You are on page 1of 5

BOE (BOILER OPERATION ENGINEERING)

QUESTIONS AND ANSWERS:-

Q. Economizer of boiler has main function to….


a. Heat up incoming water excess steam
b. Heat up pulverized fuel by exhaust gases
c. Heat up the incoming air by exhaust gases
d. Heat up the incoming water by exhaust gases

Q. In a superheater
a. Pressure rises and temperature drops
b. Temperature rises and pressure drops
c. Temperature rises and pressure remains unchanged

d. Pressure rises and temperature remains the same

Q. The steam power plant efficiency can be improve by


a. Using large quantity of water
b. Burning large quantity of coal
c. Using high temperature and high pressure steam
d. Decreasing the load on the plant

Q. Vacuum can be measured by using


a. Rotameter
b. Pitot tube
c. U tube manometer
d. Vanturimeter

Q. Electrostatic Precipitator is installed between


a. Induced draft fan and chimney
b. Air preheater and induced draft fan
c. Economizer and air pre heater
d. Boiler furnace and economizer

Q. At which of the following pressure, the enthalpy of


evaporation if the steam will be the highest
a. 4 kg/cm2
b. 20 kg/cm2
c. 12 kg/cm2
d. 16 kg/cm2
Q. If the partical pressure of air and steam in a
condenser is pa and pb respectively, then according to
Dalton, s law the pressure in condenser is equal to
a. Pa-pb
b. Pa+pb
c. (Pa+pb)/2
d. (Pa × pb )

Q. Water at a pressure 4 kg/cm2 and 160 digree Celsius


temperature, when exposed to atmosphere will
a. Start boiling
b. Cool down
c. Remains as it was
d. Flash and get converted into steam

Q. Proximity analysis of coal gives the following result:


a. Carbon, hydrogen, nitrogen, sulphur
b. Fixed carbon, ash, volatile matter, moisture
c. Higher calorific value
d. Lower calorific value

Q. Proper sizing of steam pipe lines helps in minimizing


a. Steam requirements
b. Temperature drops
c. Boiler efficiency
d. Pressure drops

Q. What is the impact on flow and discharged pressure


when the impeller of pump is trimmed ?
a. Flow decrease with increase pressure
b. Both flow and pressure increase
c. Both flow and pressure decrease
d . Flow increase with decrease pressure

Q. The maximum heat loss in a boiler occur due to


a. Unbrunt carbon
b. Dry flue gases
c. Radiation losses
d. Moisture in fuel

Q. In power unit, 1 metric H.P=


a. 746.01 watt
b. 750 watt
c. 735.75 watt
d. 720 watt

Q. 1 kacl=4.187 kj= BTU


a. 1.80
b. 2.205
c. 3.969
d. 3.08

Q.15 digree Celsius=………..digree F


a. 40 digree F
b. 59 digree F
c. 47 digree F
d. 52 digree F

Q. During phase change, heat received by the steam


without any change of temperature is known as
a. Sensible heat
b. Saturation heat
c. Latent heat of evaporation
d. Superheater

Q. In a boiler system, major part of latent heat is


received in the
a. Deaerator
b. Evaporater (water wall )
c. Superheater
d. Economizer

Q. R.O plant membrane ph should be maintain in range


of
a. 1 to 3
b. 4 to 5
c. 6 to 7
d. 7 to 10

Q. Corrosion of Metallic flue gas chimney depends on:


a. Percent of sulphur in the fuel
b. Temperature of exit flue gas from chimney
c. Presence if vanadium pent- oxide in fuel oil
d.all of above
Q. What will be the proportion by volume of cement,
sand and gravel commonly used in power plant in
preparation of strongest concrete mixture in that order?
a. 1:3:5
b. 1 :11/2:3
c. 1:2:4
d. 1:4:5

Q. Low carbon steel contains


a. 0.1 %to 0.27 %carbon
b. 0.6 %to 1.5 %carbon
c. 0.2 %to 0.3 %carbon
d. None of the above

Q. Opacity meter is used to measured


a. Feed water ph
b. Dissolved oxygen
c. Stack emission in SPM
d. Drum conductivity

Q. Steam is compressive vapour and obeys


a. All law of liquids
b. All laws of gases
c. All laws of solids
d. All laws of above

Q. The density of saturated water at 100 digree Celsius


a. 9.58 kg/cm3
b. 9.58 kg/ cm2
c. 958 kg/m3
d. None of the above

Q. At the critical point, the water and steam density


becomes
a. Equal
b. Zero
c. 100 kg/cm3
d. None of above

Q. Silica has a tendency to evaporated with steam


a. At temperature> 200
b. At pressure >80 bar
c. At pressure <80 bar
d. None of the above

Q. Pure steam and water are non conductance of


electricity but as the impurities increase
a. The conductivity reaming same
b. The conductivity decrease
c. The conductivity increase
d. None of the above

Q. Any pipe is designed by


a. Standard thickness
b. ID inside impeller
c. Nominal bore
d. None of the above

Q. Any tube designed by


a. Nominal thickness
b. Nominal bore
c. ID inside diameter
d. OD outside diameter