You are on page 1of 9

SPECIFICATION AND SCHEDULE OF QUANTITIES

SL DESCRIPTION QTY UNIT RATE AMOUNT


1 EARTH WORK

Earth work in excavation by mechanical


means (Hydraulic excavator) / manual
means in foundation trenches or drains
(not exceeding 1.5 m in width or 10 sqm
on plan), including dressing of sides and
ramming of bottoms, lift upto 1.5 m,
including getting out the excavated soil
and disposal of surplus excavated soil as
directed, within a lead of 50 m. All kinds
of soil. Extra for every additional lift of 1.5
m or part thereof in excavation / banking
excavated or stacked materials. All kinds
of soil.

C.P.W.D spec DSR code Clause 2.8&2.26.1


Total 438.32 CUM 280 122728.2

Earth work in excavation by mechanical


means (Hydraulic excavator) / manual
means in foundation trenches or drains
(exceeding 1.5 m in width or above 10
1.2 sqm on plan), including dressing of sides
and ramming of bottoms, lift above 1.5
m, including getting out the excavated
soil and disposal of surplus excavated soil
as directed, within a lead of 50 m. All
kinds of soil. Extra for every additional lift
of 1.5 m or part thereof in excavation /
banking excavated or stacked materials.
All kinds of soil
Above 1.5m depth including ramp and lift
pit
Main building, lift, sump septic tank

Total 321.43 CUM 380 122144


Providing Anti Termite treatment using
approved chemicals like Alderin E-300 or
1.3 equivalent in plinth area and 1m width of
outside perimeter as specified, including
cost of all materials and labour charges
etc., complete as directed. (Plinth area
only will be measured for payment)

Below PCC Slab 315.56

Total 315.56 SQM 200 63112

Providing and Back Filling with red


earth/murrum in layers not exceeding 15
cm, amply watered and consolidated to
the correct level and thereafter flooding
1.4 the surface with water for atleast 24
hours, allowed to dry and then rammed,
consolidated, after making good any
settlement, including the cost of all
materials, conveyance, lead, lift, labour,
watering, ramming etc complete as
directed. 142.00

Total 142.00 CUM 1250 177504

B CONCRETE

Unless otherwise specified the following


will apply for all items of plain and
NOTE : reinforced cement concrete. Rates
applied is inclusive of the following but
excluding cost of reinforcements and
inserts like bolts, plates, sleeves, pipes
etc.

All form work, drip moulds, centering and


1 shuttering. Shuttering shall be steel or
plywood as directed.

2 Adequate protection to edges and corners


from damage during construction.

Work either straight, curved, plain,


3 tapered, circular, sloping or grid pattern
for beams and slabs.

4 Keeping the work watered for atleast 21


days after casting.
5 Roughing/hacking concrete surface where
required after removing of centering or
shuttering to receive plaster.

6 Building and placing in position any insert


supplied.

7 Machine mixing and consolidation using


vibrators of approved type.

8 Coarse sand shall be used for concrete


work.

9 Coarse aggregate shall be crusher broken


granite, basalt or trap of sizes specified.

The Contractors are particularly advised


10 to study relevant drawings carefully
before quoting.

The Contractors shall submit drawings


11 showing the scheme of formwork
(shuttering) for beams and slabs etc., and
this shall be obligatory.

All concrete used for reinforced concrete


12 work (structural concrete) shall be of
design mix

13 Minimum cement content for 43 grade


controlled concrete shall be as follows :-

b) M - 20 -300Kg

c) M - 25 300Kg

d) M - 30 -320Kg

e) M - 35 -340Kg

f) M - 40 -360Kg

2 PLAIN CEMENT CONCRETE .

Providing and laying in position cement


concrete of specified grade excluding the
cost of centering and huttering - All work
up to plinth level :
1:5:10 (1 cement : 5 coarse sand : 10
graded stone aggregate 40 mm nominal
size)
C.P.W.D spec DSR code Clause 4.1.10
Below Footing 29.22
Below Plinth Beam 10.64
PCC Slab 31.56

