BROEN UniFlex TM FRONT control valves and OUTLETS

front control

and outlets
UNIFLEX™

valves
BROEN

PREMIUM
LAB
BROEN UniFlex TM FRONT control valves and OUTLETS
Ta b l e of Content s
PREMIUM

Content Page
Table of Content 2

BROEN UNIFLEXTM PREMIUM 4

Product Overview 5

Valves & Outlets


Water.............................................................................................................................................................6-10
BROEN UniFlex TM FRONT control valves and OUTLETS

Special Water..........................................................................................................................................11-13

Coolant Water........................................................................................................................................14-15

Burning Gases........................................................................................................................................16-18

Technical 2.0 Gases / Vacuum / High Flow...............................................................................19-22

Technical 4.0 Gases / Oxygen.........................................................................................................23-25

Pure 5.0 Gases........................................................................................................................................26-27

Pure 6.0 Gases........................................................................................................................................28-29

Corrosive Gases.....................................................................................................................................30-31

Mounting Accessories 32

Mounting Instructions
Valves and Outlets for All Media....................................................................................................................................33
Outlets for Fume Hoods with a Double Wall Construction...............................................................................33

Pipe Installation
Water / Special Water (SS model) / Technical and Burning Gases (4.0 and 5.0 Gases).........................34
Special Water (PP models only) / Corrosive Gases 35

-2- w w w. b r o e n . c o m
BROEN UniFlex TM FRONT control valves and OUTLETS
PREMIUM

-3-
w w w. b r o e n . c o m
B R O E N U N I F L E X TM P R E M I U M
PREMIUM

T H IS IS B R O E N U N I F L E X ™ P R E M I U M

BROEN UniFlexTM PREMIUM line offers a very high quality and durability combined with the complete program, which ads up
to low LCC (Life Cycle Costs). Our PREMIUM line takes the standards in the market to a higher level.

BROEN OFFERS Cu s tomer B enef i t s


BROEN UniFlex TM FRONT control valves and OUTLETS

Safe and Simple Installation


Complete Range – One Stop Shopping
Just-In-Time Deliveries
➟ M O R E E ff i c i en c y

One Valve – More Connections


Approved as a Complete System
Customization to Meet Customer Needs
➟ M O R E P l u g & P l ay

Media Indication According to EN 13792


Uniform Design / Dimensions
Fewer connections points
➟ M O R E S i mp l i c i t y

Double Sealing
100 % Testing
BROEN Polycoat – Powder Coating
➟ MORE Quality

T H IS IS B R O E N U N I F L E X ™
BROEN UniFlexTM is a unique and patented connection, which allows customers to choose from various connection
methods, such as hoses, CU-, PEX of stainless steel pipes, without changing the valve itself. It provides unique flexibility, not
only for the installer, but also for the end-user. Due to the flexibility of the system, the quick installation and savings on fit-
tings, this system offers lower TIC (Total Installed Costs).

-4- w w w. b r o e n . c o m
P ro d u c t O v er v i e w
PREMIUM

outlets
page 8-10

page 12-13

page 15

page 17-18

page 21-22

page 24-25

page 27 Flange

BROEN UniFlex TM FRONT control valves and OUTLETS


(Optional, to be ordered separately,
page 29 See page 30)

page 31

BROEN UniFlexTM flexible hoses

FRONT CONTROL VALVES


page 6-7

page 11

page 14

page 16

page 19 BROEN UniFlexTM connection fittings and adaptors


for Cu, SS, PEX and PA pipes
page 23

page 26

page 28

page 30

For more information about BROEN UniFlexTM hoses, connection fittings and adaptors, please
contact your BROEN LAB representative or refer to www.broen.com

w w w. b r o e n . c o m -5-
F ront Contro l v a l v e s
w at e r PREMIUM

Available with or without


service valve according to
product numbers listed below
BROEN UniFlex TM FRONT control valves and OUTLETS

Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
Handle: Metal, BROEN POLYCOAT powder coated For standard configuration please refer to the item
with media indication according to EN13792. numbers below.
Headwork: Ceramic Other options:
Opening/closing function: 180°
- a valve for different medium
Temperature range: 0-90°C - a valve for front side mounting
Max. working pressure: 10 bar / 147 psi - a valve without mounting kit
Test pressure: 1 x working pressure - national approvals
Inlet/outlet: BROEN UniFlexTM For further information, please contact your BROEN LAB
Weight: 0.7 kg representative.

M ater i a l s w i th me d i a c onta c t
Metals: Brass
Rubber: EPDM
Plastics: POM
Lubricant: Silicone based
Ceramics: Al-oxyd 96%
Model

Service valve

Media Without service valve With service valve

WPC Potable water, cold 25115071001 25115081001

WPH Potable water, hot 25115071002 25115081002

WNC Non-potable water, cold 25115071007 25115081007

WNH Non-potable water, hot 25115071008 25115081008

Delivered with mounting accessories

-6- w w w. b r o e n . c o m
F ront Contro l v a l v e s - m i x er
w at e r PREMIUM

BROEN UniFlex TM FRONT control valves and OUTLETS


Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
Handle: Metal, BROEN POLYCOAT powder coated with For standard configuration please refer to the item
media indication according to EN13792. numbers below.
Cartridge: Ceramic (with flow and temperature regulation Other options:
or two step opening)
- a valve without mounting kit
Temperature range: 0-90°C
Max.working pressure: 10 bar / 147 psi For further information, please contact your BROEN LAB
representative.
Test pressure: 1 x working pressure
Inlet/outlet: BROEN UniFlexTM
Weight: 0.6 kg

M ater i a l s w i th me d i a c onta c t
Metals: Brass
Rubber: EPDM
Plastics: POM
Lubricant: Silicone based
Ceramics: Al-oxyd 96%

