You are on page 1of 2

®

RheoFIT 763
A high performance concrete superplasticiser based on modified polycarboxylic ether

Description This greatly improves cement dispersion. At the


RheoFIT® 763 has been primarily developed for start of the mixing process the same electrostatic
applications within the Manufactured Concrete dispersion occurs as described previously but the
Products (MCP) industry where the highest presence of the lateral chains, linked to the
durability and performance is required. polymer backbone, generate a steric hindrance
RheoFIT® 763 is free from chlorides and complies which stabilises the cement particles capacity to
with ASTM C494 Types A and F. separate and disperse.
RheoFIT® 763 is compatible with all Portland
Typical applications
cements that meet recognised international
The excellent dispersion properties of RheoFIT®
standards.
763 make it the ideal admixture for precast and
FIT 4 VALUE hollow core concrete where low water cement
RheoFIT® 763 is a key component to BASF’s FIT ratios are required. This property allows the
4 VALUE concept.
production of very high early and high ultimate
FIT 4 VALUE considers the four elements strength concrete with minimal voids and
essential for MCP Manufactures: therefore optimum density. Due to the strength
1. FIT for Economics development characteristics the elimination or
2. FIT for Performance reduction of steam curing in precast works may
3. FIT for Aesthetics be considered as an economical option.
4. FIT for Durability
Here, FIT means meeting every requirement for • less vibration required
economics, performance, aesthetics and • reduced labour requirement
durability. • improved surface finish
Chemistry and mechanism of action of • increased output
RheoFIT® 763
Packaging
Conventional superplasticisers, such as those
RheoFIT® 763 is available in 208 litre drums and in
based on sulphonated melamine and naphthalene
bulk tanks upon request.
formaldehyde condensates, at the time of mixing,
become absorbed onto the surface of the cement *Typical properties
particles. This absorption takes place at a very Form viscous liquid
early stage in the hydration process. The Colour light brown
Relative density 1.1 @ 20°C
sulphonic groups of the polymer chains increase
pH 6.6
the negative charge on the surface of the cement Viscosity 128 +/ - 30 cps @ 20°C
particle and dispersion of the cement occurs by Transport Not classified as dangerous
electrostatic repulsion. Labelling No hazard label required

RheoFIT® 763 is differentiated from conventional


Standards
superplasticisers in that it is based on a unique
EN 934-2 Table 3.1 and 3.2
carboxylic ether polymer with long lateral chains.
®
RheoFIT 763
Effect on hardened concrete properties Thorough mixing is essential and a minimum
• increased early and ultimate compressive mixing cycle, after the addition of the RheoFIT®
strengths 763, of 60 seconds for forced action mixers is
• increased flexural strength recommended.
• higher E modulus
Storage
• improved adhesion to reinforcing and
RheoFIT® 763 should be stored in original
stressing steel
containers and at above 5°C. If frozen gradually
• better resistance to carbonation
thaw and agitate until completely reconstituted.
• lower permeability
Failure to comply with the recommended storage
• better resistance to aggressive atmospheric
conditions may result in premature deterioration of
conditions
the product or packaging. For specific storage
• reduced shrinkage and creep
advice consults BASF's Technical Services
• increased durability
Department.
Compatibility of RheoFIT® 763
Safety precautions
RheoFIT® 763 must not be used in conjunction
RheoFIT® 763 contains no hazardous substances
with any other admixture unless prior approval is
requiring labelling. For further information refer to
received form BASF Technical Services.
the Material Safety Data Sheet.
RheoFIT® 763 is suitable for mixes containing:
Note
• micro silica
Field service, where provided, does not constitute
• pulverised fuel ash
supervisory responsibility. For additional
• ground granulated blast furnace slag cement
information contact your local BASF
Dosage representative.
The normal dosage for RheoFIT® 763 is between BASF reserves the right to have the true cause of
0.5 and 1.6 litres per 100 kg of cement any difficulty determined by accepted test
(cementitious material). Dosages outside this methods.
range are permissible subject to trial mixes.
Quality and care
Directions for use All products originating from BASF’s Dubai, UAE
RheoFIT® 763 is a ready to use admixture that is facility are manufactured under a management
added to the concrete at the time of batching. system independently certified to conform to the
The maximum effect is achieved when the requirements of the quality, environmental and
RheoFIT® 763 is added after the addition of 50 to occupational health & safety standards ISO 9001,
70 % of the water. RheoFIT® 763 must not be ISO 14001 and OHSAS 18001.
added to the dry materials.
10/2006 BASF_CC-UAE revised 04/2008

* Properties listed are based on laboratory controlled tests.

Whilst any information contained herein is true, accurate and represents our best knowledge and experience, no warranty is given or implied with
any recommendations made by us, our representatives or distributors, as the conditions of use and the competence of any labour involved in the
application are beyond our control.

As all BASF technical datasheets are updated on a regular basis it is the user's responsibility to obtain the most recent issue.

BASF Construction Chemicals UAE LLC


P.O. Box 37127, Dubai, UAE
Tel: +971 4 8090800 Fax: +971 4 8851002
Certificate No. Certificate No. Certificate No.
www.basf-cc.ae e-mail: marketingcc.mideast@basf.com 963680 945787 772556

You might also like