Design
Two 3/2-way solenoid valves, normally closed, are contained in a valve housing. This valve housing with push-in fittings is mounted onto the
function plate, which is equipped with a supply port and silencer. The electrical connections are equipped with safety sockets. The unit is
mounted on the slotted assembly board using the locking system with the blue lever (mounting variant "A"). The component can be moved in
the direction of the slot.
4 2
14 12
1M2 1M1
1 5 3
Function
The 3/2-way solenoid valves have a common supply port. The valves are reversed by applying a voltage to solenoid coil 1M1 or 1M2 and
return to their initial position by an air spring when the signal is removed. Their switching status is indicated by two LEDs in the connector
housings. Both valves are equipped with manual override.
One of the solenoid valves is reversed when voltage is applied to solenoid coil 1M1 (1 2).
The other solenoid valve is reversed when voltage is applied to solenoid coil 1M2 (1 4).
Technical data
Pneumatics
Subject to change
Electrical
Operating voltage 24 V DC
Residual ripple ≤ 10 %
Protection class IP 40
Subject to change