You are on page 1of 1

CP5 on Low Voltage Electrical

Installations
INTRODUCTION
The Singapore Standard CP5:1998 Code of Practice for Electrical Installations applies to the
design, selection, erection, testing and inspection of electrical installations. It covers all general
commercial and industrial electrical installations operating at voltage up to 1000 Volts.

OBJECTIVE
The 2-day course aims to provide participants with an understanding of the design and installation
guidelines for electrical installations complying with CP5: Code of Practice for Electrical Installations.

CONTENTS

Overview
• Fundamentals of Safety Requirements • Equation for calculation of short-circuit
• Codes, Terminations and Definitions current
• Amendment No 1 to CP5 – New cable colour • Characteristics and Applications – Fuses,
code and photovoltaics power supply system MCB and MCCB DETAILS
• Calculations - short circuit current, earth 10th Run: 26 & 27 Nov 2018
Assessment of General Characteristics fault current and circuit breaker sizing Duration: 2 days
• Maximum Demand and Diversity Time: 9.00am to 5.30pm
• Arrangement of live conductors Selection and Erection of Equipment Venue: BCA Academy
• Protection Devices and Safety Services • Method of installation and selection of Fee (incl of GST): S$700.00
• Installation circuit arrangement cables Lunch and refreshments will be provided.
• External Influences • Sizing of conductor sizes Effective 1st Nov 2018, the course fee will be
• Compatibility and Maintainability • Derating factor revised to S$770.00 (incl. GST).
• Types of grouped circuits To enjoy the current course fee, completed
Protection for Safety registration through Online StoreFront (OSF)
• Thermal constraint must be made by 21st Oct 2018.
• Provisions for basic protection • Overload Payment must be received by BCA Academy no
• Protection against Electric Shock – direct and • Voltage Drop Calculation later than 5.00pm on 26th Oct 2018.
indirect contact, SELV, protective measures Course registration will resume at 12.00pm on
• Cable capacities of conduit and trunking 1st Nov 2018.
• Earthed Equipotential Bonding

• Calculations - earth fault loop impedance and Isolation and Switching
AWARD
protective conductor cross-sectional areas • Isolation and Switching Off devices Certificate of Attendance (COA) will be
• Types of Earthing awarded to participants who meet the
• Earthing arrangement in Singapore Location particular requirements attendance requirement.
• Bath tub / shower basin
Protection against Overcurrent and Fault • Swimming Pools CPD POINTS
Current
• Hot Sauna PEB: Pending
• Nature of protective devices
• Protection against overload current Inspection and Testing TARGET AUDIENCE
• Protection against fault current M&E Engineers, Designers,
• Determination of fault current Case Studies & worked examples Contractors and fresh graduates
who wish to acquire knowledge in
electrical installations within the built
LECTURER environment.
ER. HO SOU WENG
B.Sc Electrical & Electronic Engineering
ER. HO SOU WENG received a B.Sc degree in Electrical & Electronic Engineering from the University
of Strathclyde. Er. Ho has acquired considerable experience in Electrical System for Buildings and
Offshore Platforms. Er. Ho is a registered Professional Engineer (Electrical) in Singapore and a
Licensed Electrical Engineer registered with EMA.

To register, please log into our Online StoreFront (OSF) at


https://eservices.bcaa.edu.sg/registration/#/login or scan QRcode and
search for course code 79064
© 2016 Copyright of Building and Construction Authority. All rights reserved.
79064.110918.0021