Model

With flow and temperature


Media regulation cartridge With two step opening cartridge

WPT Potable water, tempered 25115291035 25115311035

WNT Non-potable water, tempered 25115291037 25115311037

Delivered with mounting accessories

w w w. b r o e n . c o m -7-
out l et s
w at e r PREMIUM
Scope of delivery

Addional mounting information


see page 32-35
BROEN UniFlex TM FRONT control valves and OUTLETS

Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
BROEN UniFlexTM outlets have an integrated media For standard configuration please refer to the item
indication according to EN 13792. numbers below.
Inlet/outlet: BROEN UniFlexTM Other options:
Max. wall thickness: 20mm
- other media
Weight: 0.5 kg (swivel spout: 0.7 kg) - flange
- non-return valve
M ater i a l s w i th me d i a c onta c t - fixed nozzle
Metals: Brass - other standout
Rubber: EPDM - straight rear wall connection
- wall thickness 20-40mm
Lubricant: Silicone based
- double wall mounting
- table mounting
- additional support in case of a thin panel
- national approvals
For further information, please contact your BROEN LAB
representative.
w i th remo v a b l e no z z l e
Model / Standout

107mm [4”] S
60mm [2 1/2” ]

62mm [2 7/16” ]

Media 45° S = 53mm S = 75mm S = 90mm

WPC Potable water, cold 25111011001-40 25111111001-40 25111211001-40 25111311001-40

WPH Potable water, hot 25111011002-40 25111111002-40 25111211002-40 25111311002-40

WNC Non-potable water, cold 25111011007-40 25111111007-40 25111211007-40 25111311007-40

WNH Non-potable water, hot 25111011008-40 25111111008-40 25111211008-40 25111311008-40

WPT Potable water, tempered 25111011035-40 25111111035-40 25111211035-40 25111311035-40

WNT Non-potable water, tempered 25111011037-40 25111111037-40 25111211037-40 25111311037-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

-8- w w w. b r o e n . c o m
out l et s
w at e r PREMIUM

w i th qu i c k re l e a s e c oup l i n g
Model / Standout

104mm [4”] S

57mm [2 1/2” ]

89mm [3 1/2”]
Media 45° S = 53mm S = 75mm S = 90mm

WPC Potable water, cold 25111021001-40 25111121001-40 25111221001-40 25111321001-40

BROEN UniFlex TM FRONT control valves and OUTLETS


WPH Potable water, hot 25111021002-40 25111121002-40 25111221002-40 25111321002-40

WNC Non-potable water, cold 25111021007-40 25111121007-40 25111221007-40 25111321007-40

WNH Non-potable water, hot 25111021008-40 25111121008-40 25111221008-40 25111321008-40

WPT Potable water, tempered 25111021035-40 25111121035-40 25111221035-40 25111321035-40

WNT Non-potable water, tempered 25111021037-40 25111121037-40 25111221037-40 25111321037-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

w i th s w i v e l s pout
Model / Standout
53mm [2”] S

53mm [2”] U
210mm
102mm [4 “]

[8 1/4”]

Media U = 150mm U = 200mm S = 150mm S = 200mm

WPC Potable water, cold 25112121001-40 25112131001-40 25112141001-40 25112151001-40

WPH Potable water, hot 25112121002-40 25112131002-40 25112141002-40 25112151002-40

WNC Non-potable water, cold 25112121007-40 25112131007-40 25112141007-40 25112151007-40

WNH Non-potable water, hot 25112121008-40 25112131008-40 25112141008-40 25112151008-40

WPT Potable water, tempered 25112121035-40 25112131035-40 25112141035-40 25112151035-40

WNT Non-potable water, tempered 25112121037-40 25112131037-40 25112141037-40 25112151037-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

w w w. b r o e n . c o m -9-
out l et s
w at e r PREMIUM
ben c h mounte d out l et w i th s w i v e l s pout

Model / Standout

300mm [11 3/4”]

180mm [7”]
Media U = 120mm U = 150mm

WPC Potable water, cold 25113041001-40 25113001001-40


BROEN UniFlex TM FRONT control valves and OUTLETS

WPH Potable water, hot 25113041002-40 25113001002-40

WNC Non-potable water, cold 25113041007-40 25113001007-40

WNH Non-potable water, hot 25113041008-40 25113001008-40

WPT Potable water, tempered 25113041035-40 25113001035-40

WNT Non-potable water, tempered 25113041037-40 25113001037-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

4 5 ° O ut l et w i th f i x e d or s w i v e l s pout
Model / Standout

120mm[4 1/2”]
300mm [11 3/4”]

180mm[7”]

Media Fixed spout Swivel spout

WPC Potable water, cold 25113071001-40 25113081001-40

WPH Potable water, hot 25113071002-40 25113081002-40

WNC Non-potable water, cold 25113071007-40 25113081007-40

WNH Non-potable water, hot 25113071008-40 25113081008-40

WPT Potable water, tempered 25113071035-40 25113081035-40

WNT Non-potable water, tempered 25113071037-40 25113081037-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

-10- w w w. b r o e n . c o m
F ront Contro l v a l v e s
S p e c i a l W at e r PREMIUM

Available in PP or Stainless
Steel according to product
numbers listed below

BROEN UniFlex TM FRONT control valves and OUTLETS


Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
Handle: Metal, BROEN POLYCOAT powder coated For standard configuration please refer to the item
with media indication according to EN13792. numbers below.
Headwork: Diaphragm type Other options:
Opening/closing function: 1 1/2 x 360°
- a valve without mounting kit
Max. working pressure: 10 bar / 147 psi - a valve for front side mounting
Test pressure: 1 x working pressure
For further information, please contact your BROEN LAB
Weight: 0.7 kg representative.
PP valve SS Valve
Temperature range: Temperature range:
0-65°C 0-90°C
Inlet/outlet: Inlet/outlet:
Push couplings for BROEN UniFlexTM
OD10mm pipes

M ater i a l s w i th me d i a c onta c t
PP valve SS Valve
Rubber: EPDM Rubber: EPDM
Plastics: PP Metals: SS (AISI 316)

