP+0.9·CM+SX2+0.3·SY2
(4)
1.2·PP+1.2·CM+0.5·Qa-SX2-0.3·SY2
(5)
1.2·PP+1.2·CM+0.5·Qa-SX2+0.3·SY2
Página
2828
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.29.- C29
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo (cm) Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
Disp. Arm. (%) (%) Disp. S. Cap. (%) Naturaleza Comp. (kN) (kN·m) (kN·m) (kN) (kN)
Cabeza Cumple Cumple 68.6 45.5 Cumple Cumple 68.6 G, CV, S Q S.,N,M S. 154.5 -58.6 -10.5 57.9 -193.3 Cumple
(3)
Pie Cumple Cumple 37.9 42.2 Cumple Cumple 42.2 G, CV, S Q S.,N,M S. 79.5 -56.2 15.3 17.4 110.1 Cumple
(5)
G, S
(6)
Q S. 135.8 -83.7 18.5 20.4 109.9
2.3 m Cumple Cumple 38.4 78.4 Cumple Cumple 78.4 Cumple
G, CV, S N,M S. 391.0 32.1 82.7 94.6 -41.9
(7)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX1+SY1
(4)
1.2·PP+1.2·CM+0.3·SX1+SY1
(5)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX1-SY1
(6)
0.9·PP+0.9·CM+0.3·SX1-SY1
(7)
1.2·PP+1.2·CM+0.5·Qa+SX2+0.3·SY2
Página
2929
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.30.- C30
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, CV, S (3)
Q S. 43.7 6.9 -27.2 81.8 13.8
Cabeza Cumple Cumple 28.5 38.5 Cumple Cumple 38.5 Cumple
G, S N,M S. -7.2 -2.4 24.7 -77.8 -6.5
(4)
Cubierta (3.4 - 6.6 m) 35x35 5.7 m Cumple Cumple 29.1 73.0 Cumple Cumple 73.0 G, CV, S
(3)
Q S.,N,M S. 51.1 -14.3 53.1 81.8 13.8 Cumple
3.9 m Cumple Cumple 53.9 73.0 Cumple Cumple 73.0 G, CV, S(3) Q S.,N,M S. 51.1 -14.3 53.1 81.8 13.8 Cumple
Pie Cumple Cumple 29.1 73.0 Cumple Cumple 73.0 G, CV, S Q S.,N,M S. 51.1 -14.3 53.1 81.8 13.8 Cumple
(3)
-0.5 m Cumple Cumple 66.7 76.8 Cumple Cumple 76.8 G, CV, S Q S.,N,M S. 40.3 -31.6 117.0 157.7 33.9 Cumple
(3)
Pie Cumple Cumple 58.2 76.8 Cumple Cumple 76.8 G, CV, S(3) Q S.,N,M S. 40.3 -31.6 117.0 157.7 33.9 Cumple
Cimentación 35x35 Desplantes N.P. N.P. N.P. 76.8 N.P. Cumple 76.8 G, CV, S N,M S. 40.3 -31.6 117.0 157.7 33.9 Cumple
(1) (1) (2) (1) (3)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM+0.5·Qa+SX2-0.3·SY2
(4)
0.9·PP+0.9·CM-SX2+0.3·SY2
(5)
0.9·PP+0.9·CM+SX2-0.3·SY2
2.31.- C31
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Disp. S. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kN·m) (kN·m) (kN) (kN)
G, CV, S Q S. 36.9 -1.2 27.6 -84.6 -4.2
(3)
3.9 m Cumple Cumple 55.0 74.7 Cumple Cumple 74.7 G, CV, S Q S.,N,M S. 44.3 -5.6 -55.0 -84.6 -4.2 Cumple
(3)
Pie Cumple Cumple 29.7 74.7 Cumple Cumple 74.7 G, CV, S(3) Q S.,N,M S. 44.3 -5.6 -55.0 -84.6 -4.2 Cumple
G, S
(5)
Q S. -28.9 -5.4 111.9 -160.9 -21.7
Cabeza Cumple Cumple 61.3 70.7 Cumple Cumple 70.7 Cumple
G, CV, S(6) N,M S. 31.7 30.4 108.3 -153.0 32.3
G, S
(5)
Q S. -17.5 15.5 -119.2 -160.9 -21.7
2.3 m Cumple Cumple 60.9 77.3 Cumple Cumple 77.3 Cumple
G, CV, S N,M S. 195.4 -29.2 111.3 156.5 30.8
(7)
Cimentación 35x35 Desplantes N.P. N.P. N.P. 77.3 N.P. Cumple 77.3 G, CV, S N,M S. 195.4 -29.2 111.3 156.5 30.8 Cumple
(1) (1) (2) (1) (7)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM+0.5·Qa-SX2+0.3·SY2
(4)
0.9·PP+0.9·CM+SX2+0.3·SY2
(5)
0.9·PP+0.9·CM-SX2+0.3·SY2
(6)
1.2·PP+1.2·CM+0.5·Qa-SX2-0.3·SY2
(7)
1.2·PP+1.2·CM+0.5·Qa+SX2-0.3·SY2
Página
3030
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
2.32.- C32
Sección de hormigón - Temperatura ambiente
Comprobaciones Esfuerzos pésimos
Tramo Dimensión Posición Estado
(cm) Q N,M Aprov. N Mxx Myy Qx Qy
Disp. Arm. (%) (%) Disp. S. Cap. (%) Naturaleza Comp. (kN) (kN·m) (kN·m) (kN) (kN)
G, S(3)
Q S. 126.4 80.7 -34.0 10.5 229.2
Cabeza Cumple Cumple 66.6 59.9 Cumple Cumple 66.6 Cumple
G, CV, S(4) N,M S. 126.4 80.8 -34.0 10.4 229.1
Cumbrera Cubierta (6.6 - 9.992 m) 40x40 8.57 m Cumple Cumple 68.4 97.8 Cumple Cumple 97.8 G, S
(3)
Q S.,N,M S. 138.0 -142.2 14.4 10.5 229.2 Cumple
7.1 m Cumple Cumple 87.2 97.8 Cumple Cumple 97.8 G, S(3) Q S.,N,M S. 138.0 -142.2 14.4 10.5 229.2 Cumple
Pie Cumple Cumple 68.4 97.8 Cumple Cumple 97.8 G, S(3) Q S.,N,M S. 138.0 -142.2 14.4 10.5 229.2 Cumple
6.6 m N.P.(1) N.P.(1) N.P.(2) 97.8 N.P.(1) Cumple 97.8 G, S(3) N,M S. 138.0 -142.2 14.4 10.5 229.2 Cumple
G, CV, S(5) Q S. 38.4 -1.6 25.2 -20.1 8.6
Cabeza Cumple Cumple 26.7 16.9 Cumple Cumple 26.7 Cumple
G, S(6) N,M S. 8.3 -0.3 22.4 -18.9 6.3
G, CV, S(5) Q S. 38.4 -1.6 25.2 -20.1 8.6
5.7 m Cumple Cumple 26.7 16.9 Cumple Cumple 26.7 Cumple
Cubierta (3.4 - 6.6 m) 40x40 G, S(6) N,M S. 8.3 -0.3 22.4 -18.9 6.3
G, CV, S(5) Q S. 38.4 -1.6 25.2 -20.1 8.6
3.9 m Cumple Cumple 26.7 16.9 Cumple Cumple 26.7 Cumple
G, S
(6)
N,M S. 8.3 -0.3 22.4 -18.9 6.3
G, CV, S(5) Q S. 51.6 -13.4 2.8 -20.1 8.6
Pie Cumple Cumple 18.1 13.6 Cumple Cumple 18.1 Cumple
G, CV(7) N,M 127.8 -20.9 5.6 -1.5 5.4
G, S
(8)
Q S. 262.3 29.3 -83.4 155.0 31.5
Cabeza Cumple Cumple 45.6 62.9 Cumple Cumple 62.9 Cumple
G, CV, S(9) N,M S. 330.1 84.9 -37.3 61.5 129.7
G, CV, S(10) Q S. 295.4 -32.5 142.0 155.2 32.7
2.3 m Cumple Cumple 47.1 99.4 Cumple Cumple 99.4 Cumple
G, S
(11)
N,M S. 82.9 15.3 -134.8 -149.4 -21.5
Entrepiso (-1.2 - 3.4 m) 40x40
G, CV, S(10) Q S. 295.4 -32.5 142.0 155.2 32.7
-0.5 m Cumple Cumple 60.1 99.4 Cumple Cumple 99.4 Cumple
G, S(11) N,M S. 82.9 15.3 -134.8 -149.4 -21.5
G, CV, S Q S. 295.4 -32.5 142.0 155.2 32.7
(10)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2·PP+1.2·CM+0.3·SX1-SY1
(4)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX1-SY1
(5)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX2+SY2
(6)
0.9·PP+0.9·CM+0.3·SX1+SY1
(7)
1.2·PP+1.2·CM+1.6·Qa
(8)
1.2·PP+1.2·CM+SX2-0.3·SY2
(9)
1.2·PP+1.2·CM+0.5·Qa+0.3·SX2-SY2
(10)
1.2·PP+1.2·CM+0.5·Qa+SX2-0.3·SY2
(11)
0.9·PP+0.9·CM-SX2+0.3·SY2
Página
3131
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
3.- VIGAS
3.1.- Entrepiso
COMPROBACIONES DE RESISTENCIA (NSR-10, TÍTULO C)
Vigas Estado