Total 71.42 CUM 5800 414233.22


3 REINFORCED CEMENT CONCRETE

Providing and laying cement concrete


conforming to specified grade (IS 456-
2000) with 20mm and down size graded
aggregate of granite as per
specifications, excluding to cost of
reinforcement, but including providing
rigid water tight centering and shuttering
fixed in position, compacting with
vibrators, curing etc.,

including labour for careful removal of


formwork supports, scaffolding, hacking
the exposed surface to receive plaster
wherever necessary etc., complete as per
drawings and specifications for the
following items of work :

Providing and laying in position specified


grade of reinforced cement concrete,
3.1 including the cost of centering,
shuttering, finishing and excluding the
cost of reinforcement - All work up to
plinth level :

1:2:4 (1 cement : 2 coarse sand : 4


graded stone aggregate 20mm nominal
size)

Centering and shuttering including


strutting, propping etc. and removal of
form for : Foundations, footings, bases of
columns, etc.
Footing 101.11 CUM
Column upto Plinth Beam 11.06 CUM
Plinth Beam 20.83 CUM

Total 132.99 CUM 8920.00 1186309.41

Reinforced cement concrete work in rcc


3.2 wall, including the cost of centering,
shuttering, finishing and excluding the
cost of reinforcement, with 1:2:4 (1
cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size).including
Centering and shuttering including
strutting, propping etc. and removalof
form for :Walls (any thickness)
(average 0.15 thick & form work 13.32
m2 for 1 m3)

Lift 5.76

TOTAL 5.76 CUM 9295 53531.76

Providing and laying in position machine


batched and machine mixed design mix
3.3 M-25 grade cement concrete for
reinforced cement concrete work, using
cement content as per approved design
mix, including pumping of concrete to site
of laying but including the cost of
centering, shuttering, finishing and
excluding the cost of reinforcement,

including admixtures in recommended


proportions as per IS: 9103 to accelerate,
retard setting of concrete, improve
workability without impairing strength
and durability as per direction of
Engineer-in-charge. (Note :- Cement
content considered in this item is @ 330
kg/cum. Excess/less cement used as per
design mix is payable/recoverable
separately).
All works above plinth level .

Extra for providing richer mixes at all floor


levels. Note:- Excess/less cement over the
specified cement content used is payable
recoverable separately

Providing M-30 grade concrete instead of


M-25 grade BMC/RMC. (Note:- Cement
content considered in M-30 is @
340kg/cum)

Centering and shuttering including


strutting, propping etc. and removal of
form for :base slab(any thickness)
(average 0.15 thick & form work 6.67 m2
for 1 m3)

C.P.W.D spec DSR code Clause ,5.33.1,


5.34.1,5.9.6
Sump Tank 13.29
Rain Water Harvesting Tank 7.38
Sewage Treatment Plant 41.63

Total 62.29 CUM 10370.00 645984.63


Providing and laying in position machine
batched and machine mixed design mix
M-25grade cement concrete for
3.4 reinforced cement concrete work, using
cement content as per approved design
mix, including pumping of concrete to site
of laying but including the cost of
centering, shuttering, finishing and
excluding the cost of reinforcement,
including admixtures in recommended
proportions as per IS: 9103

to accelerate, retard setting of concrete,


improve workability without impairing
strength and durability as per direction of
Engineer-in-charge. (Note :- Cement
content considered in this item is @ 330
kg/cum. Excess/less cement used as per
design mix is payable/recoverable
separately)All works above plinth level

Extra for providing richer mixes at all floor


levels. Note:- Excess/less cement over the
specified cement content used is payable
recoverable separately

Providing M-30 grade concrete instead of


M-25 grade BMC/RMC. (Note:- Cement
content considered in M-30 is @
340kg/cum)

Centering and shuttering including


strutting, propping etc. and removalof
form for columns (9.99 m2 for 1m3 of
concrete column 30 x60 column
assumed)
Add for using extra cement in the items of
design mix over and above the specified
cement content therein
Add 150ml admixture for each bag of
cement
For COLUMNS
C.P.W.D spec DSR code Clause ,5.33.2,
5.34.1,5.9.6,5.35
Ground Floor 18.41
First Floor 18.41
Second Floor 18.41
Third Floor 18.41
Fourth Floor 18.41
Fifth Floor 18.41
Sixth Floor 8.27
water tank column, beam, slab, wall 18.71

