TABLE 5—VARIOUS SCREENS AND THE DEFECTS THEY DETECT
Screen Detected defects Test conditions
Temperature cycling Die-substrate faults, sealing defects, cracks Alternating cycles of hot and cold temperature of 140 to +125°C; 20 cycles; dwell time in substrate minimum 10 minutes, preferably 30 minutes at temperature extremes; rate of temperature change should be 5 to 10°C per minute. Elevated temperature burn-in test Wire-bond defects, metallization faults 70°C for 24 to 168 hours Stabilization bake Metallization faults, defects in silicon Resistance to soldering heat Thermal degradation, change in electrical 65°C for 106 Component immersed in solder bath at 2606 62 sec characteristics, mechanical stress due to application of heat Thermal shock Thermomechanical stress-induced damage 140 to +125°C for 20 cycles to seal and structural elements, leakage of filling materials, delamination, change in electrical characteristics High-temperature storage Contact defects, ingress of moisture, 150°C for plastic devices, 250°C for hermetically sealed devices for 24 hours oxidation, metallization defects, thermal aging, softening, physical changes High-temperature/high-humidity Closely simulates actual field operating 85°C, 85% relative humidity storage test conditions High-temperature/high-humidity Closely simulates actual field operating 85°C, 85% relative humidity, application of reverse bias bias test conditions, effect of applied bias is observable Salt-spray test Simulates coastal climate, tests resistance Spray mist of 5% salt solution in water in an environmental chamber for 24 hours to corrosion of metallic parts and coatings Moisture-resistance test Effect of humidity, resistance to corrosion Subject unit under test to alternate cycles of dampness and drying while cycling of contacts and wires the temperature Water-immersion test Sealing defects, corrosion of metal Immerse unit under test in water or salt solution at several temperatures of 0 to 35°C Humidity test Corrosion of metallization, chemical action Subject unit under test to 90 to 95% relative humidity at of pollutants in presence of moisture, 40°C for 96 hours absorption of moisture, electrolytic corrosion of joints of dissimilar metals Seal-leak test Defects in package seal Fill package with a gas under pressure, immerse in a liquid to find any leakage Parametric measurements Ionic contamination, surface defects, bond- (before burn-in) wire defects, metallization faults Parametric measurements Changes in electrical characteristics (after burn-in) Electrical-overstress test Testing at bias levels higher than those Application of voltage in increasing steps from normal to 25 or 50% above normal expected during use exposes infant- while holding temperature above ambient mortality cases Vibration test Loose parts, wear and tear, solder joints, Vibrate unit under test from 20 Hz to 2 kHz or at the frequencies of expected fatigue, bonding defects, mechanical faults operation in the device, noise Mechanical-shock drop test, Mechanical damage, leakage of electrolyte Depends on application requirement constant acceleration due to sealing defect, change in electrical characteristics, adhesion faults, bonding defects, cracks in substrate, mechanical strength