Disp. Arm. Q Q S. N,M N,M S. Tc Tst Tsl TNMx TVx TVy TVX st TV Yst T,Disp.sl T,Disp.st T,Geom.sl T,Arm.st Disp. S. Cap. S
'0.167 m' '0.582 m' '0.582 m' '0.582 m' '0.582 m' '0.334 m' CUMPLE
V-1001: B37 - C1 Cumple N.P. (1)
N.P. (1)
N.P. (1)
N.P. (2)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
Cumple
Cumple h= 5.7 h= 3.8 h= 23.5 h= 15.7 Cumple h = 23.5
'0.000 m' '0.284 m' '0.284 m' '0.284 m' '0.284 m' '0.284 m' CUMPLE
V-1005: C4 - B42 Cumple N.P. (1) N.P. (1) N.P. (1) N.P. (2) N.P. (1) N.P. (1) N.P. (1) N.P. (1) N.P. (1) N.P. (1) N.P. (1) N.P. (1) Cumple
Cumple h= 5.7 h= 3.8 h= 23.5 h= 15.7 Cumple h = 23.5
'0.732 m' '0.732 m' '0.732 m' '0.732 m' '0.167 m' CUMPLE
V-1006: B39 - B0 Cumple Cumple N.P. (1)
N.P. (1)
N.P. (1)
N.P. (2)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
Cumple
h= 12.8 h= 7.9 h= 71.1 h= 44.3 Cumple h = 71.1
'0.801 m' '0.801 m' '2.400 m' '2.400 m' '0.601 m' '5.399 m' CUMPLE
V-1007: B0 - B2 Cumple Cumple N.P. (1)
N.P. (1)
N.P. (1)
N.P. (2)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
Página
3232
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Página
3333
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple
x: 0 m x: 2.75 m
V-1002: C1 - C2 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.55 m
V-1003: C2 - C3 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
N.P.
x: 5.525 m x: 2.775 m (1)
V-1004: C3 - C4 N.P. CUMPLE
(1)
Cumple Cumple
x: 0.284 m
V-1005: C4 - B42 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1 m
V-1006: B39 - B0 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.6 m x: 0.601 m
V-1007: B0 - B2 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1008: B2 - B3 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 4.999 m
V-1009: B3 - B1 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1010: B1 - B44 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0.666 m
V-1011: B40 - C5 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
Página
3434
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple Cumple
x: 1.55 m
V-1013: C6 - C7 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 2.975 m
V-1014: C7 - C8 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0.334 m
V-1015: C8 - B45 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1 m
V-1016: B41 - B4 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.6 m x: 0.601 m
V-1017: B4 - B6 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.6 m
V-1018: B6 - B7 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 4.999 m
V-1019: B7 - B5 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1020: B5 - B46 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0.666 m
V-1021: B38 - C9 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 2.95 m
V-1022: C9 - C10 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.55 m
V-1023: C10 - C11 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 2.775 m
V-1024: C11 - C12 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0.309 m
V-1025: C12 - B47 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1.6 m
V-1026: B10 - B11 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 4.999 m
V-1027: B11 - B9 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1028: B9 - B48 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1 m
V-1029: B28 - C13 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 2.6 m
V-1030: C13 - C14 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.575 m
V-1031: C14 - C15 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.575 m x: 2.8 m
V-1032: C15 - C16 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0.309 m
V-1033: C16 - B49 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1 m
V-1034: B30 - B12 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.6 m x: 0.601 m
V-1035: B12 - B14 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
Página
3535
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple
x: 0 m x: 4.999 m
V-1037: B15 - B13 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1038: B13 - B50 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0.666 m
V-1039: B31 - C17 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.575 m x: 2.6 m
V-1040: C17 - C21 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.575 m
V-1041: C21 - C22 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.575 m x: 2.8 m
V-1042: C22 - C23 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0.309 m
V-1043: C23 - B51 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1 m
V-1044: B32 - B16 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.6 m x: 0.601 m
V-1045: B16 - B18 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1046: B18 - B19 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 4.999 m
V-1047: B19 - B17 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1048: B17 - B52 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0.666 m
V-1049: B33 - C18 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.575 m x: 2.6 m
V-1050: C18 - C24 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1051: C24 - C25 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 2.775 m
V-1052: C25 - C26 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0.309 m
V-1053: C26 - B53 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1 m
V-1054: B34 - B20 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.6 m x: 0.601 m
V-1055: B20 - B22 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1056: B22 - B23 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 4.999 m
V-1057: B23 - B21 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1058: B21 - B54 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0.666 m
V-1059: B35 - C19 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
