You are on page 1of 12

Device Manual

Chapter 4.1-W optosonic 3 radio net

L.83.0050 - Release 8.0.0 CH 2014


ista International GmbH - Grugaplatz 2 - 45131 Essen
http//www.ista.com

Nur für den internen Gebrauch—For internal use only—Uniquement pour utilisation interne
L.83.0050 - Release 8.0.0 CH 2014
ista International GmbH - Grugaplatz 2 - 45131 Essen
http://www.ista.com

Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne
Table of contents

1 Device data 3
1.1 General information 3
1.2 Device display 3
1.3 Technical data 4
1.4 Main and connection dimensions 5

2 Item numbers 6

3 Installation 7
3.1 Screwed installation 7
3.2 Installation with cable ties 7
3.2.1 With mounting plate 7
3.2.2 Without mounting plate 7
3.3 Final steps 8

4 Commissioning 9

5 Exchange 10
5.1 Preparatory steps 10
5.2 For installation on mounting plate 10
5.3 If installing without mounting plate 10

6 Reading 11
6.1 Radio reading AMM 11
6.2 Radio reading Walk by 11

7 Disposal 12

Device Manual
2/12 4.1-W optosonic 3 radio net
L.83.0050 - Release 8.0.0 CH 2014
ista International GmbH - Grugaplatz 2 - 45131 Essen
http//www.ista.com
Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne

1 Device data

1.1 General information

Device group Systems

Product name optosonic 3 radio net

Pictogram

Design/type Radio module for sensonic® II

Functional description
The optosonic 3 radio net radio module is used to in-
tegrate the sensonic® II heat meter into the ista sym-
phonic sensor net radio system.
To this end, the opto head of the optosonic 3 radio net
is connected to the optical interface of the
sensonic® II. The optosonic 3 radio net uses this in-
terface to read out the measured values of the
sensonic® II. The data is saved in the module.
The optosonic 3 radio net is programmed via radio. If
connected terminals have to be reprogrammed, the
necessary data is transmitted to the module by radio.
This then carries out the actual programming of the
terminal.

Packaging Single package (1 pc. per carton)

Delivery scope ▪ optosonic 3 radio net


▪ 2 screws

1.2 Device display

Type plate
optosonic® 3 radio net
S/N: XXX XXX XXX
Art. N° 19450

Display No display

Device Manual
4.1-W optosonic 3 radio net 3/12
L.83.0050 - Release 8.0.0 CH 2014
ista International GmbH - Grugaplatz 2 - 45131 Essen
http://www.ista.com

1.3 Technical data

Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne
Functional principle Optical read-out of connected counters

Interfaces ▪ Output:
Radio interface for the ista radio system symphonic sensor net.
▪ Input:
Opto head (protected against reversed polarity), cable length 0.5 m.

Radio interface ▪ Compatible with symphonic sensor net


▪ Transmission power: < 10 mW
▪ Radio frequency: 868 MHz
▪ Duration of transmission telegram: < 10 msec/transmission
▪ Transmission rate: ~ 90 kbaud (bit/sec)
▪ Transmission method: bidirectional
▪ Data integrity: encrypted transfer

Weight 0.110 kg

Material ABS

Casing colour RAL 9002

CE label 1999/5/EC

Storage Temperature:
▪ 1st year: -25 °C to +70 °C
▪ then 0 °C to +70 °C
To be stored in a dry place

Ambient temperature 0 °C - 70 °C

Relative humidity 5 % - 95 %

Protection class IP54 acc. to EN 60529


i.e.:
▪ Protection against foreign objects: Protects against damaging amount of dust.
▪ Protects against contact: complete protection against contact.
▪ Protection against water: Protection against splash water on all sides.

Power supply 3 V lithium battery

Life cycle 10 years + 1 year reserve + 1 year storage

Technology Integrated circuit (standard)

Parameterisation data ▪ Radio network number


▪ Reference date

Device Manual
4/12 4.1-W optosonic 3 radio net
L.83.0050 - Release 8.0.0 CH 2014
ista International GmbH - Grugaplatz 2 - 45131 Essen
http//www.ista.com
Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne

Recorded data ▪ Serial number, device ID


▪ Current date and time
▪ Next due date
▪ Commissioning date
▪ Error status

Saved consumption values Energy quantity (total volume) for


▪ 14 month-end values with date
▪ 2 reference date values with date

Reading frequency Generally 12 - 52 times per year

1.4 Main and connection dimensions

Main dimensions
H = 28 mm
W = 57 mm
L = 100 mm

Opto head dimensions


H = 15 mm
W = 64 mm
L = 19 mm

Cable length 0.5 m

Device Manual
4.1-W optosonic 3 radio net 5/12
L.83.0050 - Release 8.0.0 CH 2014
ista International GmbH - Grugaplatz 2 - 45131 Essen
http://www.ista.com

Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne
2 Item numbers
Devices
19450 optosonic 3 radio net

Accessories
19452 optosonic/pulsonic 3 radio mounting plate

81621 Adhesive seal sensonic, grey

81627 ista meter tamper proofing, grey 10 x 40

Device Manual
6/12 4.1-W optosonic 3 radio net
L.83.0050 - Release 8.0.0 CH 2014
ista International GmbH - Grugaplatz 2 - 45131 Essen
http//www.ista.com
Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne

3 Installation

3.1 Screwed installation

1 2 3 4 5 6

1. Prior to drilling, check that there are no electricity cables, 4. Attach the mounting plate to the wall.
gas or water pipes below the surface at the installation site. 5. Align the mounting plate vertically
2. Drill holes (6 mm) using spirit level.
with mounting plate to determine the hole spacing. 6. Tighten screws firmly.
3. Insert dowels. Continue with final steps.

3.2 Installation with cable ties

3.2.1 With mounting plate

1 2

1. Connect cable ties to the mounting plate. Continue with final steps.
2. Fasten the mounting plate with cable ties (e.g. on a pipe).

3.2.2 Without mounting plate

1 2

1. Connect cable ties to optosonic 3 radio net . Continue with item 8.


2. Fasten the optosonic 3 radio net with cable ties (e.g. to a
pipe).

Device Manual
4.1-W optosonic 3 radio net 7/12
L.83.0050 - Release 8.0.0 CH 2014
ista International GmbH - Grugaplatz 2 - 45131 Essen
http://www.ista.com

3.3 Final steps

Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne
1 2 3 4 5 6

1. Position module on mounting plate (if installing with mount- 4. Glue the opto head onto the sensonic II.
ing plate). 5. Screw together the opto head and sensonic II.
2. Clean the contact surface on the sensonic II. 6. Use adhesive seals to seal the opto head above the screws.
3. Pull off the protective foil from the rear of the opto head.

Device Manual
8/12 4.1-W optosonic 3 radio net
L.83.0050 - Release 8.0.0 CH 2014
ista International GmbH - Grugaplatz 2 - 45131 Essen
http//www.ista.com
Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne

4 Commissioning

1 2 3 4 5 6

7 8 9 10 11

1. Open clamping cover. 6. Position jumper on the right-hand pins and pull off again af-
2. Jumper in as delivered condition. ter approx. 5 seconds.
3. Remove jumper. The device sends installation beacons for 4 minutes.
The optosonic attempts to set up communication with the 7. Parameterizing
heat meter via the optical interface. If this attempt is suc- with PDA and MGW
cessful, the optosonic switches to installation mode for 4 8. Following parameterisation or 4 minutes the device switch-
minutes. es to measuring mode.
4. Parameterizing ▪ Following parameterisation, continue with step 9.
with PDA and MGW ▪ After 4 minutes without parameterisation, continue with
5. Following parameterisation or 4 minutes the device switch- step 6 (10 attempts in total).
es to measuring mode. 9. Close clamping cover
▪ Following parameterisation, continue with step 9. 10. Seal screw.
▪ After 4 minutes without parameterisation continue with 11. Clean the device.
step 6.

Device Manual
4.1-W optosonic 3 radio net 9/12
L.83.0050 - Release 8.0.0 CH 2014
ista International GmbH - Grugaplatz 2 - 45131 Essen
http://www.ista.com

Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne
5 Exchange

5.1 Preparatory steps

1 2

1. Undo the screws in the opto head. 2. Disconnect the opto head from the sensonic II.

5.2 For installation on mounting plate

1 2

1. Remove old optosonic 3 radio net from the mounting plate. 2. Continue with installation from point 7.

5.3 If installing without mounting plate

1 2

1. Cut cable ties (for installation without mounting plate). 2. Continue with installation from point 1b.

Device Manual
10/12 4.1-W optosonic 3 radio net
L.83.0050 - Release 8.0.0 CH 2014
ista International GmbH - Grugaplatz 2 - 45131 Essen
http//www.ista.com
Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne

6 Reading

6.1 Radio reading AMM

1. Readout via symphonic sensor net.

6.2 Radio reading Walk by

1 2

1. Read off appliances 2. Check data in the PDA


with PDA/MGW by Walk by Are all devices recorded?

Device Manual
4.1-W optosonic 3 radio net 11/12
L.83.0050 - Release 8.0.0 CH 2014
ista International GmbH - Grugaplatz 2 - 45131 Essen
http://www.ista.com

Nur für den internen Gebrauch — For internal use only — Uniquement pour utilisation interne
7 Disposal

1 2

1. Do not dispose of the old device in the household waste. They will ensure proper disposal.
2. Send obsolete devices to the main warehouse via outlet.

Device Manual
12/12 4.1-W optosonic 3 radio net

You might also like