Model

Media PP valve SS valve

WDI Distilled water 25115331003 25115351003

WDC Deionised water, cold 25115331036 25115351036

Delivered with mounting accessories

w w w. b r o e n . c o m -11-
out l et s - P P
S p e c i a l W at e r PREMIUM
Scope of delivery

Addional mounting information


see page 32-35

PP outlet
BROEN UniFlex TM FRONT control valves and OUTLETS

Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
BROEN UniFlexTM outlets have an integrated media For standard configuration please refer to the item
indication according to EN 13792. numbers below.
Inlet: Push couplings for OD10mm pipes Other options:
Max. wall thickness: 20mm
- flange
Weight: 0.5 kg - wall thickness 20-40mm
- swivel spout
M ater i a l s w i th me d i a c onta c t - additional support in case of a thin panel
Rubber: EPDM
For further information, please contact your BROEN LAB
Plastics: PP representative.

w i th remo v a b l e no z z l e
Model / Standout

S
62mm [2 7/16” ]

Media S = 53mm S = 75mm S = 90mm

WDI Distilled water 25111161003-40 25111261003-40 25111361003-40

WDC Deionised water, cold 25111161036-40 25111261036-40 25111361036-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

-12- w w w. b r o e n . c o m
out l et s - SS
S p e c i a l W at e r PREMIUM
Scope of delivery

Addional mounting information


see page 32-35

SS outlet

BROEN UniFlex TM FRONT control valves and OUTLETS


Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
BROEN UniFlexTM outlets have an integrated media For standard configuration please refer to the item
indication according to EN 13792. numbers below.
Inlet: BROEN UniFlexTM Other options:
Max. wall thickness: 20mm
- flange
Weight: 0.5 kg - straight rear wall connection
- fixed nozzle with external G3/4” thread
M ater i a l s w i th me d i a c onta c t - wall thickness 20-40mm
Rubber: EPDM - additional support in case of a thin panel
Metals: Stainless Steel (AISI 316) For further information, please contact your BROEN LAB
representative.

w i th remo v a b l e no z z l e
Model / Standout

S
62mm [2 7/16”]

Media S = 53mm S = 90mm

WDI Distilled water 25111171003-40 25111371003-40

WDC Deionised water, cold 25111171036-40 25111371036-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

w w w. b r o e n . c o m -13-
F ront Contro l v a l v e s
C o o l a n t W at e r PREMIUM

Available with or without


service valve according to
product numbers listed below
BROEN UniFlex TM FRONT control valves and OUTLETS

Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
Handle: Metal, BROEN POLYCOAT powder coated For standard configuration please refer to the item
with media indication according to EN13792. numbers below.
Headwork: Rubber Other options:
Opening/closing function: 2 x 360°
- a valve for front side mounting
Temperature range: 0-90°C - a valve without mounting kit
Max. working pressure: 10 bar / 147 psi - a valve with simple hand operation of flow and return of
Test pressure: 1 x working pressure chilled water
Inlet/outlet: BROEN UniFlexTM For further information, please contact your BROEN LAB
Weight: 0.7 kg representative.

M ater i a l s w i th me d i a c onta c t
Metals: Brass
Rubber: EPDM
Lubricant: Silicone based

Model

Service valve

Media Without service valve With service valve

WCF Coolant water, feed 25115031005 25115041005

WCR Coolant water, return 25115031006 25115041006

Delivered with mounting accessories

-14- w w w. b r o e n . c o m
out l et s
C o o l a n t W at e r PREMIUM
Scope of delivery

Addional mounting information


see page 32-35

Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
BROEN UniFlex outlets have
TM
For standard configuration please refer to the item
an integrated media indication according to EN 13792. numbers below.
Outlets for chilled water are delivered with integrated Other options:
non-return valve.

BROEN UniFlex TM FRONT control valves and OUTLETS


Inlet/outlet: BROEN UniFlexTM - flange
Max. wall thickness: 20mm - other standout
- straight rear wall connection
Weight: 0.5 kg
- wall thickness 20-40mm
M ater i a l s w i th me d i a c onta c t - double wall mounting
Metals: Brass - additional support in case of a thin panel
Rubber: EPDM For further information, please contact your BROEN LAB
Lubricant: Silicone based representative.

w i th remo v a b l e no z z l e
Model / Standout
107mm [4”] S
60mm [2 1/2”]

84mm [3 1/2”]

Media 45° S = 53mm S = 75mm S = 90mm

WCF Coolant water, feed 25111041005-40 25111141005-40 25111241005-40 25111341005-40

WCR Coolant water, return 25111041006-40 25111141006-40 25111241006-40 25111341006-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

w i th qu i c k re l e a s e c oup l i n g
Model / Standout

104mm [4”] S
57mm [2 1/2” ]

89mm [3 1/2”]

Media 45° S = 53mm S = 75mm S = 90mm

WCF Coolant water, feed 25111051005-40 25111151005-40 25111251005-40 25111351005-40

WCR Coolant water, return 25111051006-40 25111151006-40 25111251006-40 25111351006-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

w w w. b r o e n . c o m -15-
F ront Contro l v a l v e s
Burning Gases PREMIUM

Available with or without


service valve according to
product numbers listed below
BROEN UniFlex TM FRONT control valves and OUTLETS

Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
Handle: Metal, BROEN POLYCOAT powder coated For standard configuration please refer to the item
with media indication according to EN13792. numbers below.
Headwork: ceramic, press/turn Other options:
Opening/closing function: 90°
- a valve for different medium
Max.working pressure: 7 bar / 101,5 psi - a valve for front side mounting
Test pressure: 1.5 x working pressure - a valve without mounting kit
Inlet/outlet: BROEN UniFlexTM For further information, please contact your BROEN LAB
Weight: 0.7 kg representative.