Página
3636
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple Cumple
x: 0 m
V-1061: C27 - C28 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.55 m x: 2.775 m
V-1062: C28 - C29 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0.309 m
V-1063: C29 - B55 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1 m
V-1064: B36 - B24 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.6 m x: 0.601 m
V-1065: B24 - B26 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1066: B26 - B27 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 4.999 m
V-1067: B27 - B25 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1068: B25 - B56 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 4.35 m x: 2.209 m
V-1069: C20 - C19 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.233 m
V-1070: C19 - C18 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.35 m x: 2.146 m
V-1071: C18 - C17 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.225 m
V-1072: C17 - C13 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.275 m x: 2.14 m
V-1073: C9 - C5 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.231 m
V-1074: C5 - C1 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.275 m x: 2.159 m
V-1075: C32 - C29 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.208 m
V-1076: C29 - C26 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.121 m
V-1077: C26 - C23 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.2 m
V-1078: C23 - C16 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.196 m
V-1079: C16 - C12 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.165 m
V-1080: C12 - C8 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.256 m
V-1081: C8 - C4 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.059 m
V-1082: C31 - B27 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.991 m x: 0 m
V-1083: B27 - C28 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
Página
3737
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple Cumple
x: 4.325 m x: 2.121 m
V-1085: C25 - C22 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.225 m
V-1086: C22 - C15 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.221 m
V-1087: C15 - C11 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.165 m
V-1088: C11 - C7 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.231 m
V-1089: C7 - C3 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.059 m
V-1090: C30 - B26 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.991 m x: 0 m
V-1091: B26 - C27 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.3 m x: 2.208 m
V-1092: C27 - C24 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.121 m
V-1093: C24 - C21 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.2 m
V-1094: C21 - C14 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 2.196 m
V-1095: C14 - C10 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 4.3 m x: 2.165 m
V-1096: C10 - C6 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.231 m
V-1097: C6 - C2 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0.5 m
V-1098: B29 - C20 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 2.6 m
V-1099: C20 - C30 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1100: C30 - C31 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.525 m x: 2.775 m
V-1101: C31 - C32 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-1102: C32 - B43 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
Notación:
sC,sup.: Comprobación de la separación máxima entre barras: Cara superior
sC,Lat.Der.: Comprobación de la separación máxima entre barras: Cara lateral derecha
sC,inf.: Comprobación de la separación máxima entre barras: Cara inferior
sC,Lat.Izq.: Comprobación de la separación máxima entre barras: Cara lateral izquierda
x: Distancia al origen de la barra
h: Coeficiente de aprovechamiento (%)
N.P.: No procede
Página
3838
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 0.07 mm
V-1001: B37 - C1 fA,lim: 3.96 mm CUMPLE
fA,max: 0.76 mm
V-1002: C1 - C2 fA,lim: 11.51 mm CUMPLE
fA,max: 0.06 mm
V-1003: C2 - C3 fA,lim: 3.23 mm CUMPLE
fA,max: 0.77 mm
V-1004: C3 - C4 fA,lim: 11.51 mm CUMPLE
fA,max: 0.07 mm
V-1005: C4 - B42 fA,lim: 3.96 mm CUMPLE
fA,max: 5.28 mm
V-1006: B39 - B0 fA,lim: 33.33 mm CUMPLE
fA,max: 20.53 mm
V-1007: B0 - B2 fA,lim: 33.33 mm CUMPLE
fA,max: 5.73 mm
V-1008: B2 - B3 fA,lim: 33.33 mm CUMPLE
fA,max: 20.67 mm
V-1009: B3 - B1 fA,lim: 33.33 mm CUMPLE
fA,max: 5.32 mm
V-1010: B1 - B44 fA,lim: 33.33 mm CUMPLE
fA,max: 0.15 mm
V-1011: B40 - C5 fA,lim: 4.06 mm CUMPLE
fA,max: 1.69 mm
V-1012: C5 - C6 fA,lim: 11.56 mm CUMPLE
fA,max: 0.10 mm
V-1013: C6 - C7 fA,lim: 3.23 mm CUMPLE
fA,max: 1.76 mm
V-1014: C7 - C8 fA,lim: 11.61 mm CUMPLE
fA,max: 0.16 mm
V-1015: C8 - B45 fA,lim: 4.17 mm CUMPLE
fA,max: 5.94 mm
V-1016: B41 - B4 fA,lim: 33.33 mm CUMPLE
fA,max: 22.99 mm
V-1017: B4 - B6 fA,lim: 33.33 mm CUMPLE
fA,max: 6.06 mm
V-1018: B6 - B7 fA,lim: 33.33 mm CUMPLE
fA,max: 21.64 mm
V-1019: B7 - B5 fA,lim: 33.33 mm CUMPLE
fA,max: 5.55 mm
V-1020: B5 - B46 fA,lim: 33.33 mm CUMPLE
fA,max: 0.07 mm
V-1021: B38 - C9 fA,lim: 3.96 mm CUMPLE
fA,max: 0.75 mm
V-1022: C9 - C10 fA,lim: 11.51 mm CUMPLE
Página
3939
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 0.06 mm
V-1023: C10 - C11 f : 3.23 mm CUMPLE
A,lim
fA,max: 1.62 mm
V-1024: C11 - C12 f : 11.56 mm CUMPLE
A,lim
fA,max: 0.15 mm
V-1025: C12 - B47 f : 4.06 mm CUMPLE
A,lim
fA,max: 3.04 mm
V-1026: B10 - B11 f : 18.33 mm CUMPLE
A,lim
fA,max: 16.44 mm
V-1027: B11 - B9 fA,lim: 18.33 mm CUMPLE
fA,max: 4.26 mm
V-1028: B9 - B48 fA,lim: 18.33 mm CUMPLE
fA,max: 0.08 mm
V-1029: B28 - C13 f : 4.17 mm CUMPLE
A,lim
fA,max: 0.84 mm
