CENTRO ECOMAULE, PLANTA DE TRATAMIENTO DE LIXIVIADOS

MEMORIA DE CALCULO SISTEMA HDRONEUMATICO


SITUACIÓN NORMAL

CALCULO ESTANQUE HIDRONEUMATICO


Qa (Lt/s) = 10.6 Qb (Lt/s) = 4.2 POTENCIA MOTOR HP = 5.5
Pa (atm)= 3.39 Pb (atm) = 5.23 PRESION DE CORTE BBA 1 atm = 10,33 mca

Qm = (Qa + Qb)/2
Qm = 7.4 l/s
T= 1.5 2.35 (minutos) 40 Partidas por hora
VR = Qm*T/4
VR = 166.5 lt
VE = VR(Pb+1)/(Pb-Pa)
VE = 563.7 Lt

VOLUMEN DE ESTANQUE = 600 Este Vale

MEMORIA DE CALCULO SISTEMA HDRONEUMATICO


SITUACIÓN DE INCENDIO

CALCULO ESTANQUE HIDRONEUMATICO


Qa (Lt/s) = 5 Qb (Lt/s) = 3 POTENCIA MOTOR HP = 2
Pa (atm)= 2.5 Pb (atm) = 3.6 PRESION DE CORTE BBA

Qm = (Qa + Qb)/2 0
Qm = 4
T= 4 1.41 (minutos) 15 Partidas por hora
VR = Qm*T/4
VR = 240
VE = VR(Pb+1)/(Pb-Pa)
VE = 1003.6 Lt

VOLUMEN DE ESTANQUE = 1000

RESULTADOS
DATOS

403050523.xls
CENTRO ECOMAULE, PLANTA DE TRATAMIENTO DE LIXIVIADOS

Diámetro Boquilla
Qm 7.40 L/s
V 8 m/s
Ad neta 0.000925
Ad 0.004625 20%
d 19.18 mm Máx 3" (eventualmente 4")
0.76 pul 0,5 a 0,6 Dt

Se debe especificar que la calibración en sitio una vez montado, la presión


de aire debe ser la siguiente:
Paire = Pa - 2 m.c.a = 37.0 m.c.a.
Pa: Presion de partida

403050523.xls
PLANTA ELEVADORA

ALTURA GEOMETRICA
C eje bomba 194.1
CA MIN 199.00
P partida (bar) 2.40 24
Hg 19.10

PERDIDAS FRICCIONALES

Q MAT DN D int L C Hs V
Succión 1 CEM ASB 150.0 150.0 130.0 130.0 1,738.10 0.07
Succión 1 PVC 100.0 99.4 30.0 140.0 2,594.25 0.17
Succión 1 ACERO 100.0 100.0 5.0 100.0 782.96 0.17
Impulsión 1 Acero 50.0 50.0 3.0 100.0 13,740.96 0.66
18,856.26

PERDIDAS SINGULARES

ELEMENTO DIAMETRO CANTIDAD K Q Hs


Salida estanque 150 1 1 1 163.38
Valv compuerta 150 2 0.2 1 65.35
Reducc 150x75 75 1 0.26 1 679.66
Med Caudal 75 2 4 1 20,912.65
Ampliación 75x150 150 1 0.33 1 53.92
Tee 150 x 100 100 1 0.2 1 165.42
Reducc 100x75 75 1 0.05 1 130.70
Valv compuerta 100 1 0.2 1 165.42
Ampliación 75x100 75 1 0.13 1 339.83
Curva 45º 100 3 0.14 1 347.39
Reducc 100x75 100 1 0.05 1 41.36
Vvla. Bola 75 1 2.5 1 6,535.20 29,600.29
Codo 90º 50 5 0.51 1 33,746.16
Vvla. Bola 50 1 2.5 1 33,084.47
Vvla. Chek 50 1 2 1 26,467.57
Tee 2 x 2 50 2 1.3 1 34,407.85
Ampliación 50x150 50 1 0.33 1 4,367.15 132,073.20

161,673.48

CURVA DEL SISTEMA

Q (l/s) H (m)
0.00 19.1
2.78 20.7
5.56 25.4
8.33 33.0
11.11 43.6
13.89 57.2
16.67 73.7
19.44 93.1
22.22 115.4
25.00 140.6
27.78 168.8
30.56 199.8
33.33 233.6
PLANTA ELEVADORA

ALTURA GEOMETRICA
C eje bomba 194.1
CA MIN 199.00
P partida (bar) 3.60 36
Hg 31.10

PERDIDAS FRICCIONALES

Q MAT DN D int L C Hs V
Succión 1 CEM ASB 150.0 150.0 130.0 130.0 1,738.10 0.07
Succión 1 PVC 100.0 99.4 30.0 140.0 2,594.25 0.17
Succión 1 ACERO 100.0 100.0 5.0 100.0 782.96 0.17
Impulsión 1 Acero 50.0 50.0 3.0 100.0 13,740.96 0.66
18,856.26