M ater i a l s w i th me d i a c onta c t
Metals: Brass
Rubber: NBR
Lubricant: Mineral oil based

Model

Service valve

Media Without service valve With service valve

G Natural gas 25115191010 25115201010

Propane/Butane

LPG
(liquified gases) 25115191012 25115201012

CH
Butane
4 10
25115191014 25115201014

CH
Propane
3 8
25115191016 25115201016

CH
Acetylene
2 2
25115191018 25115201018

Hydrogen
H 2 25115191020 25115201020

Delivered with mounting accessories

-16- w w w. b r o e n . c o m
out l et s
Burning Gases PREMIUM
Scope of delivery

Addional mounting information


see page 32-35

BROEN UniFlex TM FRONT control valves and OUTLETS


Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
BROEN UniFlexTM outlets have an integrated media For standard configuration please refer to the item
indication according to EN 13792. numbers below.
Inlet/outlet: BROEN UniFlexTM Other options:
Max. wall thickness: 20mm
- other media
Weight: 0.5 kg - flange
- other standout
M ater i a l s w i th me d i a c onta c t - straight rear wall connection
Metals: Brass - wall thickness 20-40mm
Rubber: NBR - double wall mounting
- table mounting
Lubricant: Mineral oil based
- additional support in case of a thin panel
For further information, please contact your BROEN LAB
representative.

w w w. b r o e n . c o m -17-
out l et s
Burning Gases PREMIUM

w i th f i x e d no z z l e

Model / Standout

84mm [3” 1/2] S

37mm [1 1/2” ]

52mm [2 3/64”]
Media 45° S = 53mm S = 75mm S = 90mm

G Natural gas 25111001010-40 25111101010-40 25111201010-40 25111301010-40


BROEN UniFlex TM FRONT control valves and OUTLETS

Propane/Butane

LPG
(liquified gases) 25111001012-40 25111101012-40 25111201012-40 25111301012-40

CH
4 10
Butane 25111001014-40 25111101014-40 25111201014-40 25111301014-40

CH
3 8
Propane 25111001016-40 25111101016-40 25111201016-40 25111301016-40

CH
2 2
Acetylene 25111001018-40 25111101018-40 25111201018-40 25111301018-40

H 2 Hydrogen 25111001020-40 25111101020-40 25111201020-40 25111301020-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

w i th qu i c k re l e a s e c oup l i n g

Model / Standout

104mm [4”] S
57mm [2 1/2” ]

89mm [3 1/2”]

Media 45° S = 53mm S = 75mm S = 90mm

G Natural gas 25111021010-40 25111121010-40 25111221010-40 25111321010-40

Propane/Butane

LPG
(liquified gases) 25111021012-40 25111121012-40 25111221012-40 25111321012-40

CH
4 10
Butane 25111021014-40 25111121014-40 25111221014-40 25111321014-40

CH
3 8
Propane 25111021016-40 25111121016-40 25111221016-40 25111321016-40

CH
2 2
Acetylene 25111021018-40 25111121018-40 25111221018-40 25111321018-40

H 2 Hydrogen 25111021020-40 25111121020-40 25111221020-40 25111321020-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

-18- w w w. b r o e n . c o m
F ront Contro l v a l v e s
T e c h n i c a l 2.0 G a s e s / Vac u u m / H i g h F lo w PREMIUM

Available with or without


service valve according to
product numbers listed below

Spe c i f i c at i on s M ater i a l s w i th me d i a c onta c t


Handle: Metal, BROEN POLYCOAT powder coated Metals: Brass
with media indication according to EN13792.
Rubber: FKM
Inlet/outlet: BROEN UniFlexTM
Plastics: PVDF
Weight: 0.7 kg
Lubricant: Perfluoropolyether based
Test pressure: 1.5 x working pressure

BROEN UniFlex TM FRONT control valves and OUTLETS


Technical 2.0 gases O R D E R I N G I N F O R M AT I O N
Headwork: Needle Headwork: Micro flow
For standard configuration please refer to the item
Opening/closing function: Opening/closing function: numbers below.
3 x 360° 7.5 x 360°
Other options:
Max. working pressure: Max. working pressure:
16 bar / 232 psi 16 bar / 232 psi - a valve for front side mounting
- a valve without mounting kit
Vacuum / High Flow
For further information, please contact your BROEN LAB
Headwork: High flow
representative.
Opening/closing function:
1.5 x 360°
Max. working pressure: Please note that valves for vacuum as a standard delivered with a high flow headwork.
-1 bar to 16 bar / High flow headwork can also be used for other media where there is a requirement for
-14.5 psi to 232 psi higher flow.

Model

Without service valve With service valve

Media Needle Micro flow Needle Micro flow


headwork headwork headwork headwork


CA Compressed air 25115111021 25115461021 25115121021 25115471021


N Nitrogen
2
25115111023 25115461023 25115121023 25115471023

CO
Carbogen Dioxide
2 25115111024 25115461024 25115121024 25115471024


Ar Argon 25115111025 25115461025 25115121025 25115471025


He Helium 25115111026 25115461026 25115121026 25115471026

High flow headwork High flow headwork

V Low vacuum (1000 to 1 mbar) 25115151028 2115161028

Delivered with mounting accessories

w w w. b r o e n . c o m -19-
P re s s ure re g u l ator
Technical 2.0 Gases PREMIUM
Inlet: female
BROEN UniFlex™
with a built-in filter
Outlet: female
BROEN UniFlex™
BROEN UniFlex TM FRONT control valves and OUTLETS

Pressure regulators MS4/MS6-LR, MS series


Technical data
Spe c i f i c at i on s f l o w c h a rt
Standard flow rate qn as a function of output pressure p2
BROEN UniFlexTM pressure regulator for panel
MS4-LR- x mounting with Input
MS4-LR-¼ pressure p1 = 10 bar
a built-in filter (mesh size
Input pressure p1 = 10 bar
200 µm) on the inlet.
Inlet pressure: Max. 14 bar

Outlet pressure (p2 ) [bar]


Outlet pressure: 0,5-12 bar
p2 [bar]

Inlet/outlet: BROEN UniFlexTM


Max. panel thickness: 5,5mm
Weight: 0.5 kg

M ater i a l s w i th me d i a c onta c t
D6: 0.3 … 7 bar
Metals: Brass, aluminium 1) qn [l/min] Flow [l/min]
D7: 0.5 … 12 bar
Rubber: NBR
1) There is a higher initial pressure drop for the characteristic curve
the DM1/DM2
of variant.
Plastics: PVDF
Lubricant: Perfluoropolyether based MS6-LR-¼ MS6-LR-y
Input pressure p1 = 10 bar
O R D E R I N G I N F O R M AT I O N
For standard configuration please refer to the item
p2 [bar]

p2 [bar]

numbers below.
For further information and additional options, please
contact your BROEN LAB representative.