V-1030: C13 - C14 f : 11.61 mm CUMPLE
A,lim
fA,max: 0.08 mm
V-1031: C14 - C15 f : 3.28 mm CUMPLE
A,lim
fA,max: 1.72 mm
V-1032: C15 - C16 f : 11.61 mm CUMPLE
A,lim
fA,max: 0.15 mm
V-1033: C16 - B49 f : 4.06 mm CUMPLE
A,lim
fA,max: 5.80 mm
V-1034: B30 - B12 f : 33.33 mm CUMPLE
A,lim
fA,max: 22.50 mm
V-1035: B12 - B14 f : 33.33 mm CUMPLE
A,lim
fA,max: 5.61 mm
V-1036: B14 - B15 f : 33.33 mm CUMPLE
A,lim
fA,max: 21.82 mm
V-1037: B15 - B13 f : 33.33 mm CUMPLE
A,lim
fA,max: 5.61 mm
V-1038: B13 - B50 f : 33.33 mm CUMPLE
A,lim
fA,max: 0.16 mm
V-1039: B31 - C17 f : 4.17 mm CUMPLE
A,lim
fA,max: 1.75 mm
V-1040: C17 - C21 f : 11.61 mm CUMPLE
A,lim
fA,max: 0.10 mm
V-1041: C21 - C22 f : 3.28 mm CUMPLE
A,lim
fA,max: 1.77 mm
V-1042: C22 - C23 f : 11.61 mm CUMPLE
A,lim
fA,max: 0.15 mm
V-1043: C23 - B51 f : 4.06 mm CUMPLE
A,lim
fA,max: 5.21 mm
V-1044: B32 - B16 f : 33.33 mm CUMPLE
A,lim
Página
4040
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 20.26 mm
V-1045: B16 - B18 f : 33.33 mm CUMPLE
A,lim
fA,max: 5.46 mm
V-1046: B18 - B19 f : 33.33 mm CUMPLE
A,lim
fA,max: 20.56 mm
V-1047: B19 - B17 f : 33.33 mm CUMPLE
A,lim
fA,max: 5.30 mm
V-1048: B17 - B52 f : 33.33 mm CUMPLE
A,lim
fA,max: 0.16 mm
V-1049: B33 - C18 f : 4.17 mm CUMPLE
A,lim
fA,max: 1.66 mm
V-1050: C18 - C24 f : 11.61 mm CUMPLE
A,lim
fA,max: 0.09 mm
V-1051: C24 - C25 f : 3.23 mm CUMPLE
A,lim
fA,max: 1.60 mm
V-1052: C25 - C26 f : 11.56 mm CUMPLE
A,lim
fA,max: 0.14 mm
V-1053: C26 - B53 f : 4.06 mm CUMPLE
A,lim
fA,max: 5.76 mm
V-1054: B34 - B20 f : 33.33 mm CUMPLE
A,lim
fA,max: 22.33 mm
V-1055: B20 - B22 f : 33.33 mm CUMPLE
A,lim
fA,max: 5.80 mm
V-1056: B22 - B23 f : 33.33 mm CUMPLE
A,lim
fA,max: 22.29 mm
V-1057: B23 - B21 f : 33.33 mm CUMPLE
A,lim
fA,max: 5.74 mm
V-1058: B21 - B54 f : 33.33 mm CUMPLE
A,lim
fA,max: 0.16 mm
V-1059: B35 - C19 f : 4.17 mm CUMPLE
A,lim
fA,max: 1.71 mm
V-1060: C19 - C27 f : 11.61 mm CUMPLE
A,lim
fA,max: 0.10 mm
V-1061: C27 - C28 f : 3.23 mm CUMPLE
A,lim
fA,max: 1.63 mm
V-1062: C28 - C29 f : 11.56 mm CUMPLE
A,lim
fA,max: 0.15 mm
V-1063: C29 - B55 f : 4.06 mm CUMPLE
A,lim
fA,max: 5.21 mm
V-1064: B36 - B24 f : 33.33 mm CUMPLE
A,lim
fA,max: 20.26 mm
V-1065: B24 - B26 f : 33.33 mm CUMPLE
A,lim
fA,max: 5.25 mm
V-1066: B26 - B27 f : 33.33 mm CUMPLE
A,lim
Página
4141
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 20.42 mm
V-1067: B27 - B25 f : 33.33 mm CUMPLE
A,lim
fA,max: 5.25 mm
V-1068: B25 - B56 f : 33.33 mm CUMPLE
A,lim
fA,max: 3.35 mm
V-1069: C20 - C19 f : 9.06 mm CUMPLE
A,lim
fA,max: 1.56 mm
V-1070: C19 - C18 f : 9.06 mm CUMPLE
A,lim
fA,max: 1.58 mm
V-1071: C18 - C17 f : 9.06 mm CUMPLE
A,lim
fA,max: 3.38 mm
V-1072: C17 - C13 f : 9.06 mm CUMPLE
A,lim
fA,max: 2.08 mm
V-1073: C9 - C5 fA,lim: 8.91 mm CUMPLE
fA,max: 2.10 mm
V-1074: C5 - C1 fA,lim: 8.91 mm CUMPLE
fA,max: 2.23 mm
V-1075: C32 - C29 f : 8.91 mm CUMPLE
A,lim
fA,max: 1.52 mm
V-1076: C29 - C26 f : 8.96 mm CUMPLE
A,lim
fA,max: 1.64 mm
V-1077: C26 - C23 f : 8.96 mm CUMPLE
A,lim
fA,max: 1.62 mm
V-1078: C23 - C16 f : 8.96 mm CUMPLE
A,lim
fA,max: 1.63 mm
V-1079: C16 - C12 f : 8.96 mm CUMPLE
A,lim
fA,max: 1.60 mm
V-1080: C12 - C8 fA,lim: 9.01 mm CUMPLE
fA,max: 2.27 mm
V-1081: C8 - C4 fA,lim: 8.96 mm CUMPLE
fA,max: 1.67 mm
V-1082: C31 - B27 f : 8.96 mm CUMPLE
A,lim
fA,max: 1.62 mm
V-1083: B27 - C28 f : 8.96 mm CUMPLE
A,lim
fA,max: 1.05 mm
V-1084: C28 - C25 f : 8.96 mm CUMPLE
A,lim
fA,max: 1.22 mm
V-1085: C25 - C22 f : 9.01 mm CUMPLE
A,lim
fA,max: 1.19 mm
V-1086: C22 - C15 f : 9.06 mm CUMPLE
A,lim
fA,max: 2.73 mm
V-1087: C15 - C11 f : 9.01 mm CUMPLE
A,lim
fA,max: 1.01 mm
V-1088: C11 - C7 fA,lim: 8.96 mm CUMPLE
Página
4242
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 1.98 mm
V-1089: C7 - C3 fA,lim: 8.96 mm CUMPLE
fA,max: 1.70 mm
V-1090: C30 - B26 f : 8.96 mm CUMPLE
A,lim
fA,max: 1.65 mm
V-1091: B26 - C27 f : 8.96 mm CUMPLE
A,lim
fA,max: 1.06 mm
V-1092: C27 - C24 f : 8.96 mm CUMPLE
A,lim
fA,max: 1.12 mm
V-1093: C24 - C21 f : 8.96 mm CUMPLE
A,lim
fA,max: 1.60 mm
V-1094: C21 - C14 f : 8.96 mm CUMPLE
A,lim
fA,max: 0.26 mm
V-1095: C14 - C10 f : 8.96 mm CUMPLE
A,lim
fA,max: 1.45 mm
V-1096: C10 - C6 fA,lim: 8.96 mm CUMPLE
fA,max: 1.90 mm
V-1097: C6 - C2 fA,lim: 8.96 mm CUMPLE
fA,max: 0.09 mm
V-1098: B29 - C20 f : 4.17 mm CUMPLE
A,lim
fA,max: 0.90 mm
V-1099: C20 - C30 f : 11.61 mm CUMPLE
A,lim
fA,max: 0.06 mm
V-1100: C30 - C31 f : 3.23 mm CUMPLE
A,lim
fA,max: 0.82 mm
V-1101: C31 - C32 f : 11.51 mm CUMPLE
A,lim
fA,max: 0.07 mm
V-1102: C32 - B43 f : 3.96 mm CUMPLE
A,lim
3.2.- Cubierta
COMPROBACIONES DE RESISTENCIA (NSR-10, TÍTULO C)
Vigas Estado
Disp. Arm. Q Q S. N,M N,M S. Tc Tst Tsl TNMx TVx TVy TVX st TV Yst T,Disp.sl T,Disp.st T,Geom.sl T,Arm.st Disp. S. Cap. S
'0.000 m' '1.388 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' NO CUMPLE
V-201: C1 - C2 Cumple Cumple N.P. (1) N.P. (1) N.P. (1) N.P. (2) N.P. (1) N.P. (1) N.P. (1) N.P. (1) N.P. (1) N.P. (1) N.P. (1) N.P. (1)
h= 4.0 h= 44.0 h= 24.5 h= 178.2 Cumple Cumple h = 178.2
'0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' CUMPLE
V-202: C2 - C3 Cumple Cumple N.P. (1) N.P. (1) N.P. (1) N.P. (2) N.P. (1) N.P. (1) N.P. (1) N.P. (1) N.P. (1) N.P. (1) N.P. (1) N.P. (1) Cumple
h= 1.3 h= 6.2 h= 13.3 h= 21.0 Cumple h = 21.0
'4.163 m' '4.163 m' '5.182 m' '5.182 m' '0.000 m' '5.182 m' NO CUMPLE
V-203: C3 - C4 Cumple Cumple N.P. (1)
N.P. (1)
N.P. (1)
N.P. (2)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
N.P. (1)
Página
4343
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Página
4444
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple Cumple
x: 0 m
V-202: C2 - C3 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.55 m x: 2.081 m
V-203: C3 - C4 N.P.
