You are on page 1of 2

WATER PRESSURE TEST

DAM PROJECT

LOCATION : CU-U.98 DEPTH d1= TO d2 =


DATE : Selasa 19-07-2016 TEST LENGTH L= d1 - d2 =
HOLE NO. : GROUND WATER h3 =
STAGE NO. : 4 GAUGE HEIGHT h2 =

PERIOD PRESSURE STATIC EFFECTIVE READING OF INJECT- Lu


TIME GAUGE HEAD PRESSURE FLOW METER (liter) ION RATE Value
minute Po=kg/cm2 P1=kg/cm2 P=kg/cm2 FROM UP TO TOTAL Q=l/min.
a b c d e=c+d f g h=g-f i=h/b j
18.40 4 179 214 35 36 16.667
214 253 39
253 292 39
292 331 39
331 369 38
369 408 39
408 446 38
446 466 20
466 503 37
503 539 36
360

d1 = depth of packer setting G Pressure Gauge


h1 = d1 (m) + L/2 (m) pump
h1 = kg/cm2
H2

when h1 > h3 Ground Surface


P1 = ( h2 + h3 ) / 10
P1 = kg/cm2 H3

when h1 < h3 D (depth) GWL


H1
P1 = ( h2 + h1 ) / 10
P1 = kg/cm2
L
10 x Q
Lu 
P xL
d

APPROVED CHECKED SUBMITTED

INSPECTOR CONSULTAN CONTRACTOR


m
m
2,4 m
0,8 m

REMARK

k
h1=d1+(L/2) 18.9
when h1>h3
P1=(h2+h3)/10
or
when h1<h3
P1=(h2+h1)/10
P1 = 0.5
Q = 9.10
L = 5.00
Lu = 10 x Q
LxP

ure Gauge

Surface

MITTED

TRACTOR