D6: 0.3 … 7 bar


D7: 0.5 … 12Model
bar qn [l/min] qn [l/min]

MS6-LR-½
Input pressure p1 = 10 bar
Media*

CA Compressed air 25115611099


p2 [bar]

Nitrogen
N 2 25115611099

CO2 Carbon Dioxide 25115611099


D6: 0.3 … 7 bar
Argon
Ar
D7: 0.5 … 12 bar qn [l/min] 25115611099

* Can be used for CA, N2, CO2, Ar. Not recommended for Helium (He). Do not use for Oxygen (O2)!

-20- w w w. b r o e n . c o m
out l et s
T e c h n i c a l 2.0 G a s e s / Vac u u m / H i g h F lo w PREMIUM

Scope of delivery

Addional mounting information


see page 32-35

BROEN UniFlex TM FRONT control valves and OUTLETS


Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
BROEN UniFlexTM outlets have an integrated media For standard configuration please refer to the item
indication according to EN 13792. numbers below.
Inlet/outlet: BROEN UniFlexTM Other options:
Max. wall thickness: 20mm
- other media
Weight: 0.5 kg - flange
- straight rear wall connection
M ater i a l s w i th me d i a c onta c t - wall thickness 20-40mm
Metals: Brass - double wall mounting
Rubber: FKM - table mounting
- additional support in case of a thin panel
Plastics: PVDF
Lubricant: Perfluoropolyether based For further information, please contact your BROEN LAB
representative.

w i th f i x e d no z z l e
Model / Standout

84mm [3 1/2” ] S
37mm [1 1/2” ]

52mm [2 3/64” ]

Media 45° S = 53mm S = 75mm S = 90mm

CA Compressed air 25111001021-40 25111101021-40 25111201021-40 25111301021-40

N 2
Nitrogen 25111001023-40 25111101023-40 25111201023-40 25111301023-40

CO2 Carbon dioxide 25111001024-40 25111101024-40 25111201024-40 25111301024-40

Ar Argon 25111001025-40 25111101025-40 25111201025-40 25111301025-40

He Helium 25111001026-40 25111101026-40 25111201026-40 25111301026-40

V Low vacuum (1000 to 1 mbar) 25111001028-40 25111101028-40 25111201028-40 25111301028-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

w w w. b r o e n . c o m -21-
out l et s
T e c h n i c a l 2.0 G a s e s / Vac u u m / H i g h F lo w PREMIUM

w i th qu i c k re l e a s e c oup l i n g
Model / Standout

104mm [4”] S

57mm [2 1/2” ]

89mm [3 1/2”]
Media 45° S = 53mm S = 75mm S = 90mm

CA Compressed air 25111021021-40 25111121021-40 25111221021-40 25111321021-40

N Nitrogen 25111021023-40 25111121023-40 25111221023-40 25111321023-40


BROEN UniFlex TM FRONT control valves and OUTLETS

CO2 Carbon dioxide 25111021024-40 25111121024-40 25111221024-40 25111321024-40

Ar Argon 25111021025-40 25111121025-40 25111221025-40 25111321025-40

He Helium 25111021026-40 25111121026-40 25111221026-40 25111321026-40

V Low vacuum (1000 to 1 mbar) 25111021028-40 25111121028-40 25111221028-40 25111321028-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

-22- w w w. b r o e n . c o m
F ront Contro l v a l v e s
T e c h n i c a l 4.0 G a s e s / Ox yg e n PREMIUM

Available with or without


service valve according to
product numbers listed below

Spe c i f i c at i on s m ater i a l s w i th me d i a c onta c t


Handle: Metal, BROEN POLYCOAT powder coated Metals: Brass
with media indication according to EN13792. Rubber: FKM
Inlet/outlet: BROEN UniFlexTM Plastics: PVDF

BROEN UniFlex TM FRONT control valves and OUTLETS


Weight: 0.7 kg Lubricant: Perfluoropolyether based (Oxygen approved)
Test pressure: 1.5 x working pressure All components are ultrasonically cleaned for 99,99% clean
gases
Headwork: Needle
Opening/closing function: 3 x 360° O R D E R I N G I N F O R M AT I O N
Max. working pressure: 16 bar / 232 psi For standard configuration please refer to the item
numbers below.
Headwork: Micro flow Other options:
Opening/closing function: 7.5 x 360°
- a valve for front side mounting
Max. working pressure: 16 bar / 232 psi - a valve without mounting kit

For further information, please contact your BROEN LAB


representative.