(1)
N.P.(1) CUMPLE
Cumple Cumple
x: 0 m x: 2.788 m
V-204: C5 - C6 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.6 m
V-205: C6 - C7 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.6 m x: 2.8 m
V-206: C7 - C8 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.775 m
V-207: C9 - C10 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.575 m
V-208: C10 - C11 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 2.788 m
V-209: C11 - C12 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 5.6 m x: 2.45 m
V-210: C13 - C14 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-211: C14 - C15 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 2.8 m
V-212: C15 - C16 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 5.575 m x: 2.439 m
V-213: C17 - C21 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.575 m
V-214: C21 - C22 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 2.8 m
V-215: C22 - C23 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 5.6 m x: 2.8 m
V-216: C18 - C24 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.575 m
V-217: C24 - C25 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 3.136 m
V-218: C25 - C26 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.8 m
V-219: C19 - C27 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.6 m
V-220: C27 - C28 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 5.575 m x: 2.788 m
V-221: C28 - C29 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.486 m
V-222: C20 - C19 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.35 m x: 1.864 m
V-223: C19 - C18 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.175 m
V-224: C18 - C17 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
Página
4545
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple Cumple
x: 4.3 m x: 1.843 m
V-226: C13 - C9 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.443 m
V-227: C9 - C5 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.275 m x: 1.832 m N.P.(1)
V-228: C5 - C1 N.P. CUMPLE
(1)
Cumple Cumple
x: 4.35 m x: 2.175 m
V-229: C30 - C27 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.35 m x: 2.175 m
V-230: C27 - C24 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.163 m
V-231: C24 - C21 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.325 m x: 2.163 m
V-232: C21 - C14 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.35 m x: 2.175 m
V-233: C14 - C10 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.486 m
V-234: C10 - C6 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.175 m
V-235: C6 - C2 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.748 m
V-236: C32 - C29 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.325 m x: 1.854 m
V-237: C29 - C26 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.175 m
V-238: C26 - C23 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.35 m x: 2.175 m
V-239: C23 - C16 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.175 m
V-240: C16 - C12 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.486 m
V-241: C12 - C8 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.3 m x: 1.843 m
V-242: C8 - C4 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.35 m x: 2.175 m
V-243: C31 - C28 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.163 m
V-244: C28 - C25 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.325 m x: 2.163 m
V-245: C25 - C22 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.175 m
V-246: C22 - C15 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.163 m
V-247: C15 - C11 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 4.325 m x: 2.163 m N.P.(1)
V-248: C11 - C7 N.P. CUMPLE
(1)
Cumple Cumple
Página
4646
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple Cumple
x: 5.6 m x: 3.15 m
V-250: C20 - C30 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-251: C30 - C31 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 2.428 m
V-252: C31 - C32 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
Notación:
sC,sup.: Comprobación de la separación máxima entre barras: Cara superior
sC,Lat.Der.: Comprobación de la separación máxima entre barras: Cara lateral derecha
sC,inf.: Comprobación de la separación máxima entre barras: Cara inferior
sC,Lat.Izq.: Comprobación de la separación máxima entre barras: Cara lateral izquierda
x: Distancia al origen de la barra
h: Coeficiente de aprovechamiento (%)
N.P.: No procede
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 0.24 mm
V-201: C1 - C2 fA,lim: 11.56 mm CUMPLE
fA,max: 0.02 mm
V-202: C2 - C3 fA,lim: 3.33 mm CUMPLE
fA,max: 0.06 mm
V-203: C3 - C4 fA,lim: 3.59 mm CUMPLE
fA,max: 0.27 mm
V-204: C5 - C6 fA,lim: 11.61 mm CUMPLE
fA,max: 0.10 mm
V-205: C6 - C7 fA,lim: 6.67 mm CUMPLE
fA,max: 0.28 mm
V-206: C7 - C8 fA,lim: 11.67 mm CUMPLE
fA,max: 0.27 mm
V-207: C9 - C10 fA,lim: 11.56 mm CUMPLE
fA,max: 0.08 mm
V-208: C10 - C11 f : 6.56 mm CUMPLE
A,lim
fA,max: 0.28 mm
V-209: C11 - C12 f : 11.61 mm CUMPLE
A,lim
fA,max: 0.27 mm
V-210: C13 - C14 f : 11.67 mm CUMPLE
A,lim
fA,max: 0.02 mm
V-211: C14 - C15 f : 3.33 mm CUMPLE
A,lim
fA,max: 0.30 mm
V-212: C15 - C16 f : 11.67 mm CUMPLE
A,lim
fA,max: 0.23 mm
V-213: C17 - C21 f : 11.61 mm CUMPLE
A,lim
Página
4747
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 0.06 mm
V-214: C21 - C22 f : 6.56 mm CUMPLE
A,lim
fA,max: 0.30 mm
V-215: C22 - C23 f : 11.67 mm CUMPLE
A,lim
fA,max: 0.26 mm
V-216: C18 - C24 f : 11.67 mm CUMPLE
A,lim
fA,max: 0.07 mm
V-217: C24 - C25 f : 6.56 mm CUMPLE
A,lim
fA,max: 0.29 mm
V-218: C25 - C26 f : 11.61 mm CUMPLE
A,lim
fA,max: 0.24 mm
V-219: C19 - C27 f : 11.67 mm CUMPLE
A,lim
fA,max: 0.01 mm
V-220: C27 - C28 f : 3.33 mm CUMPLE
A,lim
fA,max: 0.21 mm
V-221: C28 - C29 f : 11.61 mm CUMPLE
A,lim
fA,max: 0.07 mm
V-222: C20 - C19 f : 5.76 mm CUMPLE
A,lim
fA,max: 0.11 mm
V-223: C19 - C18 f : 9.06 mm CUMPLE
A,lim
fA,max: 0.08 mm
V-224: C18 - C17 f : 9.06 mm CUMPLE
A,lim
fA,max: 0.03 mm
V-225: C17 - C13 f : 2.48 mm CUMPLE
A,lim
fA,max: 0.14 mm
V-226: C13 - C9 fA,lim: 8.96 mm CUMPLE
fA,max: 0.02 mm
V-227: C9 - C5 fA,lim: 1.81 mm CUMPLE
fA,max: 0.05 mm
V-228: C5 - C1 fA,lim: 4.38 mm CUMPLE
fA,max: 0.12 mm
V-229: C30 - C27 f : 9.06 mm CUMPLE
A,lim
fA,max: 0.08 mm
V-230: C27 - C24 f : 9.06 mm CUMPLE
A,lim
fA,max: 0.07 mm
V-231: C24 - C21 f : 9.01 mm CUMPLE
A,lim
fA,max: 0.04 mm
V-232: C21 - C14 f : 8.03 mm CUMPLE
A,lim
fA,max: 0.12 mm
V-233: C14 - C10 f : 9.06 mm CUMPLE
A,lim
fA,max: 0.01 mm
V-234: C10 - C6 fA,lim: 1.83 mm CUMPLE
fA,max: 0.13 mm
V-235: C6 - C2 fA,lim: 9.06 mm CUMPLE
Página
4848
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 0.12 mm
V-236: C32 - C29 f : 8.91 mm CUMPLE
A,lim
fA,max: 0.12 mm
V-237: C29 - C26 f : 9.01 mm CUMPLE
A,lim
fA,max: 0.06 mm
V-238: C26 - C23 f : 8.40 mm CUMPLE
A,lim
fA,max: 0.07 mm
V-239: C23 - C16 f : 9.06 mm CUMPLE
A,lim
fA,max: 0.06 mm
V-240: C16 - C12 f : 9.06 mm CUMPLE
A,lim
fA,max: 0.10 mm
V-241: C12 - C8 fA,lim: 9.06 mm CUMPLE
fA,max: 0.05 mm
V-242: C8 - C4 fA,lim: 4.40 mm CUMPLE
fA,max: 0.12 mm
V-243: C31 - C28 f : 9.06 mm CUMPLE
A,lim
fA,max: 0.08 mm
V-244: C28 - C25 f : 9.01 mm CUMPLE
A,lim
fA,max: 0.06 mm
V-245: C25 - C22 f : 9.01 mm CUMPLE
A,lim
fA,max: 0.09 mm
V-246: C22 - C15 f : 9.06 mm CUMPLE
A,lim
fA,max: 0.05 mm
V-247: C15 - C11 f : 9.01 mm CUMPLE
A,lim
fA,max: 0.09 mm
V-248: C11 - C7 fA,lim: 9.01 mm CUMPLE
fA,max: 0.12 mm
V-249: C7 - C3 fA,lim: 9.06 mm CUMPLE
fA,max: 0.18 mm
V-250: C20 - C30 f : 10.84 mm CUMPLE
A,lim
fA,max: 0.02 mm
V-251: C30 - C31 f : 3.33 mm CUMPLE
A,lim
fA,max: 0.12 mm
V-252: C31 - C32 f : 8.92 mm CUMPLE
A,lim
Página
4949
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Página
5050
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Página
5151
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple
x: 0.95 m
V-3002: B63 - C1 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 1.941 m
V-3003: C32 - B135 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 2.034 m x: 0 m
V-3004: B135 - C29 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 6.038 m x: 2.564 m N.P.(1)
V-3005: C5 - C6 N.P. CUMPLE
(1)
Cumple Cumple
x: 6.01 m x: 3.377 m
V-3006: C9 - C10 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 0.774 m
V-3007: C10 - B139 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 5.916 m x: 2.263 m
V-3009: C11 - C12 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 6.065 m x: 2.802 m
V-3010: C13 - C14 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
Página
5252
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple Cumple
x: 0 m x: 0 m x: 0 m x: 0 m
V-3012: B141 - C15 ERROR
Error(1) Error(1) Error(1) Error(1)
x: 5.942 m x: 2.709 m
V-3013: C15 - C16 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.802 m
V-3014: C17 - C21 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0.165 m x: 0.747 m
V-3015: C21 - B143 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 0 m x: 0 m x: 0 m
V-3016: B143 - C22 ERROR
Error(1) Error(1) Error(1) Error(1)
x: 5.942 m x: 2.709 m
