Steel DT DT La La

rectangular oF oC f m
0 0.0 600 183 1
25 13.9 600 183 2
70 38.9 400 122 3
90 50.0 400 122 4
5

Concrete DT DT La La
rectangular oF oC f m
0 0.0 600 183 1
25 13.9 600 183 2
70 38.9 350 107 3
90 50.0 350 107 4
5

Any material DT DT La La
Non-rectangular oF oC f m
0 0.0 300 91 1
25 13.9 300 91 2
70 38.9 180 55 3
90 50.0 180 55 4
5
DT 20 oC R Lmax Note
La 168 m m
Heated and hinged-column base Yes 0.00 168
1 criteria
Heated and Air cond. Yes 0.15 193 is
Unheated Yes -0.33 113 applied,
Fixed-column base Yes -0.15 143 not apply
for 2
High lateral stiffness at one end of the plan Yes -0.25 126

DT 20 oC R Lmax Note
La 164 m m
Heated and hinged-column base Yes 0.00 164
1 criteria
Heated and Air cond. Yes 0.15 189 is
Unheated Yes -0.33 110 applied,
Fixed-column base Yes -0.15 140 not apply
for 2
High lateral stiffness at one end of the plan Yes -0.25 123

DT 20 oC R Lmax Note
La 82 m m
Heated and hinged-column base Yes 0.00 82
1 criteria
Heated and Air cond. Yes 0.15 95 is
Unheated Yes -0.33 55 applied,
Fixed-column base Yes -0.15 70 not apply
for 2
High lateral stiffness at one end of the plan Yes -0.25 62