g Proj: Admin
Ref :
Tel:d Date: 14/08/17
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
Reinforcement checks are in accordance with BS8110:1997 and the Reinforced Concrete Designers Handbook by Reynolds
and Steedman
The effective depth and the area of the tensile reinforcement for
each bar type is: d (mm) As ( mm2 )
eff
- layer 1 - bar type 1 547 603
The ultimate shear capacity of the section, including the shear reinforcement ( 157 mm 2 at 300 centres ) is
V = (((1/ )*f *A /(b *s ))+v )*b *d /1000
u msv yv sv w v c w eff
= (((1/1.15)*500*157/(300*300))+0.481)*300*547/1000
= 203.4 kN