You are on page 1of 1

Customer : ONE Manual : ASM

Type : A318/A319/A320/A321 Selected applicability : 401-401


Rev. Date : Nov 01, 2018
28-42-01 SCH 01 P 0001 SHEET 1 - BLOCK DIAGRAM

1 2 3 4 5 6 7 8 9 10

C UPPER ENGINE/WARNING
DISPLAY UNIT (TYPICAL)

540AB
A
A (640AB)
C
A
148AZ D
147AZ
B
ACCESS
DOOR 811 FQIC 3QT
B
PRINTED IN FRANCE

TYPICAL CADENSICON 19QT1 (2) AND 20QT 92VU 4WT1


DU-ECAM, UPPER
31-63
ACCESS:- 19QT1 (2) - 540AB(640AB)
20QT - 147AZ B TOTAL FUEL
ON BOARD (FOB)
FUNCTION:- THE CADENSICON CONTINUOUSLY
MONITORS THE DENSITY AND THE ELECTRICAL
DIELECTRIC CONSTANT OF THE FUEL IN THE
FWD ELECTRONICS RACK 90VU
D SYSTEM DISPLAY
(TYPICAL)
TANK. IT OUTPUTS ANALOGUE SIGNALS FROM
WHICH THE FQIC CALCULATES THE FUEL MASS.
C
ARINC
429

5QT
PRESELECTOR

ARINC E
429
FUEL QUANTITY
INDICATIONS
D (INDIVIDUAL TANKS)

TYPICAL FUEL QUANTITY PROBE (21QT THRU 39QT)


TYPICAL FUEL QUANTITY INDICATING COMPUTER
(FQIC) 3QT
ACCESS:- 4WT2
21QT1(2) THRU 26QT1(2) - 540AB(640AB) DU-ECAM, LOWER
27QT1(2) TO 28QT1(2) - 540BB(640BB)
29QT1(2) - 540DB(640DB)
ACCESS:- 811 (FWD ELECTRONICS RACK 90 VU)
FUNCTION:- THE PROBES AND THE CADENSICON
F 31-63
30QT1(2) - 540FB(640FB)
31QT1(2) - 540GB(640GB) SEND ANALOGUE FUEL QUANTITY, DENSITY AND
TEMPERATURE SIGNALS TO THE FQIC. THE FQIC FUEL TEMPERATURE
32QT1(2) - 540HB(640HB) (INNER CELL)
33QT1(2) - 540LB(640LB) CONTINUOUSLY MONITORS THESE SIGNALS AND
34QT1(2) - 540QB(640QB) GENERATES RELATED DIGITAL DATA. THE CENTRAL
35QT THRU 39QT - 147AZ(148AZ) PROCESSOR UNIT (CPU) OF THE FQIC PROCESSES
E THIS DATA AND CALCULATES THE FUEL MASS.
FUNCTION:- THE PROBE IS A CAPACITIVE ARINC 429 CODES FROM THE AIRDATA/INERTIAL FUEL TEMPERATURE
DEVICE INSTALLED IN THE FUEL TANK. THE REFERENCE SYSTEM ARE USED TO ADJUST THE (OUTER CELL)
COMPUTERIZED DRAWING

FUEL MAKES THE DIELECTRIC OF THE FUEL MASS DATA IN RELATION TO ROLL AND
CAPACITOR. AS THE QUANTITY OF FUEL IN THE PITCH MOVEMENT. THE RESULT IS ACTUAL FUEL TYPICAL FUEL QUANTITY INDICATOR (FQI) 6QT
TANK CHANGES, THE CAPACITANCE OF THE PROBE MASS DATA WHICH IS CHANGED TO ARINC 429
CHANGES. THE FQIC MONITORS THE CAPACITANCE FORMAT FOR:
TO GIVE A VISUAL FUEL QUANTITY INDICATION. - THE ECAM AND FWC ACCESS:- 192MB
- THE INDICATORS AND PRESELECTOR(S).
A RECTIFYING DIODE IN 22QT1(2) AND 33QT1(2) THE FQIC BUILT IN TEST EQUIPMENT (BITE) (FQI) GETS ARINC 429 DATA FROM THE FQIC.
GIVES FUEL TEMPERATURE INFORMATION TO THE CONTINUOUSLY MONITORS THE COMPONENTS OF THE FQI DECODES THE ARINC DATA AND GIVES
FQIC. THE DIODE CAUSES A VOLTAGE DROP IN A THE FUEL QUANTITY INDICATION AND TANK A VISUAL INDICATION (NUMERIC) OF THE
SIGNAL FROM THE FQIC,WHICH IS DIRECTLY LEVEL SENSING SYSTEMS. QUANTITY OF FUEL IN EACH OF THE TANKS.
PROPORTIONAL TO THE TEMPERATURE OF THE FUEL. FAULTS AND/OR ERRORS ARE REPORTED ON THE
THE FQIC MONITORS THE DROP IN VOLTAGE TO RELATED DISPLAY UNIT(S).
F
GIVE A VISUAL INDICATION OF FUEL TEMPERATURE.
FOR MORE INFORMATION REFER TO
EF
SCHEMES 02 TO 16

192MB

FUNCTIO:-HELQAYDR
N_SM_284201_B_010001__AC

28-42-01 P 0001 SHEET 1 - FUEL - QUANTITY INDICATING - BLOCK DIAGRAM


** ON A/C 001-013, 051-150, 202-206, 208-250, 301-350, 401-500

Print Date: November 24, 2018 Page 1 of 1