You are on page 1of 1

Daniel PROJECT : PAGE :

CLIENT : DESIGN BY :
Tian Li JOB NO. : DATE : REVIEW BY :
Fastener Anchorage in Combined Stresses Based on ACI 530 & CBC

INPUT DATA & DESIGN SUMMARY


MASONRY STRENGTH
fm ' = 1.5 ksi
FASTENER YIELD STRESS
fy = 60 ksi
TENSION STRESS, ASD
ba = 0.42 kips / ft 12
SHEAR STRESS, VERTICAL
bv,V = 1 kips / ft
SHEAR STRESS, HORIZONTAL
bv,H = 0.85 kips / ft
WALL THICKNESS
b = 8 in
FASTENER DIAMETER f = 1/2 in
EFFECTIVE EMBEDMENT Lb = 5 in [THE ANCHORAGE DESIGN IS ADEQUATE.]
EDGE DISTANCE TO WALL TOP Lbe = 16 in
FASTENER SPACING S = 12 in, o.c.
LOAD TYPE (1=SEISMIC, 0=WIND, 5=GRAVITY) 1 Seismic

ANALYSIS
CHECK MIN. EMBEDMENT (ACI 530 2.1.4.2.1)
Lb,min = MIN[ 4f , 2] = 2.00 in < Lb [SATISFACTORY]

CHECK TENSION CAPACITY FOR A FASTENER (ACI 530 2.1.4.2.2 & CBC 2107A.1.5.2)
Ba = MIN[ 0.5Ap(fm')0.5 , 0.2Abfy] = 1.52 kips / fastener
> k S ba [SATISFACTORY]
Where L = MIN[ Lb , Lbe] = 5.00 in
q = COS (0.5S / L) =
-1
0.00 rad
Aseg = L2 [ q - 0.5 SIN(2q)] = 0.00 in2
2
Ap = p L2 - 2Aseg = 78.54 in

Ab = p f2 / 4 = 0.20 in2
k = 1.4 (3/4) = 1.05 Seismic , (IBC 2003 1620.2 & CBC 1633.2.8.1)

CHECK SHEAR CAPACITY (ACI 530 2.1.4.2.3 & CBC 2107A.1.5.3)


Bv = MIN[ (F)350(Abfm')1/4 , 0.12Abfy] = 1.41 kips / fastener
> S bv,V , Gravity only [SATISFACTORY]
> k S bv , Combined shear [SATISFACTORY]
Where F = [MIN(Lbe , 12f) -1] / (12f - 1) = 1.000
0.5
bv = (bv,V + bv,H) = 1.312 kips / ft

CHECK COMBINED SHEAR AND TENSION CAPACITY (ACI 530 2.1.4.2.4 & CBC 2107A.1.5.4)
S ba / Ba + S bv / Bv = 1.20 < 4/3 [SATISFACTORY]