Professional Documents
Culture Documents
P1 P2 P3 P4 bw
4.600 m 4.600 m 4.600 m
hf
15.000 m B
DATOS
σt = 1.5 Kg/cm² a 1.50m de profundi da d f´c = 210 Kg/cm² rec.= 0.075 m
Ko = 5000 Tn/m³ fy = 4200 Tn/m³ e pi s o = 0.150 m
DF = 1.5 m Es = 2.10E+06 Kg/cm2 ɣ Co = 2.4 Tn/m3 pes o vol umetri co del concreto a rma do
NPT= 0.1 m ɣ Cs = 2.0 Tn/m3 pes o vol umetri co del concreto s i mpl e
s /c = 200 Kg/m2 ɣs = 1.7 Tn/m3 pes o vol umetri co del s uel o
Col umna 01 0.4 m 0.3 m Col umna 02 0.4 m 0.3 m Col umna 03 0.4 m 0.3 m Col umna 04 0.4 m 0.3 m
DIAGRAMA DE CARGAS
P1= 9.95 + 0.00 P2= 37.08 + 6.00 P3 = 61.67 + 12.00 P4 = 34.55 + 6.00
σn = = 15.00 Tn/m2 pa ra el ca s o de s i s mo
2. DIMENSIONAMIENTO EN PLANTA
A. SIN CONSIDERAR EFECTOS DE SISMO
A.1. POSICION DE LA RESULTANTE CONSIDERANDO ATERNANCIA DE LA CARGA:
ALTERNANCIA
1 5.00 x 40.08 + 10.00 x 67.67 + 15.00 x 40.55 + 1485.350 50 % 50 % 50 % 100 %
Xg = = = 9.386 m
158.250 158.250
11 5.00 x 43.08 + 10.00 x 73.67 + 15.00 x 40.55 + 1560.350 100 % 100 % 100 % 100 %
Xg = = = 9.329 m
167.250 167.250
12 5.00 x 43.08 + 10.00 x 73.67 + 15.00 x 40.55 + 1560.350 50 % 100 % 100 % 100 %
Xg = = = 9.329 m
167.250 167.250
13 5.00 x 43.08 + 10.00 x 73.67 + 15.00 x 40.55 + 1560.350 100 % 100 % 100 % 100 %
Xg = = = 9.329 m
167.250 167.250
EXCENTRICIDAD 15 15
e1 = - 9.20 = -1.70 m e12= - 9.41 = -1.91 m
2 2
e1 < L/6 = 2.567 m O.K e1 < L/6 = 2.567 m O.K
1.00 * 164.250 6.00 * ( 164.250 -* 1.91) = 9.30 Tn/m2 < σn = 15.00 Tn/m2 O.K
σ1 = -
15.40 * 2 2.00 * 15.40 ²
1.00 * 158.250 6.00 * ( 158.250 -* 1.70) = 1.74 Tn/m2 < σn = 15.00 Tn/m2 O.K
σ1 = +
15.40 * 2.00 2.00 * 15.40 ²
1.00 * 158.250 6.00 * ( 158.250 -* 1.70) = 8.53 Tn/m2 < σn = 15.00 Tn/m2 O.K
σ1 = -
15.40 * 2 2.00 * 15.40 ²
CARGAS DE SERVICIO
RESUMEN DE PRESIONES
- CARGAS DE GRAVEDAD - CARGAS DE GRAVEDAD + SISMO LONGITUDINAL HORARIO
σ1 = 1.37 Tn/m2 → W1 = 2.73 Tn/m σ1 = 9.30 Tn/m2 → W1 = 18.60 Tn/m
σ'1 = 1.74 Tn/m2 → W'1 = 3.48 Tn/m σ'1 = 9.30 Tn/m2 → W'1 = 18.60 Tn/m
- CARGAS DE GRAVEDAD + SISMO LONGITUDINAL ANTI-HORARIO - CARGAS DE GRAVEDAD + SISMO TRANSVERSAL HORARIO
σ1 = 9.30 Tn/m2 → W1 = 18.60 Tn/m σ1 = 9.30 Tn/m2 → W1 = 18.60 Tn/m
σ'1 = 8.53 Tn/m2 → W'1 = 17.07 Tn/m σ'1 = 9.30 Tn/m2 → W'1 = 18.61 Tn/m
18.60 Tn/m
18.61 Tn/m
15.40 m
0.6
- a ncho de col umna 0.40 m λL = 1.60 adoptado
entonces bw = 0.45 m Ko = 5000.0 Tn/m3 2
B = 2.00 m f'c = 210.0 Kg/cm²
hf = 0.60 m (a s umi da ) Ec = 2173706.51 Tn/m²
Lm = 5.00 m H= 1.20 m VALOR DE "H" ASUMIDO
columna 2 columna 1
m = 90.754 cm m = 65.377 cm
n= 79.166 cm n= 79.166 cm
bo = 339.840 cm bo = 209.920 cm
Ao = 7184.634 cm2 Ao = 5175.642 cm2
Pu = 62.17 Tn Pu = 14.36 Tn
Vup = 52.52 Tn Vup = 7.41 Tn
ɸVcp1 = 287.88 Tn ɸVcp1 = 177.82 Tn
ɸVcp2 = 233.70 Tn ɸVcp2 = 144.36 Tn
Vup < ɸVcp : O.K Vup < ɸVcp : O.K
DISEÑO DEL REFUERZO PARA VIGAS CONTINUAS DE CIMENTACION
ACERO LONGITUDINAL
VIGAS CONTINUAS DE CIMENTACION EJE FD-FA
1. Colocar dimensiones de la viga continua
45.0 cm
5 Ø 3/4 '' As Positivo 9.26 cm² Verificar As min y As max
60.0 cm
2 Ø 1/2" Para evitar el pandeo del estribo
12.60 cm²
60.0 cm
As Negativo 9.07 cm² Verificar As min y As max
10 Ø 1/2 '' 200.0 cm
12.60 cm²
ACERO TRANSVERSAL
sadm Suelo = 15.000 Tn/m² REFUERZO NEGATIVO
s diseño = 22.500 Tn/m² f`c = 210.00 Kg/cm2
Tomando B = 1.00 m □Ø 3/8 '' @ 0.27 fy = 4200.00 Kg/cm2
Mom. Neg = 6.76 Tn-m b = 100.00 cm
45.0 cm h = 60.00 cm
Ø barra = 1/2 ''
60.0 cm 1/2 '' @ 0.355 Ø estribo = 3/8 ''
recub. = 7.50 cm
77.5 cm d = 50.91 cm
M = 6.76 Tn-m
60.0 cm a = 0.833 cm
As = 3.54 cm²
200.0 cm Ø barra = 1/2 ''
As = 1.267 cm²
22.50 Tn/m @= 35.50
VERIFICACION POR CORTANTE
Vu = 25.000 Tn A cara de columna Ø.Vc = Vud =
Wu = 1.49 Tn/m 66.475 Tn > 24.244 Tn Ok
recub. = 7.50 cm
Ø barra = 1/2 ''
Ø estribo = 3/8 ''
b= 200.00 cm
d= 50.91 cm
DISEÑO DE REFUERZO TRANSVERSAL
REFUERZO DENTRO DE LA ZONA DE CONFINAMIENTO
Se colocará refuerzo Transversal por confinamiento a una distancia "2d" medida desde la cara del apoyo.
2d = 2.218 m
Ø estribo = 3/8 ''
La separacion de los estribos debe ser:
S ≤ d/4 = 27.73 cm S = 27.00 cm □Ø 3/8 '' @ 0.27
S≤ 30.00 cm