Total 137.43 CUM 10750.00 1477361.8


Reinforced cement concrete work in
3.5 beams, including the cost of centering,
shuttering, finishing and excluding the
cost of reinforcement, with 1:2:4 (1
cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size).including

Centering and shuttering including


strutting, propping etc. and removal of
form for beam : (11.02 m2 for 1 m3 of
concrete average size of beam 23 x 55)
For BEAMS
C.P.W.D spec DSR code Clause 5.3 & 5.9.5

Ground Floor 32.83


First Floor 32.83
Second Floor 32.83
Third Floor 32.80
Fourth Floor 32.80
Fifth Floor 34.46
Sixth Floor 12.50

Total 211.07 CUM 10650.00 2247854.55

Reinforced cement concrete work in


suspended floor slabs, roof slab , balcony
3.6 slabs,canopies, lofts, including the cost
of centering, shuttering, finishing and
excluding the cost of reinforcement, with
1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal
size).(12mm thick slab)

Centering and shuttering including


strutting, propping etc. and removal of
form for slab: (8.33 m2 of 1 m3 of
concrete)
For SLABS
C.P.W.D spec DSR code Clause 5.3 &
5.9.3
Ground Floor Roof 40.00
First Floor Roof 39.82
Second Floor Roof 39.82
Third Floor Roof 39.82
Fourth Floor Roof 39.82
Fifth Floor Roof 39.18
Sixth Floor Roof 16.02
Lift Floor Roof 2.49

Total 256.96 CUM 10550.00 2710953.8475


Reinforced cement concrete work in lintel
beam including the cost of centering,
3.7 shuttering, finishing and excluding the
cost of reinforcement, with 1:2:4 (1
cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size).

Centering and shuttering including


strutting, propping etc. and removal of
form for Lintels, beams (8.69 m2 for 1 m3
of concrete)
For LINTEL BEAM
C.P.W.D spec DSR code Clause 5.3 & 5.9.5

Ground Floor 2.06


First Floor 6.15
Second Floor 6.15
Third Floor 6.15
Fourth Floor 6.15
Fifth Floor 6.15
Sixth Floor 1.63
Terrace Floor 1.25
Lift Room 0.63

Total 36.33 CUM 10640.00 386501.67

Reinforced cement concrete work in


staircases and spiral stair cases including
3.8 the cost of centering, shuttering, finishing
and excluding the cost of reinforcement,
with 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal
size). including

Centering and shuttering including


strutting, propping etc. and removal of
form for stair :( 7.33 m2 for 1 m3 of
concrete.assuming 15 cm thick waist
slab)
Stairs, (excluding landings) except spiral-
staircases
For STAIR
C.P.W.D spec DSR code Clause 5.3 & 5.9.7

Ground Floor 3.56


First Floor 3.56
Second Floor 3.56
Third Floor 3.56
Fourth Floor 3.56
Fifth Floor 3.56
Sixth Floor 3.56

Total 24.94 CUM 10500.00 261912


REINFORCEMENT FOR RCC

Providing and fixing steel reinforcement.


Rate includes labour charges for cutting,
bending, cranking, fabricating and tying
in position steel bars conforming to IS 434
and IS 1786 for RCC works including cost
of soft drawn annealed binding wire of not
less than 20 gauge, PVC / NYLON
coverblocks of required thickness, all
leads, lifting and handling charges, cost
of tools, tackle, scaffolding, wastages,
rolling margins, chairs , hooked ends etc.,
complete as per specifications, drawings
and directions of the consultant.

Steel reinforcement for R.C.C. work


4
including straightening, cutting, bending,
placing in position and binding all
complete upto plinth level. Using
Thermo-Mechanically Treated bars
C.P.W.D spec DSR code Clause 5.22.6
4.a Footing 16.18
4.b Column Below Plinth Beam 1.66
4.c Plinth Beam 2.50
4.d Sump,Rain Water ,Sewage,Lift 6.81
4.e Ground Floor 10.31
4.f First Floor 11.08
4.g Second Floor 11.08
4.h Third Floor 11.08
4.i Fourth Floor 11.08
4.j Fifth Floor 11.23
4.k Sixth Floor 4.23
4.l Lift Floor Roof 3.37
4.m Water Tank 1.87

Total 102.47 MT 77000.00 7890086.80