You are on page 1of 10

PT.

PesatServisIndustri Man Power Supply – Oil and Gas


Corrosion and Cathodic Protection
Lightning Prevention Systems
Industrial Services Solution Advance NDT Services

REPORT OF
POSITIVE MATERIAL IDENTIFICATION
(PMI)

PT. Pesat Servis Industri


FOR

PT. TRACON INDUSTRI

(PJB REMBANG)

Date, Apr 5th, 2018

PT. PESAT SERVIS INDUSTRI


Jln.Raya,Pamulang II, No 26, Tangerang, Indonesia 15416,
Phone : 021 – 74639172, Fax : 021 – 74639172
Email : admin@pesatservisindustri.com, Web : www.pesatservisindustri.com

Jln.Raya,Pamulang II, No 26, Tangerang, Indonesia 15416, Phone : 021 – 74639172, Fax : 021 – 74639172
Email :admin@pesatservisindustri.com, Web : www.pesatservisindustri.com
PT. PesatServisIndustri Man Power Supply – Oil and Gas
Corrosion and Cathodic Protection
Lightning Prevention Systems
Industrial Services Solution Advance NDT Services

TABLE OF CONTENT

1. Introduction
2. Reference Documents
3. Personnel
4. Equipment
5. Calibration
6. Surface Preparation
7. Safety
8. Customer & Data Information
9. PMI Test and Data Sheet Result
Appendix :
- Equipment Certificate

Jln.Raya,Pamulang II, No 26, Tangerang, Indonesia 15416, Phone : 021 – 74639172, Fax : 021 – 74639172
Email :admin@pesatservisindustri.com, Web : www.pesatservisindustri.com
PT. PesatServisIndustri Man Power Supply – Oil and Gas
Corrosion and Cathodic Protection
Lightning Prevention Systems
Industrial Services Solution Advance NDT Services

1. INTRODUCTION
The purpose of Positive Material Identification (PMI) testing is to identify materials
using PMI equipment (optical emission spectrometer or XRF method). The testing is
to assure that materials are properly identified to their alloy type and according to
client’s specification.

2. REFERENCEDOCUMENTS
 ASME II A, B,C
 Material Specification/Mill material certificate
 X-MET 7500 User Manual

3. PERSONNEL
The personnel shall be able to demonstrate their ability to correctly use the
equipment and do the testing in compliance with PMI procedure.

4. EQUIPMENT
XMET 7500 type is used to detect and verify all types of Chemical Composition of
material except for Carbon, Phosporous, Sulphur and Silicon

5. CALIBRATION
Calibration certificate of equipment shall be available for client’s verification.

6. SURFACEPREPARATION
Material surface shall be free from any other material (paint, coating, oxide scale
etc.) which would hinder accurate test results.

7. SAFETY
All PMI personnel shall be wear minimum PPE and work under company safety
procedure.

Jln.Raya,Pamulang II, No 26, Tangerang, Indonesia 15416, Phone : 021 – 74639172, Fax : 021 – 74639172
Email :admin@pesatservisindustri.com, Web : www.pesatservisindustri.com
PT. PesatServisIndustri Man Power Supply – Oil and Gas
Corrosion and Cathodic Protection
Lightning Prevention Systems
Industrial Services Solution Advance NDT Services

8. Costumer & Data Information

Client : PT.TRACON
Project :
Location : PJB Rembang
Date ofPMITest : Apr5th ,2018

Name of Part/Material to be PMI tested :

