You are on page 1of 1

ABSTRACT

Prabadi, P. 2015. The Structural Redesign of IRNA and Isolation Building of


Syarifah Ambami Rato Ebu Hospital, Bangkalan. Final Project, Civil
Engineering Department, State Polytechnic of Malang. Advisor:
Qomariah, BS., MT.

The ±1,235.5 m2 building, was of 2 floor with gable frame structure and
rinforced concrrete. The writer intends to redesign it into 3 floors using steel trusses
to make an alternative design of the construction.
The concrete structure planning was redesigned based on the technical
drawings with concrete quality fc’ 30 MPa with refrence to SNI 03 – 2847 – 2002
and steel quality (fy) 240 MPa and 400 MPa with refrence to SNI 03 – 1729 – 2002.
STAAD-Pro V8i applications was for calculations of concrete and steel and
AutoCAD 2007 was for the technical drawings.
The redesign results in 60x60x6 double angle and Ø12mm wind brace;
30/55cm secondary beam using 4D16 upper steel bar and 2D16 bottom steel bar;
30/60cm main beam using 8D19 upper steel bar and 2D19 bottom steel bar; 40/40
cm column using 16D19 main steel bar and Ø10-300mm stirrup steel bar; 12-cm-
deep stairs slab using D16-200mm main steel bar and Ø10-125mm distribution
steel bar; 128x128cm pile cap foundation using D19-125mm main steel bar. It can
be concluded that the redesign is respectively safe.

Keywords.Redsign, reinforce concrete, 3 floors, steel truss.