Model

Without service valve With service valve

Needle Micro flow Needle Micro flow


Media headwork headwork headwork headwork

CA Compressed air 25115271021 25115501021 25115281021 25115511021

Oxygen
O 2
25115271022 25115501022 25115281022 25115511022

Nitrogen
N 2 25115271023 25115501023 25115281023 25115511023

CO2 Carbon Dioxide 25115271024 25115501024 25115281024 25115511024

Argon
Ar 25115271025 25115501025 25115281025 25115511025

Helium
He 25115271026 25115501026 25115281026 25115511026

N2O Dinitrogen Monoxide 25115271027 25115501027 25115281027 25115511027

Delivered with mounting accessories

w w w. b r o e n . c o m -23-
out l et s
T e c h n i c a l 4.0 G a s e s / Ox yg e n PREMIUM

Scope of delivery

Addional mounting information


see page 32-35
BROEN UniFlex TM FRONT control valves and OUTLETS

Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
BROEN UniFlexTM outlets have an integrated media For standard configuration please refer to the item
indication according to EN 13792. numbers below.
Inlet/outlet: BROEN UniFlexTM Other options:
Max. wall thickness: 20mm
- other media
Weight: 0.5 kg - flange
- removable nozzle
M ater i a l s w i th me d i a c onta c t - other standout
Metals: Brass - straight rear wall connection
Rubber: FKM - wall thickness 20-40mm
- table mounting
Plastics: PVDF
- additional support in case of a thin panel
Lubricant: Perfluoropolyether based (Oxygen approved)
For further information, please contact your BROEN LAB
All components are ultrasonically cleaned for 99,99% clean
representative.
gases

-24- w w w. b r o e n . c o m
out l et s
T e c h n i c a l 4.0 G a s e s / Ox yg e n PREMIUM
w i th f i x e d no z z l e
Model / Standout

84mm [3 1/2” ] S

37mm [1 1/2” ]

52mm [2 3/64” ]
Media 45° S = 53mm S = 75mm S = 90mm

CA Compressed air 25111081021-40 25111181021-40 25111281021-40 25111381021-40

O 2
Oxygen 25111081022-40 25111181022-40 25111281022-40 25111381022-40

BROEN UniFlex TM FRONT control valves and OUTLETS


N 2 Nitrogen 25111081023-40 25111181023-40 25111281023-40 25111381023-40

CO2 Carbon dioxide 25111081024-40 25111181024-40 25111281024-40 25111381024-40

Ar Argon 25111081025-40 25111181025-40 25111281025-40 25111381025-40

He Helium 25111081026-40 25111181026-40 25111281026-40 25111381026-40

N2O Dinitrogen monoxide 25111081027-40 25111181027-40 25111281027-40 25111381027-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

w i th qu i c k re l e a s e c oup l i n g

Model / Standout

104mm [4”] S
57mm [2 1/2” ]

89mm [3 1/2”]

Media 45° S = 53mm S = 75mm S = 90mm

CA Compressed air 25111851021-40 25111861021-40 25111871021-40 25111901021-40

O 2
Oxygen 25111851022-40 25111861022-22 25111871022-22 25111901022-22

N 2 Nitrogen 25111851023-40 25111861023-40 25111871023-40 25111901023-40

CO2 Carbon dioxide 25111851024-40 25111861024-40 25111871024-40 25111901024-40

Ar Argon 25111851025-40 25111861025-40 25111871025-40 25111901025-40

He Helium 25111851026-40 25111861026-40 25111871026-40 25111901026-40

N2O Dinitrogen monoxide 25111851027-40 25111861027-40 25111871027-40 25111901027-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

w w w. b r o e n . c o m -25-
F ront Contro l v a l v e s
Pure 5.0 Gases PREMIUM

Spe c i f i c at i on s M ater i a l s w i th me d i a c onta c t


Valve can be used for non-corrosive and inactive gases with Metals: Brass
purity coefficient up to 5.0 (99.999% pure gases).
Rubber: FKM
Handle: Metal, BROEN POLYCOAT powder coated
Plastics: PVDF
with media indication according to EN13792.
Lubricant: Perfluoropolyether based (Oxygen approved)
BROEN UniFlex TM FRONT control valves and OUTLETS

Inlet/outlet: BROEN UniFlexTM


Leak rate: < 5x10-5 mbar x l/s [Helium] All components are ultrasonically cleaned for 99,999% clean
Weight: 0.7 kg gases
Test pressure: 1.5 x working pressure
O R D E R I N G I N F O R M AT I O N
FLow valves For standard configuration please refer to the item
Headwork: Needle Headwork: Micro flow numbers below.
Opening/closing function: Opening/closing function: Other options:
3 x 360° 7.5 x 360°
- a valve for front side mounting
Max. working pressure: Max. working pressure:
- a valve without mounting kit
21 bar / 305 psi 16 bar / 232 psi
- inlet/outlet with female 1/4 NPT thread

Shut-off Valve For further information, please contact your BROEN LAB
representative.
Headwork: Stop
Opening/closing function:
1.5 x 360°
Max. working pressure:
21 bar / 305 psi

Model

Media Shut-off valve Needle headwork Micro flow headwork

CA Compressed air 25115431021 25115421021 25115521021

O2
Oxygen 25115431022 25115421022 25115521022

N2 Nitrogen 25115431023 25115421023 25115521023

CO2 Carbon Dioxide 25115431024 25115421024 25115521024

Ar Argon 25115431025 25115421025 25115521025

He Helium 25115431026 25115421026 25115521026

Delivered with mounting accessories

-26- w w w. b r o e n . c o m
out l et s
Pure 5.0 Gases PREMIUM
Scope of delivery

Addional mounting information


see page 32-35

Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
Outlets can be used for non-corrosive and inactive gases For standard configuration please refer to the item
with purity coefficient up to 5.0 (99,999% pure gases). numbers below.

BROEN UniFlex TM FRONT control valves and OUTLETS


BROEN UniFlexTM outlets have an integrated media indica-
Other options:
tion according to EN 13792.
Inlet: BROEN UniFlexTM - other media
- flange
Outlet: Female 1/4 NPT
- straight rear wall connection
Leak rate: < 5x10-5 mbar x l/s [Helium] - wall thickness 20-40mm
Max. wall thickness: 20mm - table mounting
Weight: 0.5 kg - additional support in case of a thin panel
- Swagelok® tube fittings
M ater i a l s w i th me d i a c onta c t - inlet with female 1/4 NPT thread
Metals: Brass For further information, please contact your BROEN LAB
Rubber: FKM representative.
Plastics: PVDF
Lubricant: Perfluoropolyether based (Oxygen approved)
All components are ultrasonically cleaned for 99,999% clean
gases.