V-3017: C22 - C23 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 6.065 m x: 2.802 m
V-3018: C18 - C24 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 0.774 m
V-3019: C24 - B144 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 5.916 m x: 2.263 m
V-3021: C25 - C26 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.802 m
V-3022: C19 - C27 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 0.774 m
V-3023: C27 - B146 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 0 m x: 0 m x: 0 m
V-3024: B146 - C28 ERROR
Error(1) Error(1) Error(1) Error(1)
x: 5.916 m x: 2.919 m
V-3025: C28 - C29 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.991 m
V-3026: C20 - B62 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 2.059 m x: 0 m
V-3027: B62 - C19 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.053 m
V-3028: C19 - B61 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.997 m x: 0 m
V-3029: B61 - C18 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.005 m
V-3030: C18 - B129 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 2.045 m x: 0 m
V-3031: B129 - C17 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0.368 m x: 1.984 m
V-3032: C17 - B59 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 2.066 m x: 0 m
V-3033: B59 - C13 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.089 m
V-3034: C13 - B58 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.911 m x: 0 m
V-3035: B58 - C9 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
Página
5353
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple Cumple
x: 1.999 m x: 0 m
V-3037: B57 - C5 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 1.529 m
V-3038: C5 - B29 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 2.078 m x: 0 m
V-3039: B29 - C1 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 0.774 m
V-3040: C6 - B120 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 0 m x: 0 m x: 0 m
V-3041: B120 - C7 ERROR
Error(1) Error(1) Error(1) Error(1)
x: 0 m x: 2.709 m
V-3042: C7 - C8 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1 m
V-3043: B66 - B29 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0.975 m
V-3045: B67 - C5 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0.95 m
V-3046: B68 - C9 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1 m
V-3047: B69 - C13 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1 m
V-3048: B70 - C17 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1 m
V-3049: B71 - C18 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1 m
V-3050: B72 - C19 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 0.79 m
V-3051: C32 - B79 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1 m
V-3052: B73 - B58 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 0.994 m
V-3055: B107 - B95 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1 m
V-3056: B74 - B59 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 2.389 m
V-3058: B142 - B96 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1 m
V-3059: B75 - B61 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 2.599 m
V-3061: B145 - B98 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1 m
V-3062: B76 - B62 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1 m
V-3064: B64 - C20 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1 m
V-3065: B77 - B57 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
Página
5454
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple Cumple
x: 1 m
V-3068: B134 - B129 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 2.389 m
V-3070: B137 - B97 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-3071: C29 - B80 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m
V-3072: C26 - B83 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m
V-3073: C23 - B85 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m
V-3074: C16 - B87 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m
V-3075: C12 - B89 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m
V-3076: C8 - B91 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0.983 m
V-3077: B64 - B76 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1.619 m
V-3078: B76 - B72 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0.732 m
V-3079: B72 - B75 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1.997 m x: 0.424 m
V-3080: B75 - B71 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 1.291 m
V-3081: B71 - B134 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 2.045 m x: 1.023 m
V-3082: B134 - B70 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 1.278 m
V-3083: B70 - B74 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 2.066 m x: 0.737 m
V-3084: B74 - B69 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 1.044 m
V-3085: B69 - B73 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.961 m
V-3086: B73 - B68 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 1.595 m
V-3087: B68 - B77 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0.721 m
V-3088: B77 - B67 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 1.922 m x: 0.406 m
V-3089: B67 - B66 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 1.352 m
V-3090: B66 - B63 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.966 m
V-3091: B79 - B81 N.P. N.P. N.P. CUMPLE
(2) (2) (2)
Cumple
Página
5555
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple
x: 0 m x: 2.053 m
V-3093: B80 - B82 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.997 m x: 0 m
V-3094: B82 - B83 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.005 m
V-3095: B83 - B84 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 2.045 m x: 0 m
V-3096: B84 - B85 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 1.984 m
V-3097: B85 - B86 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 2.066 m x: 0 m
V-3098: B86 - B87 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.089 m
V-3099: B87 - B88 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.961 m x: 0 m
V-3100: B88 - B89 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.026 m
V-3101: B89 - B90 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 2.024 m x: 0 m
V-3102: B90 - B91 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 1.922 m
V-3103: B91 - B92 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-3104: B92 - B78 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 2.059 m x: 0 m
V-3105: B136 - B146 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.053 m
V-3106: B146 - B145 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.997 m x: 0 m
V-3107: B145 - B144 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.005 m
V-3108: B144 - B137 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 2.045 m x: 0 m
V-3109: B137 - B143 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 1.984 m
V-3110: B143 - B142 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 2.066 m x: 0 m
V-3111: B142 - B141 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.089 m
V-3112: B141 - B140 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 1.961 m x: 0 m
V-3113: B140 - B139 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m x: 2.026 m
V-3114: B139 - B138 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 2.024 m x: 0 m
V-3115: B138 - B120 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
Página
5656
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Cumple Cumple
x: 0 m x: 6.067 m
V-3117: C1 - B113 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 7.295 m x: 2.964 m
V-3118: B113 - C4 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-3119: B97 - B84 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 6.96 m
V-3120: B113 - B93 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 0 m
V-3121: B135 - B81 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m
V-3122: B98 - B82 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m
V-3123: B96 - B86 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m
V-3124: B95 - B88 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m
V-3125: B94 - B90 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m
V-3126: B93 - B92 N.P. N.P. N.P. CUMPLE
(1) (1) (1)
Cumple
x: 0 m x: 6.286 m
V-3127: C20 - B136 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 6.922 m x: 0.636 m
V-3128: B136 - C32 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
x: 6.961 m x: 3.649 m
V-3129: B136 - B135 N.P. N.P. CUMPLE
(1) (1)
Cumple Cumple
Cumple
Notación:
sC,sup.: Comprobación de la separación máxima entre barras: Cara superior
sC,Lat.Der.: Comprobación de la separación máxima entre barras: Cara lateral derecha
sC,inf.: Comprobación de la separación máxima entre barras: Cara inferior
sC,Lat.Izq.: Comprobación de la separación máxima entre barras: Cara lateral izquierda
x: Distancia al origen de la barra
h: Coeficiente de aprovechamiento (%)
N.P.: No procede
Comprobaciones que no proceden (N.P.):
La comprobación no procede, ya que no hay ninguna armadura traccionada.
