Carboguard® 703

Selection & Specification Data Substrates & Surface Preparation


Generic Type Amine Cured Epoxy General Surfaces must be clean and dry. Employ adequate
methods to remove dirt, dust, oil and all other
Description Ultra high build, airless-applied, solvent free contaminants that could interfere with adhesion of
coating for use on steel and concrete the coating.
substrates. Widely used as a splash zone
coating on marine installations, tank lining in Steel Immersion: SSPC-SP5 – 3-4 mils
petroleum services and for protection of Non-Immersion: SP10 – 2-3 mils
buried pipelines. It has extremely good impact
and abrasion resistance and is suitable for Concrete Immersion and Non-Immersion:
variety of heavy industrial applications. Concrete must be cured 28 days at 75°F (24°C)
and 50% relative humidity or equivalent. Prepare
surfaces in accordance with ASTM D4258 Surface
Cleaning of Concrete and ASTM D4259 Abrading
Features High film build and edge protection. Concrete. Voids in concrete may require surfacing.
Excellent resistance to corrosion and
abrasion
May be used in conjunction with cathodic
Protection.
Application by airless spray equipment
(plural component acceptable but not
required.)
Meets most VOC (Volatile Organic Content)
regulations.

Color Gray, Buff, other colors on application in batch


quantities.
Finish Egg Shell

Primers Self-priming

Topcoats Normally not required. Polyurethanes for non


immersion service when required. Brush blast-
ing or special cleaning procedures may be
required.

Dry Film 1 coat system: 8-25 mils (203-635 microns)


Thickness Depending on service requirement.

Solids Content By Volume: 95% ± 2%

Theoretical 190 ft2/gal @ 8 mils, 4.75 m2 / l @ 200 microns


Coverage Rate Allow for loss in mixing and application

VOC Values As supplied: 28.47 g/l


These are nominal values and may vary
slightly with color.

Dry Temp. Continuous: 200°F (93°C)


Resistance Non-Continuous: 250°F (121°C)
Discoloration and loss of gloss is observed
above 200°F (93°C)
Wet Temp. Immersion temperature resistance depends
Resistance upon exposure. Consult Carboline Technical
Service for specific information.

Limitations Epoxies lose gloss, discolor and eventually


chalk in sunlight exposure.

July 2016
To the best of our knowledge the technical data contained herein is true and accurate on the date of publication and is subject to change without prior notice. User must contact StonCor ME to
verify correctness before specifying or ordering. No guarantee of accuracy is given or implied. We guarantee our products to conform to Carboline quality control. We assume no responsibility for
coverage, performance or injuries resulting from use. Liability, if any, is limited to replacement of products. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY STONCOR
ME, EXPRESS OR IMPLIED, STATUTORY, BY OPERATION OF LAW, OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Carboguard® 703