Model / Standout

84mm [3 1/2” ] S
27mm [1” ]

Media 45° S = 53mm S = 75mm S = 90mm

CA Compressed air 25111091021-40 25111191021-40 25111291021-40 25111391021-40

O 2
Oxygen 25111091022-40 25111191022-40 25111291022-40 25111391022-40

N 2 Nitrogen 25111091023-40 25111191023-40 25111291023-40 25111391023-40

CO2 Carbon dioxide 25111091024-40 25111191024-40 25111291024-40 25111391024-40

Ar Argon 25111091025-40 25111191025-40 25111291025-40 25111391025-40

He Helium 25111091026-40 25111191026-40 25111291026-40 25111391026-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

w w w. b r o e n . c o m -27-
F ront Contro l v a l v e s
Pure 6.0 Gases PREMIUM
BROEN UniFlex TM FRONT control valves and OUTLETS

Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
Valve can be used for non-corrosive and inactive gases with For standard configuration please refer to the item
purity coefficient up to 6.0 (99.9999% pure gases). numbers below.
Handle: Metal, BROEN POLYCOAT powder coated Media should be defined when ordering.
with media indication according to EN13792.
Other options:
Headwork: Diaphragm type
Opening/closing function: 1.5 x 360° - Swagelok® tube fittings
Max. working pressure: 21 bar / 305 psi For further information, please contact your BROEN LAB
Test pressure: 1.5 x working pressure representative.
Inlet/outlet: Female 1/4” NTP thread
Leak rate: < 10-7 mbar x l/s [Helium]
Weight: 0.7 kg

M ater i a l s w i th me d i a c onta c t
Metals: Brass
Plastics: PVDF
Diaphragm: Stainless Steel Alloy

Model

Media Stop valve Flow valve

All media 02 460.009-9023 02 462.009-9023

Delivered with mounting accessories

-28- w w w. b r o e n . c o m
out l et s
Pure 6.0 Gases PREMIUM

Swagelok® tube fittings


must be ordered separately

BROEN UniFlex TM FRONT control valves and OUTLETS


Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
Outlets can be used for non-corrosive and inactive gases For standard configuration please refer to the item
with purity coefficient up to 6.0 (99,9999% pure gases). numbers below.
Inlet/outlet: Female 1/4 NPT thread Swagelok® tube fittings must be ordered separately.
Leak rate: < 10-7 mbar x l/s [Helium] For further information, please contact your BROEN LAB
Weight: 0.5 kg representative.

M ater i a l s w i th me d i a c onta c t
Metals: Brass (Stainless Steel for bulk head union outlet)

Models

Media 45° Straight Bulk head union outlet

All media 02 869.529-9023 02 861.529-9023 02 566.009-9023

Delivered with 90° rear wall connection (max wall thickness 20mm)

w w w. b r o e n . c o m -29-
F ront Contro l v a l v e s
Corrosive Gases PREMIUM
BROEN UniFlex TM FRONT control valves and OUTLETS

Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
Valve can be used for corrosive gases with purity coefficient For standard configuration please refer to the item
up to 6.0 (99.9999% pure gases). numbers below.
Handle: Metal, BROEN POLYCOAT powder coated Media should be defined when ordering.
with media indication according to EN13792.
Other options:
Headwork: Diaphragm type
Opening/closing function: 1.5 x 360° - a valve without mounting kit
Max. working pressure: 16 bar / 232 psi For further information, please contact your BROEN LAB
Test pressure: 1.5 x working pressure representative.
Inlet/outlet: SS tubes for OD 8mm
Leak rate: < 10-7 mbar x l/s [Helium]
Weight: 0.7 kg

M ater i a l s w i th me d i a c onta c t
Metals: Stainless Steel (AISI 316L)
Plastics: PVDF

Model

Media Without service valve

Corrosive gases 25115391099

Delivered with mounting accessories

-30- w w w. b r o e n . c o m
out l et s
Corrosive Gases PREMIUM

Scope of delivery

Addional mounting information


see page 32-35

BROEN UniFlex TM FRONT control valves and OUTLETS


Spe c i f i c at i on s O R D E R I N G I N F O R M AT I O N
Outlets can be used for corrosive gases with purity For standard configuration please refer to the item
coefficient up to 6.0 (99.9999% pure gases). numbers below.
BROEN UniFlexTM outlets have an integrated media Media should be defined when ordering.
indication according to EN 13792.
Other options:
Inlet: OD 8mm / ID 6mm
Leak rate: < 10-7 mbar x l/s [Helium] - flange
- wall thickness 20-40mm
Max. wall thickness: 20mm - additional support in case of a thin panel
Weight: 0.6 kg
For further information, please contact your BROEN LAB
representative.
M ater i a l s w i th me d i a c onta c t
Metals: Stainless Steel (AISI 316L)
Plastics: PVDF

w i th f i x e d no z z l e
Model / Standout

S
52mm [2 3/64” ]

Media S = 53mm S = 75mm S = 90mm

Corrosive gases 25111501099-40 25111511099-40 25111521099-40

Delivered with 90° rear wall connection (max wall thickness 20mm)

w w w. b r o e n . c o m -31-
M ount i n g A c c e s s or i e s
PREMIUM

Illustration Description Media BROEN


item No.
Ø41mm

Flange (wall thickness 20-40mm) All media 1521057G


Ø41mm

Flange (wall thickness 20-40mm) All media 1521178G


BROEN UniFlex TM FRONT control valves and OUTLETS

Nut (wall thickness 20-40mm) All media 1521054

Nut (max. wall thickness 20mm) All media 1521036

34mm

Straight rear wall connection Water, burning and 1521088


2.0 technical gases
22mm

90° rear wall connection Water, burning and 1521052


40mm

2.0 technical gases

Backside support All media 1521092

Rear wall connection for fume hoods Water, burning and


M with a double wall construction 2.0 technical gases
22mm

40mm

M = 49 to 61 mm 2511494
M = 61 to 73 mm 2511497
M = 73 to 85 mm 2511496
M = 85 to 97 mm 2511495
M = 97 to 109 mm 2511493