No. Description Heat Qty Point


PIPE, STPA 22 (JIS G3458), ID=57.26
1 MM; OD =76.3 MM, 9.52 MM (SCH HN 367004 1 1
160) - 1
PIPE, STPA 22 (JIS G3458), ID=57.26
2 MM; OD =76.3 MM, 9.52 MM (SCH HN 367004 1 1
160)- 2
PIPE, STPA 22 (JIS G3458), ID=57.26
3 MM; OD =76.3 MM, 9.52 MM (SCH HN 367004 1 1
160)- 3
PIPE, STPA 22 (JIS G3458), ID=57.26
4 MM; OD =76.3 MM, 9.52 MM (SCH HN 367004 1 1
160) - 4
PIPE, STPA 22 (JIS G3458), ID=57.26
5 MM; OD =76.3 MM, 9.52 MM (SCH HN 367004 1 1
160)- 5
PIPE, STPA 22 (JIS G3458), ID=57.26
6 MM; OD =76.3 MM, 9.52 MM (SCH HN 367004 1 1
160)- 6
PIPE, STPA 22 (JIS G3458), ID=57.26
7 MM; OD =76.3 MM, 9.52 MM (SCH HN 367004 1 1
160)- 7
PIPE, STPA 22 (JIS G3458), ID=57.26
8 MM; OD =76.3 MM, 9.52 MM (SCH HN 367004 1 1
160)- 8
PIPE, STPA 22 (JIS G3458), ID=57.26
9 MM; OD =76.3 MM, 9.52 MM (SCH HN 367004 1 1
160)- 9
PIPE, STPA 22 (JIS G3458), ID=57.26
10 MM; OD =76.3 MM, 9.52 MM (SCH HN 367004 1 1
160)- 10
10 10
Total :
Point Point

Jln.Raya,Pamulang II, No 26, Tangerang, Indonesia 15416, Phone : 021 – 74639172, Fax : 021 – 74639172
Email :admin@pesatservisindustri.com, Web : www.pesatservisindustri.com
PT. PesatServisIndustri Man Power Supply – Oil and Gas
Corrosion and Cathodic Protection
Lightning Prevention Systems
Industrial Services Solution Advance NDT Services

9. PMI Test and Data Result

Photograph of PMI test executed and Data Sheet Result presented as follow

Jln.Raya,Pamulang II, No 26, Tangerang, Indonesia 15416, Phone : 021 – 74639172, Fax : 021 – 74639172
Email :admin@pesatservisindustri.com, Web : www.pesatservisindustri.com
PT. PesatServisIndustri Man Power Supply – Oil and Gas
Corrosion and Cathodic Protection
Lightning Prevention Systems
Industrial Services Solution Advance NDT Services

PHOTOGRAPH OF PMI TEST

Jln.Raya,Pamulang II, No 26, Tangerang, Indonesia 15416, Phone : 021 – 74639172, Fax : 021 – 74639172
Email :admin@pesatservisindustri.com, Web : www.pesatservisindustri.com
PT. PesatServisIndustri Man Power Supply – Oil and Gas
Corrosion and Cathodic Protection
Lightning Prevention Systems
Industrial Services Solution Advance NDT Services

PMI Data Sheet Result

Jln.Raya,Pamulang II, No 26, Tangerang, Indonesia 15416, Phone : 021 – 74639172, Fax : 021 – 74639172
Email :admin@pesatservisindustri.com, Web : www.pesatservisindustri.com
PT. PesatServisIndustri Man Power Supply – Oil and Gas
Corrosion and Cathodic Protection
Lightning Prevention Systems
Industrial Services Solution Advance NDT Services

Appendix
- Equipment Certificate

Jln.Raya,Pamulang II, No 26, Tangerang, Indonesia 15416, Phone : 021 – 74639172, Fax : 021 – 74639172
Email :admin@pesatservisindustri.com, Web : www.pesatservisindustri.com
PT. PesatServisIndustri Man Power Supply – Oil and Gas
Corrosion and Cathodic Protection
Lightning Prevention Systems
Industrial Services Solution Advance NDT Services

Jln.Raya,Pamulang II, No 26, Tangerang, Indonesia 15416, Phone : 021 – 74639172, Fax : 021 – 74639172
Email :admin@pesatservisindustri.com, Web : www.pesatservisindustri.com
PT. PesatServisIndustri Man Power Supply – Oil and Gas
Corrosion and Cathodic Protection
Lightning Prevention Systems
Industrial Services Solution Advance NDT Services

Jln.Raya,Pamulang II, No 26, Tangerang, Indonesia 15416, Phone : 021 – 74639172, Fax : 021 – 74639172
Email :admin@pesatservisindustri.com, Web : www.pesatservisindustri.com

You might also like