(1)
No hay esfuerzos que produzcan tensiones normales para ninguna combinación. Por lo tanto, la comprobación no procede.
(2)
Errores:
Se supera el estado límite de fisuración controlada, debido a que los esfuerzos actuantes producen la plastificación de la sección.
(1)
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 0.15 mm
V-3001: C4 - B78 fA,lim: 3.96 mm CUMPLE
fA,max: 0.04 mm
V-3002: B63 - C1 fA,lim: 3.96 mm CUMPLE
fA,max: 1.00 mm
V-3003: C32 - B135 fA,lim: 8.91 mm CUMPLE
fA,max: 1.01 mm
V-3004: B135 - C29 fA,lim: 8.91 mm CUMPLE
fA,max: 0.65 mm
V-3005: C5 - C6 fA,lim: 11.97 mm CUMPLE
fA,max: 0.66 mm
V-3006: C9 - C10 fA,lim: 12.52 mm CUMPLE
fA,max: 0.06 mm
V-3007: C10 - B139 fA,lim: 3.48 mm CUMPLE
fA,max: 0.06 mm
V-3008: B139 - C11 fA,lim: 3.48 mm CUMPLE
fA,max: 0.43 mm
V-3009: C11 - C12 fA,lim: 8.28 mm CUMPLE
fA,max: 0.65 mm
V-3010: C13 - C14 fA,lim: 12.63 mm CUMPLE
fA,max: 0.09 mm
V-3011: C14 - B141 fA,lim: 3.53 mm CUMPLE
fA,max: 0.09 mm
V-3012: B141 - C15 fA,lim: 3.53 mm CUMPLE
Página
5858
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 0.38 mm
V-3013: C15 - C16 fA,lim: 7.50 mm CUMPLE
fA,max: 0.60 mm
V-3014: C17 - C21 fA,lim: 12.22 mm CUMPLE
fA,max: 0.09 mm
V-3015: C21 - B143 fA,lim: 3.47 mm CUMPLE
fA,max: 0.09 mm
V-3016: B143 - C22 fA,lim: 3.47 mm CUMPLE
fA,max: 0.40 mm
V-3017: C22 - C23 fA,lim: 8.25 mm CUMPLE
fA,max: 0.66 mm
V-3018: C18 - C24 fA,lim: 12.63 mm CUMPLE
fA,max: 0.06 mm
V-3019: C24 - B144 fA,lim: 3.48 mm CUMPLE
fA,max: 0.06 mm
V-3020: B144 - C25 fA,lim: 3.48 mm CUMPLE
fA,max: 0.43 mm
V-3021: C25 - C26 fA,lim: 8.83 mm CUMPLE
fA,max: 0.69 mm
V-3022: C19 - C27 fA,lim: 12.63 mm CUMPLE
fA,max: 0.12 mm
V-3023: C27 - B146 fA,lim: 3.53 mm CUMPLE
fA,max: 0.11 mm
V-3024: B146 - C28 fA,lim: 3.53 mm CUMPLE
fA,max: 0.24 mm
V-3025: C28 - C29 fA,lim: 9.11 mm CUMPLE
fA,max: 1.27 mm
V-3026: C20 - B62 fA,lim: 9.06 mm CUMPLE
fA,max: 1.23 mm
V-3027: B62 - C19 fA,lim: 9.06 mm CUMPLE
fA,max: 0.18 mm
V-3028: C19 - B61 fA,lim: 7.19 mm CUMPLE
fA,max: 0.19 mm
V-3029: B61 - C18 fA,lim: 7.19 mm CUMPLE
fA,max: 0.47 mm
V-3030: C18 - B129 fA,lim: 9.06 mm CUMPLE
fA,max: 0.47 mm
V-3031: B129 - C17 fA,lim: 9.06 mm CUMPLE
fA,max: 0.34 mm
V-3032: C17 - B59 fA,lim: 9.06 mm CUMPLE
fA,max: 0.34 mm
V-3033: B59 - C13 fA,lim: 9.06 mm CUMPLE
fA,max: 0.35 mm
V-3034: C13 - B58 fA,lim: 8.96 mm CUMPLE
Página
5959
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 0.35 mm
V-3035: B58 - C9 fA,lim: 8.96 mm CUMPLE
fA,max: 0.21 mm
V-3036: C9 - B57 fA,lim: 7.59 mm CUMPLE
fA,max: 0.20 mm
V-3037: B57 - C5 fA,lim: 7.59 mm CUMPLE
fA,max: 0.84 mm
V-3038: C5 - B29 fA,lim: 8.91 mm CUMPLE
fA,max: 0.88 mm
V-3039: B29 - C1 fA,lim: 8.91 mm CUMPLE
fA,max: 0.16 mm
V-3040: C6 - B120 fA,lim: 3.53 mm CUMPLE
fA,max: 0.15 mm
V-3041: B120 - C7 fA,lim: 3.53 mm CUMPLE
fA,max: 0.57 mm
V-3042: C7 - C8 fA,lim: 12.38 mm CUMPLE
fA,max: 0.50 mm
V-3043: B66 - B29 fA,lim: 17.63 mm CUMPLE
fA,max: 2.13 mm
V-3044: B29 - B113 fA,lim: 17.63 mm CUMPLE
fA,max: 0.07 mm
V-3045: B67 - C5 fA,lim: 4.06 mm CUMPLE
fA,max: 0.11 mm
V-3046: B68 - C9 fA,lim: 3.96 mm CUMPLE
fA,max: 0.11 mm
V-3047: B69 - C13 fA,lim: 4.17 mm CUMPLE
fA,max: 0.11 mm
V-3048: B70 - C17 fA,lim: 4.17 mm CUMPLE
fA,max: 0.12 mm
V-3049: B71 - C18 fA,lim: 4.17 mm CUMPLE
fA,max: 0.07 mm
V-3050: B72 - C19 fA,lim: 4.17 mm CUMPLE
fA,max: 0.01 mm
V-3051: C32 - B79 fA,lim: 3.96 mm CUMPLE
fA,max: 0.12 mm
V-3052: B73 - B58 fA,lim: 11.14 mm CUMPLE
fA,max: 1.82 mm
V-3053: B58 - B140 fA,lim: 9.96 mm CUMPLE
fA,max: 1.64 mm
V-3054: B140 - B107 f : 9.96 mm CUMPLE
A,lim
fA,max: 3.09 mm
V-3055: B107 - B95 fA,lim: 11.66 mm CUMPLE
fA,max: 0.06 mm
V-3056: B74 - B59 fA,lim: 10.13 mm CUMPLE
Página
6060
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 2.29 mm
V-3057: B59 - B142 fA,lim: 11.49 mm CUMPLE
fA,max: 2.98 mm
V-3058: B142 - B96 fA,lim: 11.16 mm CUMPLE
fA,max: 0.16 mm
V-3059: B75 - B61 fA,lim: 22.67 mm CUMPLE
fA,max: 3.56 mm
V-3060: B61 - B145 fA,lim: 22.67 mm CUMPLE
fA,max: 2.74 mm
V-3061: B145 - B98 fA,lim: 10.09 mm CUMPLE
fA,max: 0.81 mm
V-3062: B76 - B62 fA,lim: 17.63 mm CUMPLE
fA,max: 3.13 mm
V-3063: B62 - B136 fA,lim: 17.63 mm CUMPLE
fA,max: 0.05 mm