Application Equipment Application Conditions


Spray Application Recommended for application by single or plural
(General) component airless spray. This is high solids coating and Condition Material Surface Ambient Humidity
may require adjustments in spray techniques. Wet film 60° –85°F 60° –85°F 60° –90°F
Normal 0 - 80%
thickness is easily and quickly achieved. The following (16°-29°C) (16°-29°C) (16°-32°C)
spray equipment has been found suitable and is 50°F 50°F 50°F
Minimum 0%
available from manufactures such as Binks, DeVilbiss (10°C) (10°C) (10°C)
and Graco. 90°F 125°F 110°F
Maximum 85%
(32°C) (52°C) (43°C)
Conventional Not recommended
Spray This product simply requires the substrate temperature to be above the dew point.
Condensation due to substrate temperatures below the dew point can cause flash
Airless Spray Pump Ratio: 45:1 (min.)
rusting on prepared steel and interfere with proper adhesion to the substrate.
GPM Output: 3.0 (min.)
Special application techniques may be required above or below normal application
Material Hose: ½” I.D. (min)
conditions. To reduce out gassing when applying to concrete substrates, do not
Tip Size: 0.025 - 0.035”
apply in direct sunlight or when surface temperatures are increasing. Best results
Output PSI: 2700-3000
are obtained when ambient and surface temperatures are decreasing or constant.
Filter Size: 60 mesh
Teflon packings are recommended and available from
the pump manufacturer.
Contact Carboline Technical Service for plural
Curing Schedule
component equipment recommendations.
Surface Temp. & Maximum Final Cure for
Brush & Roller Not recommended for tank lining applications except Immersion
50% Relative Dry or Recoat Recoat Time
(General) when striping welds. Service
Humidity
Brush For touch up and limited areas only. 60°F (16°C) 24 Hours 2 Days 14 Days
75°F (24°C) 8 Hours 1 Days 10 Days
Roller For touch up and limited areas only. 90°F (32°C) 6 Hours 16 hours 7 Days
These times are based on a 10 mils (250 micron) dry film thickness. Higher film
Mixing & Thinning thickness, insufficient ventilation or cooler temperatures will require longer cure
times. Condensation on the surface or humidity above 25% during application and
Mixing Power mix separately, then combine and power mix. curing will result in a surface haze or blush. Any haze or blush must be removed
DO NOT MIX PARTIAL KITS. by water washing before recoating. During high humidity conditions, it is
recommended that the application be done while temperatures are increasing. If
Ratio 5:1 Ratio (A to B) the maximum recoat times is exceeded, the surface must be washed with
detergent and water, then abraded by sweep blasting prior to the application of
Thinning Not recommended. Thin only if necessary up to 10% of additional coats. For force curing, contact Carboline Technical Service for
Thinner 21 and for hot and windy conditions, use Thinner specific requirements. *Note: Final cure temperatures below 60 °F (16°C) are
33 up to 10%. not recommended for tank linings.

Use of thinners other than those supplied or


recommended by Carboline may adversely affect
product performance and void product warranty,
Packaging, Handling & Storage
whether expressed or implied. Shipping Weight 5 Gallon Kit
(Approximate) 68.56 Lbs. (31.1 kg)
Flash Point (Setaflash) Part A: >205°F (96°C)
Pot Life 30 minutes at 75°F (24°C). Pot life ends when material
begins to thicken and starts to heat up. Pot life times will Part B: >205°F (96°C)
be less at higher temperatures.
Storage (General) Store Indoors.

Clean up & Safety Storage Temperature 40° -110°F (4°-43°C)


& Humidity 0-100% Relative Humidity
Cleanup Use #2 Thinner or Acetone. In case of spillage, absorb
and dispose of in accordance with local applicable Shelf Life 18 months at 75°F (24°C)
regulations.
*Shelf Life: (actual stated shelf life) when kept at recommended
Safety Read and follow all caution statements on this product storage conditions and in original unopened containers.
data sheet and on the MSDS for this product. Employ
normal workmanlike safety precautions. Hypersensitive
persons should wear protective clothing, gloves and use
protective cream on face, hands and all exposed areas.
Ventilation Vapors and/or spray mist may cause explosion. When
used as a tank lining or in enclosed areas, thorough air
circulation must be used during and after application
until the coating is cured. The ventilation system should
be capable of preventing the solvent vapor
concentration from reaching the lower explosion limit for
the solvents used. In addition to ensuring proper
ventilation, appropriate respirators must be used by all
application personnel.

July 2016
To the best of our knowledge the technical data contained herein is true and accurate on the date of publication and is subject to change without prior notice. User must contact StonCor ME to
verify correctness before specifying or ordering. No guarantee of accuracy is given or implied. We guarantee our products to conform to Carboline quality control. We assume no responsibility for
coverage, performance or injuries resulting from use. Liability, if any, is limited to replacement of products. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY STONCOR
ME, EXPRESS OR IMPLIED, STATUTORY, BY OPERATION OF LAW, OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.