PERDIDAS SINGULARES

ELEMENTO DIAMETRO CANTIDAD K Q Hs


Salida estanque 150 1 1 1 163.38
Valv compuerta 150 2 0.2 1 65.35
Reducc 150x75 75 1 0.26 1 679.66
Med Caudal 75 2 4 1 20,912.65
Ampliación 75x150 150 1 0.33 1 53.92
Tee 150 x 100 100 1 0.2 1 165.42
Reducc 100x75 75 1 0.05 1 130.70
Valv compuerta 100 1 0.2 1 165.42
Ampliación 75x100 75 1 0.13 1 339.83
Curva 45º 100 3 0.14 1 347.39
Reducc 100x75 100 1 0.05 1 41.36
Vvla. Bola 75 1 2.5 1 6,535.20 29,600.29
Codo 90º 50 5 0.51 1 33,746.16
Vvla. Bola 50 1 2.5 1 33,084.47
Vvla. Chek 50 1 2 1 26,467.57
Tee 2 x 2 50 2 1.3 1 34,407.85
Ampliación 50x150 50 1 0.33 1 4,367.15 132,073.20

161,673.48

CURVA DEL SISTEMA

Q (l/s) H (m)
0.00 31.1
2.78 32.7
5.56 37.4
8.33 45.0
11.11 55.6
13.89 69.2
16.67 85.7
19.44 105.1
22.22 127.4
25.00 152.6
27.78 180.8
30.56 211.8
33.33 245.6
36.11 282.4
38.89 322.0
41.67 364.5
44.44 409.9

1.31 31.5 4.7


Datos de la bomba existente
Marca Vogt
Modelo N 630
Velocidad 2900 1/min
Diametros:
entrada 3¨ pulgadas
Salida 21/2¨ pulgadas

Curva de la bomba y del sistema


Planta Elevadora Aeródromo

Q (Lt/s) Q (m³/hr) Bomba (m) Sistema (m) Sistema (m)


(1) (2)
0.00 0.00 69.00 31.1 19.1
2.78 10.00 69.70 32.7 20.7
5.56 20.00 69.80 37.4 25.4
8.33 30.00 69.80 45.0 33.0
11.11 40.00 69.70 55.6 43.6
13.89 50.00 69.10 69.2 57.2
16.67 60.00 68.50 85.7 73.7
19.44 70.00 68.00 105.1 93.1
22.22 80.00 67.00 127.4 115.4
25.00 90.00 66.00 152.6 140.6
27.78 100.00 64.60 180.8 168.8
30.56 110.00 63.20 211.8 199.8
33.33 120.00 61.80 245.6 233.6
36.11 130.00 60.00 282.4 270.4
38.89 140.00 57.80 322.0 310.0
41.67 150.00 55.20 364.5 352.5
44.44 160.00 52.80 409.9 397.9

Grafico Nº1
COCHRANE, SECTOR CHACRAS ESTRADA NORTE
Puntos de operación hidroneumático-bomba
140.0

120.0

100.0
Alturas (m)

80.0

60.0

40.0

20.0

0.0
0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.00
Alturas
60.0

40.0

20.0

0.0
0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.00
Caudal (l/seg)

Curva Bomba Presión parada Presión partida


MEMORIA DE CALCULO SISTEMA HDRONEUMATICO

CAUDALES PRESIONES DEL SISTEMA


CANT ARTEFACTOS Lts/min Lts/min Diferencia de cota mts. 5
5 lavatorios (Lo) 10 50 Pérdidas de carga m.c.a. 8
5 WC 20 100 Presión Ütil m.c.a. 7
3 baños lluvia (Boll) 15 45 Total Presión Pa (m.c.a.) 20
2 lavaplatos (Lv) 15 30
2 lavaderos (Lv) 20 40
265

Caudal Máximo Probable QMP (lts/min) 81.31375

CALCULO ESTANQUE HIDRONEUMATICO


Qa (Lt/s) = 1.5 Qb (Lt/s) = 0.5 POTENCIA MOTOR HP = 30
Pa = 2.5 Pb = 3.5 PRESION DE CORTE BBA =

Qm = (Qa + Qb)/2
Qm = 1
T= 4 5.477226 (minutos) 15 Partidas por hora
VR = Qm*T/4
VR = 60
VE = VR(Pb+1)/(Pb-Pa)
VE = 270 Lt

VOLUMEN DE ESTANQUE = 100


RESULTADOS
DATOS
Altitud Patm bar mbar N/cm2 Pa (N/m2) atm Kg/cm2
m mbar 1 1000 10 100000 1 1.019716
0 1013
500 980 Kg m/s2
1000 913 1N 1
1500 872
2000 817
2500 763

T Pvap
ºC bar
20 0.02337
40 0.07375
60 0.19920
80 0.47360
90 0.70110
100 1.00000
mca
10.19716

You might also like