Test equipment for outlets 2.0 technical gases 1521177

-32- w w w. b r o e n . c o m
M ount i n g i n s tru c t i on s
ALL M E DIA PREMIUM

F ront c ontro l v a l v e s

Max. 30mm

43mm

M40x1.5 Drill Ø41mm

BROEN UniFlex TM FRONT control valves and OUTLETS


1) 2)

Tighten the mounting


nut with hand

O U t l et s
Flange (optional)
Mandatory on soft wall materials 1)
Max. 20mm
Max. 18mm incl. flange

25Nm

Wall thickness
less than 20mm
Drill Ø18mm
hole in wall

2)
Wall thickness
20-40mm

Drill Ø22mm
hole in wall

Flange (optional)
Mandatory on soft wall materials
Tighten Allen screws with
Allen key, max. 1Nm

w w w. b r o e n . c o m -33-
M ount i n g i n s tru c t i on s
PREMIUM
M O U N T I N G O F O U T L E T S I N T O F U M E H O O DS
WI T H A D O U B L E WALL C O N S T R U C T I O N

1) Insert the rear wall connection through the back wall 2) Fix the outlet to the back wall by tightening the nut 4) Position the outlet

3) Place the front wall

Drill Ø28mm hole


5) Tighten Allen screws
with Allen key, max 1Nm
BROEN UniFlex TM FRONT control valves and OUTLETS

P I P E I N S TALLAT I O N
WAT E R / S P E CIAL WAT E R ( SS M O D E L ) /
T E C H N ICAL A N D B U R N I N G GAS E S ( 4 . 0 A N D 5 . 0 GAS E S )

BROEN front control valves and fume hood outlets for standard media are delivered with BROEN UniFlexTM inlet connections
as well as outlet connection on the valves.

Va lv e OUTLET

BROEN UniFlexTM connection

Pipe installation can be done either with flexible hoses or with standard Cu, PEX or SS pipes.
BROEN has a wide range of flexible hoses available with BROEN UniFlexTM connections as well as connection fittings to fit
pipes of the following sizes:
- OD 8mm
- OD 10mm BROEN UniFlexTM flexible hoses
- OD 12mm
- OD 15mm
- 3/8”

BROEN UniFlexTM connection fittings and adaptors


for Cu, SS, PEX and PA pipes

For further information about flexible hoses and connection fittings, please contact you local BROEN LAB representative or
refer to www.broen.com

-34- w w w. b r o e n . c o m
P I P E I N S TALLAT I O N
Spe c i a l W ater ( P P mo d e l s on ly ) PREMIUM

Please note that PP valves and outlets for special water are delivered with push-in fittings.
BROEN recommends the following materials for pipe installation:

Va lv e OUTLET

BROEN UniFlex TM FRONT control valves and OUTLETS


Push-in fittings for OD10mm plastic tubing (10x1mm)

BROEN recommends the following materials for pipe installation:


- Nylon (PA, can be purchased at BROEN), PE, PUR, PVDF
For further information, please contact your BROEN LAB representative or refer to www.broen.com

C O R R O SIV E GAS E S

Please note that valves and outlets for corrosive gases are delivered in stainless steel and are prepared for orbital welding.
In case of outlet, welding process should take place before mounting into the fume hood.

Va lv e OUTLET

OD 8mm / ID 6mm

For further information, please contact your BROEN LAB representative or refer to www.broen.com

w w w. b r o e n . c o m -35-
BROEN LAB develops, manufactures and delivers complete
range of fittings for professional laboratories. Our know-how
and our quality products ensure the precise flow of water,
gases and air, from source to user.

BROEN LAB solutions are used by professional users in many


kinds of laboratories, from the education and health sectors
to industry in general. Our products are already an integrated
part of many workplaces. From fittings for purified water,
nitrogen, vacuum and compressed air, to the control and
regulation of pure gases in critical applications such as a gas
chromatography and spectrometry.

Our extensive knowledge allows us to continually develop


and optimize our products so that they meet customer needs
and specifications. Safety, functionality and quality are an
integral part of product design and flexibility. Our insight and
understanding of working environments and safety in
laboratories allow us to develop custom solutions for projects
around the world. Use us to plan your project so we can
advise you on laboratory layout and design.

HEAD OFFICE INTERNATIONAL OFFICES

BROEN LAB GROUP BROEN Armaturen GmbH


Skovvej 30 • DK-5610 Assens Industriestrasse 8 • D - 64579 Gernsheim • Germany
Tel. +45 6471 2095 • Fax +45 6471 2476 Tel. +49 6258 9319-0 • Fax +49 6258 51812

99B0040 BROEN UNIFLEXTM Front control valves and OUTLETS - PREMIUM 10-06-2013
E-mail: lab@broen.com E-mail: info@broen.de

BROEN VALVES Ltd.


7, Cleton Street Business Park, Cleton Street
Tipton • West Midlands DY4 7TR • U.K.
Tel. +44 121 522 4515 • Fax +44 121 522 4535
E-mail: broenvalves@broen.com

BROEN LAB GROUP ISO 9001 certification BROEN Singapore Pte. Ltd.
In September 1991 BROEN LAB GROUP was certified 10 Bukit Batok Cresent #10-02 • The Spire S(658079) • Singapore
according to ISO 9001 as one of the first Danish companies. Tel: +65 6298 0662 • Fax: +65 6298 0468
The certification was carried out by Bureau Veritas, Denmark, E-mail: sales@broen.com.sg
for our Danish site at Assens.
The quality management system of BROEN LAB
GROUP now complies with detailed specifications laid down
by the internationally acknowledged EN ISO 9001:2008.
This certification will further contribute to BROEN LAB GROUP’s
reputation for quality and reliability.

www.broen.com