You are on page 1of 2

Wire Lead Current Transformers

Model 17, 18, 19 Series CR Magnetics offers a versatile line of rugged wire
lead current transformers. Installed around a
current-carrying wire, the sensor provides a current
output relative to the AC input current (within
specification limits). With the output connected across
a resistive load (burden), the voltage
developed is proportional to the input current.

Applications
Remote monitoring of electrical loads

Current Transformers
Input to electrical control system
Detect open heater elements
Indicate phase loss

Model 17 & 18 Monitor motor operation

Shown with optional mounting bracket MB-18 Features


Low cost
Non-contact, isolated current measurement
Surface mounting bracket available for Models 17 and 18
Two case sizes, three different standard ratios

Specifications
Frequency: 50-60 Hz
Case Material: Black thermoplastic
Maximum Continuous Primary Current 4 X Ir
Insulation Voltage 3500 Vac/1min

Regulatory Agencies
Model 19
F
ORDER INFORMATION
BASIC SPECIFICATIONS
Part Number Description
Part Number Imax Vmax Te (typ.) DCR Ω Frequency
Current Transformer with wire leads,
Model 17-2000 .55 dia. opening, 2000 turns
Model 17-2000 200 10 2010 120 50 - 2KHz
Current Transformer with wire leads,
Model 17-1000 .55 dia. opening, 1000 turns
Model 17-1000 200 7.5 1010 31 50 - 2KHz
Current Transformer with wire leads,
Model 18-600 .55 dia. opening, 600 turns
Surface Mounting Bracket
Model 18-600 100 5 605 23 50 - 2KHz
MB-18 for Model 17 or Model 18
Current Transformer with .29 dia. Model 19 25 2 235 3 50 - 2KHz
Model 19 opening, 230 turns
Ir = Maximum AC Input Current to be linearly sensed Vmax = Maximum VAC (Saturation) CT will develop
Te = Effective turns ratio including losses (+/- 10%) (All Specifications tested at 60 Hz)

The Professional
Energy Monitoring
Company 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119
M N TI
ISO 9001:2008 Quality Management System
Web: http://www.crmagnetics.com 91 E-mail: sales@crmagnetics.com
Wire Lead Current Transformers

Outline Drawings

4.5

4 10 OHM
#22 AWG UL
UL STYLE 1213
3.5 20 OHM

3 47 OHM
Secondary Voltage

2.5 1 ohm
. .95 (24.1)
2

1.5
.29 (7.4)DIA.
1

12 (304.8)
0.5
1.04 (26.4)
0
NTS
Current Transformers

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
Primary Current

.46 (11.7)
Model 19 - 230 Turns

7 Model 19:
6
Current Sensing Transformer
SECONDARY VOLTAGE (CAV)

10 ohm perfect
4 47 ohm perfect
100 ohm perfect
200 ohm perfect
3 20 ohm perfect

1
[14]
.55
#20 AWG
0
0 5 10 15 20 25 30 35 40 H1 1.49 UL STYLE 1015
Primary Current (AAC) [37.8]
0.79

Model 18 - 600 Turns X1 X2


[28.1]

[6.2]
0.19
0.25
[4.8]
10 0.95
[13.2]
[24.1] #4-40 INSET
9
24.0 [609.6] 0.52
1.33 [33.8] 0.17 DEEP
8

7
10 OHM
V SECONDARY

6 20 OHM
47 OHM
5 MODEL 17-1000T

Model 17 & 18:


100 OHM
200 OHM
4 510 OHM
1000 OHM

F Current Sensing Transformers


3

1
Also available with PCB pins
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
I PRIMARY

Model 17 - 1000 Turns #6 (M3.5) SCREW


NOT FURNISHED

.105 max.
20 (2.7)
19
18
17
16
15
14
13
12
.25 (6.4) .875 (22.2) .25 (6.4) .750 (19.1)
11
1.37 (34.8) 1.25 (31.08)
10
9 #4-40 FLAT HEAD
8
SCREW FURNISHED
7
6
5
4
3
2
1
0
0 5 10 15 20 25 30 35 40 45 50 55 60
MB-18: Surface Mounting Bracket
Model 17 - 2000 Turns for Model 17 & Model 18

The Professional
Energy Monitoring
Company
3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119
M N TI
ISO 9001:2008 Quality Management System
Web: http://www.crmagnetics.com 92 E-mail: sales@crmagnetics.com