You are on page 1of 7

Unit 3:-

1. Generic name of the endosteal implants was given by

a. Mish& fish

b. Fish & fissure

c. Mish & mish

d. All the above

2. Endosteal implants are designed to engage the ____________ part of the bone

a. Horizontal

b. Vertical

c. Cross section

d. All the above

3. Below all are the different categories of endosteal implants except

a. Cylindrical form

b. Screw form

c. Ramus form

d. Combination of screw and cylindrical form

4. Best way to increase the retention of cylindrical shape implant is

a. Placing it deep inside the bone

b. Pushing it into the bone

c. Applying the gum

d. Surface conditioning

5. Coating or surface conditioning will increase the _______________ retention between implant and bone

a. Mechanical

b. Micro

c. Macro

d. All the above

6. Surface coating is most useful in ___________ type of implants to get retention

a. Cylindrical shaped

b. Screw shaped

c. Both the above

d. None the above

7. In screw design implants, retention is mainly achieved by

a. Mechanical retention

b. Macro retention
c. Micro retention

d. None of the above

8. Which is not a part of a dental implant

a. Abutment

b. Apex

c. Body

d. Crest module

9. The part of the Implant which will help in attaching to the bone is

a. Crest module

b. Apex

c. Body

d. All the above

10. The part of the Implant which will help in holding the prosthesis is

a. Crest module

b. Apex

c. Body

d. All the above

11. The implant component which will help in transfer the position of the implant from patient mouth to the
impression is

a. Abutment

b. Coping

c. Transfer coping

d. Laboratory analog

12. The implant component which will represent the implant body in the master cast is called as

a. Implant body

b. Laboratory analog

c. Impression coping

d. Clinical analog

13. If implant body and abutment is attached together it is called as a

a. Two piece implants

b. One piece implant

c. Three piece implant

d. All are correct

14. Two stage implant surgery is used to place __________type of implants

a. One piece implant system


b. Two piece implant system

c. Three piece implant system

d. All the above

15. Implant component which will help in preventing the tissue growth into the implant body is called as

a. Healing cap

b. Abutment

c. Covering screw

d. All the above

16. Implant component which will help to create emerging profile is

a. Healing cap

b. Abutment

c. Covering screw

d. All the above

17. Implant component which will help in retain the abutment to implant body is

a. Healing cap

b. Abutment

c. Covering screw

d. Prosthesis retaining screw

II. fill in the banks

1. Implant components are arranged in a order of ______________________

2. Generic language of endosteal implants was developed by___________________

3. Implants which will help to engage the vertical column of the bone is called as a______________

4. Spraying ______________ will help to increase the micro retention between implant and bone

5. Implant body component which is smoothly polished is _________

6. Metal framework which will help to provide retention for removable prosthesis is ________________

7. Implant component which will help o transfer implant position into impression is called as a____________

8. Implant component which will help to locate the implant position in master cast is called as a ________

9. One piece implant system is used _____________ implant surgery

10. Two stage implant surgery is used to place ____________________ implant system

11. Implant component which is placed inside the patient mount during first stage surgery is __________

III. Write short notes

1. Write the types in endosteal implant system?

2. Mention the different parts in body of endosteal implant?

3. Write about different implant surgeries?


4. Write the implant components in their chronological order?

5. Write the different implant systems?

Iv. Match the below

1. Implant body a. Help to close the hole

2. Laboratory analog b. Help to generate the emerging profile

3. Impression coping c. Placed inside the patient mouth on first stage


surgery
4. Healing screw
d. Represent implant in master cast
5. Covering screw
e. Help to transfer the implant position from
patient mouth

Unit 4:-

1. Main requirement for patent to go under surgical treatment is

a. Money

b. Esthetics

c. Medically fit

d. Nothing

2. The implant surgery should be conducted under

a. Air conditioner

b. Open area

c. Sterile condition

d. Home

3. Chlorhexidine will help in

a. Make skin beautiful

b. Killing germs around mouth

c. Healing the wound

d. None of the above

4. Manufacturer will supply implants in a

a. Non sterile titanium container

b. Sterile titanium container

c. Non sterile steel container

d. Open bottle

5. Removing the heat generated when drilling the bone can be achieved by using the

a. Saliva
b. Blood

c. Cool saline

d. No need to use anything

6. Excess heat generation while drilling a hole in the bone will lead to

a. Failure of the implant

b. Bone necrosis

c. Bond growth

d. A and b

7. In implant surgery, Slow speed hand piece will be used to

a. Make a hole in the bone

b. To insert implant body into the bone

c. To reshape the bone

d. All the above

8. When doing implant surgery, high speed hand piece will be used to

a. Make a hole in the bone

b. To insert implant body into the bone

c. To reshape the bone

d. All the above

9. In implant stage one surgery, Surgical guide is used to

a. Protect the implant

b. To locate the future implant position

c. To create emerging profile

d. No need to use

10. In implant surgery, implant body will be inserted into the bone in

a. Stage 3 surgery

b. Stage 1 surgery

c. Stage 2 surgery

d. All the above

11. First drill is used in implant surgery is

a. 2mm twist drill

b. Guide drill

c. 3 mm drill

d. countersink drill

12. drill which will help in expand the bone for implant crest module is
a. 2mm twist drill

b. Guide drill

c. 3 mm drill

d. countersink drill

13. drill which will be used along with surgical guide is

a. 2mm twist drill

b. Guide drill

c. 3 mm drill

d. countersink drill

14. first drill which will used with the slow speed hand piece is

a. 2mm twist drill

b. Guide drill

c. 3 mm drill

d. Bone tap

15. Implants are inserted into the bone at the speed of

a. 1500-2000 rpm

b. 15-20 rpm

c. 50-70 rpm

d. All the above

16. Implant component which will help to carry implant body from package to patient mouth is

A. 2mm twist drill

B. Guide drill

C. Fixture mount

D. countersink drill

17. instrument which will help in final tightening the implant body inside the bone is

a. wrench

b. Guide drill

c. Fixture mount

d. countersink drill

18. instrument which help to place the cover screw in the implant body is

a. wrench

b. screwdriver

c. Fixture mount

d. countersink drill
19. stage 2 implant surgery in mandible will be carried after

a. 3 to 4 months

b. 5 to 6 months

c. 8 to 10 months

d. All the above

20. Instrument which will help in preventing the application of torque to the implant is

a. wrench

b. screwdriver

c. Fixture mount

d. Abutment clamp

You might also like