V-3064: B64 - C20 fA,lim: 4.17 mm CUMPLE
fA,max: 0.09 mm
V-3065: B77 - B57 fA,lim: 4.09 mm CUMPLE
fA,max: 3.71 mm
V-3066: B57 - B138 fA,lim: 16.04 mm CUMPLE
fA,max: 2.69 mm
V-3067: B138 - B94 fA,lim: 9.94 mm CUMPLE
fA,max: 0.17 mm
V-3068: B134 - B129 f : 10.90 mm CUMPLE
A,lim
fA,max: 1.98 mm
V-3069: B129 - B137 f : 10.38 mm CUMPLE
A,lim
fA,max: 3.07 mm
V-3070: B137 - B97 fA,lim: 11.48 mm CUMPLE
fA,max: 0.22 mm
V-3071: C29 - B80 fA,lim: 4.06 mm CUMPLE
fA,max: 0.71 mm
V-3072: C26 - B83 fA,lim: 4.17 mm CUMPLE
fA,max: 0.63 mm
V-3073: C23 - B85 fA,lim: 4.17 mm CUMPLE
fA,max: 0.58 mm
V-3074: C16 - B87 fA,lim: 4.17 mm CUMPLE
fA,max: 0.66 mm
V-3075: C12 - B89 fA,lim: 4.17 mm CUMPLE
fA,max: 0.74 mm
V-3076: C8 - B91 fA,lim: 4.17 mm CUMPLE
fA,max: 0.78 mm
V-3077: B64 - B76 fA,lim: 67.08 mm CUMPLE
fA,max: 1.53 mm
V-3078: B76 - B72 fA,lim: 67.08 mm CUMPLE
Página
6161
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 1.77 mm
V-3079: B72 - B75 fA,lim: 67.08 mm CUMPLE
fA,max: 1.77 mm
V-3080: B75 - B71 fA,lim: 67.08 mm CUMPLE
fA,max: 1.68 mm
V-3081: B71 - B134 fA,lim: 67.08 mm CUMPLE
fA,max: 1.64 mm
V-3082: B134 - B70 fA,lim: 67.08 mm CUMPLE
fA,max: 1.58 mm
V-3083: B70 - B74 fA,lim: 67.08 mm CUMPLE
fA,max: 1.52 mm
V-3084: B74 - B69 fA,lim: 67.08 mm CUMPLE
fA,max: 1.41 mm
V-3085: B69 - B73 fA,lim: 67.08 mm CUMPLE
fA,max: 1.31 mm
V-3086: B73 - B68 fA,lim: 67.08 mm CUMPLE
fA,max: 1.31 mm
V-3087: B68 - B77 fA,lim: 67.08 mm CUMPLE
fA,max: 1.30 mm
V-3088: B77 - B67 fA,lim: 67.08 mm CUMPLE
fA,max: 1.05 mm
V-3089: B67 - B66 fA,lim: 67.08 mm CUMPLE
fA,max: 0.53 mm
V-3090: B66 - B63 fA,lim: 67.08 mm CUMPLE
fA,max: 0.21 mm
V-3091: B79 - B81 fA,lim: 67.05 mm CUMPLE
fA,max: 1.17 mm
V-3092: B81 - B80 fA,lim: 67.05 mm CUMPLE
fA,max: 2.51 mm
V-3093: B80 - B82 fA,lim: 67.05 mm CUMPLE
fA,max: 2.56 mm
V-3094: B82 - B83 fA,lim: 67.05 mm CUMPLE
fA,max: 2.54 mm
V-3095: B83 - B84 fA,lim: 67.05 mm CUMPLE
fA,max: 2.53 mm
V-3096: B84 - B85 fA,lim: 67.05 mm CUMPLE
fA,max: 2.34 mm
V-3097: B85 - B86 fA,lim: 67.05 mm CUMPLE
fA,max: 2.33 mm
V-3098: B86 - B87 fA,lim: 67.05 mm CUMPLE
fA,max: 2.24 mm
V-3099: B87 - B88 fA,lim: 67.05 mm CUMPLE
fA,max: 2.24 mm
V-3100: B88 - B89 fA,lim: 67.05 mm CUMPLE
Página
6262
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 2.34 mm
V-3101: B89 - B90 fA,lim: 67.05 mm CUMPLE
fA,max: 2.35 mm
V-3102: B90 - B91 fA,lim: 67.05 mm CUMPLE
fA,max: 2.08 mm
V-3103: B91 - B92 fA,lim: 67.05 mm CUMPLE
fA,max: 1.92 mm
V-3104: B92 - B78 fA,lim: 67.05 mm CUMPLE
fA,max: 7.56 mm
V-3105: B136 - B146 f : 57.36 mm CUMPLE
A,lim
fA,max: 8.83 mm
V-3106: B146 - B145 f : 57.36 mm CUMPLE
A,lim
fA,max: 8.33 mm
V-3107: B145 - B144 f : 57.36 mm CUMPLE
A,lim
fA,max: 7.91 mm
V-3108: B144 - B137 f : 57.36 mm CUMPLE
A,lim
fA,max: 7.80 mm
V-3109: B137 - B143 f : 57.36 mm CUMPLE
A,lim
fA,max: 7.84 mm
V-3110: B143 - B142 f : 57.36 mm CUMPLE
A,lim
fA,max: 7.80 mm
V-3111: B142 - B141 f : 57.36 mm CUMPLE
A,lim
fA,max: 7.75 mm
V-3112: B141 - B140 f : 57.36 mm CUMPLE
A,lim
fA,max: 7.79 mm
V-3113: B140 - B139 f : 57.36 mm CUMPLE
A,lim
fA,max: 8.23 mm
V-3114: B139 - B138 f : 57.36 mm CUMPLE
A,lim
fA,max: 8.68 mm
V-3115: B138 - B120 f : 57.36 mm CUMPLE
A,lim
fA,max: 7.24 mm
V-3116: B120 - B113 f : 57.36 mm CUMPLE
A,lim
fA,max: 2.45 mm
V-3117: C1 - B113 fA,lim: 15.10 mm CUMPLE
fA,max: 7.31 mm
V-3118: B113 - C4 fA,lim: 30.39 mm CUMPLE
fA,max: 0.04 mm
V-3119: B97 - B84 fA,lim: 1.93 mm CUMPLE
fA,max: 3.40 mm
V-3120: B113 - B93 fA,lim: 14.50 mm CUMPLE
fA,max: 0.12 mm
V-3121: B135 - B81 fA,lim: 3.85 mm CUMPLE
fA,max: 0.04 mm
V-3122: B98 - B82 fA,lim: 1.93 mm CUMPLE
Página
6363
Comprobaciones E.L.U.
Estructura en concreto Fecha: 11/10/18
Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max £fA,lim
fA,lim= L/480
fA,max: 0.04 mm
V-3123: B96 - B86 fA,lim: 1.93 mm CUMPLE
fA,max: 0.04 mm
V-3124: B95 - B88 fA,lim: 1.93 mm CUMPLE
fA,max: 0.04 mm
V-3125: B94 - B90 fA,lim: 1.93 mm CUMPLE
fA,max: 0.04 mm
V-3126: B93 - B92 fA,lim: 1.93 mm CUMPLE
fA,max: 3.29 mm
V-3127: C20 - B136 fA,lim: 15.74 mm CUMPLE
fA,max: 15.70 mm
V-3128: B136 - C32 fA,lim: 28.84 mm CUMPLE
fA,max: 1.66 mm
V-3129: B136 - B135 f : 14.50 mm CUMPLE
A,lim
Página
6464